976 resultados para Esophageal Stenosis
Resumo:
OBJECTIVES: Prospective evaluation of tracheo-carinal airway reconstructions using pedicled extrathoracic muscle flaps for closing airway defects after non-circumferential resections and after carinal resections as part of the reconstruction for alleviation of anastomotic tension. METHODS: From January 1996 to June 2006, 41 patients underwent tracheo-carinal airway reconstructions using 45 extrathoracic muscle flaps (latissimus dorsi, n=25; serratus anterior, n=18; pectoralis major, n=2) for closing airway defects resulting from (a) bronchopleural fistulas (BPF) with short desmoplastic bronchial stumps after right upper lobectomy (n=1) and right-sided (pleuro) pneumonectomy (n=13); (b) right (n=9) and left (n=3) associated with partial carinal resections for pre-treated centrally localised tumours; (c) partial non-circumferential tracheal resections for pre-treated tracheal tumours, tracheo-oesophageal fistulas (TEF) and chronic tracheal injury with tracheomalacia (n=11); (d) carinal resections with the integration of a muscle patch in specific parts of the anastomotic reconstruction for alleviation of anastomotic tension (n=4). The airway defects ranged from 2 x 1 cm to 8 x 4 cm and involved up to 50% of the airway circumference. The patients were followed by clinical examination, repeated bronchoscopy, pulmonary function testing and CT scans. The minimum follow-up time was 6 months. RESULTS: Ninety-day mortality was 7.3% (3/41 patients). Four patients (9.7%) sustained muscle flap necrosis requiring re-operation and flap replacement without subsequent mortality, airway dehiscence or stenosis. Airway dehiscence was observed in 1/41 patients (2.4%) and airway stenosis in 1/38 surviving patients (2.6%) responding well to topical mitomycin application. Follow-up on clinical grounds, by CT scans and repeated bronchoscopy, revealed airtight, stable and epithelialised airways and no recurrence of BPF or TEF in all surviving patients. CONCLUSIONS: Tracheo-carinal airway defects can be closed by use of pedicled extrathoracic muscle flaps after non-circumferential resections and after carinal resections with the muscle patch as part of the reconstruction for alleviation of anastomotic tension.
Resumo:
OBJECTIVES: This study aimed to investigate post-mortem magnetic resonance imaging (pmMRI) for the assessment of myocardial infarction and hypointensities on post-mortem T2-weighted images as a possible method for visualizing the myocardial origin of arrhythmic sudden cardiac death. BACKGROUND: Sudden cardiac death has challenged clinical and forensic pathologists for decades because verification on post-mortem autopsy is not possible. pmMRI as an autopsy-supporting examination technique has been shown to visualize different stages of myocardial infarction. METHODS: In 136 human forensic corpses, a post-mortem cardiac MR examination was carried out prior to forensic autopsy. Short-axis and horizontal long-axis images were acquired in situ on a 3-T system. RESULTS: In 76 cases, myocardial findings could be documented and correlated to the autopsy findings. Within these 76 study cases, a total of 124 myocardial lesions were detected on pmMRI (chronic: 25; subacute: 16; acute: 30; and peracute: 53). Chronic, subacute, and acute infarction cases correlated excellently to the myocardial findings on autopsy. Peracute infarctions (age range: minutes to approximately 1 h) were not visible on macroscopic autopsy or histological examination. Peracute infarction areas detected on pmMRI could be verified in targeted histological investigations in 62.3% of cases and could be related to a matching coronary finding in 84.9%. A total of 15.1% of peracute lesions on pmMRI lacked a matching coronary finding but presented with severe myocardial hypertrophy or cocaine intoxication facilitating a cardiac death without verifiable coronary stenosis. CONCLUSIONS: 3-T pmMRI visualizes chronic, subacute, and acute myocardial infarction in situ. In peracute infarction as a possible cause of sudden cardiac death, it demonstrates affected myocardial areas not visible on autopsy. pmMRI should be considered as a feasible post-mortem investigation technique for the deceased patient if no consent for a clinical autopsy is obtained.
