968 resultados para signal detection
Resumo:
Presented at Faculdade de Ciências e Tecnologias, Universidade de Lisboa, to obtain the Master Degree in Conservation and Restoration of Textiles
Resumo:
The intensification of agricultural productivity is an important challenge worldwide. However, environmental stressors can provide challenges to this intensification. The progressive occurrence of the cyanotoxins cylindrospermopsin (CYN) and microcystin-LR (MC-LR) as a potential consequence of eutrophication and climate change is of increasing concern in the agricultural sector because it has been reported that these cyanotoxins exert harmful effects in crop plants. A proteomic-based approach has been shown to be a suitable tool for the detection and identification of the primary responses of organisms exposed to cyanotoxins. The aim of this study was to compare the leaf-proteome profiles of lettuce plants exposed to environmentally relevant concentrations of CYN and a MC-LR/CYN mixture. Lettuce plants were exposed to 1, 10, and 100 lg/l CYN and a MC-LR/CYN mixture for five days. The proteins of lettuce leaves were separated by twodimensional electrophoresis (2-DE), and those that were differentially abundant were then identified by matrix-assisted laser desorption/ionization time of flight-mass spectrometry (MALDI-TOF/TOF MS). The biological functions of the proteins that were most represented in both experiments were photosynthesis and carbon metabolism and stress/defense response. Proteins involved in protein synthesis and signal transduction were also highly observed in the MC-LR/CYN experiment. Although distinct protein abundance patterns were observed in both experiments, the effects appear to be concentration-dependent, and the effects of the mixture were clearly stronger than those of CYN alone. The obtained results highlight the putative tolerance of lettuce to CYN at concentrations up to 100 lg/l. Furthermore, the combination of CYN with MC-LR at low concentrations (1 lg/l) stimulated a significant increase in the fresh weight (fr. wt) of lettuce leaves and at the proteomic level resulted in the increase in abundance of a high number of proteins. In contrast, many proteins exhibited a decrease in abundance or were absent in the gels of the simultaneous exposure to 10 and 100 lg/l MC-LR/CYN. In the latter, also a significant decrease in the fr. wt of lettuce leaves was obtained. These findings provide important insights into the molecular mechanisms of the lettuce response to CYN and MC-LR/CYN and may contribute to the identification of potential protein markers of exposure and proteins that may confer tolerance to CYN and MC-LR/CYN. Furthermore, because lettuce is an important crop worldwide, this study may improve our understanding of the potential impact of these cyanotoxins on its quality traits (e.g., presence of allergenic proteins).
Resumo:
For a period of 2 years, five follow-up measures of prevalence and incidence rates were estimated in a prospective study of S. mansoni infection in a group of schoolchildren who were living in a rural area of the Municipality of Itariri (São Paulo, Brazil), where schistosomiasis is transmitted by Biomphalaria tenagophila. Infection was determined by the examination of three Kato-Katz stool slides, and the parasitological findings were analyzed in comparison to serological data. In the five surveys, carried out at 6-month intervals (March-April and September-October), the prevalences were, respectively, 8.6, 6.8, 9.9, 5.8 and 17.2% by the Kato-Katz, and 56.5, 52.6, 60.8, 53.5 and 70.1% by the immunofluorescence test (IFT). Geometric mean egg counts were low: 57.8, 33.0, 35.6, 47.3 and 40.9 eggs per gram of feces, respectively. Of the total of 299 schoolchildren, who submitted five blood samples at 6-month intervals, one for each survey, 40% were IFT-positive throughout the study, and 22% were IFT-negative in all five surveys. Seroconversion from IFT negative to positive, indicating newly acquired S. mansoni infection, was observed more frequently in surveys carried out during March-April (after Summer holidays), than during September-October. Seasonal trends were not statistically significant for detection of S. mansoni eggs in stool. The results indicate that the use of IgM-IFT is superior to parasitological methods for detection of incidence of S. mansoni infection in areas with low worm burden.
