945 resultados para Compression ignition (CI)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas of non-interacting particles diffuses in a lattice of pulsating scatterers. In the finite-horizon case with bounded distance between collisions and strongly chaotic dynamics, the velocity growth (Fermi acceleration) is well described by a master equation, leading to an asymptotic universal non-Maxwellian velocity distribution scaling as v∼t. The infinite-horizon case has intermittent dynamics which enhances the acceleration, leading to v∼t ln t and a non-universal distribution. © Copyright EPLA, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reciclagem de plásticos tem sido uma possibilidade interessante para minimizar o problema de destino dos resíduos plásticos. O polipropileno (PP) está entre os tipos de polímeros de maior consumo, portanto a reutilização deste material tem possibilitado o desenvolvimento de estudos de grande relevância científica e social. Este polímero apresenta excelente relação custo/benefício, além de ser facilmente conformável e exibir propriedades mecânicas que o torna útil em várias aplicações. Entretanto, esse material ao ser queimado gera produtos que agem como combustíveis de modo que, para alguns usos, boa resistência à chama é necessária. Isso pode ser obtido pela adição de retardante de chama, que tem o propósito de aumentar a resistência desse material à ignição e, ao mesmo tempo, reduzir a velocidade de propagação da chama. O hidróxido de alumínio, ou simplesmente hidrato de alumina, é o agente retardante de chama mais utilizado no mercado, pois, age também como supressor de fumaça e não libera gases tóxicos durante a queima. No entanto, para tais propriedades, altas concentrações de alumina hidratada são necessárias. Isto causa deterioração nas propriedades físicas dos materiais, por não ter caráter reforçante. As fibras naturais possuem boa capacidade de reforço quando combinadas adequadamente com polímeros. Apresentando também vantagens como baixo custo, baixa densidade, biodegradabilidade e na combustão não emana gases tóxicos. Neste trabalho, misturas contendo alumina hidratada e fibras de coco foram incorporadas ao polipropileno com o objetivo de se encontrar um balanço adequado de propriedades para utilização deste compósito com características de resistência à chama e desempenho mecânico. Os compósitos foram moldados por compressão a quente e caracterizados por IV, DRX, MEV, testes mecânicos e de inflamabilidade. Foi observado aumento no módulo de elasticidade dos compósitos em geral, bem como aumento na resistência a tenacidade do compósito PP/fibra de coco em relação ao PP puro. Os resultados indicaram a eficiência da alumina hidratada como antichama, em todos os compósitos, exceto PP/F, classificando os materiais como V-0 segundo a norma internacional UL 94V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Venous ulcers have a significant impact on patient quality of life, and constitute a worldwide public health problem. Treatment is complex, with high failure rates.OBJECTIVES: To identify clinical and therapeutic factors that influence healing of venous ulcers.METHODS: Retrospective cohort study of patients with venous ulcers. Ulcer area was measured at the first visit (T0) and after 6 months (T6) and 1 year (T12). A reduction in ulcer area of 50% or more at T6 and T12 was the outcome of interest, weighted by clinical, demographic and treatment aspects.RESULTS: Ninety-four patients were included (137 ulcers). A reduction in ulcer area of 50% or more was seen in 40.1% of patients (95% CI 31.9 to 48.4%) at T6 and 49.6% (95% CI 41.2 to 58.1%) at T12. Complete healing occurred in 16.8% (95% CI 10.5 to 23.1%) at T6 and 27% (95% CI 19.5 to 39.5%) at T12. The lowest ulcer area reductions at T6 were associated with longstanding ulcer (RR=0.95; 95% CI 0.91 to 0.98), poor adherence to compression therapy (RR=4.04; 95% CI 1.31 to 12.41), and infection episodes (RR=0.42; 95% CI 0.23 to 0.76). At T12, lower reductions were associated with longstanding ulcer (RR=0.95; 95% CI 0.92 to 0.98), longer topical antibiotic use (RR=0.93; 95% CI 0.87 to 0.99), and systemic antibiotic use (RR=0.63; 95% CI 0.40 to 0.99).CONCLUSIONS: Longstanding ulcer, infection, poor adherence to compression therapy, and longer topical and systemic antibiotic use were independently correlated with worse healing rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SynopsisBackgroundCellulite refers to changes in skin relief on the thighs and buttocks of women, with a prevalence of 80-90%, causing dissatisfaction and search for treatment. Etiopathogenesis is multifactorial, as follows: herniation of the hypodermis towards the dermis, facilitated by perpendicular fibrous septa, changes in the dermal extracellular matrix, decreased adiponectin, genetic polymorphism, microcirculation alterations and inflammatory process. There are numerous therapeutic approaches, with little evidence of effectiveness. The long-wave infrared (LWIR) radiation interacts with water, improves microcirculation and stimulates metabolic processes. To date, the use of tissues with potential reflection of LWIR radiation has not been systematically investigated as adjuvant treatment for cellulite.ObjectiveTo investigate the efficacy and safety of the treatment of cellulite through the use of compression stockings made with thread reflecting LWIR radiation.Patients