Resumo:
OBJECTIVE: Our objective was to compare two state-of-the-art coronary MRI (CMRI) sequences with regard to image quality and diagnostic accuracy for the detection of coronary artery disease (CAD). SUBJECTS AND METHODS: Twenty patients with known CAD were examined with a navigator-gated and corrected free-breathing 3D segmented gradient-echo (turbo field-echo) CMRI sequence and a steady-state free precession sequence (balanced turbo field-echo). CMRI was performed in a transverse plane for the left coronary artery and a double-oblique plane for the right coronary artery system. Subjective image quality (1- to 4-point scale, with 1 indicating excellent quality) and objective image quality parameters were independently determined for both sequences. Sensitivity, specificity, and accuracy for the detection of significant (> or = 50% diameter) coronary artery stenoses were determined as defined in invasive catheter X-ray coronary angiography. RESULTS: Subjective image quality was superior for the balanced turbo field-echo approach (1.8 +/- 0.9 vs 2.3 +/- 1.0 for turbo field-echo; p < 0.001). Vessel sharpness, signal-to-noise ratio, and contrast-to-noise ratio were all superior for the balanced turbo field-echo approach (p < 0.01 for signal-to-noise ratio and contrast-to-noise ratio). Of the 103 segments, 18% of turbo field-echo segments and 9% of balanced turbo field-echo segments had to be excluded from disease evaluation because of insufficient image quality. Sensitivity, specificity, and accuracy for the detection of significant coronary artery stenoses in the evaluated segments were 92%, 67%, 85%, respectively, for turbo field-echo and 82%, 82%, 81%, respectively, for balanced turbo field-echo. CONCLUSION: Balanced turbo field-echo offers improved image quality with significantly fewer nondiagnostic segments when compared with turbo field-echo. For the detection of CAD, both sequences showed comparable accuracy for the visualized segments.
Resumo:
Early in the 1990s, several case series described adults suffering from dysphagia and children with refractory reflux symptoms, both accompanied by an eosinophil-predominant infiltration, thereby conclusively distinguishing it from gastroesophageal reflux disease. Eosinophilic esophagitis (EoE) was recognized as its own entity in the adult and in the pediatric literature. In the last decade, evidence has accumulated that EoE represents a T-helper (Th)2-type inflammatory disease. Remodeling of the esophagus is a hallmark of EoE, leading to esophageal dysfunction and bolus impaction. Familial occurrence and disease association with single-nucleotide polymorphisms underscore the influence of genetics in this disease. Eosinophilic esophagitis may affect individuals at any age, although the clinical presentation is highly age dependent. There is a significant allergic bias in the EoE population, with the majority of patients having concurrent allergic rhinitis, asthma, eczema, and/or a history of atopy. One noteworthy difference is that in children, EoE seems to be primarily a food antigen-driven disease, whereas in adults, mainly aeroallergen sensitization has been observed. Treatment modalities for EoE include the 3Ds: drugs, diet, and dilation. The crucial question of whether adult and pediatric EoE are different phenotypes of one single entity or whether we are confronted with two different diseases is still open. Here, we review similarities and differences between EoE in adults and children.
Resumo:
Our objective was to evaluate efficacy and patency of metallic stent placement for symptomatic Budd-Chiari syndrome (BCS) due to prothrombotic disorders. Eleven patients with proved BCS due to prothrombotic disorders were referred for endovascular treatment because of refractory ascites (n=9), abdominal pain (n=8), jaundice (n=6), and/or gastrointestinal bleeding (n=4). Stents were inserted for stenosed hepatic vein (n=7), inferior vena cava (n=2), or mesenterico-caval shunt (n=2). Clinical efficacy and stent patency was evaluated by clinical and Doppler follow-up. After a mean follow-up of 21 months, 6 patients had fully patent stents without reintervention (primary stent patency: 55%). Two patients with hepatic vein stenosis had stent thrombosis and died 4 months after procedure. Restenosis occurred in 3 cases (2 hepatic vein and 1 mesenterico-caval shunt stenosis) and were successfully treated by balloon angioplasty (n=2) and addition of new stents (n=1) leading to a 82% secondary stent patency. Of 9 patients with patent stent, 7 were asymptomatic (77%) at the end of the study. Stent placement is a safe and effective procedure to control of symptomatic BCS. Prothrombotic disorder does not seem to jeopardize patency in anticoagulated patients.
Resumo:
BACKGROUND: Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt-chromium drug-eluting stent with silicon carbide-coating releasing sirolimus from a biodegradable polymer (O-SES, Orsiro; Biotronik, Bülach, Switzerland) with the durable polymer-based Xience Prime/Xpedition everolimus-eluting stent (EES) (Xience Prime/Xpedition stent, Abbott Vascular, IL) in an all-comers patient population. DESIGN: The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer sirolimus-eluting stents (SES) or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least 1 lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary end point target lesion failure (TLF) is a composite of cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for noninferiority, inclusion of 2,060 patients would provide more than 80% power to detect noninferiority of the biodegradable polymer SES compared with the durable polymer EES at a 1-sided type I error of 0.05. Clinical follow-up will be continued through 5 years. CONCLUSION: The BIOSCIENCE trial will determine whether the biodegradable polymer SES is noninferior to the durable polymer EES with respect to TLF.
