998 resultados para FLUID CONCENTRATIONS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moltes civilitzacions s"han desenvolupat al costat de rius i mars, uns medis fluids que han servit de vehicle de cohesió i transport i que han afavorit la supervivència de les persones que vivien a les seves ribes. Per als egipcis va ser el Nil; per als mesopotamis, el Tigris i l"Eufrates, i per als grecs i fenicis, la Mediterrània. Un dels sistemes dels animals més complexos funcionalment és el nerviós, el qual assoleix l"expressió màxima en els vertebrats, molt especialment en òrgans com el cervell. Sorprenentment, el cervell també s"organitza, des de l"inici embrionari i durant tota la vida adulta, al voltant d"un fluid extraordinàriament dinàmic i complex: el líquid cerebrospinal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation of forensic evidence can occur at any level within the hierarchy of propositions depending on the question being asked and the amount and type of information that is taken into account within the evaluation. Commonly DNA evidence is reported given propositions that deal with the sub-source level in the hierarchy, which deals only with the possibility that a nominated individual is a source of DNA in a trace (or contributor to the DNA in the case of a mixed DNA trace). We explore the use of information obtained from examinations, presumptive and discriminating tests for body fluids, DNA concentrations and some case circumstances within a Bayesian network in order to provide assistance to the Courts that have to consider propositions at source level. We use a scenario in which the presence of blood is of interest as an exemplar and consider how DNA profiling results and the potential for laboratory error can be taken into account. We finish with examples of how the results of these reports could be presented in court using either numerical values or verbal descriptions of the results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is often assumed that total head losses in a sand filter are solely due to the filtration media and that there are analytical solutions, such as the Ergun equation, to compute them. However, total head losses are also due to auxiliary elements (inlet and outlet pipes and filter nozzles), which produce undesirable head losses because they increase energy requirements without contributing to the filtration process. In this study, ANSYS Fluent version 6.3, a commercial computational fluid dynamics (CFD) software program, was used to compute head losses in different parts of a sand filter. Six different numerical filter models of varying complexities were used to understand the hydraulic behavior of the several filter elements and their importance in total head losses. The simulation results show that 84.6% of these were caused by the sand bed and 15.4% were due to auxiliary elements (4.4% in the outlet and inlet pipes, and 11.0% in the perforated plate and nozzles). Simulation results with different models show the important role of the nozzles in the hydraulic behavior of the sand filter. The relationship between the passing area through the nozzles and the passing area through the perforated plate is an important design parameter for the reduction of total head losses. A reduced relationship caused by nozzle clogging would disproportionately increase the total head losses in the sand filter

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bioactive glasses are surface-active ceramic materials which support and accelerate bone growth in the body. During the healing of a bone fracture or a large bone defect, fixation is often needed. The aim of this thesis was to determine the dissolution behaviour and biocompatibility of a composite consisting of poly(ε-caprolactone-co-DL-lactide) and bioactive glass (S53P4). In addition the applicability as an injectable material straight to a bone defect was assessed. In in vitro tests the dissolution behaviour of plain copolymer and composites containing bioactive glass granules was evaluated, as well as surface reactivity and the material’s capability to form apatite in simulated body fluid (SBF). The human fibroblast proliferation was tested on materials in cell culture. In in vivo experiments, toxicological tests, material degradation and tissue reactions were tested both in subcutaneous space and in experimental bone defects. The composites containing bioactive glass formed a unified layer of apatite on their surface in SBF. The size and amount of glass granules affected the degradation of polymer matrix, as well the material’s surface reactivity. In cell culture on the test materials the human gingival fibroblasts proliferated and matured faster compared with control materials. In in vitro tests a connective tissue capsule was formed around the specimens, and became thinner in the course of time. Foreign body cell reactions in toxicological tests were mild. In experimental bone defects the specimens with a high concentration of small bioactive glass granules (<45 μm) formed a dense