988 resultados para Enhanced efficiency fertiliser


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infection by Sugarcane yellow leaf virus (ScYLV) causes severe leaf symptoms in sugarcane (Saccharum spp.) hybrids, which indicate alterations in its photosynthetic apparatus. To gain an overview of the physiological status of infected plants, we evaluated chlorophyll a fluorescence and gas exchange assays, correlating the results with leaf metabolic surveys, i.e., photosynthetic pigments and carbohydrate contents. When compared to healthy plants, infected plants showed a reduction in potential quantum efficiency for photochemistry of photosystem (PSII) and alterations in the filling up of the plastoquinone (PQ) pool. They also showed reduction in the CO2 net exchange rates, probably as a consequence of impaired quantum yield. In addition, reductions were found in the contents of photosynthetic leaf pigments and in the ratio chlorophyll a/chlorophyll b (chla/chlb). Carbohydrate content in the leaves was increased as a secondary effect of the ScYLV infection. This article discusses the relation of virus replication and host defense responses with general alterations in the photosynthetic apparatus and in the metabolism of infected plants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A coupled system simulator, based on analytical circuit equations and a finite element method (FEM) model of the motor has been developed and it is used to analyse a frequency-converterfed industrial squirrel-cage induction motor. Two control systems that emulate the behaviour of commercial direct-torque-controlled (DTC) and vector-controlled industrial frequency converters have been studied, implemented in the simulation software and verified by extensive laboratory tests. Numerous factors that affect the operation of a variable speed drive (VSD) and its energy efficiency have been investigated, and their significance in the simulation of the VSD results has been studied. The dependency of the frequency converter, induction motor and system losses on the switching frequency is investigated by simulations and measurements at different speeds for both the vector control and the DTC. Intensive laboratory measurements have been carried out to verify the simulation results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The capacity of two bacteria isolated from the tomato phylloplane to control late blight (Phytophthora infestans) was investigated in the field, and compared against the effectiveness of spraying with the fungicide chlorothalonil (1.5 g a.i. L-1) or water (control). A 55% reduction in late blight intensity was observed in the leaves of the middle of the plant and 62% in those of the upper leaves when using the antagonist UFV-STB 6 (Novosphingobium capsulatum) as compared to the control. Isolate UFV-IEA 6 (Bacillus cereus) was able to reduce disease intensity by 55%, but only in the upper leaves of the tomato plants. Treatment with isolate UFV-STB 6 also led to a significant reduction in the percentage of fruits with late blight symptoms. The results demonstrate the potential of these two bacteria in controlling this disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experiments were carried out in a growth chamber to evaluate the effect of spreader and uredospore concentrations on the efficiency of infection by Phakopsora pachyrhizi, the causal agent of Asian soybean rust. CD 214 RR soybean cultivar was inoculated with the following polyoxyethylene sorbitane monolaurate concentrations: 0, 30, 60, 120, 240, 480 and 960 µL.L-1 water, as well as a fixed uredospore concentration of 2 x 10(4) spores.mL-1. In a second phase, the inoculum concentrations of 0, 5 x 10³, 1 x 10(4), 2 x 10(4), 4 x 10(4), 8 x 10(4) and 16 x 10(4) uredospores.mL-1 were evaluated, and the spreader concentration of 240 µL.L-1, selected in the previous experiment, was fixed. The spreader concentration of 240 µL.L-1 can be used in artificial inoculation studies, as well as up to 4 x 10(4) uredospores.mL-1. In this work, there was a correlation between uredia and lesion density. Thus, the use of lesion density is recommended to assess disease intensity for its accuracy and less time consuming. There was also a positive correlation between uredia and lesion density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Techniques that result in increased pathogen infection rates by employing reduced quantities of fungal spores with sparse sporulation have been developed. Experiments under controlled environment conditions were conducted to evaluate the effect of the density of Bipolaris sorokiniana conidia on the intensity of wheat helminthosporiosis. Using a selected inoculum density, the concentration of the tensoactive (Tween 20) that promoted maximum infection by the causal agent of the disease was determined. The density of lesions and the estimated severity of the disease were quantified. The selected inoculum density was 1.5 x 10(4) spores.mL-1 plus 480 µL tensoactive.L-1 water, resulting in a disease severity that allows selecting wheat cultivars resistant to B. sorokiniana.