885 resultados para Chest


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Funding: This research was supported by Chest Heart and Stroke Scotland (R10/A128)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acknowledgements Funding: Chest, Heart and Stroke Scotland, grant ref. R13/A148. The funder had no role in study design, data collection, analysis and interpretation, writing of the manuscript, and in the decision to submit the manuscript for publication. All authors had full access to all the data in the study. The corresponding author had final responsibility for the decision to submit for publication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Funding: This research was supported by Chest Heart and Stroke Scotland (R10/A128)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The purpose of this work was to investigate the breast dose saving potential of a breast positioning technique (BP) for thoracic CT examinations with organ-based tube current modulation (OTCM).

Methods: The study included 13 female patient models (XCAT, age range: 27-65 y.o., weight range: 52 to 105.8 kg). Each model was modified to simulate three breast sizes in standard supine geometry. The modeled breasts were further deformed, emulating a BP that would constrain the breasts within 120° anterior tube current (mA) reduction zone. The tube current value of the CT examination was modeled using an attenuation-based program, which reduces the radiation dose to 20% in the anterior region with a corresponding increase to the posterior region. A validated Monte Carlo program was used to estimate organ doses with a typical clinical system (SOMATOM Definition Flash, Siemens Healthcare). The simulated organ doses and organ doses normalized by CTDIvol were compared between attenuation-based tube current modulation (ATCM), OTCM, and OTCM with BP (OTCMBP).

Results: On average, compared to ATCM, OTCM reduced the breast dose by 19.3±4.5%, whereas OTCMBP reduced breast dose by 36.6±6.9% (an additional 21.3±7.3%). The dose saving of OTCMBP was more significant for larger breasts (on average 32, 38, and 44% reduction for 0.5, 1.5, and 2.5 kg breasts, respectively). Compared to ATCM, OTCMBP also reduced thymus and heart dose by 12.1 ± 6.3% and 13.1 ± 5.4%, respectively.

