929 resultados para Amplifier


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mechanism involved in the Tm(3+)((3)F(4)) -> Tb(3+)((7)F(0,1,2)) energy transfer as a function of the Tb concentration was investigated in Tm:Tb-doped germanate (GLKZ) glass. The experimental transfer rate was determined from the best fit of the (3)F(4) luminescence decay due to the Tm -> Tb energy transfer using the Burshtein model. The result showed that the 1700 nm emission from (3)F(4) can be completely quenched by 0.8 mol% of Tb(3+). As a consequence, the (7)F(3) state of Tb(3+) interacts with the (3)H(4) upper excited state of TM(3+) slighting decreasing its population. The effective amplification coefficient beta(cm(-1)) that depends on the population density difference Delta n = n((3)H(4))-n((3)F(4)) involved in the optical transition of Tm(3+) (S-band) was calculated by solving the rate equations of the system for continuous pumping with laser at 792 nm, using the Runge-Kutta numerical method including terms of fourth order. The population density inversion An as a function of Tb(3+) concentration was calculated by computational simulation for three pumping intensities, 0.2, 2.2 and 4.4 kWcm(-2). These calculations were performed using the experimental Tm -> Tb transfer rates and the optical constants of the Tm (0.1 mol%) system. It was demonstrated that 0.2 mol% of Tb(3+) propitiates best population density inversion of Tin(3+) maximizing the amplification coefficient of Tm-doped (0.1 mol%) GLKZ glass when operating as laser intensity amplification at 1.47 mu m. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes two simple thermal methods for measuring the energy fluence in J/cm 2 from a diagnostic x-ray exposure. Both detectors absorb essentially 100% of the radiation and give a signal that is directly proportional to the energy fluence of the x-ray beam. One detector measures the thermal effect when a pulse of x rays is totally absorbed in the pyroelectric detector of lead-zirconium-titanate (PZT). The other detector measures the expansion of a gas surrounding a lead disk detector in a photoacoustic chamber. The increased pressure of the gas is transmitted through a 1-mm duct to a sensitive microphone. Both detectors have previously been used to measure the energy fluence rate of continuous x-ray beams in the same energy region using a chopped beam and a lock-in amplifier. Measurement of the energy fluence of a pulse of radiation eliminates the need for the beam chopper and lock-in amplifier and results in a simple, rugged, and inexpensive dosimeter. Either method can be combined with the area of the beam to give an estimate of the imparted energy to the patient from a diagnostic x-ray exposure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rectus femoris was analysed in 10 volunteers during knee flexion and extension with the feet in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an A/D conversion plaque (Model CAD 10/26), software specially designed to record and analyse the signals, Horizontal Leg Press, and electrogoniometers were used. The rectus femoris muscle showed strong potentials at the beginning of knee extension. In the simultaneous bendings of the knee and hip the activity was strong toward the end of the movement. The rectus femoris showed a similar activity both in the upper and lower platforms. As for foot positions, the rectus femoris showed the smallest potentials with the foot in plantar flexion and the largest ones with the foot in dorsal flexion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gastrocnemius was analysed in 10 male volunteers during knee flexion and extension with the foot in normal, plantar flexion and dorsal flexion positions. Hewlett-Packard surface electrodes, an electromyographic signal amplifier, a computer equipped with an AID conversion plaque (Model CAD 10/26), a software specially designed to record and analyse the signals, a horizontal leg press, and electrogoniometers were used. The gastrocnemius muscle showed strong potentials at the end of knee extension and beginning of knee flexion. The muscle presented a similar activity both in the zipper and lower platforms. As to bilateral action, the right gastrocnemius presented stronger potentials on the upper platforms, whereas the potentials were bilaterally similar on the lower platforms. As for foot position, the gastrocnemius presented strong potentials when the foot was in plantar flexion. The remaining positions had no effect on the work of the muscle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The design of a Gilbert Cell Mixer and a low noise amplifier (LNA), using GaAs PHEMT technology is presented. The compatibility is shown for co-integration of both block on the same chip, to form a high performance 1.9 GHz receiver front-end. The designed LNA shows 9.23 dB gain and 2.01 dB noise figure (NF). The mixer is designed to operate at RF=1.9 GHz, LO=2.0 GHz and IF=100 MHz with a gain of 14.3 dB and single sideband noise figure (SSB NF) of 9.6 dB. The mixer presents a bandwith of 8 GHz.