Resumo:
Computer-Aided Tomography Angiography (CTA) images are the standard for assessing Peripheral artery disease (PAD). This paper presents a Computer Aided Detection (CAD) and Computer Aided Measurement (CAM) system for PAD. The CAD stage detects the arterial network using a 3D region growing method and a fast 3D morphology operation. The CAM stage aims to accurately measure the artery diameters from the detected vessel centerline, compensating for the partial volume effect using Expectation Maximization (EM) and a Markov Random field (MRF). The system has been evaluated on phantom data and also applied to fifteen (15) CTA datasets, where the detection accuracy of stenosis was 88% and the measurement accuracy was with an 8% error.
Local re-inversion coronary MR angiography: arterial spin-labeling without the need for subtraction.
Resumo:
PURPOSE: To implement a double-inversion bright-blood coronary MR angiography sequence using a cylindrical re-inversion prepulse for selective visualization of the coronary arteries. MATERIALS AND METHODS: Local re-inversion bright-blood magnetization preparation was implemented using a nonselective inversion followed by a cylindrical aortic re-inversion prepulse. After an inversion delay that allows for in-flow of the labeled blood-pool into the coronary arteries, three-dimensional radial steady-state free-precession (SSFP) imaging (repetition/echo time, 7.2/3.6 ms; flip angle, 120 degrees, 16 profiles per RR interval; field of view, 360 mm; matrix, 512, twelve 3-mm slices) is performed. Coronary MR angiography was performed in three healthy volunteers and in one patient on a commercial 1.5 Tesla whole-body MR System. RESULTS: In all subjects, coronary arteries were selectively visualized with positive contrast. In addition, a middle-grade stenosis of the proximal right coronary artery was seen in one patient. CONCLUSION: A novel T1 contrast-enhancement strategy is presented for selective visualization of the coronary arteries without extrinsic contrast medium application. In comparison to former arterial spin-labeling schemes, the proposed magnetization preparation obviates the need for a second data set and subtraction.
Resumo:
The omega-loop gastric bypass (OLGBP), also called "mini-gastric bypass" or "single-anastomosis" gastric bypass is a form of gastric bypass where a long, narrow gastric pouch is created and anastomosed to the jejunum about 200- 250 cm from the angle of Treitz in an omega loop fashion, thereby avoiding a jejuno-jejunostomy.Proponents of the OLGBP claim that it is a safer and simpler operation than the traditional Roux-en-Y gastric bypass (RYGBP), easier to teach, that gives the same results in terms of weight loss than the RYGBP. One randomized study comparing the two techniques showed similar results after five years.The OLGBP is criticized because it creates an anastomosis between the gastric pouch and the jejunum where a large amount of biliopancreatic juices travel, thereby creating a situation where reflux of the latter into the stomach and distal esophagus is likely to develop. Such a situation has clearly been associated, in several animal studies, with an increased incidence of gastric cancer, especially at or close to the gastro-jejunostomy, and with an increased risk of lower esophageal cancer. In clinical practice, omega-loop gastrojejunostomies such as those used for reconstruction after gastric resection for benign disease or distal gastric cancer have been associated with the so called classical anastomotic cancer, linked to biliary reflux into the stomach, despite the fact that epidemiological studies about this do not show uniform results. Although no evidence at the present time links OLGBP to an increased risk of gastric cancer in the human, this possibility raises a concern among many bariatric surgeons, especially in the view that bariatric surgery is performed in relatively young patients with a long life expectancy, hence prone to develop cancer if indeed the risk is increased. Another arguments used against the OLGBP is that the jejuno-jejunostomy in the traditional RYGBP is easy to perform and associated with virtually no complication.Supporters of the OLGBP claim that the liquid that refluxes into the stomach after their procedure is not pure bile and pancreatic juice, but a combination of those with jejunal secretions, and that the latter is not as harmful. We would urge the proponents of the OLGBP to undertake the necessary animal studies to show that their assumption is indeed true before the procedure is performed widely, possibly leading to the development of hundreds of late gastric or esophageal carcinoma in the bariatric population. In the meantime, we strongly believe that RYGBP should remain the gold standard in gastric bypass surgery for morbid obesity.