Resumo:
An indirect ELISA for determination of post-vaccination rabies antibody was applied. Purified rabies virus was used as antigen to coat plates, and staphylococcal protein A linked with horseradish peroxidase was used for detecting IgG antibody in human sera. Sera from humans, vaccinated with cell-culture vaccine or suckling-mouse-brain vaccine, were examined. ELISA results were compared to those obtained from the virus neutralization test. The mean and standard deviation of OD were determined for 126 negative sera (pre-vaccination) and for 73 sera from vaccinated persons showing antibody titers lower than 0.5 IU/ml. Results were defined as ELISA -positive, -negative or -doubtful. Establishment of a doubtful region reduced the number of sera otherwise classified as positive (false-positive sera). In this way, the sensitivity, specificity and agreement values were respectively 87.5%, 92.4% and 88.5%. No significant differences were observed in these values when the group vaccinated with cell-culture vaccine and the group vaccinated with suckling-mouse-brain vaccine were compared. It was shown that much of the disagreement between the values obtained by neutralization test and ELISA occurred in sera obtained at the beginning of the immunization process, and was probably due to the presence of IgM in the serum samples, detected only by the former test. This ELISA method can be used as a screening test in rabies laboratories regardless of the kind of vaccine used for immunization.
Resumo:
A previously healthy seven-year-old boy was admitted to the intensive care unit because of toxaemia associated with varicella. He rapidly developed shock and multisystem organ failure associated with the appearance of a deep-seated soft tissue infection and, despite aggressive treatment, died on hospital day 4. An M-non-typable, spe A and spe B positive Group A Streptococcus was cultured from a deep soft tissue aspirate. The criteria for defining Streptococcal toxic shock-like syndrome were fulfilled. The authors discuss the clinical and pathophysiological aspects of this disease as well as some unusual clinical findings related to this case.
Resumo:
It is known that fecal examination to detect Giardia lamblia cysts or trophozoites produces a high percentage of false-negative results. A commercially available immunoenzymatic assay (ProSpecT Giardia Microplate Assay, Alexon, Inc., BIOBRÁS) to detect G. lamblia specific coproantigen was evaluated for the first time in Brazil. A total of 90 specimens were tested. Each specimen was first tested as unpreserved stool, and then it was preserved in 10% Formalin to be tested 2 months later. The assay was able to identify all the 30 positive patients (sensitivity = 100.0%) by visual or spectrophotometric examination in the unpreserved specimens and was negative in 57 of the 60 patients without G. lamblia (specificity = 95.0%). The assay identified 27 of the 30 positive patients (sensitivity = 90.0%) and was negative in 59 of the 60 negatives (specificity = 98.3%) in the preserved stools according to both readings. A marked difference was observed in the optical densities in both groups, preserved and unpreserved stools, when the G. lamblia-positive specimens were compared to the negative or positive for other intestinal parasites than G. lamblia. The assay seems a good alternative for giardiasis diagnosis, especially when the fecal examination was repeatedly negative and the patient presents giardiasislike symptoms.
Resumo:
We report the detection of specific IgA antibodies and the determination of IgG avidity in sequential serum samples from a patient exhibiting significant levels of Toxoplasma-specific IgM antibodies for seven years after the onset of the clinical symptoms of toxoplasmosis. IgM antibodies were detected by an indirect immunofluorescence test and by three commercial enzyme-linked immunosorbent assays (ELISA). Anti-T. gondii IgA was quantified by the a-capture ELISA technique using a commercial kit. As defined by the manufacturer of the IgA ELISA test used, most patients with acute toxoplasmosis have antibody levels > 40 arbitrary units per ml (AU/mL). At this cut-off level, the patient still had a positive ELISA result (45 AU/mL) in a serum sample taken one year after the beginning of clinical manifestations. The IgG avidity-ELISA test was performed with the Falcon assay screening test (F.A.S.T.®) - ELISA system. Avidity indices compatible with a recent Toxoplasma infection were found only in serum samples taken during the first 5 months after the onset of the clinical symptoms of toxoplasmosis. These results show that the interpretation of positive IgM results as indicative of recently acquired toxoplasmosis requires additional laboratory confirmation either by other tests or by the demonstration of a significant rise in the antibody titers in sequential serum samples.