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A CMOS memory-cell for dynamic storage of analog data and suitable for LVLP applications is proposed. Information is memorized as the gate-voltage of input-transistor of a gain-boosting triode-transconductor. The enhanced output-resistance improves accuracy on reading out the sampled currents. Additionally, a four-quadrant multiplication between the input to regulation-amplifier of the transconductor and the stored voltage is provided. Designing complies with a low-voltage 1.2μm N-well CMOS fabrication process. For a 1.3V-supply, CCELL=3.6pF and sampling interval is 0.25μA≤ ISAMPLE ≤ 0.75μA. The specified retention time is 1.28ms and corresponds to a charge-variation of 1% due to junction leakage @75°C. A range of MR simulations confirm circuit performance. Absolute read-out error is below O.40% while the four-quadrant multiplier nonlinearity, at full-scale is 8.2%. Maximum stand-by consumption is 3.6μW/cell.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The double pulley equipment was tested on ten male volunteers during contraction of the semitendinosus and biceps femoris (caput longum) muscles in the following movements of the lower limbs: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. The myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. The semitendinosus and biceps femoris muscles presented the highest potentials in movements 1; 2; 7, 8 and 9, whereas the potentials in the remaining movements were negligible. The pattern of activity of the semitendinosus and the biceps femoris was similar in exercises 1, 2, 3, 4 and 8. The potentials of the semitendinosus prevailed in movements 5, 6 and 7, and the strongest potentials observed in movement 9 were those of the biceps femoris.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An active leakage-injection scheme (ALIS) for low-voltage (LV) high-density (HD) SRAMs is presented. By means of a feedback loop comprising a servo-amplifier and a common-drain MOSFET, a current matching the respective bit-line leakage is injected onto the line during precharge and sensing, preventing the respective capacitances from erroneous discharges. The technique is able to handle leakages up to hundreds of μA at high operating temperatures. Since no additional timing is required, read-out operations are performed at no speed penalty. A simplified 256×1bit array was designed in accordance with a 0.35 CMOS process and 1.2V-supply. A range of PSPICE simulation attests the efficacy of ALIS. With an extra power consumption of 242 μW, a 200 μA-leakage @125°C, corresponding to 13.6 times the cell current, is compensated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A low-voltage low-power 2nd-order CMOS pseudo-differential bump-equalizer is presented. Its topology comprises a bandpass section with adjustable center frequency and quality factor, together with a programmable current amplifier. The basic building blocks are triode-operating transconductors, tunable by means of either a DC voltage or a digitally controlled current divider. The bump-equalizer as part of a battery-operated hearing aid device is designed for a 1.4V-supply and a 0.35μm CMOS fabrication process. The circuit performance is supported by a set of simulation results, which indicates a center frequency from 600Hz to 2.4kHz, 1≤Q≤5, and an adjustable gain within ±6dB at center frequency. The filter dynamic range lies around 40dB. Quiescent consumption is kept below 12μW for any configuration of the filter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a high senstivity low cost capacitive strain gage sensor. The theory, design, and sensor construction details are presented. It consists of eight capacitive sensors connected in two full bridges. The capacitive strain gage sensor structure was designed in order to produce high sensitivity and low dependence with temperature. By using a simple signal conditioning circuit constituted by a differential amplifier, a band-pass filter, and a precision rectifier the device can measure forces with resolution of 0.009 N and precision of 98.7%. It is rugged, presents linear response, and good repeatability. It presents sensitivity of 8.7 V/N and fall time of 12 ms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was evaluated movements of lower limb in the double pulley system equipment on ten male volunteers during contraction of gastrocnemius (caput laterale ) and gluteus maximus muscles in the following movements: 1) hip extension with extended knee and erect trunk, 2) hip extension with flexed knee and erect trunk, 3) hip extension with flexed knee and erect trunk, 3) hip extension with extended knee and inclined trunk, 5) hip abduction along the midline, 7) hip abduction with extension beyond the midline, 8) adduction with hip flexion beyond the midline, 8) adduction with