Resumo:
PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.
Resumo:
BACKGROUND: Sleeve lobectomy is a valid alternative to pneumonectomy for the treatment of centrally located operable non-small cell lung cancer (NSCLC), but concern has been evoked regarding a potentially increased risk of bronchial anastomosis complications after induction therapy. This study examined the impact of induction therapy on airway healing after sleeve lobectomy for NSCLC. METHODS: Bronchial anastomosis complications were recorded with respect to the induction regimen applied (neoadjuvant chemotherapy vs chemoradiotherapy) in a consecutive series of patients with sleeve lobectomy for NSCLC. RESULTS: Ninety-nine patients underwent sleeve resection, 28 of them after induction therapy. Twelve patients received chemotherapy alone, and 16 patients had radiochemotherapy. There were no significant differences in postoperative 90-day mortality (3.6% vs 2.8%) and morbidity (54% vs 49%) for patients with and without induction therapy. Bronchial anastomosis complications occurred in 3 patients (10.8%) with neoadjuvant therapy and in 2 (2.8%) without (p = 0.3). In the induction therapy group, two bronchial stenoses occurred after radiochemotherapy and one bronchopleural fistula after chemotherapy alone. In patients without induction therapy, one bronchial stenosis and one bronchopleural fistula were observed. All bronchial stenoses were successfully treated by dilatation, and both bronchopleural fistulas occurring after right lower lobectomy were successfully treated by reoperation and completion sleeve bilobectomy with preservation of the upper lobe. CONCLUSIONS: Sleeve lobectomy for NSCLC can be safely performed after induction chemotherapy and radiochemotherapy with mortality and incidence of airway complications similar to that observed in nonpretreated patients. The treatment of airway complications does not differ for patients with and without induction therapy.
Resumo:
This paper addresses primary care physicians, cardiologists, internists, angiologists and doctors desirous of improving vascular risk prediction in primary care. Many cardiovascular risk factors act aggressively on the arterial wall and result in atherosclerosis and atherothrombosis. Cardiovascular prognosis derived from ultrasound imaging is, however, excellent in subjects without formation of intimal thickening or atheromas. Since ultrasound visualises the arterial wall directly, the information derived from the arterial wall may add independent incremental information to the knowledge of risk derived from global risk assessment. This paper provides an overview on plaque imaging for vascular risk prediction in two parts: Part 1: Carotid IMT is frequently used as a surrogate marker for outcome in intervention studies addressing rather large cohorts of subjects. Carotid IMT as a risk prediction tool for the prevention of acute myocardial infarction and stroke has been extensively studied in many patients since 1987, and has yielded incremental hazard ratios for these cardiovascular events independently of established cardiovascular risk factors. However, carotid IMT measurements are not used uniformly and therefore still lack widely accepted standardisation. Hence, at an individual, practicebased level, carotid IMT is not recommended as a risk assessment tool. The total plaque area of the carotid arteries (TPA) is a measure of the global plaque burden within both carotid arteries. It was recently shown in a large Norwegian cohort involving over 6000 subjects that TPA is a very good predictor for future myocardial infarction in women with an area under the curve (AUC) using a receiver operating curves (ROC) value of 0.73 (in men: 0.63). Further, the AUC for risk prediction is high both for vascular death in a vascular prevention clinic group (AUC 0.77) and fatal or nonfatal myocardial infarction in a true primary care group (AUC 0.79). Since TPA has acceptable reproducibility, allows calculation of posttest risk and is easily obtained at low cost, this risk assessment tool may come in for more widespread use in the future and also serve as a tool for atherosclerosis tracking and guidance for intensity of preventive therapy. However, more studies with TPA are needed. Part 2: Carotid and femoral plaque formation as detected by ultrasound offers a global view of the extent of atherosclerosis. Several prospective cohort studies have shown that cardiovascular risk prediction is greater for plaques than for carotid IMT. The number of arterial beds affected by significant atheromas may simply be added numerically to derive additional information on the risk of vascular events. A new atherosclerosis burden score (ABS) simply calculates the sum of carotid and femoral plaques encountered during ultrasound scanning. ABS correlates well and independently with the presence of coronary atherosclerosis and stenosis as measured by invasive coronary angiogram. However, the prognostic power of ABS as an independent marker of risk still needs to be elucidated in prospective studies. In summary, the large number of ways to measure atherosclerosis and related changes in human arteries by ultrasound indicates that this technology is not yet sufficiently perfected and needs more standardisation and workup on clearly defined outcome studies before it can be recommended as a practice-based additional risk modifier.