Conclusions: In thoracic CT examinations, OTCM with a breast positioning technique can markedly reduce unnecessary exposure to the radiosensitive organs in the anterior chest wall, specifically breast tissue. The breast dose reduction is more notable for women with larger breasts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses results from a study of the use of cleaner cooking solutions and general health status of people in rural areas from the Battambang province of Cambodia. Data collection included 372 demographic, health and socio-economic surveys with households living in 6 villages in the Samlout district, general health examinations, and measurements of stove use and household concentrations of PM 2.5. The data reveal that health in this population is a major concern, with a very high prevalence of reported abdominal pain, nausea, chronic cough, chest pains, and fever during examinations.  At the household level, we find that clean stove ownership is significantly correlated with the educational status of household head and socio-economic status of a household. Respondents from households with clean stoves appear less likely (though not statistically significantly so) to report household individuals having health problems such as occasional cough, high blood pressure and tuberculosis. Concentrations of PM2.5 are positively correlated with prevalence of occasional cough, high blood pressure and tuberculosis. Based on these results, we advise field testing and evaluation of targeted health interventions in these villages to address the numerous concerns of the local population, including exploring the potential role of clean stoves.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coronary heart disease is the major cause of morbidity and mortality throughout the world, and is responsible for approximately one of every six deaths in the US. Angina pectoris is a clinical syndrome characterized by discomfort, typically in the chest, neck, chin, or left arm, induced by physical exertion, emotional stress, or cold, and relieved by rest or nitroglycerin. The main goals of treatment of stable angina pectoris are to improve quality of life by reducing the severity and/or frequency of symptoms, to increase functional capacity, and to improve prognosis. Ranolazine is a recently developed antianginal with unique methods of action. In this paper, we review the pharmacology of ranolazine, clinical trials supporting its approval for clinical use, and studies of its quality of life benefits. We conclude that ranolazine has been shown to be a reasonable and safe option for patients who have refractory ischemic symptoms despite the use of standard medications (for example, nitrates, beta-adrenergic receptor antagonists, and calcium channel antagonists) for treatment of anginal symptoms, and also provides a modestly improved quality of life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: It is unclear whether diagnostic protocols based on cardiac markers to identify low-risk chest pain patients suitable for early release from the emergency department can be applied to patients older than 65 years or with traditional cardiac risk factors. METHODS AND RESULTS: In a single-center retrospective study of 231 consecutive patients with high-risk factor burden in which a first cardiac troponin (cTn) level was measured in the emergency department and a second cTn sample was drawn 4 to 14 hours later, we compared the performance of a modified 2-Hour Accelerated Diagnostic Protocol to Assess Patients with Chest Pain Using Contemporary Troponins as the Only Biomarker (ADAPT) rule to a new risk classification scheme that identifies patients as low risk if they have no known coronary artery disease, a nonischemic electrocardiogram, and 2 cTn levels below the assay's limit of detection. Demographic and outcome data were abstracted through chart review. The median age of our population was 64 years, and 75% had Thrombosis In Myocardial Infarction risk score ≥2. Using our risk classification rule, 53 (23%) patients were low risk with a negative predictive value for 30-day cardiac events of 98%. Applying a modified ADAPT rule to our cohort, 18 (8%) patients were identified as low risk with a negative predictive value of 100%. In a sensitivity analysis, the negative predictive value of our risk algorithm did not change when we relied only on undetectable baseline cTn and eliminated the second cTn assessment. CONCLUSIONS: If confirmed in prospective studies, this less-restrictive risk classification strategy could be used to safely identify chest pain patients with more traditional cardiac risk factors for early emergency department release.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray computed tomography (CT) is a non-invasive medical imaging technique that generates cross-sectional images by acquiring attenuation-based projection measurements at multiple angles. Since its first introduction in the 1970s, substantial technical improvements have led to the expanding use of CT in clinical examinations. CT has become an indispensable imaging modality for the diagnosis of a wide array of diseases in both pediatric and adult populations [1, 2]. Currently, approximately 272 million CT examinations are performed annually worldwide, with nearly 85 million of these in the United States alone [3]. Although this trend has decelerated in recent years, CT usage is still expected to increase mainly due to advanced technologies such as multi-energy [4], photon counting [5], and cone-beam CT [6].

Despite the significant clinical benefits, concerns have been raised regarding the population-based radiation dose associated with CT examinations [7]. From 1980 to 2006, the effective dose from medical diagnostic procedures rose six-fold, with CT contributing to almost half of the total dose from medical exposure [8]. For each patient, the risk associated with a single CT examination is likely to be minimal. However, the relatively large population-based radiation level has led to enormous efforts among the community to manage and optimize the CT dose.

As promoted by the international campaigns Image Gently and Image Wisely, exposure to CT radiation should be appropriate and safe [9, 10]. It is thus a responsibility to optimize the amount of radiation dose for CT examinations. The key for dose optimization is to determine the minimum amount of radiation dose that achieves the targeted image quality [11]. Based on such principle, dose optimization would significantly benefit from effective metrics to characterize radiation dose and image quality for a CT exam. Moreover, if accurate predictions of the radiation dose and image quality were possible before the initiation of the exam, it would be feasible to personalize it by adjusting the scanning parameters to achieve a desired level of image quality. The purpose of this thesis is to design and validate models to quantify patient-specific radiation dose prospectively and task-based image quality. The dual aim of the study is to implement the theoretical models into clinical practice by developing an organ-based dose monitoring system and an image-based noise addition software for protocol optimization.

More specifically, Chapter 3 aims to develop an organ dose-prediction method for CT examinations of the body under constant tube current condition. The study effectively modeled the anatomical diversity and complexity using a large number of patient models with representative age, size, and gender distribution. The dependence of organ dose coefficients on patient size and scanner models was further evaluated. Distinct from prior work, these studies use the largest number of patient models to date with representative age, weight percentile, and body mass index (BMI) range.