Resumo:
Active infection by T. gondii was evaluated by immunoassay for soluble SAG-1 (p30), the major surface antigen from T. gondii, specific antibodies and immune complexes in human cerebrospinal fluid (CSF) samples. A total of 263 samples of CSF were collected from hospitalized patients presenting neurological disorders and analyzed for antibodies to HIV. Patients were divided into two groups: HIV positive (n = 96) or HIV negative (n =167). The results of the assays showed that 45% of all samples were positive for soluble SAG-1. Toxoplasma Ag/Ab immune complexes were detected in 19% of the CSF samples and 62% were positive for T. gondii- specific IgG. A combination of these assays in the presence of clinical findings consistent with active Toxoplasma infection may predict the presence of toxoplasmic encephalitis. Moreover, detection of soluble SAG-1 in the CSF of these individuals appears consistent with active infection.
Resumo:
Neurocysticercosis (NC), the presence of Taenia solium metacestodes in tissues, is the most frequent and severe parasitic infection of the central nervous system. We investigated the presence of total IgE by an automated chemiluminescence assay in 53 paired cerebrospinal fluid (CSF) and serum samples from patients with NC (P) and in 40 CSF samples from individuals with other neurological disorders as the control group (C). Total IgE concentration ranged from 1.2 to 6.6 IU/ml (mean = 1.4 IU/ml, standard deviation-sd = 1.1 IU/ml) in 28.3% of CSF samples from the P group, a value significantly higher than for the C group (£1.0 IU/ml). The serum samples from the P group showed concentrations ranging from 1.0 to 2330.0 IU/ml (mean = 224.1 IU/ml, sd = 452.1 IU/ml), which were higher than the normal value cited by the manufacturer (<100.0 IU/ml) in 32.1% of the samples. A significant difference was observed in CSF samples from the P and C groups (p = 0.005) and in serum samples from the P group compared to the normal value (p = 0.005), with sera showing more frequent abnormal results.
Resumo:
The possibility of detecting acute infection and immunity using body fluids that are easier to collect than blood, mainly in children, would facilitate the investigation and follow-up of outbreaks of hepatitis A (HAV). Our study was carried out to evaluate the detection of anti-HAV IgM, IgA and total antibodies in saliva using serum samples as reference. Forty three paired serum and saliva samples were analyzed. From this total, 24 samples were obtained from children and 1 from one adult during the course of acute hepatitis A; an additional 18 samples were obtained from health professionals from Adolfo Lutz Institute. The sensitivity to detect anti-HAV IgM was 100% (95%CI: 79.1 to 100.0%), employing saliva as clinical samples. In detecting anti-HAV IgA, the sensitivity was 80.8% (95%CI: 60.0 to 92.7%) and for the total antibodies was 82.1% (95%CI: 62.4 to 93.2%). The specificity was 100% for each. The rate of agreement was high comparing the results of serum and saliva samples for detecting HAV antibodies. We conclude that saliva is an acceptable alternative specimen for diagnosing acute hepatitis A infection, and for screening individuals to receive hepatitis A vaccine or immunoglobulin.
