934 resultados para spontaneously generated coherence


Relevância:

20.00% 20.00%

Publicador:

Resumo:

EV is a child with a talent for learning language combined with Asperger syndrome. EV’s talent is evident in the unusual circumstances of her acquisition of both her first (Bulgarian) and second (German) languages and the unique patterns of both receptive and expressive language (in both the L1 and L2), in which she shows subtle dissociations in competence and performance consistent with an uneven cognitive profile of skills and abilities. We argue that this case provides support for theories of language learning and usage that require more general underlying cognitive mechanisms and skills. One such account, the Weak Central Coherence (WCC) hypothesis of autism, provides a plausible framework for the interpretation of the simultaneous co-occurrence of EV’s particular pattern of cognitive strengths and weaknesses. Furthermore, we show that specific features of the uneven cognitive profile of Asperger syndrome can help explain the observed language talent displayed by EV. Thus, rather than demonstrating a case where language learning takes place despite the presence of deficits, EV’s case illustrates how a pattern of strengths within this profile can specifically promote language learning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe an all-fibre, passive scheme for making extended range interferometric measurements based on the dual wavelength technique. The coherence tuned interferometer network is illuminated with a single superfluorescent fibre source at 1.55 µm and the two wavelengths are synthesised at the output by means of chirped fibre Bragg gratings. We demonstrate an unambiguous sensing range of 270 µm, with a dynamic range of 2.7 × 10 5.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate the repeatability and reproducibility of subfoveal choroidal thickness (CT) calculations performed manually using optical coherence tomography (OCT). Methods. The CT was imaged in vivo at each of two visits on 11 healthy volunteers (mean age, 35.72 ± 13.19 years) using the spectral domain OCT. CT was manually measured after applying ImageJ processing filters on 15 radial subfoveal scans. Each radial scan was spaced 12° from each other and contained 2500 A-scans. The coefficient of variability, coefficient of repeatability (CoR), coefficient of reproducibility, and intraclass correlation coefficient determined the reproducibility and repeatability of the calculation. Axial length (AL) and mean spherical equivalent refractive error were measured with the IOLMaster and an open view autorefractor to study their potential relationship with CT. Results. The within-visit and between-visit coefficient of variability, CoR, coefficient of reproducibility, and intraclass correlation coefficient were 0.80, 2.97% 2.44%, and 99%, respectively. The subfoveal CT correlated significantly with AL (R = -0.60, p = 0.05). Conclusions. The subfoveal CT could be measured manually in vivo using OCT and the readings obtained from the healthy subjects evaluated were repeatable and reproducible. It is proposed that OCT could be a useful instrument to perform in vivo assessment and monitoring of CT changes in retinal disease. The preliminary results suggest a negative correlation between subfoveal CT and AL in such a way that it decreases with increasing AL but not with refractive error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We assess the accuracy of the Visante anterior segment optical coherence tomographer (AS-OCT) and present improved formulas for measurement of surface curvature and axial separation. Measurements are made in physical model eyes. Accuracy is compared for measurements of corneal thickness (d1) and anterior chamber depth (d2) using-built-in AS-OCT software versus the improved scheme. The improved scheme enables measurements of lens thickness (d 3) and surface curvature, in the form of conic sections specified by vertex radii and conic constants. These parameters are converted to surface coordinates for error analysis. The built-in AS-OCT software typically overestimates (mean±standard deviation(SD)]d1 by +62±4 μm and d2 by +4±88μm. The improved scheme reduces d1 (-0.4±4 μm) and d2 (0±49 μm) errors while also reducing d3 errors from +218±90 (uncorrected) to +14±123 μm (corrected). Surface x coordinate errors gradually increase toward the periphery. Considering the central 6-mm zone of each surface, the x coordinate errors for anterior and posterior corneal surfaces reached +3±10 and 0±23 μm, respectively, with the improved scheme. Those of the anterior and posterior lens surfaces reached +2±22 and +11±71 μm, respectively. Our improved scheme reduced AS-OCT errors and could, therefore, enhance pre- and postoperative assessments of keratorefractive or cataract surgery, including measurement of accommodating intraocular lenses. © 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A new commercially available optical low coherence reflectometry device (Lenstar, Haag-Streit or Allegro Biograph, Wavelight) provides high-resolution non-contact measurements of ocular biometry. The study evaluates the validity and repeatability of these measurements compared with current clinical instrumentation. Method: Measurements were taken with the LenStar and IOLMaster on 112 patients aged 41–96 years listed for cataract surgery. A subgroup of 21 patients also had A-scan applanation ultrasonography (OcuScan) performed. Intersession repeatability of the LenStar measurements was assessed on 32 patients Results: LenStar measurements of white-to-white were similar to the IOLMaster (average difference 0.06 (SD 0.03) D; p?=?0.305); corneal curvature measurements were similar to the IOLMaster (average difference -0.04 (0.20) D; p?=?0.240); anterior chamber depth measurements were significantly longer than the IOLMaster (by 0.10 (0.40) mm) and ultrasound (by 0.32 (0.62) mm; p<0.001); crystalline lens thickness measurements were similar to ultrasound (difference 0.16 (0.83) mm, p?