With effective quantification of organ dose under constant tube current condition, Chapter 4 aims to extend the organ dose prediction system to tube current modulated (TCM) CT examinations. The prediction, applied to chest and abdominopelvic exams, was achieved by combining a convolution-based estimation technique that quantifies the radiation field, a TCM scheme that emulates modulation profiles from major CT vendors, and a library of computational phantoms with representative sizes, ages, and genders. The prospective quantification model is validated by comparing the predicted organ dose with the dose estimated based on Monte Carlo simulations with TCM function explicitly modeled.

Chapter 5 aims to implement the organ dose-estimation framework in clinical practice to develop an organ dose-monitoring program based on a commercial software (Dose Watch, GE Healthcare, Waukesha, WI). In the first phase of the study we focused on body CT examinations, and so the patient’s major body landmark information was extracted from the patient scout image in order to match clinical patients against a computational phantom in the library. The organ dose coefficients were estimated based on CT protocol and patient size as reported in Chapter 3. The exam CTDIvol, DLP, and TCM profiles were extracted and used to quantify the radiation field using the convolution technique proposed in Chapter 4.

With effective methods to predict and monitor organ dose, Chapters 6 aims to develop and validate improved measurement techniques for image quality assessment. Chapter 6 outlines the method that was developed to assess and predict quantum noise in clinical body CT images. Compared with previous phantom-based studies, this study accurately assessed the quantum noise in clinical images and further validated the correspondence between phantom-based measurements and the expected clinical image quality as a function of patient size and scanner attributes.

Chapter 7 aims to develop a practical strategy to generate hybrid CT images and assess the impact of dose reduction on diagnostic confidence for the diagnosis of acute pancreatitis. The general strategy is (1) to simulate synthetic CT images at multiple reduced-dose levels from clinical datasets using an image-based noise addition technique; (2) to develop quantitative and observer-based methods to validate the realism of simulated low-dose images; (3) to perform multi-reader observer studies on the low-dose image series to assess the impact of dose reduction on the diagnostic confidence for multiple diagnostic tasks; and (4) to determine the dose operating point for clinical CT examinations based on the minimum diagnostic performance to achieve protocol optimization.

