812 resultados para sorbent materials


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research explores the downstream perceptions of liquid carton board versus competing materials in packaging applications for juice. The methodology used is focus groups. The context is sustainability and functional performance, and related potential implications for the beverage industry value chain. The purpose is to get a deeper insight and understanding of functionality in relation to juice beverage packaging. The results confirm that there is no optimal packaging for every juice product, but a multitude, depending on the distribution channel, retail outlet, customer preferences, and context of consumption. There are some general packaging preferences, but the main deciding criteria for purchase seem to be the product characteristics in terms of quality, taste, brand, price and shelf life. For marketing reasons, packaging has to be adopted to the product and its positioning, liquid carton board packaging seem to have some functional advantages in distribution and is considered as sustainable and functional among many consumers. Major drawbacks seem to be shape limitations, lack of transparency, and lack of a “premium look”. To improve packaging performance and avoid sub-optimization, actors in the beverage industry value chain need to be integrated in development processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Problem/Opportunity: To define, identify, and guide design-based materials collections in academic settings and foster community among those with existing collections and/or those considering creating and supporting one. Contents and topics: What is a materials collection? Why have a materials collection? Acquisition strategies Organizational approaches Programming possibilities Symposium summary Resources

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Faculty from Rhode Island School of Design representing Interior Architecture, Industrial Design, and Textiles detail their thoughtful interactions with materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Designers respond to issues and synthesize ideas from throughout the day as voices from the field who directly encounter the need for recently graduated students to possess the ability to investigate and interrogate materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Educators representing interactions with materials speak to critical approaches, life-cycle concerns, critical thinking of composition/process/properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

