998 resultados para volume-sensitive reflex
Resumo:
The toxicity and environmental behavior of new pH-sensitive surfactants from lysine are presented. Three different chemical structures are studied: surfactants with one amino acid and one alkyl chain, surfactants with two amino acids on the polar head and one alkyl chain, and gemini surfactants. The pH sensitivity of these compounds can be tuned by modifying their chemical structures. Cytotoxicity has been evaluated using erythrocytes and fibroblast cells. The toxic effects against these cells depend on the hydrophobicity of the molecules as well as their cationic charge density. The effect of hydrophobicity and cationic charge density on toxicity is different for each type of cells. For erythrocytes, the toxicity increases as hydrophobicity and charge density increases. Nevertheless, for fibroblasts cationic charge density affects cytotoxicity in the opposite way: the higher charge density, the lower the toxicity. The effect of the pH on hemolysis has been evaluated in detail. The aquatic toxicity was established using Daphnia magna. All surfactants yielded EC50 values considerably higher than that reported for cationic surfactants based on quaternary ammonium groups. Finally, their biodegradability was evaluated using the CO2 headspace test (ISO 14593). These lysine derivatives showed high levels of biodegradation under aerobic conditions and can be classified as"readily biodegradable compounds".
Resumo:
BACKGROUND: Regional rates of hospitalization for ambulatory care sensitive conditions (ACSC) are used to compare the availability and quality of ambulatory care but the risk adjustment for population health status is often minimal. The objectives of the study was to examine the impact of more extensive risk adjustment on regional comparisons and to investigate the relationship between various area-level factors and the properly adjusted rates. METHODS: Our study is an observational study based on routine data of 2 million anonymous insured in 26 Swiss cantons followed over one or two years. A binomial negative regression was modeled with increasingly detailed information on health status (age and gender only, inpatient diagnoses, outpatient conditions inferred from dispensed drugs and frequency of physician visits). Hospitalizations for ACSC were identified from principal diagnoses detecting 19 conditions, with an updated list of ICD-10 diagnostic codes. Co-morbidities and surgical procedures were used as exclusion criteria to improve the specificity of the detection of potentially avoidable hospitalizations. The impact of the adjustment approaches was measured by changes in the standardized ratios calculated with and without other data besides age and gender. RESULTS: 25% of cases identified by inpatient main diagnoses were removed by applying exclusion criteria. Cantonal ACSC hospitalizations rates varied from to 1.4 to 8.9 per 1,000 insured, per year. Morbidity inferred from diagnoses and drugs dramatically increased the predictive performance, the greatest effect found for conditions linked to an ACSC. More visits were associated with fewer PAH although very high users were at greater risk and subjects who had not consulted at negligible risk. By maximizing health status adjustment, two thirds of the cantons changed their adjusted ratio by more than 10 percent. Cantonal variations remained substantial but unexplained by supply or demand. CONCLUSION: Additional adjustment for health status is required when using ACSC to monitor ambulatory care. Drug-inferred morbidities are a promising approach.
Resumo:
BACKGROUND: Reading volume and mammography screening performance appear positively correlated. Quality and effectiveness were compared across low-volume screening programmes targeting relatively small populations and operating under the same decentralised healthcare system. Except for accreditation of 2nd readers (restrictive vs non-restrictive strategy), these organised programmes had similar screening regimen/procedures and duration, which maximises comparability. Variation in performance and its determinants were explored in order to improve mammography practice and optimise screening performance. METHODS: Circa 200,000 screens performed between 1999 and 2006 (4 rounds) in 3 longest standing Swiss cantonal programmes (of Vaud, Geneva and Valais) were assessed. Indicators of quality and effectiveness were assessed according to European standards. Interval cancers were identified through linkage with cancer registries records. RESULTS: Swiss programmes met most European standards of performance with a substantial, favourable cancer stage shift. Up to a two-fold variation occurred for several performance indicators. In subsequent rounds, compared with programmes (Vaud and Geneva) that applied a restrictive selection strategy for 2nd readers, proportions of in situ lesions and of small cancers (≤1cm) were one third lower and halved, respectively, and the proportion of advanced lesions (stage II+) nearly 50% higher in the programme without a restrictive selection strategy. Discrepancy in second-year proportional incidence of interval cancers appears to be multicausal. CONCLUSION: Differences in performance could partly be explained by a selective strategy for second readers and a prior experience in service screening, but not by the levels of opportunistic screening and programme attendance. This study provides clues for enhancing mammography screening performance in low-volume programmes.