Chapter 8 concludes the thesis with a summary of accomplished work and a discussion about future research.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis describes the development of an open-source system for virtual bronchoscopy used in combination with electromagnetic instrument tracking. The end application is virtual navigation of the lung for biopsy of early stage cancer nodules. The open-source platform 3D Slicer was used for creating freely available algorithms for virtual bronchscopy. Firstly, the development of an open-source semi-automatic algorithm for prediction of solitary pulmonary nodule malignancy is presented. This approach may help the physician decide whether to proceed with biopsy of the nodule. The user-selected nodule is segmented in order to extract radiological characteristics (i.e., size, location, edge smoothness, calcification presence, cavity wall thickness) which are combined with patient information to calculate likelihood of malignancy. The overall accuracy of the algorithm is shown to be high compared to independent experts' assessment of malignancy. The algorithm is also compared with two different predictors, and our approach is shown to provide the best overall prediction accuracy. The development of an airway segmentation algorithm which extracts the airway tree from surrounding structures on chest Computed Tomography (CT) images is then described. This represents the first fundamental step toward the creation of a virtual bronchoscopy system. Clinical and ex-vivo images are used to evaluate performance of the algorithm. Different CT scan parameters are investigated and parameters for successful airway segmentation are optimized. Slice thickness is the most affecting parameter, while variation of reconstruction kernel and radiation dose is shown to be less critical. Airway segmentation is used to create a 3D rendered model of the airway tree for virtual navigation. Finally, the first open-source virtual bronchoscopy system was combined with electromagnetic tracking of the bronchoscope for the development of a GPS-like system for navigating within the lungs. Tools for pre-procedural planning and for helping with navigation are provided. Registration between the lungs of the patient and the virtually reconstructed airway tree is achieved using a landmark-based approach. In an attempt to reduce difficulties with registration errors, we also implemented a landmark-free registration method based on a balanced airway survey. In-vitro and in-vivo testing showed good accuracy for this registration approach. The centreline of the 3D airway model is extracted and used to compensate for possible registration errors. Tools are provided to select a target for biopsy on the patient CT image, and pathways from the trachea towards the selected targets are automatically created. The pathways guide the physician during navigation, while distance to target information is updated in real-time and presented to the user. During navigation, video from the bronchoscope is streamed and presented to the physician next to the 3D rendered image. The electromagnetic tracking is implemented with 5 DOF sensing that does not provide roll rotation information. An intensity-based image registration approach is implemented to rotate the virtual image according to the bronchoscope's rotations. The virtual bronchoscopy system is shown to be easy to use and accurate in replicating the clinical setting, as demonstrated in the pre-clinical environment of a breathing lung method. Animal studies were performed to evaluate the overall system performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ostracodes were studied from deep Arctic Ocean cores obtained during the Arctic 91 expedition of the Polarstern to the Nansen, Amundsen and Makarov Basins, the Lomonosov Ridge, Morris Jesup Rise and Yermak Plateau, in order to investigate their distribution in Arctic Ocean deep water (AODW) and apply these data to paleoceanographic reconstruction of bottom water masses during the Quaternary. Analyses of coretop assemblages from Arctic 91 boxcores indicate the following: ostracodes are common at all depths between 1000 and 4500 m, and species distribution is strongly influenced by water mass characteristics and bathymetry; quantitative analyses comparing Eurasian and Canada Basin assemblages indicate that distinct assemblages inhabit regions east and west of the Lomonosov Ridge, a barrier especially important to species living in lower AODW; deep Eurasian Basin assemblages are more similar to those living in Greenland Sea deep water (GSDW) than those in Canada Basin deep water; two upper AODW assemblages were recognized throughout the Arctic Ocean, one living between 1000 and 1500 m, and the other, having high species diversity, at 1500-3000 m. Downcore quantitative analyses of species' abundances and the squared chord distance coefficient of similarity reveals a distinct series of abundance peaks in key indicator taxa interpreted to signify the following late Quaternary deep water history of the Eurasian Basin. During the Last Glacial Maximum (LGM), a GSDW/AODW assemblage, characteristic of cold, well oxygenated deep water > 3000 m today, inhabited the Lomonosov Ridge to depths as shallow as 1000 m, perhaps indicating the influence of GSDW at mid-depths in the central Arctic Ocean. During Termination 1, a period of high organic productivity associated with a strong inflowing warm North Atlantic layer occurred. During the mid-Holocene, several key faunal events indicate a period of warming and/or enhanced flow between the Canada and Eurasian Basins. A long-term record of ostracode assemblages from kastenlot core PS2200-5 (1073 m water depth) from the Morris Jesup Rise indicates a quasi-cyclic pattern of water mass changes during the last 300 kyr. Interglacial ostracode assemblages corresponding to oxygen isotope stages 1, 5, and 7 indicate rapid changes in dissolved oxygen and productivity during glacial-interglacial transitions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RATIONALE: As more preterm infants recover from severe bronchopulmonary dysplasia (BPD), it is critical to understand the clinical consequences of this condition on the lung health of adult survivors.

OBJECTIVES: To assess structural and functional lung parameters in young adult BPD survivors and preterm and term controls Methods: Young adult survivors of BPD (mean age 24) underwent spirometry, lung volumes, transfer factor, lung clearance index and fractional exhaled nitric oxide measurements together with high-resolution chest tomographic (CT) imaging and cardiopulmonary exercise testing.