Resumo:
Esta dissertação apresenta o trabalho realizado no âmbito da unidade curricular de Tese/Dissertação (TEDI), do 2º ano, do Mestrado em Engenharia Eletrotécnica e de Computadores no ramo de Automação e Sistemas. O principal objetivo desta dissertação consiste no desenvolvimento de um sistema que permita efetuar a deteção de um determinado número de anomalias num sinal eletrocardiográfico. O coração é um dos órgãos mais importantes do corpo humano. É ele que recebe e bombeia o sangue pelo organismo. Isto é, recebe sangue pobre em oxigénio, encaminha-o para os pulmões onde será enriquecido em oxigénio. O sangue enriquecido em oxigénio é então encaminhado novamente para o coração que será enviado para todas as partes do corpo humano. O eletrocardiograma desempenha um papel fundamental de modo a diagnosticar eventuais anomalias no correto funcionamento do coração. Estas anomalias podem dever-se a diversos fatores como tabaco, colesterol, pressão sanguínea alta ou diabetes entre outros. As anomalias associadas ao ritmo cardíaco são denominadas de arritmias. As arritmias são fundamentalmente originadas pela alteração da frequência ou do ritmo cardíaco. Utilizando a lógica difusa, pretendeu-se desenvolver um sistema que fizesse a identificação de um determinado número de tipos de batimentos entre os quais: o bloqueio do ramo esquerdo (LBBB), bloqueio do ramo direito (RBBB), contração prematura ventricular (VPC) e contração prematura auricular (APC). Todos os desenvolvimentos efetuados, a nível de programação, são neste documento relatados de forma a constituírem um possível guia para a utilização deste tipo de sistemas. Mais ainda, descrevem-se nele toda a pesquisa efetuada e as alternativas de desenvolvimento selecionadas. O Sistema de Deteção de Arritmias (SDA) desenvolvido mostrou-se eficaz desde que o utilizador consiga identificar corretamente os parâmetros que lhe são pedidos. A interface gráfica desenvolvida permitiu também uma maior facilidade durante a análise do sinal eletrocardiográfico.
Resumo:
Dissertation presented to obtain the Ph.D degree in Biology by Universidade Nova de Lisboa, Instituto de Tecnologia Química e Biológica, Instituto Gulbenkian de Ciência.
Resumo:
O cancro é uma das principais causas de morte em todo o mundo. Entre as mulheres, o cancro da mama é o mais frequente. A deteção precoce do cancro é de extrema importância na medida em que pode aumentar as possibilidades de cura dos pacientes e contribuir para a diminuição da taxa de mortalidade desta doença. Um método que tem contribuído para a deteção precoce do cancro é a análise de biomarcadores. Biomarcadores associados ao cancro da mama, como o Recetor 2 do Fator de Crescimento Epidérmico Humano (HER2) e o Antigénio Carbohidratado 15-3 (CA 15-3), podem ser detetados através de dispositivos como os biossensores. Neste trabalho foram desenvolvidos dois imunossensores eletroquímicos para a análise de HER2 e CA 15-3. Para ambos os sensores foram utilizados, como transdutores, elétrodos serigrafados de carbono. A superfície destes transdutores foi nanoestruturada com nanopartículas de ouro. Foram realizados imunoensaios não-competitivos (do tipo sandwich) em ambos os imunossensores, cuja estratégia consistiu na (i) imobilização do respetivo anticorpo de captura na superfície nanoestruturada dos elétrodos, (ii) bloqueio da superfície com caseína, (iii) incubação com uma mistura do analito (HER2 ou CA 15-3) e o respetivo anticorpo de deteção biotinilado, (iv) adição de estreptavidina conjugada com fosfatase alcalina (S-AP; a AP foi utilizada como marcador enzimático), (v) adição de uma mistura do substrato enzimático (3-indoxil fosfato) e nitrato de prata, e (vi) deteção do sinal analítico através da redissolução anódica, por voltametria de varrimento linear, da prata depositada enzimaticamente. Com as condições experimentais otimizadas, foi estabelecida a curva de calibração para a análise de HER2 em soro, entre 15 e 100 ng/mL, obtendo-se um limite de deteção de 4,4 ng/mL. Para o CA 15-3 a curva de calibração (em solução aquosa) foi estabelecida entre 15 e 250 U/mL, obtendo-se um limite de deteção de 37,5 U/mL. Tendo em conta o valor limite (cutoff value) estabelecido para o HER2 (15 ng/mL) pode-se comprovar a possível utilidade do imunossensor desenvolvido para o diagnóstico precoce e descentralizado do cancro da mama. No caso do CA 15-3 serão necessários estudos adicionais para se poder avaliar a utilidade do imunossensor para o diagnóstico do cancro da mama.