and methodsClinical study of therapeutic intervention, controlled and double-blind, including 30 women, aging from 25 to 40years, with cellulite of grades II and III on the thighs and buttocks who used compression stockings, pantyhose model, made with reflector thread of LWIR radiation, on only one randomized side. Women under other treatments for cellulite and with venous and/or blood insufficiencies were excluded. Evaluation of efficacy by clinical parameters, photographs, Dermatology Life Quality Index (DLQI), cutometry and high frequency ultrasonography and security by observation of adverse events and venous EcoDoppler recordings.ResultsDLQI scores showed significant reduction; the two-dimensional high-frequency ultrasonography showed an insignificant increase in dermal echogenicity as well as other efficacy parameters demonstrated no or slight improvement, with no differences between the sides exposed or not to LWIR; and there were no severe adverse events.ConclusionCompression stockings, with or without thread reflector of LWIR, showed slight effects in the appearance of cellulite, but the treatment determined a positive impact on women quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Brazil, due to its availability, sugar cane bagasse has a high potential for power generation. The knowledge of ignition behavior, as well as the knowledge of the chemical kinetics, in of fuels combustion process is important features in boilers projects and in the stability of the combustion process control. The aim of this study is to investigate the thermal behavior of sugar cane bagasse, coal and their blends. The methodology proposed by Tognotti et al. (1985) was applied to determine the ignition temperature for all samples. Ignition temperatures were 256oC for neat bagasse and 427oC for neat coal, and 275oC for both blends (50-50% and 25-75%). The ModelFree Kinetics was applied to determine the apparent activation energy (Eα) of the thermal decomposition of sugar cane bagasse. For the two major events of mass loss of bagasse which correspond to the thermal decomposition of organic matter (mainly hemicellulose, cellulose and lignin), average values of Eα were obtained for both combustion and pyrolysis processes. In synthetic air atmosphere, the Eα were 170.8±26.3 kJ⋅mol-1 and 277.8±58.6 kJ⋅mol-1, while in nitrogen atmosphere, the Eα were 185.0 ± 11.4 kJ⋅mol-1 and 82.1±44.4 kJ⋅mol-1. The results obtained can be explained by synergistic effects when both bagasse and coal were blended, changing the fuel reactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Internationally there are validated instruments that are used on a large scale to verify the information literacy of individuals in different contexts. Their results serve as a diagnostic for the planning and implementation of information literacy activities. In Brazil there is no validated assessment tools of information literacy. An analysis of contents of four international instruments attached to the upper level educational institutions duly recognized in the literature of the field and validated. The results will be presented related to information literacy addressed in these instruments. It was found that the instruments analyzed the skills focused on the identification of terms of the informational needs, the preparation and construction of search strategies available in parameter two of the Association of College and Research Libraries; differentiation of information sources (parameter one); evaluation and selection of informational sources and selection of the theme searched information (parameter three); and, finally, the abilities of the ethical issue related to use of the information (parameter five). The parameter four, which is facing the communication of information, was not addressed by the instruments. It was concluded that there is a concern of those responsible for preparing the instruments covered with more traditional technical aspects of training users and aspects of information literacy at the expense of ethical and aesthetic aspects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The centrifuge technique was used to investigate the influence of particle size, applied compression, and substrate material (stainless steel, glass, Teflon, and poly(vinyl chloride)) on particle-surface adhesion force. For this purpose, phosphatic rock (rho(p) = 3090 kg/m(3)) and manioc starch particles (rho(p) = 1480 kg/m(3)) were used as test particles. A microcentrifuge that reached a maximum rotation speed of 14 000 rpm and which contained specially designed centrifuge tubes was used in the adhesion force measurements. The curves showed that the adhesion force profile followed a normal log distribution. The adhesion force increased linearly with particle size and with the increase of each increment of compression force. The manioc starch particles presented greater adhesion forces than the phosphatic rock particles for all particle sizes studied. The glass substrate showed a higher adherence than the other materials, probably due to its smoother topographic surface roughness in relation to the other substrata.