910 resultados para Advanced and Specialised Nursing


Relevância:

40.00% 40.00%

Publicador:

Resumo:

An experiment was conducted to evaluate the effects of control of carbon/nitrogen ratio (C/N ratio) by addition of low cost carbohydrate to the water column on water quality and pond ecology in freshwater prawn Macrobrachium rosenbergii post-larvae nursing system. In this experiment, two level of dietary protein 20% and 35% without carbohydrate addition (‘P20' and ‘P35') and with carbohydrate addition (‘P20+CH' and ‘P35+CH') were compared in small ponds of 40 m² area stocked with 20 post-larvae (0.021 ± 0.001g) per m² . Maize flour was used as low cost carbohydrate and applied to the water column followed by the first feeding during the day. The addition of carbohydrate significantly reduced (p< 0.05) ammonia-nitrogen (NH sub(3)-N) and nitrite-nitrogen (NO sub(2) - N) of water in P20 + CH and P35 + CH treatments. It significantly increased (p< 0.05) the total heterotrophic bacteria (THB) population both in water and sediment. Fifty nine genera of plankton were identified belonging to the Bacillariophyceae (11), Chlorophyceae (21), Cyanophyceae (7), Dinophyceae (1), Rotifera (7) and Crustacea (9) without any significant difference (p>0.05) of total phytoplankton and zooplankton among the treatments. Survival rate of prawn was significantly lowest (p<0.05) in P20 and no significant difference (p>0.05) was observed between P20+CH and P35 treatments. Control of C/N ratio by the addition of low-cost carbohydrate to the pond water column benefited the freshwater prawn nursing practices in three ways (1) increased heterotrophic bacterial growth supplying bacterial protein augment the prawn post-larvae growth performances, (2) reduced demand for supplemental feed protein and subsequent reduction in feed cost and (3) reduced toxic NH sub(3)-N and NO sub(2)-N levels in pond nursing system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Since the discovery of Carbon Nanotubes (CNTs) by Iijima in 1991[1, 2], there has been an explosion of research into the physical and chemical properties of this novel material. CNT based biosensors can play an important role in amperometric, immunosensor and nucleic-acid sensing devices, e.g. for detection of life threatening biological agents in time of war or in terrorist attacks, saving life and money for the NHS. CNTs offer unique advantages in several areas, like high surfacevolume ratio, high electrical conductivity, chemical stability and strong mechanical strength, and CNT based sensors generally have higher sensitivities and lower detection limit than conventional ones. In this review, recent advances in biosensors utilising carbon nanotubes and carbon nanotube fibres will be discussed. The synthesis methods, nanostructure approaches and current developments in biosensors using CNTs will be introduced in the first part. In the second part, the synthesis methods and up-to-date progress in CNT fibre biosensors will be reviewed. Finally, we briefly outline some exciting applications for CNT and CNT fibres which are being targeted. By harnessing the continual advancements in micro and nano- technology, the functionality and capability of CNT-based biosensors will be enhanced, thus expanding and enriching the possible applications that can be delivered by these devices. © 2012 Bentham Science Publishers. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We demonstrate an uncooled WDM system using standard WDM components and receiver signal processing, with a different number of receivers to transmitters, to allow wide temperature drift of the transmitter lasers. A 100 Gb/s 8-wavelength demonstrator has been developed, which proves the feasibility of the approach over 25 km of SMF. © 2012 OSA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Heavy goods vehicles exhibit poor braking performance in emergency situations when compared to other vehicles. Part of the problem is caused by sluggish pneumatic brake actuators, which limit the control bandwidth of their antilock braking systems. In addition, heuristic control algorithms are used that do not achieve the maximum braking force throughout the stop. In this article, a novel braking system is introduced for pneumatically braked heavy goods vehicles. The conventional brake actuators are improved by placing high-bandwidth, binary-actuated valves directly on the brake chambers. A made-for-purpose valve is described. It achieves a switching delay of 3-4 ms in tests, which is an order of magnitude faster than solenoids in conventional anti-lock braking systems. The heuristic braking control algorithms are replaced with a wheel slip regulator based on sliding mode control. The combined actuator and slip controller are shown to reduce stopping distances on smooth and rough, high friction (μ = 0.9) surfaces by 10% and 27% respectively in hardware-in-the-loop tests compared with conventional ABS. On smooth and rough, low friction (μ = 0.2) surfaces, stopping distances are reduced by 23% and 25%, respectively. Moreover, the overall air reservoir size required on a heavy goods vehicle is governed by its air usage during an anti-lock braking stop on a low friction, smooth surface. The 37% reduction in air usage observed in hardware-in-the-loop tests on this surface therefore represents the potential reduction in reservoir size that could be achieved by the new system. © 2012 IMechE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We demonstrate an uncooled WDM system using standard WDM components and receiver signal processing, with a different number of receivers to transmitters, to allow wide temperature drift of the transmitter lasers. A 100 Gb/s 8-wavelength demonstrator has been developed, which proves the feasibility of the approach over 25 km of SMF. © 2012 Optical Society of America.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this review, the potential of mode-locked lasers based on advanced quantum-dot ( QD) active media to generate short optical pulses is analysed. A comprehensive review of experimental and theoretical work on related aspects is provided, including monolithic-cavity mode-locked QD lasers and external-cavity mode-locked QD lasers, as well as mode-locked solid-state and fibre lasers based on QD semiconductor saturable absorber mirrors. Performance comparisons are made for state-of-the-art experiments. Various methods for improving important characteristics of mode-locked pulses such as pulse duration, repetition rate, pulse power, and timing jitter through optimization of device design parameters or mode-locking methods are addressed. In addition, gain switching and self-pulsation of QD lasers are also briefly reviewed, concluding with the summary and prospects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Superconducting electron cyclotron resonance (ECR) ion source with advanced design in Lanzhou (SECRAL) is a next generation ECR ion source and aims for developing a very compact superconducting ECR ion source with a structure and high performances for highly charged ion-beam production. The ion source was designed to be operated at 18 GHz at initial operation and finally will be extended to 28 GHz. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. At full excitation, this magnet assembly can produce peak mirror fields on the axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. What is different from the traditional design, such as LBNL VENUS and LNS SERSE, is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. SECRAL may open the way for building a compact and high-performance 18-28 GHz superconducting ECR ion source. Very preliminary commissioning results are promising. Detailed design, construction issues and very preliminary test results of the ion source at 18 GHz are presented.