Resumo:
Ce travail concerne les 26 premiers patients opérés à Lausanne de juillet 1995 à avril 1998 d?une gie de réduction de volume pulmonaire pour un emphysème sévère. Il présente leurs actéristiques préopératoires générales, leur évaluation radiologique et cardiologique, ainsi que mesures fonctionnelles pulmonaires. Il examine ensuite la technique opératoire, la période ériopératoire, ainsi que les résultats fonctionnels postopératoires des patients. De plus il présente les entretiens ayant eu lieu avec chaque patient pour connaître son évaluation de l?opération et de ges résultats. Ces informations sont ensuite comparées avec les résultats présents dans la littérature. Le profil préopératoire, la technique opératoire, la période péripopératoire, et les résultats fonctionnels postopératoires sont comparés. Un groupe de patients qui n?a pas répondu au point de vue fonctionnel A la chirurgie est ensuite examiné afin de tenter de définir des critères préopératoires de bonne ou mauvaise réponse, et ceux-ci sont mis en relation avec les données de la littérature. On compare ensuite le groupe de mauvais répondeurs fonctionnels avec le groupe des patients ne s?estimant pas améliorés par l?opération. En faisant une étude statistiques des valeurs fonctionnelles pré et postopératoire, on observe une amélioration significative du VEMS, du volume résiduel, de la PaC02, de la distance parcounie au test de marche de six minutes et de la dyspnée engendrée par le test sur une échelle de Borg. L?amélioration de la Pa02 postopératoire et de la saturation en oxygène pendant le test de marche n?était pas significative statistiquement. On peut voir que ce collectif de patients lausannois est comparable aux autres séries au niveau du profil préopératoire et de la gravité de l?atteinte fonctionnelle, au niveau de la technique opératoire, de la mortalité et morbidité, et des résultats fonctionnels postopératoires. On observe comme différence un volume résiduel moyen préopératoire plus élevé et davantage amélioré en postopératoire que dans la littérature. Cette étude ne met pas en évidence - et c?est également le cas dans la littérature - de critères clairs préopératoires prédictifs d?une bonne réponse à la chirurgie. De même elle n?a pas mis en évidence de concordance entre l?amélioration de la symptomatologie des patients et les résultats fonctionnels postopératoires. 11 serait donc intéressant de poursuivre ce travail par une évaluation prospective plus systématique des patients opérés et de pouvoir la comparer avec les résultats des patients récusés ou refusant la chirurgie de réduction de volume pulmonaire, afin de pouvoir mieux en évaluer les bénéfices à long terme.