=?0.382); axial length measurements were significantly longer than the IOLMaster (by 0.01 (0.02) mm) but shorter than ultrasound (by 0.14 (0.15) mm; p<0.001). The LensStar was unable to take measurements due to dense media opacities in a similar number of patients to the IOLMaster (9–10%). The LenStar biometric measurements were found to be highly repeatable (variability =2% of average value). Conclusions: Although there were some statistical differences between ocular biometry measurements between the LenStar and current clinical instruments, they were not clinically significant. LenStar measurements were highly repeatable and the instrument easy to use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gestalt grouping rules imply a process or mechanism for grouping together local features of an object into a perceptual whole. Several psychophysical experiments have been interpreted as evidence for constrained interactions between nearby spatial filter elements and this has led to the hypothesis that element linking might be mediated by these interactions. A common tacit assumption is that these interactions result in response modulation which disturbs a local contrast code. We addressed this possibility by performing contrast discrimination experiments using two-dimensional arrays of multiple Gabor patches arranged either (i) vertically, (ii) in circles (coherent conditions), or (iii) randomly (incoherent condition), as well as for a single Gabor patch. In each condition, contrast increments were applied to either the entire test stimulus (experiment 1) or a single patch whose position was cued (experiment 2). In experiment 3, the texture stimuli were reduced to a single contour by displaying only the central vertical strip. Performance was better for the multiple-patch conditions than for the single-patch condition, but whether the multiple-patch stimulus was coherent or not had no systematic effect on the results in any of the experiments. We conclude that constrained local interactions do not interfere with a local contrast code for our suprathreshold stimuli, suggesting that, in general, this is not the way in which element linking is achieved. The possibility that interactions are involved in enhancing the detectability of contour elements at threshold remains unchallenged by our experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is becoming clear that the detection and integration of synaptic input and its conversion into an output signal in cortical neurons are strongly influenced by background synaptic activity or "noise." The majority of this noise results from the spontaneous release of synaptic transmitters, interacting with ligand-gated ion channels in the postsynaptic neuron [Berretta N, Jones RSG (1996); A comparison of spontaneous synaptic EPSCs in layer V and layer II neurones in the rat entorhinal cortex in vitro. J Neurophysiol 76:1089-1110; Jones RSG, Woodhall GL (2005) Background synaptic activity in rat entorhinal cortical neurons: differential control of transmitter release by presynaptic receptors. J Physiol 562:107-120; LoTurco JJ, Mody I, Kriegstein AR (1990) Differential activation of glutamate receptors by spontaneously released transmitter in slices of neocortex. Neurosci Lett 114:265-271; Otis TS, Staley KJ, Mody I (1991) Perpetual inhibitory activity in mammalian brain slices generated by spontaneous GABA release. Brain Res 545:142-150; Ropert N, Miles R, Korn H (1990) Characteristics of miniature inhibitory postsynaptic currents in CA1 pyramidal neurones of rat hippocampus. J Physiol 428:707-722; Salin PA, Prince DA (1996) Spontaneous GABAA receptor-mediated inhibitory currents in adult rat somatosensory cortex. J Neurophysiol 75:1573-1588; Staley KJ (1999) Quantal GABA release: noise or not? Nat Neurosci 2:494-495; Woodhall GL, Bailey SJ, Thompson SE, Evans DIP, Stacey AE, Jones RSG (2005) Fundamental differences in spontaneous synaptic inhibition between deep and superficial layers of the rat entorhinal cortex. Hippocampus 15:232-245]. The function of synaptic noise has been the subject of debate for some years, but there is increasing evidence that it modifies or controls neuronal excitability and, thus, the integrative properties of cortical neurons. In the present study we have investigated a novel approach [Rudolph M, Piwkowska Z, Badoual M, Bal T, Destexhe A (2004) A method to estimate synaptic conductances from membrane potential fluctuations. J Neurophysiol 91:2884-2896] to simultaneously quantify synaptic inhibitory and excitatory synaptic noise, together with postsynaptic excitability, in rat entorhinal cortical neurons in vitro. The results suggest that this is a viable and useful approach to the study of the function of synaptic noise in cortical networks. © 2007 IBRO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two-tone intermodulation tests were simulated for an amplitude modulated radio-on-fibre link including fibre dispersion, nonlinearity and loss. The third-order intercept results are presented for varying fibre lengths and optical transmission powers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is shown that regimes with dynamical chaos are inherent not only to nonlinear system but they can be generated by initially linear systems and the requirements for chaotic dynamics and characteristics need further elaboration. Three simplest physical models are considered as examples. In the first, dynamic chaos in the interaction of three linear oscillators is investigated. Analogous process is shown in the second model of electromagnetic wave scattering in a double periodical inhomogeneous medium occupying half-space. The third model is a linear parametric problem for the electromagnetic field in homogeneous dielectric medium which permittivity is modulated in time. © 2008 Springer Science+Business Media, LLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fathers in the United Kingdom (UK) usually attend the birth and immediate care of their