MEASUREMENTS AND MAIN RESULTS: 25 adult BPD survivors, (mean ± SD gestational age 26.8 ± 2.3 weeks; birth weight 866 ± 255 g), 24 adult prematurely born non-BPD controls (gestational age 30.6 ± 1.9 weeks; birth weight 1234 ± 207 g) and 25 adult term birth control subjects (gestational age 38.5 ± 0.9 weeks; and birth weight 3569 ± 2979 g) were studied. BPD subjects were more likely to be wakened by cough (OR 9.7, 95% CI: 1.8 to 52.6), p<0.01), wheeze and breathlessness (OR 12.2, 95%CI: 1.3 to 112), p<0.05) than term controls after adjusting for sex and current smoking. Preterm subjects had greater airways obstruction than term subjects. BPD subjects had significantly lower values for FEV1 and FEF25-75 (% predicted and z scores) than term controls (both p<0.001). Although non-BPD subjects also had lower spirometric values than term controls, none of the differences reached statistical significance. More BPD subjects (25%) had fixed airflow obstruction than non-BPD (12.5%) and term (0%) subjects (p=0.004). Both BPD and non-BPD subjects had significantly greater impairment in gas transfer (KCO % predicted) than term subjects (both p<0.05). Eighteen (37%) preterm participants were classified as small for gestational age (birth weight < 10th percentile for gestational age). These subjects had significantly greater impairment in FEV1 (% predicted and z scores) than those born appropriate for gestational age. BPD survivors had significantly more severe radiographic structural lung impairment than non-BPD subjects. Both preterm groups had impaired exercise capacity compared to term controls. There was a trend for greater limitation and leg discomfort in BPD survivors.

