930 resultados para Facial Reconstruction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article evaluates space closure mechanics efficiency in an extraction case where maximum anchorage was a requirement. The Segmented Arch Technique (SAT) was utilized as an anchorage control strategy to obtain maximum anterior retraction and, in consequence, significant facial profile change. A 20-year-10-month old woman needed severe labial and profile changes. The patient had four premolars extracted and SAT with type A mechanics [1] (Marcotte [2] activation protocol) was applied. The results showed significant reduction in labial protrusion and incisal angulation with effective anchorage control. The results were compared to others available in the literature derived from different techniques, where anterior retraction was also accomplished with maximum anchorage [3-7]. In conclusion, the SAT with type A mechanics has been shown to be another treatment option when significant changes in the soft-tissue profile are needed in extraction cases. © 2008. CEO. Published by Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the dimensional stability and detail reproduction of two silicones used for facial prosthesis, under the influence of chemical disinfection and storage time. Twenty-eight test specimens were obtained, half made of Silastic MDX 4-4210 silicone, and the other half of Silastic 732 RTV silicone. The test specimens were divided into 4 groups: Silastic 732 RTV and Silastic MDX 4-4210, with disinfection 3 times a week with Efferdent and without disinfection. Dimensional change was analyzed using an electronic comparison microscope and detail reproduction was observed under a stereo microscope, immediately and 2 months after the test specimens were made. Once the results were obtained, an analisis of variance (ANOVA) was applied, followed by the Tukey's Test with 1% confidence. The storage time factor had a statistical influence on dimensional stability: Silastic MDX 4-4210 had less contraction than Silastic 732 RTV. Chemical disinfection did not significantly alter the dimensional stability of the materials used. Regarding detail reproduction, no alteration of values was observed in any of the materials analyzed, regardless of storage period or disinfection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The objective of this study was to evaluate by a visual method of comparison the color stability of nonpigmented and pigmented facial silicones after accelerated aging. Materials and Methods: Two kinds of silicones were used in this study; one specifically formulated for facial prostheses and the other an acetic silicone for industrial use. Twenty-four trial bodies were made for each silicone. These were divided into colorless and intrinsically pigmented groups: ceramic, make-up, and iron oxide. The groups were submitted to accelerated aging for nonmetallic materials. An initial reading and subsequent readings were made at 163, 351, 692, and 1000 hours using a visual method of comparison. The values were annotated in a spreadsheet by two observers, according to scores elaborated for this study. Results: All groups presented color stability in the visual method. According to the results obtained and analyzed in this study, we can conclude that both silicones, Silastic 732 RTV and Silastic MDX 4-4210, behaved similarly, they can therefore be indicated for use in maxillofacial prosthesis. The time factor of aging influenced negatively, independently of the pigmentation, or lack of it, and of silicones and no group had visually noticeable alterations in any of the accelerated aging time, independently of the addition or not of pigments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

18 rabbits, New Zealand, males, adults were used for clinical and histological evaluation of repair dorsal buccal branch of facial nerve after 15, 30 and 60 days postoperatively (PO). The animals were divided into two groups for transection and 10-0 nylon monofilament epineural suture of buccal branch. In animals in Group I, the nerve was coated with protection of jejunum allograft preserved in glycerin 98% and in group II was applied epineural suture. Both groups occurred the return of movement of the upper lip from the eighth week. There was infiltrated cellular and giant cells with fibrosis unsystematic and collagen fibers of the allograft jejunum joing to the connective tissue. At 15 and 30 days of PO, the distal nerve stumps of both groups were found with degeneration wallerian and in 60 days, regenerated fibers. The repair of the dorsal buccal branch of facial nerve with the allograft wasn't significantly different between the control rabbits as to the assessment of histological and functional recovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the greatest challenges faced by buccomaxillofacial prosthetists is to reproduce the patient's exact skin color and provide adequate esthetics. To reach this objective, professionals must use materials with easy characterization and that maintain color over long periods of time. The objective of this study was, thus, to evaluate the color stability of two types of silicones, Silastic 732 and Silastic MDX4-4210. Twenty-four test specimens were made from each type of silicone and were divided into a colorless group and groups intrinsically pigmented with ceramics, cosmetics or iron oxide. The specimens were submitted to an accelerated system of aging for non-metallic materials. Readings were carried out initially and