988 resultados para Electrochemical Testing
Resumo:
Sixty cattle farmers in England were questioned about the costs associated with premovement testing for bovine tuberculosis (TB). On average, the farmers had premovement tested 2-45 times in the previous 12 months, but the majority had tested only once. An average of 28.6 animals were tested on each occasion, but there were wide variations. The average farm labour costs were (sic)4.00 per animal tested, veterinary costs were (sic)4.33 and other costs were (sic)0.51, giving a total cost of (sic)8.84, but there were wide variations between farms, and many incurred costs of more than (sic)20 per animal. A majority of the farmers also cited disruption to the farm business or missed market opportunities as costs, but few could estimate their financial cost. Most of the farmers thought that premovement testing was a cost burden on their business, and over half thought It was not an effective policy to control bovine TB.
Resumo:
In this paper we review the experimental development of agri-environment measures for use on grasslands. Sward structure has been shown to have a strong influence on birds' ability to forage in grasslands, but the effects of food abundance on foraging behaviour are poorly understood and this hinders development of grassland conservation measures. The experiments described have a dual purpose: to investigate the foraging ecology of birds on grasslands and to test candidate management measures. Most of the work featured focuses on increasing invertebrate food resources during the summer by increasing habitat heterogeneity. We also identify important gaps in the habitats provided by existing or experimental measures, where similar dual-purpose experiments are required.
Resumo:
Conventional seemingly unrelated estimation of the almost ideal demand system is shown to lead to small sample bias and distortions in the size of a Wald test for symmetry and homogeneity when the data are co-integrated. A fully modified estimator is developed in an attempt to remedy these problems. It is shown that this estimator reduces the small sample bias but fails to eliminate the size distortion.. Bootstrapping is shown to be ineffective as a method of removing small sample bias in both the conventional and fully modified estimators. Bootstrapping is effective, however, as a method of removing. size distortion and performs equally well in this respect with both estimators.
Resumo:
The conventional method for assessing acute oral toxicity (OECD Test Guideline 401) was designed to identify the median lethal dose (LD50), using the death of animals as an endpoint. Introduced as an alternative method (OECD Test Guideline 420), the Fixed Dose Procedure (FDP) relies on the observation of clear signs of toxicity, uses fewer animals and causes less suffering. More recently, the Acute Toxic Class method and the Up-and-Down Procedure have also been adopted as OECD test guidelines. Both of these methods also use fewer animals than the conventional method, although they still use death as an endpoint. Each of the three new methods incorporates a sequential dosing procedure, which results in increased efficiency. In 1999, with a view to replacing OECD Test Guideline 401, the OECD requested that the three new test guidelines be updated. This was to bring them in line with the regulatory needs of all OECD Member Countries, provide further reductions in the number of animals used, and introduce refinements to reduce the pain and distress experienced by the animals. This paper describes a statistical modelling approach for the evaluation of acute oral toxicity tests, by using the revised FDP for illustration. Opportunities for further design improvements are discussed.
Resumo:
Assaying a large number of genetic markers from patients in clinical trials is now possible in order to tailor drugs with respect to efficacy. The statistical methodology for analysing such massive data sets is challenging. The most popular type of statistical analysis is to use a univariate test for each genetic marker, once all the data from a clinical study have been collected. This paper presents a sequential method for conducting an omnibus test for detecting gene-drug interactions across the genome, thus allowing informed decisions at the earliest opportunity and overcoming the multiple testing problems from conducting many univariate tests. We first propose an omnibus test for a fixed sample size. This test is based on combining F-statistics that test for an interaction between treatment and the individual single nucleotide polymorphism (SNP). As SNPs tend to be correlated, we use permutations to calculate a global p-value. We extend our omnibus test to the sequential case. In order to control the type I error rate, we propose a sequential method that uses permutations to obtain the stopping boundaries. The results of a simulation study show that the sequential permutation method is more powerful than alternative sequential methods that control the type I error rate, such as the inverse-normal method. The proposed method is flexible as we do not need to assume a mode of inheritance and can also adjust for confounding factors. An application to real clinical data illustrates that the method is computationally feasible for a large number of SNPs. Copyright (c) 2007 John Wiley & Sons, Ltd.
