802 resultados para screen-printed gold electrode
Resumo:
A cathodically pretreated boron-doped diamond electrode was used for the simultaneous anodic determination of ascorbic acid (AA) and caffeine (CAF) by differential pulse voltammetry Linear calibration curves (r = 0 999) were obtained from 1 9 x 10(-5) to 2 I x 10(-4) mol L(-1) for AA and from 9 7 x 10(-6) to 1 1 x 10-4 mol L(-1) for CAF. with detection limits of 19 wool L(-1) and 7 0 mu nol L(-1). respectively This method was successfully applied for the determination of AA and CAF in pharmaceutical formulations. with results equal to those obtained using a HPLC reference method
Resumo:
A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential Pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials Of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 x 10(-7) mol L(-1) to 8.3 x 10(-7) mol L(-1) for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 x 10(-7) mol L-1 and 3.5 x 10(-8) mol L(-1), respectively. The proposed method Was Successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level). (C) 2008 Elsevier BY. All rights reserved.
Resumo:
Nat Gold graduated from the Sheet Metal program at the New York Trade School in 1942. He is represented here in the sheet metal shop he owns. Notice the blueprints for the White Plains Senior High School hanging on the wall behind him. Original caption reads, "Shop Owner, Brook Sheet Metal Inc. Nat Gold - Sheet Metal 1942, represents one of many Sheet Metal graduates who became owners of their own business." Black and white photograph.
Resumo:
This degree project illustrates newsprint and waterless offset. A new news press was introduced at Drupa-00, Cortina from KBA, which is the first news press dedicated the waterless technique. With actual statistics from the company in question an investigation was made whether their production fits this press. It came out in the investigation that the production of the company, from statistics, fits this press very good. A table was made where different timeschedules were accounted for the new press, with semi- and full automatic plate changing for present and to be added papers. The waterless technology is compared to conventional offset with the difference that the plate is based on a sort of laminatetechnology. Like conventional plates this plate has a base made of aluminium. Lightsensitive photopolymer isunited as a layer or coat on top of the aluminium and a 2µm thin oleophobic siliconlayer is applied on top of the photopolymer. Considering the print, the waterless method has a higher qualitygrade than conventional offset. No water is emulsifiedin the ink, and therefore the printed dot gets a higher density. The loss of dampening solution and higher tack of the ink gives sharper dots. This makes the colourspace bigger why a greater range of colours can be printed. The loss of dampening solution gives a more stable dotgain, which contributes to that a higher screen can be used. The disadvantage is that the plate can't do as many rotations as the conventional plate. A waterless plate makes around 100 000-500 000 rotations before it needs to be removed owing to type- and manufacturer of the plate. The plate is also slightly more sensitive and expensive than conventional plates, around 1,4 - 1,7 × aluminium printing plates. A waterless system can be installed in a conventional printing press by degrees and when large editions are being printed a cooler needs to be installed in the oscillationrollers of the press, since an increase in temperature can make the oleophobic parts of the plate oleophilic. The Cortina is however equipped with a temperature controlsystem at the beginning. To avoid picking, caused by the tacky ink, a blanket with a high “quick release” should be used.
Resumo:
This degree theme work aims to evaluate the present ICC-profile and printing ink of Dalarnas Tidningar AB. The companyhas changed printing ink quality and wants to evaluate how the present ICC-profile work with the new printingink. Four different ICC-profiles were included in the comparison.One test printing was accomplished with two different separations. Two new ICC-profile was created, as a comparingmaterial. An densitometer was used to measure the technical parameters of the printing. IT8-charts and RGB-chartswas measured with spectrophotometer. La*b*-values, CMYK-values, graybalance curves, color deflections and colorgamuts was compared on screen and on the printed material.Materials from an earlier testprinting and evalution, made by Stora Enso Kvarnsveden AB 2003, was used to evaluatethe function of Dalarnas Tidningar AB´s ICC-profile with the present printing ink quality. The IT8-chart from todaystestprinting was oppened in a program for textediting to have access to La*b*- and CMYK values. The values from theearlier testprinting was supplied from Stora Enso Kvarnsveden AB.The result of this work shows that the ICC-profile from the company, compared with de other profiles, reproduce darkershadow regions which can make loss of details. An higher saturation is recieved in the red and yellow area while thegreen and blue area lose its intensity. The profile gave images which are some contrastless and with a flat reproduction.Today printing ink quality gives more saturation and intensity in the yellow and blue area compared with former printingink. The dark tone reproduces with decreased luminance, however.
Resumo:
The aim of this study was to investigate if a telemetry test battery can be used to measure effects of Parkinson’s disease (PD) treatment intervention and disease progression in patients with fluctuations. Sixty-five patients diagnosed with advanced PD were recruited in an open longitudinal 36-month study; 35 treated with levodopa-carbidopa intestinal gel (LCIG) and 30 were candidates for switching from oral PD treatment to LCIG. They utilized a test battery, consisting of self-assessments of symptoms and fine motor tests (tapping and spiral drawings), four times per day in their homes during week-long test periods. The repeated measurements were summarized into an overall test score (OTS) to represent the global condition of the patient during a test period. Clinical assessments included ratings on Unified PD Rating Scale (UPDRS) and 39-item PD Questionnaire (PDQ-39) scales. In LCIG-naïve patients, mean OTS compared to baseline was significantly improved from the first test period on LCIG treatment until month 24. In LCIG-non-naïve patients, there were no significant changes in mean OTS until month 36. The OTS correlated adequately with total UPDRS (rho = 0.59) and total PDQ-39 (0.59). Responsiveness measured as effect size was 0.696 and 0.536 for OTS and UPDRS respectively. The trends of the test scores were similar to the trends of clinical rating scores but dropout rate was high. Correlations between OTS and clinical rating scales were adequate indicating that the test battery contains important elements of the information of well-established scales. The responsiveness and reproducibility were better for OTS than for total UPDRS.
Resumo:
Evelyn Mae Levine was born April 11, 1907 and died on February 6, 1957. She was one of the children born to William and Sarah Levine. The scrapbook includes photographs, family memories, negative copies of grade sheets from Coburn Classical Instituteand Emerson College.