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To identify formulations of biological agents that enable survival, stability and a good surface distribution of the antagonistic agent, studies that test different application vehicles are necessary. The efficiency of two killer yeasts, Wickerhamomyces anomalus (strain 422) and Meyerozyma guilliermondii (strain 443), associated with five different application vehicles, was assessed for the protection of postharvest papayas. In this study, after 90 days of incubation at 4ºC, W. anomalus (strain 422) and M. guilliermondii (strain 443) were viable with all application vehicles tested. Fruits treated with different formulations (yeasts + application vehicles) had a decreased severity of disease (by at least 30%) compared with untreated fruits. The treatment with W. anomalus (strain 422) + 2% starch lowered disease occurrence by 48.3%. The most efficient treatments using M. guilliermondii (strain 443) were those with 2% gelatin or 2% liquid carnauba wax, both of which reduced anthracnose by 50% in postharvest papayas. Electron micrographs of the surface tissues of the treated fruits showed that all application vehicles provided excellent adhesion of the yeast to the surface. Formulations based on starch (2%), gelatin (2%) and carnauba wax (2%) were the most efficient at controlling fungal diseases in postharvest papayas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of water removal on press section is very important for a paper and board machine’s functioning, efficiency and economy. Today, the most effective method for wet pressing is shoe press technology. Metso has carried out a number of studies concerning anew type of water removal method for a press section, which has also been patented. These studies include rough sketches and some test runs. These issues form the basis of this thesis. The objective of this work was to gather together information for a new and enhanced waterremoval method for a press section by studying the functioning of the device andcarrying out test runs. This method is referred to here as Hydronip. The main goal was tobuild a functional test site which fulfills all the necessary requirements and has all thenecessary information gathering devices. The design process was carried out by emphasizing the safety aspects. The goal was also to gather together information about the nip structure in running conditions, the seal function, and to carry out the nip tests with paper or board wads. This thesis consists of a theory part, the design and construction of the test site, and carrying out test runs through information gathering. The theory part consists of the principals of water removal from a press section, Hydronip construction, and the requirements for the test place. The safety aspects were taken into account especially in test runs, but also in the assembly stages. The design and construction of the test site includes the selection of equipment and surroundings that are needed for managing the test runs in the best possible way at certain premises. The test site included the equipment that was already on the premises. Some equipment could be used as it was but some equipment had to be manufactured or modified from existing equipment. A functional test site with information gathering devices was accomplished as a result of thethesis. Test runs demonstrated that the Hydronip concept is, at least on a small scale,functional. Short-term tests for seal functioning showed that the seal can be lubricatedsufficiently under different kinds of nip load situations. Wad tests demonstrated that the metal belt is durable against different sizes of external particles. The seal also endured wad tests even though the pressure impacts impaired the lubrication. MTS tests showing dry content increases, combined with a rough cost calculation and the basic function of the machine in test runs, show that with some further study Hydronip could be a promising new product for water removal from a paper or board machine’s press section.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Técnicas de análises de séries temporais são utilizadas para caracterizar o comportamento de fenômenos naturais no domínio do tempo. Neste artigo, segundo a metodologia proposta por Box et al. (1994), 125 observações do Enhanced Vegetation Index (EVI) foram analisadas. Os valores modelados correspondem às variações temporais ocorridas no dossel florestal da reserva biológica de Sooretama, localizada ao Norte do Estado do Espírito Santo, no Município de Linhares. Os resultados indicaram que a metodologia foi adequada. Os resíduos do modelo ajustado são não correlacionados com distribuição normal, média zero e variância s². Com o menor valor do Critério de Informação de Akaike (AIC) -570,51, o modelo ajustado foi o Sazonal Auto-Regressivo Integrado de Médias Móveis (1,0,1)(1,0,1)12.