999 resultados para Code validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Psicologia (Psicologia da Social), Universidade de Lisboa, Faculdade de Psicologia, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Nursing and Midwifery Council, the United Kingdom regulator of nursing and midwifery has recently revised its professional code of practice. This paper begins by arguing that a professional code must be capable of sustaining close reading and of action guidance. Using four exemplar clauses it is argued that the new revised code does not met this purpose. First, I show that in setting out requirements for consent and documentation, the meaning of the relevant clause has changed significantly during the editing process so that a literal reading of the final document bears little relation to established professional practice. Second, I argue that the clause concerning the nature of professional relationships has also been altered during the editing process so that it is inconsistent with other professional groups and established accounts of the professional nurse-patient relationship. Third, I argue that the clause concerning disclosure of confidential information, which survived revision and editing with its meaning intact is nevertheless factually incorrect and inconsistent with UK law and authoritative guidance. Finally, fourth, I argue that use of the word ‘inappropriate’ is inappropriate as it amounts to meaningless circularity, discussed in relation to a clause on expressing personal beliefs. Taken together, these examples demonstrate that the Code is seriously flawed and does not fulfil its purpose. One way that simple prescriptive clauses in the Code can be usefully understood is through the provision of detailed guidance. I argue that the NMC has changed its position on its view of the value of guidance and has significantly reduced the amount of written guidance and advice is provides. The paper concludes by arguing that in order to meet its action directing function, further clarifying revision and the provision of detailed guidance is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Grid Execution Management for Legacy Code Architecture (GEMLCA) enables exposing legacy applications as Grid services without re-engineering the code, or even requiring access to the source files. The integration of current GT3 and GT4 based GEMLCA implementations with the P-GRADE Grid portal allows the creation, execution and visualisation of complex Grid workflows composed of legacy and nonlegacy components. However, the deployment of legacy codes and mapping their execution to Grid resources is currently done manually. This paper outlines how GEMLCA can be extended with automatic service deployment, brokering, and information system support. A conceptual architecture for an Automatic Deployment Service (ADS) and for an x-Service Interoperability Layer (XSILA) are introduced explaining how these mechanisms support desired features in future releases of GEMLCA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-parametric magnetic resonance imaging (mp-MRI) has become an increasingly important method for detecting and treating prostate cancer. Transrectal ultrasound (TRUS) is the most commonly used method for guiding prostate needle biopsy and remains the gold standard for diagnosis of prostate cancer. MRI-to-TRUS image reg- istration is an important technology for enabling computer-assisted targeting of the majority of prostate lesions that are visible in MRI but not independently distinguishable in TRUS images. The aim of this study was to estimate the needle placement accuracy of an image guidance system (SmartTargetÒ), developed by our research group, using a surgical training phantom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Central obesity is the hallmark of a number of non-inheritable disorders. The advent of imaging techniques such asMRI has allowed for a fast and accurate assessment of body fat content and distribution. However, image analysis continues to be one of the major obstacles to the use of MRI in large-scale studies. In this study we assess the validity of the recently proposed fat–muscle quantitation system (AMRATM Profiler) for the quantification of intra-abdominal adipose tissue (IAAT) and abdominal subcutaneous adipose tissue (ASAT) from abdominal MR images. Abdominal MR images were acquired from 23 volunteers with a broad range of BMIs and analysed using sliceOmatic, the current gold-standard, and the AMRATM Profiler based on a non-rigid image registration of a library of segmented atlases. The results show that there was a highly significant correlation between the fat volumes generated by the two analysis methods, (Pearson correlation r = 0.97, p < 0.001), with the AMRATM Profiler analysis being significantly faster (~3 min) than the conventional sliceOmatic approach (~40 min). There was also excellent agreement between the methods for the quantification of IAAT (AMRA 4.73 ± 1.99 versus sliceOmatic 4.73 ± 1.75 l, p = 0.97). For the AMRATM Profiler analysis, the intra-observer coefficient of variation was 1.6% for IAAT and 1.1% for ASAT, the inter-observer coefficient of variationwas 1.4%for IAAT and 1.2%for ASAT, the intra-observer correlationwas 0.998 for IAAT and 0.999 for ASAT, and the inter-observer correlation was 0.999 for both IAAT and ASAT. These results indicate that precise and accurate measures of body fat content and distribution can be obtained in a fast and reliable form by the AMRATM Profiler, opening up the possibility of large-scale human phenotypic studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Orientador: Mestre Alberto Couto