Resumo:
Abstract The epithelial sodium channel (ENaC) is composed of three homologous subunits α, ß, and γ. This channel is involved in the regulation of sodium balance, which influences the periciliary liquid level in the lung, and blood pressure via the kidney. ENaC expressed in Xenopus laevis oocytes is preferentially and rapidly assembled into heteromeric αßγ complexes. Expression of homomeric α or heteromeric αß and αγ complexes lead to channel expression at the cell surface wíth low activities. Recent studies have demonstrated that α and γ (but not ß) ENaC subunits undergo proteolytic cleavage by endogenous proteases (i.e. furin) correlating with increased channel activity. We therefore assayed the full-length subunits and their cleavage products at the cell surface, as well as in the intracellular pool for all homo- and heteromeric combínations (α, ß, γ, ßγ, αß, αγ, ßγ and αßγ) and measured the corresponding channel activities as amiloride-sensitive sodíum transport (INa). We showed that upon assembly, cleavage of the y ENaC subunit ís responsible for increasing INa. We further demonstrated that in disease states such as cystic fibrosis (CF) where there is disequilibrium in the proteaseprotease inhibitor balance, ENaC is over-activated by the serine protease elastase (NE). We demonstrated that elevated NE concentrations can cleave cell surface expressed γ ENaC (but not α, or ß ENaC), suggesting a causal relationship between γ ENaC cleavage and ENaC activation, taking place at the plasma membrane. In addition, we demonstrated that the serine protease inhibitor (serpin) serpinH1, which is co-expressed with ENaC in the distal nephron is capable of inhibiting the channel by preventing cleavage of the γ ENaC subunit. Aldosterone mediated increases in INa aze known to be inhibted by TGFß. TGFß is also known to increase serpinHl expression. The demonstrated inhibition of γ ENaC cleavage and channel activation by serpinH1 may be responsible for the effect of TGFß on aldosterone stimulation in the distal nephron. In summary, we show that cleavage of the γ subunit, but not the α or ß subunit is linked to channel activation in three seperate contexts. Résumé Le canal épithélial à sodium (ENaC) est constitué de trois sous-unités homologues α, ß, and γ. Ce canal est impliqué dans le maintien de la balance sodique qui influence le niveau du liquide périciliaire du poumon et la pression sanguine via le rein. Dans les ovocytes de Xenopus laevis ENaC est préférentiellement et rapidement exprimé en formant un complexe hétéromérique αßγ. En revanche, l'expression homomérique de α ou hétéromérique des complexes αß et αγ conduit à une expression à la surface cellulaire d'un canal ENaC ne possédant qu'une faible activité. Des études récentes ont mis en évidence que les sous-unités α et γ d'ENaC (mais pas ß) sont coupées par des protéases endogènes (les farines) et que ces clivages augmentent l'activité du canal. Nous avons donc analysé, aussi bien à la surface cellulaire que dans le cytoplasme, les produits des clivages de combinaison homo- et hétéromérique des sous-unités d'ENaC (α, ß, γ, ßγ, αß, αγ, ßγ et αßγ). En parallèle, nous avons étudié l'activité correspondante à ces canaux par la mesure du transport de sodium sensible à l'amiloride (INa). Nous avons montré que lors de l'assemblage des sous-unités d'ENaC, le clivage de γ correspond à l'augmentation de INa. Nous avons également mis en évidence que dans une maladie telle que la fibrose cystique (CF) caractérisée par un déséquilibre de la balance protéase-inhibiteur de protéase, ENaC est suractivé par une sérine protéase nommée élastase (NE). L'augmentation de la concentration de NE clive γ ENaC exprimé à la surface cellulaire (mais pas α, ni ß ENaC) suggérant une causalité entre le clivage d'ENaC et son activation à la membrane plasmique. De plus, nous avons démontré que l'inhibiteur de sérine protéase (serpin) serpinH1, qui est co-exprimé avec ENaC dans le néphron distal, inhibe l'activité du canal en empêchant le clivage de la sous-unité γ ENaC. Il est connu que le INa induit par l'aldostérone peut être inhibé par TGFß. Or TGFß augmente l'expression de serpinH1. L'inhibition du clivage de γ ENaC et de l'activation du canal par la serpinH1 que nous avons mis en évidence pourrait ainsi être responsable de l'effet de TGFß sur la stimulation du courant par l'aldostérone dans