907 resultados para two-step process
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
To assess the cytotoxicity of 35% hydrogen peroxide (HP) bleaching gel applied for 15 min to sound or restored teeth with two-step self-etching adhesive systems and composite resin. Materials and Methods: Sound and restored enamel/dentin disks were stored in water for 24 h or 6 months + thermocycling. The disks were adapted to artificial pulp chambers and placed in compartments containing culture medium. Immediately after bleaching, the culture medium in contact with dentin was applied for 1 h to previously cultured odontoblast-like MDPC-23 cells. Thereafter, cell viability (MTT assay) and morphology (SEM) were assessed. Data were analyzed by two-way ANOVA and Tukey's test (a = 5%). Results: In comparison to the negative control group (no treatment), no significant cell viability reduction occurred in those groups in which sound teeth were bleached. However, a significant decrease in cell viability was observed in the adhesive-restored bleached groups compared to negative control. No significant difference among bleached groups was observed with respect to the presence of restoration and storage time. Conclusion: The application of 35% HP bleaching gel to sound teeth for 15 min does not cause toxic effects in pulp cells. When this bleaching protocol was performed in adhesive-restored teeth, a significant toxic effect occurred.
Resumo:
This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.
Resumo:
Objective: The aim of this study to investigate the effects of different polymerization protocols on the cuspal movement in class II composite restorations. Materials and methods: Human premolar teeth were prepared with class II cavities and then restored with composite and three-step and two-step etch-and-rinse adhesive systems under different curing techniques (n = 10). It was used a lightemittingdiode curing unit and the mode of polymerization were: standard (exposure for 40 seconds at 700 mW/cm2), pulse-delay (initial exposure for 6 seconds at 350 mW/cm2 followed by a resting period of 3 minutes and a final exposure of 37 seconds at 700 mW/cm2) and soft-start curing (exposure 10 seconds at 350 mW/cm2 and 35 seconds at 700 mW/cm2). The cuspal distance (µm) was measured before and after the restorative procedure and the difference was recorded as cuspal movement. The data were submitted to two-way ANOVA and Bonferroni test (p < 0.05). Results: The type of adhesive system did not influenced the cuspal movement for all the curing methods. Standard protocol showed the highest values of cuspal movement and was statistically different from the pulse-delay and soft-start curing modes. Conclusion: Although the cuspal displacement was not completely avoided, alternative methods of photocuring should be considered to minimize the clinical consequences of composites contraction stress.
Resumo:
The advent of new adhesive systems is making techniques and clinical protocols to become faster and simpler, however it does not reduce the importance of knowledge of the properties, characteristics and interaction of dental materials with the tooth structure. Among the adhesives that have recently emerged, highlight the self-etching systems, especially the two-step selfetching, in which the acid primer is available in a separate bottle from the adhesive. These adhesives have shown good results for bond strength, microleakage and postoperative sensitivity, being an option for direct adhesive restorations in anterior teeth. This way, the present case report describes the step-by-step making of a class IV restoration in an upper right central incisor using atwo-step adhesive system, obtaining satisfactory results.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The present study evaluated the chemopreventive potential of mate tea-like intake on mammary and colon carcinogenesis initiated by 7,12-dimethylbenz(a)antracene (DMBA) and 1,2-dimethylhydrazine (DMH) in female Swiss mice. After the initiation period, the animals received basal diet and organic mate tea-like, conventional mate tea-like, or green tea (positive control) at 2.0% as the drinking fluid during 15 weeks. At week 20, colon and mammary gland were analyzed for preneoplastic and neoplastic lesions development. Colon and mammary gland complexes were processed for cell proliferation analysis, estimated by proliferating cell nuclear antigen labeling index (PCNA-LI%). Specially, organic mate tea-like reduced the values of PCNA-LI% in colonic crypts (p < .003) and in mammary glands (p < .05) in DMBA/DMH-initiated groups. A lower incidence of aberrant crypt foci (ACF) in colon (p = .03) and of hyperplastic and neoplastic lesions in mammary gland (p < .05 and p < .02, respectively) was observed in DMBA/DMH-initiated groups treated with organic mate tea-like. These results suggest that post-initiation treatment with organic mate tea-like inhibited the development of colon and mammary carcinogenesis in a two-step medium-term mouse carcinogenesis model.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Experimental etch/leach of Carboniferous Limestone gravels on a laboratory time-scale has demonstrated that 234U 238U activity ratios (AR's) greater than the radiochemical equilibrium value may be generated on short time-scales. The molar U/Ca and Mg/Ca ratios show that both U and Mg are leached preferentially relative to Ca whereas the molar U/Mg ratio is only slightly greater than that of the rock matrix. The generation of enhanced AR's is attributed to a two-stage process in which the limestone surface is dissolved by zero-order etch and silicate minerals so released are subjected to first-order chemical leach of U and Mg. The implications of these results for the production of enhanced AR's in Carboniferous Limestone groundwater are discussed. It is suggested that chemical leaching or exchange of U between groundwater and its particulate load or at the aquifer fluid-solid interface is an important mechanism controlling AR changes as groundwater migrates beyond a redox boundary. AR's for dissolved U in groundwater are more probably related to chemical equilibria than to groundwater age. © 1993.