baby. They also have an increasing presence during complicated and preterm childbirth, newborn resuscitation and early neonatal unit(NNU) care. However, there is limited evidence about the effect of these experiences on them. The aim of this study was to gain an understanding of the experiences of fathers encountering these situations. The study consisted of three phases and was undertaken in one National Health Service trust in the UK. Qualitative semi-structured interviews using a phenomenological approach were undertaken with 20 first-time fathers present at the delivery, resuscitation and/or admission of their baby to the NNU. Direct observations were made of 22 normal and complicated deliveries and initial newborn care and qualitative semi-structured interviews using the critical incident approach were undertaken with 37 health care professionals (HCPs). The study generated qualitative and quantitative data that were analysed accordingly. The findings show that most fathers were involved for at least some of the time and often spontaneously initiated their involvement. Their most important need was for information. They were usually more concerned about their partner, irrespective of the baby?s need for resuscitation and NNU care. To facilitate their involvement, fathers needed guidance and support from HCPs, particularly delivery suite midwives. Most HCPs recognised the needs of fathers and ways in which they could be helped to connect with their experience. However, these needs were not always met, usually because of inadequate staffing levels, a lack of resources or a mother-centred philosophy of care. The findings suggest the service often determines the extent to which fathers are involved. It is anticipated that these findings will inform HCP education and training and the development of both policy and health education thereby enhancing the quality of care provision for fathers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Astrocytes release gliotransmitters, notably glutamate, that can affect neuronal and synaptic activity. In particular, astrocytic glutamate release results in the generation of NMDA receptor (NMDA-R)-mediated slow inward currents (SICs) in neurons. However, factors underlying the emergence of SICs and their physiological roles are essentially unknown. Here we show that, in acute slices of rat somatosensory thalamus, stimulation of lemniscal or cortical afferents results in a sustained increase of SICs in thalamocortical (TC) neurons that outlasts the duration of the stimulus by 1 h. This long-term enhancement of astrocytic glutamate release is induced by group I metabotropic glutamate receptors and is dependent on astrocytic intracellular calcium. Neuronal SICs are mediated by extrasynaptic NR2B subunit-containing NMDA-Rs and are capable of eliciting bursts. These are distinct from T-type Ca2+ channel-dependent bursts of action potentials and are synchronized in neighboring TC neurons. These findings describe a previously unrecognized form of excitatory, nonsynaptic plasticity in the CNS that feeds forward to generate local neuronal firing long after stimulus termination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work described in this thesis is directed towards the reduction of tyre/road interface noise and embodies a study of the factors involved in its generation. These factors comprise: (a) materials and construction of tyres and road surfaces (b) the spectral distribution of the noise. The importance of this work has become greater with reduction in engine noise. A review of the literature shows what has been achieved so far, and stresses the importance of maintaining other desirable tyre properties such as adhesion in wet conditions. The work has involved an analysis of mechanical factors in tyre construction and the behaviour of road surfaces. Measurements on noise have been carried out under practical conditions and also on replica surfaces in the laboratory, and in addition tests of wet road adhesion have been carried out with a variety of road surfaces. Consideration has been given to the psychological effects of the spectral distribution of noise. A major part of the work under-taken has been the development of a computer program, the results of which have made it possible to design a tyre tread block pattern to give an optimum spectral distribution. Sample tyres built to this design have been subjected to noise measurements and these have been shown to agree closely with the theoretical prediction and other properties of this tyre have proved to be satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate the use of tilted fiber gratings to assist with the generation of infrared surface plasmons on a metal film coating the flat of a D-shaped fiber. The wavelength of the strong (>25 dB) resonance is tunable over similar to 1000 nm by adjusting the polarization state of the light and is highly sensitive to the refractive index of any aqueous medium surrounding the fiber (sensitivity= 3365 nm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe how an acousto-optic tunable filter can be used to both demultiplex the signals from multiple fibre Bragg grating sensors and simultaneously provide wide bandwidth signal demodulation in a system using interferometric wavelength shift detection. In an experimental demonstration, the approach provided a noise limited strain resolution of 24.9 n epsilon Hz(-1/ 2) at 15 Hz.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical coherence tomography (OCT) system to produce both longitudinal and transversal images of the in vivo human eye is presented. For the first time, OCT transversal images collected from the living eye at 50-µm depth steps show details unobtainable with the state-of-the-art scanning laser ophthalmoscope. Images of up to 3×3?mm are produced from the retina in less than a second. For images larger than 1.6×1.6?mm, a path modulation is introduced by the galvanometric scanning mirror and is used as an effective phase modulation method.