986 resultados para Air Particulate Matter


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Very few studies regarding fungal and particulate matter (PM) exposure in feed industry have been reported, although such contaminants are likely to be a significant contributing factor to several symptoms reported among workers. The purpose of this study has been to characterize fungal and dust exposure in one Portuguese feed industry. Material and Methods: Air and surface samples were collected and subject to further macro- and microscopic observations. In addition we collected other air samples in order to perform real-time quantitative polymerase chain reaction (PCR) amplification of genes from Aspergillus fumigatus and Aspergillus flavus complexes as well as Stachybotrys chartarum. Additionally, two exposure metrics were considered – particle mass concentration (PMC), measured in 5 different sizes (PM0.5, PM1, PM2.5, PM5, PM10), and particle number concentration (PNC) based on results given in 6 different sizes in terms of diameter (0.3 μm, 0.5 μm, 1 μm, 2.5 μm, 5 μm and 10 μm). Results: Species from the Aspergillus fumigatus complex were the most abundant in air (46.6%) and in surfaces, Penicillium genus was the most frequently found (32%). The only DNA was detected from A. fumigatus complex. The most prevalent in dust samples were smaller particles which may reach deep into the respiratory system and trigger not only local effects but also the systemic ones. Conclusions: Future research work must be developed aiming at assessing the real health effects of these co-exposures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Sampling the total air concentration of particulate matter (PM) only provides a basic estimate of exposure that normally not allows correlating with the observed health effects. Therefore is of great importance to recognize the particles size distribution and, particularly, the exposure to fine particles (≤ 2.5 μm). This particles dimension corresponds to the respirable fraction, the one that can implicate local and systemic effects due to particle deposition and clearance from the lungs and transport within the organism. This study intended to describe occupational exposure to PM2.5 in three units related with swine production and consumption, namely: feed production, swine production and swine slaughterhouse. A size-selective particle measuring in five to six workplaces of each unit was performed. Measurements of PM were done using a portable direct-reading hand-held equipment (Lighthouse, model 3016 IAQ). Data showed slaughterhouse unit with higher values, with values ranging from 0.030 to 0.142 mg/m3 (0.073 + 0.043), being the cutting room the workplace with higher values. In feed production unit, values were between 0.026 and 0.033 mg/m3 (0.028 + 0.003) with the warehouse of pharmacy products as the workplace with higher values. Finally, in swine unit values ranged from 0.006 to 0.048 mg/m3 (0.023 + 0.017) with the batteries area presenting the higher values. PM can be rich in fungi and bacteria and their metabolites, such as endotoxins and mycotoxins. Previous publications already showed high contamination in these occupational settings and particles can have an important role in exposure since can easily act as carrier of these agents. Data acquired allow not only a better prediction of particle penetration into respiratory regions of the respiratory tract, but also a better estimation of PM health effects. Moreover, data permit to identify the workplaces where investment should be made to prevent and reduce exposure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A qualidade do ar interior (QAI) em edifícios é uma preocupação que acompanha o Homem desde há séculos. A qualidade do ar interior nas escolas, em particular, tem vindo a provocar um crescente interesse, dado que o grupo populacional pertence a um grupo etário mais suscetível de ser afetado. A utilização de ferramentas numéricas de modelação na avaliação da QAI é uma mais valia, pois permite estimar as concentrações dos poluentes no interior dos edifícios. O principal objetivo deste estudo consiste na avaliação da qualidade do ar interior através da aplicação de uma ferramenta a um caso de estudo. Neste caso de estudo estimou-se a concentração de material particulado (PM10) numa sala de aula da Escola Básica nº 1 da Glória, em Aveiro. Neste âmbito, foi aplicado o modelo INDEX, Indoor Exposure model, que possibilita o cálculo de concentrações interiores de poluentes atmosféricos. Os resultados da aplicação indicam que as concentrações do ar interior são influenciadas pelas concentrações exteriores e pela velocidade do vento. Note-se, contudo, que os valores simulados cumprem os valores legislados na Portaria nº 353-A/2013, de 4 de Dezembro. Embora os resultados simulados não revelem uma má qualidade do ar interior na sala de aula da Escola Básica nº 1 da Glória, a avaliação de outros poluentes seria um ponto de extrema importância, de forma a verificar se os requisitos da qualidade do ar interior estarão a ser garantidos.