Resumo:
Amid the flurry of grant writing and experimentation, statistical analysis sometimes gets less attention than it requires. Here, we describe fully the considerations that should go into the employment of the statistical two-sample t test.
Resumo:
This paper considers methods for testing for superiority or non-inferiority in active-control trials with binary data, when the relative treatment effect is expressed as an odds ratio. Three asymptotic tests for the log-odds ratio based on the unconditional binary likelihood are presented, namely the likelihood ratio, Wald and score tests. All three tests can be implemented straightforwardly in standard statistical software packages, as can the corresponding confidence intervals. Simulations indicate that the three alternatives are similar in terms of the Type I error, with values close to the nominal level. However, when the non-inferiority margin becomes large, the score test slightly exceeds the nominal level. In general, the highest power is obtained from the score test, although all three tests are similar and the observed differences in power are not of practical importance. Copyright (C) 2007 John Wiley & Sons, Ltd.
Resumo:
Electrochemical determination of redox active dye species is demonstrated in indigo samples contaminated with high levels of organic and inorganic impurities. The use of a hydrodynamic electrode system based on a vibrating probe (250 Hz, 200 mu m lateral amplitude) allows time-independent diffusion controlled signals to be enhanced and reliable concentration data to be obtained under steady state conditions at relatively fast scan rates up to 4 V s-1In this work the indigo content of a complex plant-derived indigo sample (dye content typically 30%) is determined after indigo is reduced by addition of glucose in aqueous 0.2 M NaOH. The soluble leuco-indigo is measured by its oxidation response at a vibrating electrode. The vibrating electrode, which consisted of a laterally vibrating 500 mu m diameter gold disc, is calibrated with Fe(CN)(6) 3-/4- in 0.1 M KCl and employed for indigo determination at 55, 65, and 75 C in 0.2 M NaOH. Determinations of the indigo content of 25 different samples of plant-derived indigo are compared with those obtained by conventional spectrophotometry. This comparison suggests a significant improvement by the electrochemical method, which appears to be less sensitive to impurities.
Resumo:
The reduction of indigo (dispersed in water) to leuco-indigo (dissolved in water) is an important industrial process and investigated here for the case of glucose as an environmentally benign reducing agent. In order to quantitatively follow the formation of leuco-indigo two approaches based on (i) rotating disk voltammetry and (ii) sonovoltammetry are developed. Leuco-indigo, once formed in alkaline solution, is readily monitored at a glassy carbon electrode in the mass transport limit employing hydrodynamic voltammetry. The presence of power ultrasound further improves the leuco-indigo determination due to additional agitation and homogenization effects. While inactive at room temperature, glucose readily reduces indigo in alkaline media at 65 degrees C. In the presence of excess glucose, a surface dissolution kinetics limited process is proposed following the rate law d eta(leuco-indigo)/dt = k x c(OH-) x S-indigo where eta(leuco-indigo) is the amount of leuco-indigo formed, k = 4.1 x 10(-9) m s(-1) (at 65 degrees C, assuming spherical particles of I gm diameter) is the heterogeneous dissolution rate constant,c(OH-) is the concentration of hydroxide, and Sindigo is the reactive surface area. The activation energy for this process in aqueous 0.2 M NaOH is E-A = 64 U mol(-1) consistent with a considerable temperature effects. The redox mediator 1,8-dihydroxyanthraquinone is shown to significantly enhance the reaction rate by catalysing the electron transfer between glucose and solid indigo particles. (c) 2006 Elsevier Ltd. All fights reserved.