Resumo:
Une lésion fonctionnelle ou structurale des artérioles intramurales influence le seuil ischémique du myocarde. Le diagnostic de dysfonction microvasculaire est retenu en présence d'une diminution du flux coronaire maximal et de coronaires angio-graphiquement normales ou presque normales. Un trouble de la microcirculation peut traduire une dysfonction endothéliale chez le sujet diabétique ou hyperlipidémique, ou une lésion structurale ou fonctionnelle dans le cadre de la cardiomyopathie hypertrophique, la sténose aortique ou l'hypertension artérielle. Après recanalisation de l'artère responsable d'un infarctus, la mesure de la fonction microcirculatoire permet d'estimer la qualité de la reperfusion myocardique. L'appréciation de la fonction microvasculaire est un enjeu majeur dans l'évaluation de l'ischémie du myocarde en l'absence de sténose coronaire. Functional or structural lesions in intramural arterioles influence the ischemic threshold of the myocardium. Microvascular dysfonction is evidenced by a decrease in coronary blood flow during maximum hyperemia in the presence of angiographically normal or near-normal coronary arteries. Microvascular dysfonction may reflect endothelial dysfonction in diabetic or hyperlipidemic patients, as well as structural and functional changes in patients with hypertrophic cardiomyopathy, aortic stenosis or hypertension. Assessing microvascular fonction after thrombolysis or primary angioplasty for acute myocardial infarction allows to estimate the quality of myocardial reperfusion. Assessing microvascular fonction is a major component of the evaluation of myocardial ischemia in the absence of coronary artery stenoses.
Resumo:
Intimal hyperplasia (IH) is the major cause of stenosis of vein grafts. Drugs such as statins prevent stenosis, but their systemic administration has limited effects. We developed a hyaluronic acid hydrogel matrix, which ensures a controlled release of atorvastatin (ATV) at the site of injury. The release kinetics demonstrated that 100% of ATV was released over 10 hours, independent of the loading concentration of the hydrogel. We investigated the effects of such a delivery on primary vascular smooth muscle cells isolated from human veins. ATV decreased the proliferation, migration, and passage of human smooth muscle cells (HSMCs) across a matrix barrier in a similar dose-dependent (5-10 µM) and time-dependent manner (24-72 hours), whether the drug was directly added to the culture medium or released from the hydrogel. Expression analysis of genes known to be involved in the development of IH demonstrated that the transcripts of both the gap junction protein connexin43 (Cx43) and plasminogen activator inhibitor-1 (PAI-1) were decreased after a 24-48-hour exposure to the hydrogel loaded with ATV, whereas the transcripts of the heme oxygenase (HO-1) and the inhibitor of tissue plasminogen activator were increased. At the protein level, Cx43, PAI-1, and metalloproteinase-9 expression were decreased, whereas HO-1 was upregulated in the presence of ATV. The data demonstrate that ATV released from a hydrogel has effects on HSMCs similar to the drug being freely dissolved in the environment.
Resumo:
BACKGROUND: Gastric banding (GB) is one of the most popular bariatric procedures for morbid obesity. Apart from causing weight loss by alimentary restriction, it can interfere with functions of the esophagus and upper stomach. The aim of this study was to evaluate if the results of extensive preoperative upper GI testing were correlated with long-term outcome and complications after GB. METHODS: Using a prospectively maintained computerized database including all the patients undergoing bariatric operations in both our hospitals, we performed a retrospective analysis of the patients who underwent complete upper gastrointestinal (GI) testing (endoscopy, pH monitoring, and manometry) before GB. RESULTS: One hundred thirty-four patients underwent complete testing before GB. Abnormal pH monitoring (increased total reflux time, increased diurnal reflux time, increased number of reflux episodes) predicted the development of complications and especially pouch dilatation and food intolerance. The mean De Meester score was higher among patients who developed complications than in the remaining ones (25.4 vs 17.7, P=0.03). High lower esophageal sphincter pressure also predicted progressive long-term food intolerance. Endoscopic findings were not predictive of the long-term outcome. CONCLUSIONS: There is some association between the function of the upper digestive tract and long-term complications after gastric banding. Abnormal pH monitoring predicts overall long-term complications, especially food intolerance with or without reflux, and pouch dilatation, and a high lower esophageal sphincter pressure predicts long-term food intolerance. Extended upper gastrointestinal testing with endoscopy, 24-h pH monitoring, and esophageal manometry is probably worthwhile in selecting patients for gastric banding.