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study aimed to determine the concentration and inorganic chemical composition of samples from airborne particulate matter inhaled in fine and coarse fractions. Aerosol samples were collected in 2013 and 2014, from sites located in the cities of Londrina and Maringa, in the state of Paraná, Brazil. The samples were collected daily (24h) in two campaigns: winter and summer. For the collection, was used a dichotomous sampler with quartz fiber filter with 47 mm in size and 2 µm porosity, 97% efficiency, retaining particles of up to 0.3 µm. Quantification of the airborne particulate matter mass was performed by gravimetry method. The results from Londrina to PM2.5 and MP2,5-10 represent, respectively, 29.2% and 70.8% of airborne particulate matter in the winter campaign (2013), 30.9% (PM2.5) and 69.1 % (MP2,5-10) in the summer campaign (2013), and 35.9% (PM2.5) and 64.1% (MP2,5-10) in the winter 2014 campaign. In the city of Maringa, the results presented the percentage of 42.0% (PM2.5) and 58.0% (MP2,5-10) for the winter season (2014), and 28.8% (PM2.5) and 71.2 % (MP2,5-10) for the summer season (2014). The PM2.5/PM10 ratio was on average 0.3, demonstrating that both cities are developing urban areas. Analysis of the major soluble inorganic species in water (NO3-, SO42- and Cl-) associated with MP2,5-10 were quantified by ion chromatography at the LACA Laboratory in the State University of Londrina, with the largest contribution found in all campaigns was to NO3-. The NO3-/SO42- ratios above 1.0 indicate the local traffic contribution. The analysis of metals associated with PM2.5 was carried out by mass spectrometry with inductively coupled plasma (ICP-MS) in the Federal University of Santa Catarina. The Zn, Pb, Cu and Mn concentrations found in all campaigns indicate the contribution of mobile sources to PM2.5. The concentration of BCe in PM2.5 was determined by reflectance, with higher BCe concentrations being found in winter campaigns. In general, Londrina presented the highest concentrations from the species analyzed when compared to Maringá. In addition, the analysis of the air mass trajectories indicated the transportation of pollutants coming mainly from fires in the southeastern region of the country.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Sampling the total air concentration of particulate matter (PM) only provides a basic estimate of exposure that normally not allows correlating with the observed health effects. Therefore is of extreme importance to know the particles size distribution and, in more detail, the exposure to fine particles (≤ 2.5 µm). This particles dimension corresponds to the respirable fraction. This particle fraction can result, besides local effects, in systemic effects due to particle deposition and clearance from the lungs and transport within the organism. This study intended to describe occupational exposure to PM2.5 in three different units located near Lisbon and related with occupational exposure to organic dust, namely: swine and poultry feed production and waste management.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Study developed in order to know the carpet influence when used in the floor of a hotel room. Twelve air samples of 250L (six in a room with carpet and six more in a room with wood floor) were collected through an impaction method with a flow rate of 140 L/min onto malt extract agar (MEA) supplemented with chloramphenicol (0.05%), using the Millipore air Tester (Millipore), during cleaning activities. Outdoor sample was also performed to be used as a reference. Surface samples from floor and desks, taken at the same time, were collected by the swabbing method. to 7 days. Besides fungal contamination, we also assessed particulate matter contamination in both rooms during the same cleaning tasks. In the analyzed sur- faces, isolates belonging to Aspergillus fumigatus complex were the only fungi found in the carpeted room, whereas in the other room we found Penicllium sp. (63.6%) and Aspergillus sp. (13.6%) as the most frequent genera. In the case of particles the room with carpet obtained significant higher values for both metrics (PMC and PNC), showing that carpet may has influence on particles’ contamination of the room.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Children spend a large part of their time at schools, which might be reflected as chronic exposure. Ultrafine particles (UFP) are generally associated with a more severe toxicity compared to fine and coarse particles, due to their ability to penetrate cell membranes. In addition, children tend to be more susceptible to UFP-mediated toxicity compared to adults, due to various factors including undeveloped immune and respiratory systems and inhalation rates. Thus, the purpose of this study was to determine indoor UFP number concentrations in Portuguese primary schools. Ultrafine particles were sampled between January and March 2014 in 10 public primary schools (35 classrooms) located in Porto, Portugal. Overall, the average indoor UFP number concentrations were not significantly different from outdoor concentrations (8.69 × 10(3) vs. 9.25 × 10(3) pt/cm(3), respectively; considering 6.5 h of indoor occupancy). Classrooms with distinct characteristics showed different trends of indoor UFP concentrations. The levels of carbon dioxide were negatively correlated with indoor UFP concentrations. Occupational density was significantly and positively correlated with UFP concentrations. Although the obtained results need to be interpreted with caution since there are no guidelines for UFP levels, special attention needs to be given to source control strategies in order to reduce major particle emissions and ensure good indoor air quality.