965 resultados para z-scan


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spontaneous pneumothorax in children is an emergency. A rapid and structured treatment is necessary. Indicating clinical signs are dyspnoea with unilateral reduced breath sounds and hypersonic percussion note. Chest x-ray confirms diagnosis. CT scan shows detailed information's of pathological changes in lung tissue and offers important considerations for the therapy. Today video assisted thoracoscopic surgery (VATS) takes a central role in the treatment of spontaneous pneumothorax. Thoracoscopy completes diagnosis detecting the pathologies, which were missed in imaging procedures. Definitive surgical treatment is performed simultaneously in the same anaesthesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: During paravertebral block, the anterolateral limit of the paravertebral space, which consists of the pleura, should preferably not be perforated. Also it is possible that, during the block, the constant superior costotransverse ligament can be missed in the loss-of-resistance technique. We therefore aimed to develop a new technique for an ultrasound-guided puncture of the paravertebral space. METHODS: We performed 20 punctures and catheter placements in 10 human cadavers. A sonographic view showing the pleura and the superior costotransverse ligament was obtained with a slightly oblique scan using a curved array transducer. After inline approach, injection of 10 ml normal saline confirmed the correct position of the needle tip, distended the space, and enabled catheter insertion. The spread of contrast dye injected through the catheters was assessed by CT scans. RESULTS: The superior costotransverse ligament and the paravertebral space were easy to identify. The needle tip reached the paravertebral space without problems under visualization. In contrast, the introduction of the catheter was difficult. The CT scan revealed a correct paravertebral spread of contrast in 11 cases. Out of the remaining, one catheter was found in the pleural space, in six cases there was an epidural, and in two cases there was a prevertebral spread of contrast dye. CONCLUSIONS: We successfully developed a technique for an accurate ultrasound-guided puncture of the paravertebral space. We also showed that when a catheter is introduced through the needle with the tip lying in the paravertebral space, there is a high probability of catheter misplacement into the epidural, mediastinal, or pleural spaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study was to evaluate the feasibility and reproducibility of high-resolution magnetic resonance imaging (MRI) and quantitative T2 mapping of the talocrural cartilage within a clinically applicable scan time using a new dedicated ankle coil and high-field MRI. MATERIALS AND METHODS: Ten healthy volunteers (mean age 32.4 years) underwent MRI of the ankle. As morphological sequences, proton density fat-suppressed turbo spin echo (PD-FS-TSE), as a reference, was compared with 3D true fast imaging with steady-state precession (TrueFISP). Furthermore, biochemical quantitative T2 imaging was prepared using a multi-echo spin-echo T2 approach. Data analysis was performed three times each by three different observers on sagittal slices, planned on the isotropic 3D-TrueFISP; as a morphological parameter, cartilage thickness was assessed and for T2 relaxation times, region-of-interest (ROI) evaluation was done. Reproducibility was determined as a coefficient of variation (CV) for each volunteer; averaged as root mean square (RMSA) given as a percentage; statistical evaluation was done using analysis of variance. RESULTS: Cartilage thickness of the talocrural joint showed significantly higher values for the 3D-TrueFISP (ranging from 1.07 to 1.14 mm) compared with the PD-FS-TSE (ranging from 0.74 to 0.99 mm); however, both morphological sequences showed comparable good results with RMSA of 7.1 to 8.5%. Regarding quantitative T2 mapping, measurements showed T2 relaxation times of about 54 ms with an excellent reproducibility (RMSA) ranging from 3.2 to 4.7%. CONCLUSION: In our study the assessment of cartilage thickness and T2 relaxation times could be performed with high reproducibility in a clinically realizable scan time, demonstrating new possibilities for further investigations into patient groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 72-year old woman with known metastatic breast cancer who presented to the emergency department with progressive dyspnea on exertion and chest pain. The diagnosis of pulmonary embolism could be established by pulmonary scintigraphy after computed tomography and ultrasound of the lower extremities had been negative in spite of a moderate clinical pretest probability (Wells score). This case shows that even if we manage suspected pulmonary embolism using algorithms combining clinical probability, computed tomography and ultrasound we must remain aware of eventually missing the diagnosis and carry on investigating cases with elevated clinical