apatite surface layer that restricted the bone ingrowth to material. The range of large glass granules (90-315 μm) with high concentrations formed the best bonding with bone, but slow degradation on the copolymer restricted the bone growth only in the superficial layers. In these studies, the handling properties of the material proved to be good and tissue reactions were mild. The reactivity of bioactive glass was retained inside the copolymer matrix, thus enabling bone conductivity with composites. However, the copolymer was noticed to degradate too slowly compared with the bone healing. Therefore, the porosity of the material should be increased in order to improve tissue healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When organic compounds present in biological fluids are analysed by chromatographic methods, it is generally necessary to carry out a prior sample preparation due the high complexity of this type of sample, especially when the compounds to be determinated are found in very low concentrations. This article describes some of the principal methods for sample preparation in analyses of substances present in biological fluids. The methods include liquid-liquid extraction, solid phase extraction, supercritical fluid extraction and extraction using solid and liquid membranes. The advantages and disadvantages of these methods are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we propose a new approach for the determination of the mobility of mercury in sediments based on spatial distribution of concentrations. We chose the Tainheiros Cove, located in the Todos os Santos Bay, Brazil, as the study area, for it has a history of mercury contamination due to a chloro-alkali plant that was active during 12 years. Twenty-six surface sediment samples were collected from the area and mercury concentrations were measured by cold vapour atomic absorption spectrophotometry. A contour map was constructed from the results, indicating that mercury accumulated in a "hot spot" where concentrations reach more than 1 µg g-1. The model is able to estimate mobility of mercury in the sediments based on the distances between iso-concentration contours that determines an attenuation of concentrations factor. Values of attenuation ranged between 0.0729 (East of the hot spot, indicating higher mobility) to 0.7727 (North of the hot spot, indicating lower mobility).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Río Negro Formation (late Miocene-early Pliocene) mainly consists of continental deposits, but it contains a middle member of marine origin. It represents a transgressive-regressive sequence that can be seen at several outcrops along the N Patagonian coast. The taphonomical approach to the El Espigón marine deposits permits the identification of four main layers containing different kinds of skeletal accumulation, which mainly consist of oyster shells [Crassostrea patagonica (D'Orbigny, 1842)]. These concentrations display three different morphologies (pouches, pavements and bouquets) with a different taphonomic signature. These deposits were formed in shallow marine environments influenced by wave activity that produced valve concentrations of different entities. They contain several shell beds that represent event, composite, hiatal to lag skeletal concentrations. Traces of bioturbation in the sediment (Thalassinoides, Teichichnus) and bioerosion on the shells (Entobia, Gastrochaeonolites, Caulostrepsis), and encrusters (cirripeds, bryozoans), are also abundant in the outcrop and consititue common components of these Miocene materials. Layers 1 and 2 of the sequence were deposited in shoreface/foreshore environments at the beginning of a highstand systems tract, while layers 3 and 4 were deposited at the end, or at the beginning of a forced regression, in foreshore environments. A final erosional episode cut the top of the layer 4, which truncated the abundant bioturbaation developed there.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The high variability of CSF volumes partly explains the inconsistency of anesthetic effects, but may also be due to image analysis itself. In this study, criteria for threshold selection are anatomically defined. METHODS: T2 MR images (n = 7 cases) were analyzed using 3-dimentional software. Maximal-minimal thresholds were selected in standardized blocks of 50 slices of the dural sac ending caudally at the L5-S1 intervertebral space (caudal blocks) and middle L3 (rostral blocks). Maximal CSF thresholds: threshold value was increased until at least one voxel in a CSF area appeared unlabeled and decreased until that voxel was labeled again: this final threshold was selected. Minimal root thresholds: thresholds values that selected cauda equina root area but not adjacent gray voxels in the CSF-root interface were chosen. RESULTS: Significant differences were found between caudal and rostral thresholds. No significant differences were found between expert and nonexpert observers. Average max/min thresholds were around 1.30 but max/min CSF volumes were around 1.15. Great interindividual CSF volume variability was detected (max/min volumes 1.6-2.7). CONCLUSIONS: The estimation of a close range of CSF volumes which probably contains the real CSF volume value can be standardized and calculated prior to certain intrathecal procedures