São apresentados os aspectos teóricos, práticos e bibliográficos envolvidos no desenvolvimento da tese de doutorado intitulada Modificação estrutural de bentonitas nacionais: caracterização e estudos de adsorção. O trabalho consistiu no desenvolvimento de um material adsorvente a partir de bentonitas, do tipo montmorilonitas, modificadas estruturalmente com o objetivo de aumentar sua capacidade de adsorção de poluentes, orgânicos e inorgânicos. O estudo visa incrementar o valor agregado deste recurso mineral e insere-se na área de tratamento de efluentes líquidos usando adsorventes não tradicionais, eficientes e de baixo custo em substituição ao carvão ativado ou às resinas de troca iônica. Foram estudadas as propriedades físicas e químicas; distribuição de tamanho de partículas, área superficial, potenciais eletrocinéticos, capacidade de troca catiônica, composição mineralógica, morfologia superficial e espaçamento basal, bem como as propriedades adsorptivas dos argilominerais não tratados e modificados, não modificadas e pilarizadas respectivamente. Também são discutidos os mecanismos de adsorção envolvidos e o desenvolvimento de um reator contínuo (adsorção em flocos) e de separação sólido/líquido. As modificações estruturais dos argilominerais foram realizadas via homoionização com cloreto de cálcio e posterior intercalação com compostos orgânicos com ação quelante de metais. A FENAN, bentonita obtida pela intercalação com Orto Fenantrolina (OF), foi a que apresentou melhor viabilidade técnica em termos de adsorção, adsorção/dessorção, floculação e de acumulação de poluentes na forma floculada e não floculada. Adicionalmente os estudos de reversibilidade da intercalação revelaram a alta estabilidade da OF na FENAN, em soluções fortemente ácidas, onde aproximadamente 90% da OF permanece ligada à superfície da argila. A quantidade de OF adsorvida na forma de unidades micelares foi de 112 mg por grama de bentonita a pH 8,5 ± 0,5. A caracterização das bentonitas, via difração de Raios X, análise térmica, microscopia eletrônica de varredura e por microscopia de força atômica, revelou que as FENAN possuem um comportamento estrutural muito estável ao longo da seqüência de adsorção/dessorção e que após a adsorção de poluentes inorgânicos, o quelato metálico formado apresenta alta estabilidade dentro da estrutura da organobentonita. A capacidade de acumulação alcançada nas FENAN foi de 110 mg de Cu/g de bentonita, valor superior à de diversos materiais adsorventes alternativos propostos em outros trabalhos similares. Os estudos de acumulação das FENAN floculadas – FENANFLOC, indicaram que a presença de floculante, na quantidade utilizada, não afeta significativamente a capacidade de remoção das bentonitas modificadas. Este comportamento apresentado, permitiu o desenvolvimento do Reator Expandido de Flocos Adsorventes (REFA), cujas características e parâmetros operacionais são discutidos em detalhe. Finalmente, os resultados são discutidos em termos dos fenômenos interfaciais envolvidos e dos potenciais práticos deste novo adsorvente e da nova técnica de adsorção em flocos no REFA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ultra-fast and improved analytical methodology based on microextraction by packed sorbent (MEPS) combined with ultra-performance LC (UPLC) was developed and validated for determination of (E)-resveratrol in wines. Important factors affecting the performance of MEPS such as the type of sorbent material (C2, C8, C18, SIL, and M1), number of extraction cycles, and sample volume were studied. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (50–250mL) in one extraction cycle (extract–discard) and in a short time period (about 3 min for the entire sample preparation step). (E)-Resveratrol was eluted by 1 250mL of the mixture containing 95% methanol and 5% water, and the separation was carried out on a highstrength silica HSS T3 analytical column (100 mm 2.1 mm, 1.8mm particle size) using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and methanol (eluent B) in the gradient elution mode (10 min of total analysis). The method was fully validated in terms of linearity, detection (LOD) and quantification (LOQ) limits, extraction yield, accuracy, and inter/intra-day precision, using a Madeira wine sample (ET) spiked with (E)-resveratrol at concentration levels ranging from 5 to 60mg/mL. Validation experiments revealed very good recovery rate of 9575.8% RSD, good linearity with r2 values 40.999 within the established concentration range, excellent repeatability (0.52%), and reproducibility (1.67%) values (expressed as RSD), thus demonstrating the robustness and accuracy of the MEPSC8/UPLC-photodiode array (PDA) method. The LOD of the method was 0.21mg/mL, whereas the LOQ was 0.68mg/mL. The validated methodology was applied to 30 commercial wines (24 red wines and six white wines) from different grape varieties, vintages, and regions. On the basis of the analytical validation, the MEPSC8/UPLC-PDA methodology shows to be an improved, sensitive, and ultra-fast approach for determination of (E)-resveratrol in wines with high resolving power within 6 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach based on microextraction by packed sorbent (MEPS) and reversed-phase high-throughput ultra high pressure liquid chromatography (UHPLC) method that uses a gradient elution and diode array detection to quantitate three biologically active flavonols in wines, myricetin, quercetin, and kaempferol, is described. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (selectivity, linearity, sensitivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters such as the type of sorbent material (C2, C8, C18, SIL, and C8/SCX), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, on the MEPS performance. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250 μL) in five extraction cycle and in a short time period (about 5 min for the entire sample preparation step). Under optimized conditions, excellent linearity View the MathML source(Rvalues2>0.9963), limits of detection of 0.006 μg mL−1 (quercetin) to 0.013 μg mL−1 (myricetin) and precision within 0.5–3.1% were observed for the target flavonols. The average recoveries of myricetin, quercetin and kaempferol for real samples were 83.0–97.7% with relative standard deviation (RSD, %) lower than 1.6%. The results obtained showed that the most abundant flavonol in the analyzed samples was myricetin (5.8 ± 3.7 μg mL−1). Quercetin (0.97 ± 0.41 μg mL−1) and kaempferol (0.66 ± 0.24 μg mL−1) were found in a lower concentration. The optimized MEPSC8 method was compared with a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis HLB) were used as reference. MEPSC8 approach offers an attractive alternative for analysis of flavonols in wines, providing a number of advantages including highest extraction efficiency (from 85.9 ± 0.9% to 92.1 ± 0.5%) in the shortest extraction time with low solvent consumption, fast sample throughput, more environmentally friendly and easy to perform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel analytical approach, based on a miniaturized extraction technique, the microextraction by packed sorbent (MEPS), followed by ultrahigh pressure liquid chromatography (UHPLC) separation combined with a photodiode array (PDA) detection, has been developed and validated for the quantitative determination of sixteen biologically active phenolic constituents of wine. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (linearity, sensitivity, selectivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters on the MEPS performance such as the type of sorbent material (C2, C8, C18, SIL, and M1), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, were studied. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250 μL) in five extraction cycle and in a short time period (about 5 min for the entire sample preparation step). The wine bioactive phenolics were eluted by 250 μL of the mixture containing 95% methanol and 5% water, and the separation was carried out on a HSS T3 analytical column (100 mm × 2.1 mm, 1.8 μm particle size) using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and methanol (eluent B) in the gradient elution mode (10 min of total analysis). The method gave satisfactory results in terms of linearity with r2-values > 0.9986 within the established concentration range. The LOD varied from 85 ng mL−1 (ferulic acid) to 0.32 μg mL−1 ((+)-catechin), whereas the LOQ values from 0.028 μg mL−1 (ferulic acid) to 1.08 μg mL−1 ((+)-catechin). Typical recoveries ranged between 81.1 and 99.6% for red wines and between 77.1 and 99.3% for white wines, with relative standard deviations (RSD) no larger than 10%. The extraction yields of the MEPSC8/UHPLC–PDA methodology were found between 78.1 (syringic acid) and 99.6% (o-coumaric acid) for red wines and between 76.2 and 99.1% for white wines. The inter-day precision, expressed as the relative standard deviation (RSD%), varied between 0.2% (p-coumaric and o-coumaric acids) and 7.5% (gentisic acid) while the intra-day precision between 0.2% (o-coumaric and cinnamic acids) and 4.7% (gallic acid and (−)-epicatechin). On the basis of analytical validation, it is shown that the MEPSC8/UHPLC–PDA methodology proves to be an improved, reliable, and ultra-fast approach for wine bioactive phenolics analysis, because of its capability for determining simultaneously in a single chromatographic run several bioactive metabolites with high sensitivity, selectivity and resolving power within only 10 min. Preliminary studies have been carried out on 34 real whole wine samples, in order to assess the performance of the described procedure. The new approach offers decreased sample preparation and analysis time, and moreover is cheaper, more environmentally friendly and easier to perform as compared to traditional methodologies.