Resumo:
We discuss the utility of single nucleotide polymorphism loci for full trio and mother-unavailable paternity testing cases, in the presence of population substructure and relatedness of putative and actual fathers. We focus primarily on the expected number of loci required to gain specified probabilities of mismatches, and report the expected proportion of paternity indices greater than three threshold values for these loci. (c) 2004 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Groundwater is an important resource in the UK, with 45% of public water supplies in the Thames Water region derived from subterranean sources. In urban areas, groundwater has been affected by onthropogenic activities over 0 long period of time and from a multitude of sources, At present, groundwater quality is assessed using a range of chemical species to determine the extent of contamination. However, analysing a complex mixture of chemicals is time-consuming and expensive, whereas the use of an ecotoxicity test provides information on (a) the degree of pollution present in the groundwater and (b) the potential effect of that pollution. Microtox (TM), Eclox (TM) and Daphnia magna microtests were used in conjunction with standard chemical protocols to assess the contamination of groundwaters from sites throughout the London Borough of Hounslow and nearby Heathrow Airport. Because of their precision, range of responses and ease of use, Daphnia magna and Microfox (TM) tests are the bioassays that appear to be most effective for assessing groundwater toxicity However, neither test is ideal because it is also essential to monitor water hardness. Eclox (TM) does not appear to be suitable for use in groundwater-quality assessment in this area, because it is adversely affected by high total dissolved solids and electrical conductivity.
Resumo:
Reaction of a group of N-(2'-hydroxyphenyl)benzaldimines, derived from 2-aminophenol and five para-substituted benzaldehydes (the para substituents are OCH3, CH3, H, Cl and NO2), with [Rh(PPh3)(3)Cl] in refluxing toluene in the presence of a base (NEW afforded a family of organometallic complexes of rhodium(III). The crystal structure of one complex has been determined by X-ray crystallography. In these complexes the benzaldimine ligands are coordinated to the metal center, via dissociation of the phenolic proton and the phenyl proton at the ortho position of the phenyl ring in the imine fragment, as dianionic tridentate C,N,O-donors, and the two PPh3 ligands are trans. The complexes are diamagnetic (low-spin d(6), S = 0) and show intense MLCT transitions in the visible region. Cyclic voltammetry shows a Rh(III)-Rh(IV) oxidation within 0.63-0.93 V vs SCE followed by an oxidation of the coordinated benzaldimine ligand. A reduction of the coordinated benzaldimine is also observed within -0.96 to -1.04 V vs SCE. Potential of the Rh(Ill)-Rh(IV) oxidation is found to be sensitive to the nature of the para-substituent. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
A family of oxorhenium (V) complexes of newly designed pyridylthioazophenolate ligands has been synthesized and isolated in pure form. The solid state structure of an organic compound (HL1) has been established by X-ray crystallography. The molecular structure observed in the solid state is that the two molecules of the ligand (HL1) in the asymmetric unit have similar geometries, except for the orientation of the pyridine ring. This series of organic moieties acts as tetradentate monobasic NSNO donor chelators in oxorhenium(V) complexes which has been characterized by elemental analyses, IR, H-1-NMR, UV-Vis. The complexes are 1: 1 electrolytes in nature in MeOH solution, the counter anion being ClO4). The electrochemical studies of the [(ReO)-O-V(L)Cl]ClO4 complexes in MeCN using TBAP as supporting electrolyte exhibit quasi-reversible voltammogram showing one-electron couple for [(ReO)-O-VI(L)Cl](2+)-[(ReO)-O-V(L)Cl](+) in the 1.11-1.29 V vs SCE range.
Resumo:
A series of fourteen novel pyrrole monomers substituted at the 3-position with aliphatic and aromatic crown-ether moieties have been synthesised in good yield and characterised extensively. Several of these compounds were electropolymerised successfully in acetonitrile, using both potentiostatic and galvanostatic modes and the electrochemical properties of those systems were studied via cyclic voltammetry in aqueous and organic media. Novel crown-ether substituted polypyrrole derivatives revealed reversible redox couples in LiClO4/CH3CN (0.1 M). The morphology of these novel crown-ether substituted polypyrrole derivatives was characterised by scanning electron microscopy. These polymers exhibited an open porous structure and half the charge was required when compared to polypyrrole to afford films of equal thickness. The mass change during polymerisation was followed by electrochemical quartz crystal microbalance measurement, and the rate of polymer growth was found to be nonlinear when compared to polypyrrole. (c) 2005 Elsevier B.V. All rights reserved.