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total sediment and water organic carbon and nutrient (nitrogen and phosphorus) concentrations of different environment types of a Mediterranean coastal wetland (temporary and brackish, temporary and freshwater, semi-permanent and brackish, and permanent and brackish basins) were analysed during two hydroperiods. A nitrogen limitation was found for both sediment and water. The total organic carbon concentration of the water was significantly related to the water level, which varies throughout the hydroperiods. In contrast, the total organic carbon concentration of the sediment was not related to water level. However, significant differences in total organic carbon of the sediment were found between hydroperiods. On the other hand, total organic carbon of the sediment varied spatially, being higher in temporary brackish basins with lower sand content, and lower in permanent and semi-permanent brackish basins with higher sand content

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microenvironment of the central nervous system is important for neuronal function and development. During the early stages of embryo development the cephalic vesicles are filled by embryonic cerebrospinal fluid, a complex fluid containing different protein fractions, which contributes to the regulation of the survival, proliferation and neurogenesis of neuroectodermal stem cells. The protein content of embryonic cerebrospinal fluid from chick and rat embryos at the start of neurogenesis has already been determined. Most of the identified gene products are thought to be involved in the regulation of developmental processes during embryogenesis. However, due to the crucial roles played by embryonic cerebrospinal fluid during brain development, the embryological origin of the gene products it contains remains an intriguing question. According to the literature most of these products are synthesised in embryonic tissues other than the neuroepithelium. In this study we examined the embryological origin of the most abundant embryonic cerebrospinal fluid protein fractions by means of slot-blot analysis and by using several different embryonic and extraembryonic protein extracts, immunodetected with polyclonal antibodies. This first attempt to elucidate their origin is not based on the proteins identified by proteomic methods, but rather on crude protein fractions detected by SDS-PAGE analysis and to which polyclonal antibodies were specifically generated. Despite some of the limitations of this study, i.e. that one protein fraction may contain more than one gene product, and that a specific gene product may be contained in different protein fractions depending on post-translational modifications, our results show that most of the analysed protein fractions are not produced by the cephalic neuroectoderm but are rather stored in the egg reservoir; furthermore, few are produced by embryo tissues, thus indicating that they must be transported from their production or storage sites to the cephalic cavities, most probably via embryonic serum. These results raise the question as to whether the transfer of proteins from these two embryo compartments is regulated at this early developmental stage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to validate a method for the determination of acethaldehyde, methanol, ethanol, acetone and isopropanol employing solid-phase microextraction associated to gas chromatography with flame ionization detection. The operational conditions of SPME were optimized by response surface analysis. The calibration curves for all compounds were linear with r² > 0.9973. Accuracy (89.1-109.0%), intra-assay precision (1.8-8.5%) and inter-assay precision (2.2-8.2%) were acceptable. The quantification limit was 50 µg/mL. The method was applied to the meaurement of ethanol in blood and oral fluid of a group of volunteers. Oral fluid ethanol concentrations were not directly correlated with blood concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Supercritical fluid extraction was used to extract active compounds from the Chinese traditional medicinal D. dasycarpus under the pressure of 30 MPa and temperature of 45 ºC. Further separation and purification was established by high-speed counter-current chromatography (HSCCC) with a two-phase solvent system composed of n-hexane-ethyl acetate-methanol-water (1:0.8:1.3:0.9, volume ratio). The separation yielded a total of 47 mg of dictamnine, 24 mg of obacunone and 83 mg of fraxinellone from 1.0 g of the crude extract in one step separation with the purity of 99.2, 98.4 and 99.0%, respectively, as determined by HPLC. The chemical structures of these compounds were identified by ESI-MS, IR, ¹H-NMR and 13C-NMR.