le néphron distal. En résumé, nous avons montré que le clivage de la sous-unité γ, mais pas des sous-unités α et ß, est lié à l'activation du canal dans trois contextes distincts. Résumé tout public Le corps humain est composé d'environ 10 000 milliards de cellules et d'approximativement 60% d'eau. Les cellules du corps sont les unités fondamentales de la vie et elles sont dépendantes de certains nutriments et molécules. Ces nutriments et molécules sont dissous dans l'eau qui est présente dans et hors des cellules. Le maintien d'une concentration adéquate - de ces nutriments et de ces molécules dans l'eau à l'intérieur et à l'extérieur des cellules est -..essentiel pour leur survie. L'eau hors des cellules est nommée le fluide extracellulaire et peut être subdivisée en fluide interstitiel, qui se trouve autour des cellules, et en plasma, qui est le fluide des vaisseaux sanguins. Les fluides, les nutriments et les molécules sont constamment échangés entre les cellules, le fluide interstitiel, et le plasma. Le plasma circule dans le système circulatoire afin de distribuer les nutriments et molécules dans tout le corps et afin d'enlever les déchets cellulaires. Le rein joue un rôle essentiel dans la régulation du volume et de la concentration du plasma en éliminant sélectivement les nutriments et les molécules via la formation de l'urine. L'être humain possède deux reins, constitués chacun d'environ 1 million de néphrons. Ces derniers sont responsables de réabsorber et de sécréter sélectivement les nutriments et les molécules. Le canal épithélial à sodium (ENaC) est localisé à la surface cellulaire des néphrons et est responsable de la réabsorption du sodium (Na+). Le Na+ est présent dans quasiment toute la nourriture que nous mangeons et représente, en terme de molécule, 50% du sel de cuisine. Si trop de sodium est consommé, ENaC est inactif, si bien que le Na+ n'est pas réabsorbé et quitte le corps par l'urine. Ce mécanisme permet d'éviter que la concentration plasmatique de Na+ ne devienne trop grande, ce qui résulterait en une augmentation de la pression sanguine. Si trop peu de Na+ est consommé, ENaC réabsorbe le Na+ de l'urine primaire ce qui permet de conserver la concentration de Na+ et de prévenir une diminution de la pression sanguine par une perte de Na+. ENaC est aussi présent dans les cellules des poumons qui sont les organes permettant la respiration. La respiration est aussi essentielle pour la survie des cellules. Les poumons ne doivent pas contenir trop de liquide afin de permettre la respiration, mais en même temps ils ne doivent pas non plus être trop secs. En effet, ceci tuerait les cellules et empêcherait aussi la respiration. ENaC permet de maintenir un niveau d'humidité approprié dans les poumons en absorbant du Na+ ce qui entraîne un mouvement osmotique d'eau. L'absorption de sodium par ENaC ~ est augmentée par les protéases (in vitro et ex vivo). Les protéases sont des molécules qui peuvent couper d'autres molécules à des endroits précis. Nous avons démonté que certaines protéases augmentent l'absorption de Na+ en coupant ENaC à des endroits spécifiques. L'inhibition de ces protéases diminue le transport de Na+ et empêche le clivage d'ENaC. Dans certaines maladies telle que la mucoviscidose, des protéases sont suractivées et augmentent l'activité d'ENaC de manière inappropriée conduisant à une trop forte absorption de Na+ et à un déséquilibre de la muqueuse des poumons. Cette étude est donc particulièrement importante dans le cadre de la recherche thérapeutique de ce genre de maladie.
Resumo:
Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.
Resumo:
Collection : Publications hors série de l'École française d'Extrême-Orient
Resumo:
Collection : Publications hors série de l'École française d'Extrême-Orient
Resumo:
In this work we will prove that SiC-based MIS capacitors can work in environments with extremely high concentrations of water vapor and still be sensitive to hydrogen, CO and hydrocarbons, making these devices suitable for monitoring the exhaust gases of hydrogen or hydrocarbons based fuel cells. Under the harshest conditions (45% of water vapor by volume ratio to nitrogen), Pt/TaOx/SiO2/SiC MIS capacitors are able to detect the presence of 1 ppm of hydrogen, 2 ppm of CO, 100 ppm of ethane or 20 ppm of ethene, concentrations that are far below the legal permissible exposure limits.