CONCLUSIONS: Adult preterm birth survivors, especially those who developed BPD, continue to experience respiratory symptoms and exhibit clinically important levels of pulmonary impairment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Lung clearance index (LCI) has good clinimetric properties and an acceptable feasibility profile as a surrogate endpoint in Cystic Fibrosis (CF). Although most studies to date have been in children, increasing numbers of adults with CF also have normal spirometry. Further study of LCI as an endpoint in CF adults is required. Therefore, the purpose of this study was to determine the clinimetric properties of LCI over the complete age range of people with CF. Methods: Clinically stable adults and children with CF and age matched healthy controls were recruited. Results: LCI and spirometry data for 110 CF subjects and 61 controls were collected at a stable visit. CF Questionnaire-Revised (CFQ-R) was completed by 80/110 CF subjects. Fifty-six CF subjects completed a second stable visit. The LCI CV% was 4.1% in adults and 6.3% in children with CF. The coefficient of repeatability of LCI was 1.2 in adults and 1.3 in children. In both adults and children, LCI (AUCROC=0.93 and 0.84) had greater combined sensitivity and specificity to discriminate between people with CF and controls compared to FEV1 (AUCROC=0.88 and 0.60) and FEF25-75 (AUCROC=0.87 and 0.68). LCI correlated significantly with the CFQ-R treatment burden in adults (r=-0.37; p<0.01) and children (r=-0.50; p<0.01). Washout tests were successful in 90% of CF subjects and were perceived as comfortable and easy to perform in both adults and children. Conclusions: These data support the use of LCI as a surrogate outcome measure in CF clinical trials in adults as well as children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sarcoma metastatic to the brain is uncommon and rarely occurs as the initial manifestation of tumor. Alveolar soft part sarcoma (ASPS) is a rare but well-studied subtype of sarcoma. A 39-year-old man presented with seizures due to a left temporal meningeal-enhancing lesion with striking brain edema on MRI. The patient underwent neurosurgical resection for suspected meningioma. Histology showed large tumor cells clustering and forming small nests, in places with pseudoalveolar pattern. Diastase-resistant periodic acid-Schiff revealed very rare granular and rod-like cytoplasmic inclusions. Immunohistochemistry showed convincing positivity only with vimentin and smooth muscle actin. The histological features were strongly suggestive of ASPS. At the molecular level RT-PCR and sequencing analysis demonstrated ASPCR1-TFE3 fusion confirming the histological diagnosis of ASPS. There was no evidence of primary extracranial tumor by physical examination and on chest and abdominal CT scan 11 months after presentation. ASPS typically arise from the soft tissues of the extremities and develop multiple metastatic deposits usually with a long clinical course. This case may represent primary meningeal ASPS although metastatic deposit from an undiscovered primary site cannot be entirely excluded.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Foundation doctors are expected to assess and interpret plain x-ray studies of the chest/abdomen before a definitive report is issued by senior staff. The Royal College of Radiologists have published guidelines (RCR curriculum) on the scope of plain film findings medical students should be familiar with.1 Studies have shown that the x-ray interpretation without feedback does not significantly improve diagnostic ability. 2 Queen’s University, Belfast Trust Radiology and Experior Medical developed an online system to assess individual student ability to interpret X-ray findings. Over a series of assessments each student’s profile is built up, identifying strengths and weakness. The system can then create bespoke individual assessments re-evaluating previously identified weak areas and quantifying interpretative skill improvement. Aim: To determine how readily an online system is adopted by senior medical students, investigating if increasing exposure to x-ray interpretation combined with cyclical formative feedback enhances performance. Methods: The system was offered to all 270 final year medical students as an online resource. The system comprised a series of 20 weekly 30 minute assessments, containing normal and abnormal x-rays within the RCR curriculum. After each assessment students were given formative feedback, including their own result, annotated answers, peer group comparison and a breakdown of areas of strength and weakness. Focus groups of 4-5 students addressed student perspectives of the system, including ease of use, image resolution, system performance across different operating platforms, perceived value of formative feedback loops, breakdown of performance and the value of bespoke personalised assessments. Research Ethics Approval was granted for the study. Data analysis was via two-sided one-sample t-test; initial minimal recruitment was estimated as 60 students, to detect a mean 10% change in performance, with a standard deviation of 20%. Results and Discussion: Over 80% (n = XXX/270) of the student cohort engaged with the study. Student baseline average was 39%, increasing to 62% by the exit test. The steadily sustained improvement (57% relative performance in interpretative diagnostic accuracy) was despite increasing test difficulty. Student feedback via focus groups was universally positive throughout the examined domains. Conclusion: The online resource proved to be valuable, with high levels of student engagement, improving performance despite increasingly difficulty testing and positive learner experience with the system. References: 1. Undergraduate Radiology Curriculum, The Royal College of Ra, April 2012. Ref No. BFCR(12)4 The Royal College of Radiologists, April 2012 2. I Satia, S Bashagha, A Bibi, R Ahmed, S Mellor, F Zaman. Assessing the accuracy and certainty in interpretating chest x-rays in the medical division. Clin Med August 2013 Vol.13 no. 4 349-352

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to collect information on the incidence, pathophysiology, treatment and mortality of pneumothorax in the Emergency Room. Pneumothorax is classified as spontaneous (primary, secondary or catamenial) or traumatic (iatrogenic or secondary to a blunt or penetrating chest injury). Between January 2007 and December 2009, 102 patients with pneumothorax were seen in our Emergency Room. Their records were examined and their data collected retrospectively. The type and side of the pneumothorax and age, sex, incidence and mortality were analyzed. The cases, involving 93 males and 9 females, broke down as follows: 68 spontaneous (66.7%), 33 traumatic (32.3%) and one iatrogenic (0.98%). The mean age was 47.3 (range 12-99); the incidence was 0.10%. There were no deaths due to pneumothorax in the Emergency Room. Traumatic pneumothorax was associated with blunt chest trauma, pleural effusion, hemothorax, cranial trauma, fractured collarbone, upper and lower limb fracture, pelvic fracture, vertebral and spinal trauma, sternum fracture and abdominal trauma. Pneumothorax is a common clinical problem. A multidisciplinary approach is essential to reduce the risk of morbidity and mortality. The incidence of pneumothorax in the Emergency Room was similar to that reported in the literature, while mortality data cannot be compared due to the lack of published studies.