after periods corresponding to 163, 351, 692 and 1,000 hours of aging, using a reflection spectrophotometer analysis, and color alterations were calculated by the CIE L*a*b* system. The data were submitted to variance analysis and Tukey's test at a 5% level of probability. The results demonstrated that, irrespective of the period of time analyzed, all the materials underwent some type of chromatic alteration (ΔE > 0). The test specimens made with Silastic 732 and MDX4-4210, without pigmentation, presented the lowest color alteration values after 1,000 hours of aging. Of the pigments, ceramic presented the lowest color alteration values and cosmetic powder presented the highest values. Thus, it may be concluded that the materials without the incorporation of pigments presented similar color alteration values, and did not differ statistically. The cosmetic powder used in this study was the pigment that most altered the color of the test specimens. © 2009 Sociedade Brasileira de Pesquisa Odontológica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of muon reconstruction in CMS is evaluated using a large data sample of cosmic-ray muons recorded in 2008. Efficiencies of various high-level trigger, identification, and reconstruction algorithms have been measured for a broad range of muon momenta, and were found to be in good agreement with expectations from Monte Carlo simulation. The relative momentum resolution for muons crossing the barrel part of the detector is better than 1% at 10 GeV/c and is about 8% at 500 GeV/c, the latter being only a factor of two worse than expected with ideal alignment conditions. Muon charge misassignment ranges from less than 0.01% at 10GeV/c to about 1% at 500 GeV/c. © 2010 IOP Publishing Ltd and SISSA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the number of occlusal contacts achieved in temporal prostheses mounted in a semi-adjusted articulator using the facial arch and the Camper plane. Ten patients treated in a private clinic were selected to be rehabilitated with prostheses in previously placed single implants. For each patient two temporal prostheses were designed obtained under different conditions: (1) model mounting using facial arch and (2) Camper plane mounting. Prostheses were made and adjusted in the laboratory and placed only by an operator. The occlusal contacts achieved in each condition were photographed being assessed and quantified by a second professional not involved with the mounting conditions. Results obtained were analyzed by Mann-Whitney test with a 5 % significance level. There was not a statistically difference between the number of occlusal contacts when prostheses were made with facial arch or Camper plane (p= 0.113). The temporal dental prosthesis confection for single implants, semi-adjusted articulator using the Camper plane, not differ very much from the facial arch use, according to the number of resulting occlusal contacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Morphological and dentofacial alterations have been attributed to impaired respiratory function. Objective. To examine the influence of mouth breathing (MB) on children facial morphology before and after adenoidectomy or adenotonsillectomy. Methods. Thirty-three MB children who restored nasal breathing (NB) after surgery and 22 NB children were evaluated. Both groups were submitted to lateral cephalometry, at time 1 (T1) before and at time 2 (T2) 28months on average postoperatively. Results. Comparison between the MB and NB groups at T1 showed that mouth breathers had higher inclination of the mandibular plane; more obtuse gonial angle; dolichofacial morphology; and a decrease in the total and inferior posterior facial heights. Twenty-eight months after the MB surgical intervention, they still presented a dolichofacial morphologic pattern. During this period, MB altered the face growth direction and decreased their mandible plane inclination, with reduction in the SN.GoGn, PP.MP, SNGn, and ArGo.GoMe parameters as well as an increase in BaN.PtGn. Conclusion. After the MB rehabilitation, children between 3 and 6years old presented significant normalization in the mandibular growth direction, a decrease in the mandible inclination, and an increase in the posterior facial height. Instead, they still persisted with a dolichofacial pattern when compared with nasal breathers. © 2011 The Authors. International Journal of Paediatric Dentistry © 2011 BSPD, IAPD and Blackwell Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The following is a clinical case report of a patient whose chief complaint was the presence of generalized spacing in the maxillary anterior segment following orthodontic treatment. After meticulous clinical analyses and discussions of the clinical procedures to be adopted, dental bleaching was performed in both arches with 10% hydrogen peroxide (Opalescence Trèswhite Supreme 10% Hydrogen Peroxide - Ultradent Products, Inc., South Jordan, USA) after the conclusion and stabilization of orthodontic treatment. Then, the orthodontic appliance was removed and the diastemas in the maxillary anterior teeth were closed with Amelogen Plus (Ultradent Products, Inc., South Jordan, USA) resin composite. It was observed that the association of orthodontic, bleaching, and restorative procedures was capable of restoring dental shape, function, and esthetics, allowing the patient to smile without hesitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the effect of disinfection and accelerated ageing on the dimensional