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Surface ozone is formed in the presence of NOx (NO + NO2) and volatile organic compounds (VOCs) and is hazardous to human health. A better understanding of these precursors is needed for developing effective policies to improve air quality. To evaluate the year-to-year changes in source contributions to total VOCs, Positive Matrix Factorization (PMF) was used to perform source apportionment using available hourly observations from June through August at a Photochemical Assessment Monitoring Station (PAMS) in Essex, MD for each year from 2007-2015. Results suggest that while gasoline and vehicle exhaust emissions have fallen, the contribution of natural gas sources to total VOCs has risen. To investigate this increasing natural gas influence, ethane measurements from PAMS sites in Essex, MD and Washington, D.C. were examined. Following a period of decline, daytime ethane concentrations have increased significantly after 2009. This trend appears to be linked with the rapid shale gas production in upwind, neighboring states, especially Pennsylvania and West Virginia. Back-trajectory analyses similarly show that ethane concentrations at these monitors were significantly greater if air parcels had passed through counties containing a high density of unconventional natural gas wells. In addition to VOC emissions, the compressors and engines involved with hydraulic fracturing operations also emit NOx and particulate matter (PM). The Community Multi-scale Air Quality (CMAQ) Model was used to simulate air quality for the Eastern U.S. in 2020, including emissions from shale gas operations in the Appalachian Basin. Predicted concentrations of ozone and PM show the largest decreases when these natural gas resources are hypothetically used to convert coal-fired power plants, despite the increased emissions from hydraulic fracturing operations expanded into all possible shale regions in the Appalachian Basin. While not as clean as burning natural gas, emissions of NOx from coal-fired power plants can be reduced by utilizing post-combustion controls. However, even though capital investment has already been made, these controls are not always operated at optimal rates. CMAQ simulations for the Eastern U.S. in 2018 show ozone concentrations decrease by ~5 ppb when controls on coal-fired power plants limit NOx emissions to historically best rates.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Instituto de Química, Programa de Pós-Graduação em Tecnologia Química e Biológica, 2016.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Homogeneous Charge Compression Ignition (HCCI) engine is a promising combustion concept for reducing NOx and particulate matter (PM) emissions and providing a high thermal efficiency in internal combustion engines. This concept though has limitations in the areas of combustion control and achieving stable combustion at high loads. For HCCI to be a viable option for on-road vehicles, further understanding of its combustion phenomenon and its control are essential. Thus, this thesis has a focus on both the experimental setup of an HCCI engine at Michigan Technological University (MTU) and also developing a physical numerical simulation model called the Sequential Model for Residual Affected HCCI (SMRH) to investigate performance of HCCI engines. The primary focus is on understanding the effects of intake and exhaust valve timings on HCCI combustion. For the experimental studies, this thesis provided the contributions for development of HCCI setup at MTU. In particular, this thesis made contributions in the areas of measurement of valve profiles, measurement of piston to valve contact clearance for procuring new pistons for further studies of high geometric compression ratio HCCI engines. It also consists of developing and testing a supercharging station and the setup of an electrical air heater to extend the HCCI operating region. The HCCI engine setup is based on a GM 2.0 L LHU Gen 1 engine which is a direct injected engine with variable valve timing (VVT) capabilities. For the simulation studies, a computationally efficient modeling platform has been developed and validated against experimental data from a single cylinder HCCI engine. In-cylinder pressure trace, combustion phasing (CA10, CA50, BD) and performance metrics IMEP, thermal efficiency, and CO emission are found to be in good agreement with experimental data for different operating conditions. Effects of phasing intake and exhaust valves are analyzed using SMRH. In addition, a novel index called Fuel Efficiency and Emissions (FEE) index is defined and is used to determine the optimal valve timings for engine operation through the use of FEE contour maps.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Mt. Bachelor Observatory (MBO) is a high altitude atmospheric research station that is located at the Mt. Bachelor ski area in Central Oregon. The observatory was started by Prof. Dan Jaffe in 2004. Over this time, his time at UW has made observations of ozone, carbon monoxide, mercury, nitrogen oxides, particulate matter and other atmospheric constituents. The data for 2015 are reported in this dataset. MBO coordinates (summit building): Latitude: 43.9775 N Longitude: 121.6861 W Elevation: 2.74 km asl