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An accurate and sensitive method for determination of 18 polycyclic aromatic hydrocarbons (PAHs) (16 PAHs considered by USEPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) in fish samples was validated. Analysis was performed by microwave-assisted extraction and liquid chromatography with photodiode array and fluorescence detection. Response surface methodology was used to find the optimal extraction parameters. Validation of the overall methodology was performed by spiking assays at four levels and using SRM 2977. Quantification limits ranging from 0.15–27.16 ng/g wet weight were obtained. The established method was applied in edible tissues of three commonly consumed and commercially valuable fish species (sardine, chub mackerel and horse mackerel) originated from Atlantic Ocean. Variable levels of naphthalene (1.03–2.95 ng/g wet weight), fluorene (0.34–1.09 ng/g wet weight) and phenanthrene (0.34–3.54 ng/g wet weight) were detected in the analysed samples. None of the samples contained detectable amounts of benzo[a]pyrene, the marker used for evaluating the occurrence and carcinogenic effects of PAHs in food.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A CIF é uma ferramenta universal desenvolvida pela OMS que permite a classificação de funcionalidade e incapacidade, através de uma visualização global do que condiciona o desempenho do indivíduo na concretização de atividades e na participação em ocupações. A ideologia da CIF e os seus componentes interrelacionam-se com a essência da TO, indo ao encontro dos modelos da profissão. As UCCI constituem uma atualidade em Portugal e o terapeuta ocupacional é um dos profissionais obrigatórios na equipa multidisciplinar destas unidades. Atendendo à relevância internacional da CIF, à sua ligação com a TO e à necessidade de tornar a CIF operacional na prática clínica diária dado que é uma ferramenta complexa e extensa, é objetivo deste estudo contribuir para a construção de um code set da CIF para terapeutas ocupacionais que exercem funções em UCCI, especificamente em UC, UMDR e ULDM. Para a concretização desta investigação, utilizou-se a técnica de Delphi, que envolveu duas rondas. Na primeira ronda foi possível contar com a participação de 37 terapeutas ocupacionais experientes na área, uma vez que exercem funções em UCCI, e na segunda ronda contou-se com a participação de 20 elementos. Obtiveram consenso na última ronda de Delphi um total de 96 categorias, constituindo esta listagem uma proposta de code set para UCCI. No que se refere às tipologias de unidades, 69 categorias obtiveram consenso em UC, 91 em UMDR e 41 em ULDM. Concluiu-se que a criação de code sets poderá constituir uma mais-valia em contexto de equipa multidisciplinar das UCCI, sendo uma forma de tornar a CIF operacional na prática clínica diária.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de natureza científica para obtenção do grau de Mestre em Engenharia Informática e de Computadores

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new procedure for determining eleven organochlorine pesticides in soils using microwave-assisted extraction (MAE) and headspace solid phase microextraction (HS-SPME) is described. The studied pesticides consisted of mirex, α- and γ-chlordane, p,p’-DDT, heptachlor, heptachlor epoxide isomer A, γ-hexachlorocyclohexane, dieldrin, endrin, aldrine and hexachlorobenzene. The HS-SPME was optimized for the most important parameters such as extraction time, sample volume and temperature. The present analytical procedure requires a reduced volume of organic solvents and avoids the need for extract clean-up steps. For optimized conditions the limits of detection for the method ranged from 0.02 to 3.6 ng/g, intermediate precision ranged from 14 to 36% (as CV%), and the recovery from 8 up to 51%. The proposed methodology can be used in the rapid screening of soil for the presence of the selected pesticides, and was applied to landfill soil samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The IEEE 802.15.4 is the most widespread used protocol for Wireless Sensor Networks (WSNs) and it is being used as a baseline for several higher layer protocols such as ZigBee, 6LoWPAN or WirelessHART. Its MAC (Medium Access Control) supports both contention-free (CFP, based on the reservation of guaranteed time-slots GTS) and contention based (CAP, ruled by CSMA/CA) access, when operating in beacon-enabled mode. Thus, it enables the differentiation between real-time and best-effort traffic. However, some WSN applications and higher layer protocols may strongly benefit from the possibility of supporting more traffic classes. This happens, for instance, for dense WSNs used in time-sensitive industrial applications. In this context, we propose to differentiate traffic classes within the CAP, enabling lower transmission delays and higher success probability to timecritical messages, such as for event detection, GTS reservation and network management. Building upon a previously proposed methodology (TRADIF), in this paper we outline its implementation and experimental validation over a real-time operating system. Importantly, TRADIF is fully backward compatible with the IEEE 802.15.4 standard, enabling to create different traffic classes just by tuning some MAC parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prototype validation is a major concern in modern electronic product design and development. Simulation, structural test, functional and timing debug are all forming parts of the validation process, although very often addressed as dissociated tasks. In this paper we describe an integrated approach to board-level prototype validation, based on a set of mandatory/optional BST instructions and a built-in controller for debug and test, that addresses the late mentioned tasks as inherent parts of a whole process

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artigo científico disponível actualmente em Early View (Online Version of Record published before inclusion in an issue)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho de Projeto para obtenção do grau de Mestre em Engenharia Civil