920 resultados para Amplifier


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a high senstivity low cost capacitive strain gage sensor. The theory, design, and sensor construction details are presented. It consists of eight capacitive sensors connected in two full bridges. The capacitive strain gage sensor structure was designed in order to produce high sensitivity and low dependence with temperature. By using a simple signal conditioning circuit constituted by a differential amplifier, a band-pass filter, and a precision rectifier the device can measure forces with resolution of 0.009 N and precision of 98.7%. It is rugged, presents linear response, and good repeatability. It presents sensitivity of 8.7 V/N and fall time of 12 ms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was evaluated movements of lower limb in the double pulley system equipment on ten male volunteers during contraction of gastrocnemius (caput laterale ) and gluteus maximus muscles in the following movements: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. Myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. We observed weak gastrocnemius muscle activity for all movements studied. In the case of gluteus maximus, the most important potentials were observed for movement 2, while for the remaining movements the actions were of reasonable intensity. Compared to gluteus, gastrocnemius was less required for all movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analog circuit that implements a radial basis function network is presented. The proposed circuit allows the adjustment of all shape parameters of the radial functions, i.e., amplitude, center and width. The implemented network was applied to the linearization of a nonlinear circuit, a voltage controlled oscillator (VCO). This application can be classified as an open-loop control in which the network plays the role of the controller. Experimental results have proved the linearization capability of the proposed circuit. Its performance can be improved by using a network with more basis functions. Copyright 2007 ACM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we use a stabilized holographic technique to study both refractive index and absorption gratings recorded in thin films made of Disperse Red 1 (DR1) embedded in an organic polymer matrix (PMMA) deposited on glass substrate. Gratings are recorded by linearly polarized illumination with the interference pattern of two crossing beams. One of the beams is phase modulated and the interference signals between the transmitted and diffracted waves are detected by a tuned lock-in amplifier. The technique allows measuring separately changes of the refractive index and the absorption coefficient during the course of the photoreaction process. The time evolution of the diffraction efficiencies during recording has shown bi-exponential kinetics for both gratings. © 2008 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cleft palates cause alterations in palate and lip structures, and it may also cause hearing loss because of recurrent otitis media. The appropriate treatment is controversial. It may include the prescription of antibiotics and insertion of a ventilation tube, or even otorhinolaryngological and audiological assistance, and hearing rehabilitation, with the use of an individual sound amplifier aid (ISAA). Aim: To characterize the profile of individuals with cleft palate and hearing loss, users of ISAA are assisted by the center of otorhinolaryngology and speech therapy of a hospital specialized in craniofacial anomalies and hearing impairment. Retrospective Study. Material and Methods: Retrospective analysis of 131 charts of patients with corrected cleft palate and hearing loss, fitted with ISAA by the center abovementioned. Results: The sample (n=131) was characterized by a prevalence of females (53%), unilateral incisive transforaminal cleft (27%), presence of associated anomalies (51%), history of alterations of the middle ear (56%) and surgery intervention (56%). Conclusion: The general profile of the individuals with cleft palate and hearing loss, fitted with ISAA, was characterized by the predominance of cleft lip and palate, positive history of middle ear alterations, surgery intervention and bilateral sensorineural hearing loss. © Revista Brasileira de Otorrinolaringologia. All Rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dance activities were administered to a group of deaf adolescents via visual and auditory stimuli in order to improve their perceptions of monotonic rhythmic structures. Status of psychomotor development was also assessed before and after participation in the program. Twenty deaf adolescents (ages between 12 and 13 years) were divided into two groups, experimental (EG) and control (CG). Before and after participating in the program for 