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Chyle fistulas may occur after left neck dissections that include level IV, due to injury of the thoracic duct or of 1 of its major branches. Despite being unusual, this complication carries substantial postoperative morbidity and even mortality. So far, no effective intraoperative maneuver has been reported to detect this fistula at the end of a neck dissection. In this cohort study, we sought to describe a simple new maneuver, intraoperative abdominal compression, which can effectively help to identify an open major lymphatic duct on level IV at the end of a neck dissection. Patients and Methods From March 1989 to September 2010, 206 patients underwent neck dissections involving left level IV, and underwent intraoperative abdominal compression. There were 119 men and 87 women, with ages ranging from 18 to 81 years (median, 52 years). One hundred forty-four patients had squamous cell carcinomas, 54 had thyroid carcinomas, 5 had malignant melanomas, and 3 had salivary cancers. Distribution by type of left neck dissection was: selective including levels II, III, and IV (73 cases; 35.4%), selective including levels II, III, IV, and V (55 cases; 26.6%), selective including levels I, II, III, and IV (12 cases; 5.8%), modified radical (47 cases; 22.8%), and radical (19 cases; 9.2%). In all cases, at the end of the procedure, the endotracheal tube was temporarily disconnected from the ventilator. Keeping the dissected level IV area under clear visualization, an abdominal compression was performed. At this moment, any detected lymphatic leak was carefully clamped and tied with nonabsorbable sutures. After ventilating the patient, the intraoperative abdominal compression was repeated to reassure complete occlusion of the lymphatic vessel. Results In 13 cases (6.3%), a chyle leak was detected after performing the intraoperative abdominal compression. All leaks except for 2 were successfully controlled after 1 attempt. In these 2 patients, a patch of muscle and fat tissue was applied with fibrin glue on the top. In 1 of these patients, another chyle leak in a different location was detected only at the second intraoperative abdominal compression, and was also effectively closed. Postoperatively, there were 2 (1%) chyle fistulas, both among these 13 cases, and all were successfully managed with clinical measures only. No fistulas occurred among the remaining 193 patients in whom intraoperative abdominal compression did not demonstrate lymphatic leak. Conclusion To our knowledge, this is the first description of a specific maneuver to actively detect a lymphatic fistula at the end of a left neck dissection involving level IV. In this study, intraoperative abdominal compression was able to detect an open lymphatic vessel in 6.3% of the cases, as well as to assure its effective sealing in the remaining 93.7% of the patients. Moreover, no life-threatening high-volume fistula was noted in this study. (C) 2012 Wiley Periodicals, Inc. Head Neck, 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During orthodontic tooth movement (OTM), alveolar bone is resorbed by osteoclasts in compression sites (CS) and is deposited by osteoblasts in tension sites (TS). The aim of this study was to develop a standardized OTM protocol in mice and to investigate the expression of bone resorption and deposition markers in CS and TS. An orthodontic appliance was placed in C57BL6/J mice. To define the ideal orthodontic force, the molars of the mice were subjected to forces of 0.1 N, 0.25 N, 0.35 N and 0.5 N. The expression of mediators that are involved in bone remodeling at CS and TS was analyzed using a Real-Time PCR. The data revealed that a force of 0.35 N promoted optimal OTM and osteoclast recruitment without root resorption. The levels of TNF-alpha, RANKL, MMP13 and OPG were all altered in CS and TS. Whereas TNF-a and Cathepsin K exhibited elevated levels in CS. RUNX2 and OCN levels were higher in TS. Our results suggest that 0.35 N is the ideal force for OTM in mice and has no side effects. Moreover, the expression of bone remodeling markers differed between the compression and the tension areas, potentially explaining the distinct cellular migration and differentiation patterns in each of these sites. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. The aim of this study was to evaluate whether an association of elastic stockings and walking for a short period in the late afternoon reduces leg edema. Methods. Volume changes of the legs of sixteen patients (32 limbs), who walked on a treadmill for 30 minutes using elastic compression stockings, were analyzed in a quantitative, cross-over randomized (in order of arrival at the clinic) study. They were submitted to volumetry using the water displacement technique and subsequently required to put on 20/30 made-to-measure compression stockings (Sigvaris). The patients walked on a treadmill for 30 minutes and after removing the stockings volumetry of the legs was again performed. Legs were assessed using the CEAP classification and divided into groups. Analysis of variance was used for statistical analysis with an alpha error of 5% being considered acceptable. Results. When participants walked wearing compression stockings, there was a reduction in leg volume. When the CEAP classification was evaluated, it was noted that there was a statistically significant difference for the CEAP C0, C1 and C2 categories of legs using stockings compared to those that did not use. Conclusion. Compression stockings have a synergistic effect with walking in the late afternoon thus reducing edema of the lower limbs. [Int Angiol 2012;31:490-3]