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to verify Point-Centered Quarter Method (PCQM) accuracy and efficiency, using different numbers of individuals by per sampled area, in 28 quarter points in an Araucaria forest, southern Paraná, Brazil. Three variations of the PCQM were used for comparison associated to the number of sampled individual trees: standard PCQM (SD-PCQM), with four sampled individuals by point (one in each quarter), second measured (VAR1-PCQM), with eight sampled individuals by point (two in each quarter), and third measuring (VAR2-PCQM), with 16 sampled individuals by points (four in each quarter). Thirty-one species of trees were recorded by the SD-PCQM method, 48 by VAR1-PCQM and 60 by VAR2-PCQM. The level of exhaustiveness of the vegetation census and diversity index showed an increasing number of individuals considered by quadrant, indicating that VAR2-PCQM was the most accurate and efficient method when compared with VAR1-PCQM and SD-PCQM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential for enhancing the energy efficiency of industrial pumping processes is estimated to be in some cases up to 50 %. One way to define further this potential is to implement techniques in accordance to definition of best available techniques in pumping applications. These techniques are divided into three main categories: Design, control method & maintenance and distribution system. In the theory part of this thesis first the definition of best available techniques (BAT) and its applicability on pumping processes is issued. Next, the theory around pumping with different pump types is handled, the main stress being in centrifugal pumps. Other components needed in a pumping process are dealt by presenting different control methods, use of an electric motor, variable speed drive and the distribution system. Last part of the theory is about industrial pumping processes from water distribution, sewage water and power plant applications, some of which are used further on in the empirical part as example cases. For the empirical part of this study four case studies on typical pumping processes from older Master’s these were selected. Firstly the original results were analyzed by studying the distribution of energy consumption between different system components and using the definition of BAT in pumping, possible ways to improve energy efficiency were evaluated. The goal in this study was that by the achieved results it would be possible to identify the characteristic energy consumption of these and similar pumping processes. Through this data it would then be easier to focus energy efficiency actions where they might be the most applicable, both technically and economically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Approximately a quarter of electrical power consumption in pulp and paper industry is used in different pumping systems. Therefore, improving pumping system efficiency is a considerable way to reduce energy consumption in different processes. Pumping of wood pulp in different consistencies is common in pulp and paper industry. Earlier, centrifugal pumps were used to pump pulp only at low consistencies, but development of MC technology has made it possible to pump medium consistency pulp. Pulp is a non-Newtonian fluid, which flow characteristics are significantly different than what of water. In this thesis is examined the energy efficiency of pumping medium consistency pulp with centrifugal pump. The factors effecting the pumping of MC pulp are presented and through case study is examined the energy efficiency of pumping in practice. With data obtained from the case study are evaluated the effects of pump rotational speed and pulp consistency on energy efficiency. Additionally, losses caused by control valve and validity of affinity laws in pulp pumping are evaluated. The results of this study can be used for demonstrating the energy consumption of MC pumping processes and finding ways to improve energy efficiency in these processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined solution business models and how they could be applied into energy efficiency business. The target of this study was to find out, what a functional solution business model applied to energy efficiency improvement projects is like. The term “functionality” was used to refer not only to the economic viability but to environmental and legal aspects and also to the implement of Critical Success Factors (CSFs) and the ability to overcome the most important market barriers and risks. This thesis is based on a comprehensive literature study on solution business, business models and energy efficiency business. This literature review was used as a foundation to an energy efficiency solution business model scheme. The created scheme was tested in a case study which studied two different energy efficiency improvement projects, illustrated the functionality of the created business model and evaluated their potential as customer targets. Solution approach was found to be suitable for energy efficiency business. The most important characteristics of a good solution business model were identified to be the relationship between the supplier and customer, a proper network, knowledge on the customer’s process and supreme technological expertise. Thus the energy efficiency solution business was recognized to be particularly suitable for example for energy suppliers or technological equipment suppliers. Because the case study was not executed from a certain company’s point of view, the most important factors such as relationships and the availability of funding could not be evaluated. Although the energy efficiency business is recognized to be economically viable, the most important factors influencing the profitability and the success of energy efficiency solution business model were identified to be the proper risk management, the ability to overcome market barriers and the realization of CSFs.