26 weeks, participants were evaluated in rhythmical tasks adapted from the classical test of M. Stambak. The tasks included the perception of drum beats, actually viewed hit movements, or heard via a sound amplifier. Psychomotor tests were administered only to the EG. The period of practice with dance activities changed the individuals' performance in the monotonic rhythmic test. Also, the success rate improved in both, visual and auditory input tasks. Individuals in the CG showed no changes in performance. For the EG, in the post-test, the status of psychomotor development was six months below the target age of the tests (i.e., 11 years). Findings suggested that dance activities can change deaf individuals' auditory perception of rhythmic structures. Participation in such a program can also positively affect psychomotor development. © FTCD/FIP-MOC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Apresenta os resultados de uma pesquisa de campo desenvolvida em duas escolas públicas estaduais de ensino fundamental, localizadas no conjunto Paar, área periférica do município de Ananindeua-Pa, região metropolitana de Belém, no qual reflito sobre o espaço que a escola pública tem reservado à participação da criança a partir da investigação das interações visíveis no ambiente escolar, tendo em vista a idéia de que o espaço escolar não se reduz a indivíduos, mas se constrói por relações sociais. Para tanto, detive-me à análise das representações dos sujeitos envolvidos com a escola sobre a criança e a infância. Esta pesquisa sinaliza, antes de tudo, caminhos que possam desenvolver novas lentes ampliadoras do nosso ângulo de visão, na perspectiva de um aprender a pensar relacionalmente sobre as relações entre adultos e crianças estabelecidas no campo do poder das instituições escolares.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação de mestrado apresenta dois projetos, sendo um referente ao sistema Tramo Oeste, e o outro ao sistema Pará – Maranhão; relacionado ao trecho Marabá – Santa Maria, com bombeamento remoto e amplificação Raman. A dissertação trata da expansão da capacidade de transmissão do sistema óptico da Eletronorte, no Tramo Oeste. Atualmente, esse sistema opera à taxa STM1 (155 Mb/s). Também é usada uma nova tecnologia para eliminação de estações repetidoras, através do bombeamento remoto. Essa técnica se fundamenta no uso de amplificadores ópticos bombeados remotamente, por meio das fibras ópticas do cabo OPGW (Optical Ground Wire) já instaladas no sistema.Esses amplificadores ópticos são constituídos somente por componentes passivos; e, além disso, podem ser acomodados em caixas de emendas ópticas; as quais são fixadas nas torres das linhas de transmissão do sistema, ao longo do enlace; sendo que as fontes ópticas para a realização do bombeamento remoto são localizadas e alimentadas nas próprias subestações terminais. A simulação dos sistemas é através de um software comercial de simulação Optisystem 4.1™. Esta dissertação propõe mudanças nos sistemas ópticos para aumentar a capacidade de transmissão por WDM; bombeamento remoto para estações sem repetição, e uso de amplificação Raman. Aborda-se ainda, a concepção de um backbone óptico DWDM, que é um convênio de cooperação técnica entre a Eletronorte e o Governo do Estado do Pará; e os resultados das simulações desse backbone óptico. É feita uma análise crítica comparativa deste, com os projetos dos sistemas ópticos do Tramo Oeste e do sistema Pará – Maranhão; referente ao trecho Marabá – Santa Maria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vários órgãos do corpo humano manifestam suas funções por meio de atividades elétricas. A medição desses e de outros biopotenciais pode fornecer indícios importantes que permitem o estudo do funcionamento real dos órgãos. Tais medições não constituem tarefa simples porque envolvem aquisição de dados de sinais cujas amplitudes podem ser na faixa entre 1 μV e 10 mV e também porque, no ambiente em que são feitos esses registros, estão presentes diversos tipos de sinais interferentes que causam degradação da relação sinal/ruído. Logo, o projeto do condicionador de biopotencial deve ser cercado de cuidados para que o circuito final reúna as melhores características de desempenho. Neste trabalho apresenta-se um estudo da origem dos biopotenciais, suas características, os circuitos utilizados para ganho e filtragem do sinal, além das interferências presentes nos sistemas de medições e alguns circuitos para redução desses sinais. É desenvolvido então, um condicionador para registro de biopotenciais corticais com blocos de filtragem e ganho do sinal em até 40 000. Os testes com o condicionador foram realizados registrando o potencial cortical provocado visual e o eletroencefalograma, e nos resultados experimentais é possível observar um desempenho satisfatório do equipamento.