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introducción El material particulado son partículas sólidas y líquidas emitidas al aire, las cuales pueden generar diferentes alteraciones en la salud, variando desde cuadros respiratorios alérgicos, a episodios asmáticos, dermatitis o inclusive llegar a facilitar la génesis de enfermedades de tipo neoplásico. Estos pueden tener origen natural e industrial, encontrandose en diferentes actividades económicas. Objetivo Evaluar la exposición laboral a material particulado en empresas pertenecientes a diferentes sectores económicos afiliadas a una ARL en Colombia, en el periodo comprendido entre 2011 al 2014 Metodología Es un estudio de corte transversal, analizando una base de datos de 257 empresas con 1108 mediciones de material particulado, recolectados entre 2011 – 2014. Las variables usadas fueron: región, actividad económica, área, oficio, tiempo de exposición y concentración de material particulado. Se realizó distribuciones de frecuencia, medidas de tendencia central y de dispersión. Se evaluaron las diferencias de las distribuciones de los tiempos de exposición y el porcentaje de exposición entre los grupos con y sin riesgo (los que sobrepasaban o no los límites permisibles), con la prueba asintótica no paramétrica de Mann Whitney. Resultados Las principales mediciones ambientales en las empresas fueron en la industria química con un 31%, siendo 2 de cada 3 datos pertenecientes a la región andina, las cuales tienen como principales contaminantes químicos las partículas no fraccionadas con el 70,9%. Respecto a las concentraciones ambientales de material particulado en las empresas participantes, se encontró un promedio de 1,72 mg/m3 ± 3,613, con una mediana de 0,480 mg/m3 y un coeficiente de variación de 210,05%. El 2,9% sobrepasaron los valores límites establecidos por la ACGIH (American Conference of Governmental Industrial Hygienists) y el 92,5% según los límites de la EPA (Agencia de Protección del Ambiente), presentando mayor riesgo en el personal operativo con 93,3% (p= 0,002). Conclusión El riesgo según los límites establecidos por la ACGIH para las mediciones realizadas en Colombia fue bajo, aunque al utilizar los parámetros de la EPA, el riesgo fue alto, por lo cual se requiere hacer un seguimiento específico a estas empresas y fomentar la implementación del sistema de gestión en seguridad y salud en el trabajo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The pollutant transference among reservoirs atmosphere-hydrosphere, relevant to the atmospheric chemistry, depends upon scavenging coefficient (Λ) calculus, which depends on the raindrop size distribution as well as on the rainfall systems, both different to each locality. In this work, the Λ calculus will be evaluated to gas SO2 and particulate matter fine and coarse among five sites in Germany and two in Brazil. The results show three possible classifications in function of Λ, comparable to literature, however with a greater range due to the differences of rainfall system sites. This preliminary study supports future researches

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo do presente estudo é caracterizar a hidrodinâmica e o transporte de material particulado em suspensão (MPS) no estuário de Caravelas sob diferentes condições de maré e vazão fluvial. Foram realizadas quatro campanhas hidrográficas durante ciclos completos de maré, sendo em condições de maré de sizígia e quadratura, e durante os períodos seco e chuvoso. Dados de nível de água, velocidade e direção de correntes, salinidade, temperatura e turbidez foram obtidos em uma estação fixa próxima da desembocadura do estuário. A partir destes dados foram obtidos os transportes residuais de MPS e calculado os mecanismos de transporte. As maiores concentrações médias de material particulado em suspensão ocorreram em condições de sizígia. Em condições de maré de quadraturao transporte resultante de MPS foi com sentido estuário acima, porém de pequena intensidade. Em condições de sizígia o estuário é caracterizado por correntes mais intensas e assimétricas, com dominância de vazante. Durante a condição de sizígia o estuário pode atuar como importador ou exportador de MPS. O estuário do rio Caravelas foi classificado como bem misturado e fracamente estratificado. A hidrografia e o balanço sedimentar são principalmente modulados pela altura da marée o aporte de água doce é irrelevante.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A previous mathematical model explaining dengue in Singapore predicted a reasonable outbreak of about 6500 cases for 2006 and a very mild outbreak with about 2000 cases for 2007. However, only 3051 cases were reported in 2006 while more than 7800 were reported in the first 44 weeks of 2007. We hypothesized that the combination of haze with other local sources of particulate matter had a significant impact on mosquito life expectancy, significantly increasing their mortality rate. To test the hypothesis a mathematical model based on the reproduction number of dengue fever and aimed at comparing the impact of several possible alternative control strategies was proposed. This model also aimed at contributing to the understanding of the causes of dengue resurgence in Singapore in the last decade. The model`s simulation demonstrated that an increase in mosquito mortality in 2006 and either a reduction in mortality or an increase in the carrying capacity of mosquitoes in 2007 explained the patterned observed in Singapore. Based on the model`s simulation we concluded that the fewer than expected number of dengue cases in Singapore in 2006 was caused by an increase in mosquito mortality due to the disproportionate haze affecting the country that year and that particularly favourable environmental conditions in 2007 propitiated mosquitoes with a lower mortality rate, which explains the greater than expected number of dengue cases in 2007. Whether our hypothesis is plausible or not should be debated further.