hip flexion beyond the midline, and 9) adduction with hip extension beyond the midline. Myoelectric signals were taken up by Lec Tec surface electrodes connected to a 6-channel Lynx electromyographic signal amplifier coupled with a computer equipped with a model CAD 10/26 analogue digital conversion board and with a specific software for signal recording and analysis. We observed weak gastrocnemius muscle activity for all movements studied. In the case of gluteus maximus, the most important potentials were observed for movement 2, while for the remaining movements the actions were of reasonable intensity. Compared to gluteus, gastrocnemius was less required for all movements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analog circuit that implements a radial basis function network is presented. The proposed circuit allows the adjustment of all shape parameters of the radial functions, i.e., amplitude, center and width. The implemented network was applied to the linearization of a nonlinear circuit, a voltage controlled oscillator (VCO). This application can be classified as an open-loop control in which the network plays the role of the controller. Experimental results have proved the linearization capability of the proposed circuit. Its performance can be improved by using a network with more basis functions. Copyright 2007 ACM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we use a stabilized holographic technique to study both refractive index and absorption gratings recorded in thin films made of Disperse Red 1 (DR1) embedded in an organic polymer matrix (PMMA) deposited on glass substrate. Gratings are recorded by linearly polarized illumination with the interference pattern of two crossing beams. One of the beams is phase modulated and the interference signals between the transmitted and diffracted waves are detected by a tuned lock-in amplifier. The technique allows measuring separately changes of the refractive index and the absorption coefficient during the course of the photoreaction process. The time evolution of the diffraction efficiencies during recording has shown bi-exponential kinetics for both gratings. © 2008 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cleft palates cause alterations in palate and lip structures, and it may also cause hearing loss because of recurrent otitis media. The appropriate treatment is controversial. It may include the prescription of antibiotics and insertion of a ventilation tube, or even otorhinolaryngological and audiological assistance, and hearing rehabilitation, with the use of an individual sound amplifier aid (ISAA). Aim: To characterize the profile of individuals with cleft palate and hearing loss, users of ISAA are assisted by the center of otorhinolaryngology and speech therapy of a hospital specialized in craniofacial anomalies and hearing impairment. Retrospective Study. Material and Methods: Retrospective analysis of 131 charts of patients with corrected cleft palate and hearing loss, fitted with ISAA by the center abovementioned. Results: The sample (n=131) was characterized by a prevalence of females (53%), unilateral incisive transforaminal cleft (27%), presence of associated anomalies (51%), history of alterations of the middle ear (56%) and surgery intervention (56%). Conclusion: The general profile of the individuals with cleft palate and hearing loss, fitted with ISAA, was characterized by the predominance of cleft lip and palate, positive history of middle ear alterations, surgery intervention and bilateral sensorineural hearing loss. © Revista Brasileira de Otorrinolaringologia. All Rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dance activities were administered to a group of deaf adolescents via visual and auditory stimuli in order to improve their perceptions of monotonic rhythmic structures. Status of psychomotor development was also assessed before and after participation in the program. Twenty deaf adolescents (ages between 12 and 13 years) were divided into two groups, experimental (EG) and control (CG). Before and after participating in the program for 26 weeks, participants were evaluated in rhythmical tasks adapted from the classical test of M. Stambak. The tasks included the perception of drum beats, actually viewed hit movements, or heard via a sound amplifier. Psychomotor tests were administered only to the EG. The period of practice with dance activities changed the individuals' performance in the monotonic rhythmic test. Also, the success rate improved in both, visual and auditory input tasks. Individuals in the CG showed no changes in performance. For the EG, in the post-test, the status of psychomotor development was six months below the target age of the tests (i.e., 11 years). Findings suggested that dance activities can change deaf individuals' auditory perception of rhythmic structures. Participation in such a program can also positively affect psychomotor development. © FTCD/FIP-MOC.