stability and detail reproduction of a facial silicone with different types of nanoparticle. A total of 60 specimens were fabricated with Silastic MDX 4-4210 silicone and they were divided into three groups: colourless and pigmented with nanoparticles (make-up powder and ceramic powder). Half of the specimens of each group were disinfected with Efferdent tablets and half with neutral soap for 60 days. Afterwards, all specimens were subjected to accelerated ageing. Both dimensional stability and detail reproduction tests were performed after specimen fabrication (initial period), after chemical disinfection, and after accelerated ageing periods (252, 504 and 1008 hours). The dimensional stability test was conducted using AutoCAD software, while detail reproduction was analysed using a stereoscope magnifying glass. Dimensional stability values were statistically evaluated by analysis of variance (ANOVA) followed by Tukey's test (p < 0.01). Detail reproduction results were compared using a score. Chemical disinfection and also accelerated ageing affected the dimensional stability of the facial silicone with statistically significant results. The silicone's detail reproduction was not affected by these two factors regardless of nanoparticle type, disinfection and accelerated ageing. © 2012 Informa UK, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Colour stability of resin and silicone is an important factor for longevity of facial prostheses. The aim of this study was to evaluate the colour stability of resins and silicone for facial prostheses. Three brands of acrylic resin and one of facial silicone were evaluated considering pigment incorporation for the colourless materials. Ten samples of each material were fabricated and submitted to measurements of chromatic alteration initially and after 90 and 180 days of weathering natural through visual analysis and spectrophotometry. Data were evaluated by ANOVA and Tukey test (p < 0.05). Statistically significant colour alteration was observed among some materials regardless of the period. The materials did not present a statistical difference between 90 and 180 days except for the pigmented heat-polymerized resin. The colour difference between pigmented Silastic MDX4-4210 and colourless Silastic was statistically significant (p < 0.01) in both periods as well as between pigmented and colourless heat-polymerized resin, and between the resins Rapidaflex and Lentaflex. The visual method demonstrated colour alteration in all materials evaluated during the first 90 days of ageing. All materials exhibited colour alteration due to exposure to environment. © 2012 Informa UK, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of muon reconstruction, identification, and triggering in CMS has been studied using 40 pb-1 of data collected in pp collisions at s = 7 TeV at the LHC in 2010. A few benchmark sets of selection criteria covering a wide range of physics analysis needs have been examined. For all considered selections, the efficiency to reconstruct and identify a muon with a transverse momentum pT larger than a few GeV/c is above 95% over the whole region of pseudorapidity covered by the CMS muon system, < 2.4, while the probability to misidentify a hadron as a muon is well below 1%. The efficiency to trigger on single muons with pT above a few GeVc is higher than 90% over the full η range, and typically substantially better. The overall momentum scale is measured to a precision of 0.2% with muons from Z decays. The transverse momentum resolution varies from 1% to 6% depending on pseudorapidity for muons with pT below 100GeV/c and, using cosmic rays, it is shown to be better than 10% in the central region up to pT = 1 TeV/c. Observed distributions of all quantities are well reproduced by the Monte Carlo simulation. © 2012 IOP Publishing Ltd and Sissa Medialab srl.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Melasma is a common acquired chronic hypermelanosis of sun-exposed areas which significantly impacts quality of life. There are few epidemiological studies in medical literature concerning these patients. Objective Characterize clinical and epidemiological data on Brazilian female patients with melasma. Methods A semi-structured questionnaire was administered to melasma patients treated at a dermatology clinic between 2005 and 2010. Association between variables was performed by multivariate regression models. Results We assessed 302 patients; intermediate skin phototypes III (34.4%) and IV (38.4%) were prevalent. Mean disease onset age was 27.5 ± 7.8 years and familiar occurrence of melasma was identified in 56.3%. The most commonly reported trigger factors were pregnancy (36.4%), contraceptive pills (16.2%) and intense sun exposure (27.2%). Preferred facial topographies were zygomatic (83.8%), labial superior (51.3%) and frontal (49.7%). Pregnancy induced melasma has been associated to early disease (OR = 0.86) and number of pregnancies (OR = 1.39). Childbearing was correlated to melasma extension. Older disease onset age was associated to darker skin phototypes. Co-occurrence of facial topographies supported clinical classification as centrofacial and peripheral melasma. Conclusion This population was characterized by: a high prevalence in adult females, intermediate skin phototypes, disease precipitation by hormonal stimulus and familiar genetic influence. © 2012 The Authors. Journal of the European Academy of Dermatology and Venereology © 2012 European Academy of Dermatology and Venereology.