probability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on a 36-year-old man with a history of mild head trauma. The initial clinical findings and the CT-scan of the brain revealed no pathological result, although the patient suffered from weakness of the right arm and bilateral blindness. Those findings were interpreted as psychogenic disorder. Nine days later he developed an instable gait, a child like attitude, amnesia and enuresis. The CT-scan revealed a subacute bilateral occipital stroke in the region of the arteriae cerebri posteriors. No cause for the stroke was found. In spite of the rareness of cortical blindness in young people as a cause of stroke, a detailed medical history and clinical examination should always be performed, and by unclearness additional investigations should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heutzutage stehen zunehmend – z.B. durch den raschen Fortschritt bei den bildgebenden Verfahren – digitale Datensätze im Dentalbereich zur Verfügung. CAD/CAM-syteme gehören dabei in der Zahntechnik längst zum Stande der Technik. Für die Anwendung derartiger Systeme ist jedoch ein Gipsmodell nötig, welches zum Beginn der Prozesskette vom Zahntechniker mittels eines optischen Scanners digitalisiert wird. Die Weiterentwicklung intraoraler Scanner ermöglicht heutzutage außerdem die Digitalisierung ganzer Kiefer im Patientenmund durch den Zahnarzt. Insbesondere für z.B. die ästhetischen Restaurationen bildet hier das zahntechnische Modell nach wie vor die unersetzliche Arbeitsgrundlage für den Techniker. In der vorliegenden Arbeit wird dazu ein Rapid Manufacturing Verfahren zur Herstellung von Dentalmodellen auf Basis der Stereolithographie vorgestellt. Dabei wird auf die besonderen Anforderungen hinsichtlich Präzision, Robustheit und Wirtschaftlichkeit von generativen Fertigungsverfahren für dentale Applikationen eingegangen und eine neu entwickelte Baustrategie vorgestellt, mittels derer die o.g. Anforderungen erfüllt werden

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recurrent airway obstruction (RAO), or heaves, is a naturally occurring asthma-like disease that is related to sensitisation and exposure to mouldy hay and has a familial basis with a complex mode of inheritance. A genome-wide scanning approach using two half-sibling families was taken in order to locate the chromosome regions that contribute to the inherited component of this condition in these families. Initially, a panel of 250 microsatellite markers, which were chosen as a well-spaced, polymorphic selection covering the 31 equine autosomes, was used to genotype the two half-sibling families, which comprised in total 239 Warmblood horses. Subsequently, supplementary markers were added for a total of 315 genotyped markers. Each half-sibling family is focused around a severely RAO-affected stallion, and the phenotype of each individual was assessed for RAO and related signs, namely, breathing effort at rest, breathing effort at work, coughing, and nasal discharge, using an owner-based questionnaire. Analysis using a regression method for half-sibling family structures was performed using RAO and each of the composite clinical signs separately; two chromosome regions (on ECA13 and ECA15) showed a genome-wide significant association with RAO at P < 0.05. An additional 11 chromosome regions showed a more modest association. This is the first publication that describes the mapping of genetic loci involved in RAO. Several candidate genes are located in these regions, a number of which are interleukins. These are important signalling molecules that are intricately involved in the control of the immune response and are therefore good positional candidates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To describe the most reliable insertion angle, corridor length and width to place a ventral transarticular atlantoaxial screw in miniature breed dogs. STUDY DESIGN: Retrospective CT imaging study. SAMPLE POPULATION: Cervical CT scans of toy breed dogs (n = 21). METHODS: Dogs were divided into 2 groups--group 1: no atlantoaxial abnormalities; group 2: atlantoaxial instability. Insertion angle in medial to lateral and ventral to dorsal direction was measured in group 1. Corridor length and width were measured in groups 1 and 2. Corridor width was measured at 3 points of the corridor. Each variable was measured 3 times and the mean used for statistical analysis. RESULTS: Mean +/- SD optimal transarticular atlantoaxial insertion angle was determined to be 40 +/- 1 degrees in medial to lateral direction from the midline and 20 +/- 1 degrees in ventral to dorsal direction from the floor of the neural canal of C2. Mean corridor length was 7 mm (range, 4.5-8.0 mm). Significant correlation was found between corridor length, body weight, and age. Mean bone corridor width ranged from 3 to 5 mm. Statistically significant differences were found between individuals, gender and measured side. CONCLUSIONS: Optimal placement of a transarticular screw for atlantoaxial joint stabilization is very demanding because the screw path corridor is very narrow.