Resumo:
The study of spermatogonial stem cells (SSCs) provides a model to better understand adult stem cell biology. Besides the biomedical potential to perform studies of infertility in many species, SSCs hold a promising application at animal transgenesis. Because stem cells are thought to be associated with basement membranes, expression of alpha-6 integrin has been investigated as a marker of type A spermatogonial cells, which are considered SSCs because of their undifferentiated status and self-renewal ability. In this manner, the aim of this study was to isolate type A SSCs from adult bulls by a two-step enzymatic procedure followed by a discontinuous Percoll density gradient purification and verify the expression of alpha-6 integrin by flow cytometry and real-time RT-PCR before and after Percoll purification. Spermatogonial cells were successfully obtained using the two-step enzymatic digestion. An average of 1 x 10(5) viable cells per gram of testis was isolated. However, the discontinuous Percoll did not purify isolated cells regarding alpha-6 integrin expression. Flow cytometry analysis demonstrated no differences in the alpha-6 integrin expression between cell samples before and after Percoll purification (p = 0.5636). The same was observed in the real-time PCR analysis (p > 0.05). In addition to alpha-6 integrin, the expression of GFR alpha-1 and PGP9.5, known bovine SSCs markers, was detected in all samples studied. Considering that Percoll can reduce cell viability, it is possible to conclude that Percoll density gradient is not suitable to purify bovine SSC, according to alpha-6 integrin expression.
Resumo:
Purpose: To assess the influence of ozone gas and ozonated water application to prepared cavity and bonded interfaces on the resin/dentin bond strength of two-step etch-and-rinse adhesive systems (Adper Single Bond 2 [SB2] and XP-Bond [XP]). Materials and Methods: Sixty extracted human third molars were sectioned perpendicularly to their long axes to expose flat occlusal dentin surfaces. In experiment 1, dentin was treated with ozone before the bonding procedure, while in experiment 2, ozone was applied to resin/dentin bonded interfaces. In experiment 1, dentin surfaces were treated either with ozone gas (2100 ppm), ozonated water (3.5 ppm), or distilled water for 120 s, and then bonded with SB2 or XP according to manufacturers' instructions. Hybrid composite buildups were incrementally constructed and the teeth were sectioned into resin-dentin sticks (0.8 mm(2)). In experiment 2, dentin surfaces were first bonded with SB2 or XP, composite buildups were constructed, and bonded sticks obtained. The sticks were treated with ozone as previously described. Bonded sticks were tested under tensile stress at 1 mm/min. Silver nitrate impregnation along the resin/dentin interfaces was also evaluated under SEM. Results: Two-way ANOVA (adhesive and ozone treatment) detected no significant effect for the cross-product interaction and the main factors in the two experiments (p > 0.05), which was confirmed by the photomicrographs. Conclusion: Ozone gas and ozonated water used before the bonding procedure or on resin/dentin bonded interfaces have no deleterious effects on the bond strengths and interfaces.