832 resultados para rump fat thickness


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This present study aimed at evaluating the effect of the addition of an emulsifier to diets containing soybean oil, poultry fat or their blend, on the performance, carcass traits, serum lipid levels, pancreatic lipase concentration and nutrient digestibility of broilers. A randomized block design was applied using a 3 x 2 factorial arrangement, with three fat sources (soybean oil, poultry fat, and a blend of 50% soybean oil and 50% poultry fat) and the addition or not of an emulsifier. In experiment I, broiler performance, carcass traits, serum cholesterol, HDL, and triglyceride levels, and pancreatic lipase activity in 42-day-old broilers were evaluated. In experiment II, dry matter (DM), ether extract (EE), crude protein (CP) and crude fiber (CF) coefficients of digestibility were analyzed. Broilers fed the diet containing soybean oil and emulsifier presented higher body weight, weight gain and better feed conversion ratio. When birds were fed poultry fat and the fat blend (soybean oil and poultry fat) and the emulsifier was added to the diets, pancreatic lipase concentration increased. It was concluded that the use of soybean oil, poultry fat and their blend does no in the diet does not influence the performance, carcass traits, or serum cholesterol, HDL and triglyceride levels of 42-day-old broilers. The addition of emulsifiers to diets containing poultry fat improves ether extract digestibility and increases the production and secretion of pancreatic lipase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivando estudar o efeito da somatotropina bovina recombinante (rbST) sobre o desempenho, as características de carcaça e as concentrações plasmáticas de IGF-I e hormônios tireoideanos, 36 bezerros mestiços ½ Angus-Nelore com idade de 63 ± 17 dias e pesando 76,8 ± 14,7 kg, criados em pastagens de Brachiaria decumbens e suplementados em creep feeding, foram submetidos a dois tratamentos até a desmama (217 dias): I) 18 bezerros receberam 1,4 mg/kg de rbST (Boostin®) a cada 14 dias; II) 18 bezerros controle receberam solução salina. As pesagens e colheitas de sangue foram realizadas a cada 28 dias e, à desmama, foram abatidos cinco animais de cada tratamento, para avaliação das características de carcaça. Os animais tratados apresentaram maior ganho de peso médio diário e peso vivo final, maiores concentrações plasmáticas de IGF-I e T4 que os bezerros controle. Os parâmetros peso de carcaça quente, rendimento de carcaça, pesos de traseiro e dianteiro, gordura peri-renal, peso de fígado, área de olho de lombo, espessura de gordura subcutânea, pesos dos músculos do quarto do traseiro e concentração plasmática de T3 não diferiram entre os tratamentos. A utilização de rbST proporcionou aumento de 7,9% no ganho de peso vivo e alterou o perfil hormonal de bezerros suplementados em creep feeding durante a fase de cria, não refletindo, entretanto, em maior peso ou rendimento de carcaça.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O trabalho foi conduzido com o objetivo de avaliar o efeito de diferentes linhagens (conformação versus convencionais) sobre o desempenho, rendimento de carcaça e partes, medidas físicas (espessura, largura e comprimento do filé do peito) e qualidade da carne do peito (perda de peso por cozimento, maciez e pH) em frangos de corte com 35, 42 e 49 dias. Foram utilizados 2400 pintos de um dia, distribuídos em um delineamento inteiramente casualizado em fatorial 5x2, com cinco linhagens (conformação A, B e C ; e convencionais D e E) e dois sexos, com quatro repetições de 60 aves cada. O crescimento das aves foi diferente, havendo linhagens com maior crescimento tanto entre as de conformação quanto entre as convencionais. As linhagens apresentaram desempenho diferenciado para ganho de peso, consumo de ração e conversão alimentar. Os animais de algumas linhagens de conformação apresentaram desempenho superior às convencionais, mas o oposto também foi verificado. O rendimento de carcaça diferiu aos 35 dias, com as linhagens de conformação apresentando os maiores rendimentos. O rendimento de pernas e carne de pernas foi semelhante ou melhor nas linhagens convencionais e os maiores rendimentos de peito e carne de peito ocorreram nas linhagens de conformação. A gordura abdominal diferiu aos 42 dias somente entre as linhagens de conformação. A espessura, largura e comprimento dos filés do peito também foram diferentes, com as linhagens de conformação apresentando valores semelhantes entre si e superiores aos das linhagens convencionais. Não houve diferenças nos parâmetros de qualidade da carne. O sexo das aves teve influência tanto no desempenho quanto no rendimento de carcaça e partes, porém não afetou a qualidade da carne do peito.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Implant overdenture prostheses are prone to acrylic resin fracture because of space limitations around the implant overdenture components.Purpose. The purpose of this study was to evaluate the influence of E-glass fibers and acrylic resin thickness in resisting acrylic resin fracture around a simulated overdenture abutment.Material and methods. A model was developed to simulate the clinical situation of an implant overdenture abutment with varying acrylic resin thickness (1.5 or 3.0 mm) with or without E-glass fiber reinforcement. Forty-eight specimens with an underlying simulated abutment were divided into 4 groups (n=12): 1.5 mm acrylic resin without E-glass fibers identified as thin with no E-glass fiber mesh (TN-N); 1.5 mm acrylic resin with E-glass fibers identified as thin with E-glass fiber mesh (TN-F); 3.0 mm acrylic resin without E-glass fibers identified as thick without E-glass fiber mesh (TK-N); and 3.0 mm acrylic resin with E-glass fibers identified as thick with E-glass fiber mesh (TK-F). All specimens were submitted to a 3-point bending test and fracture loads (N) were analyzed with a 2-way ANOVA and Tukey's post hoc test (alpha=.05).Results. The results revealed significant differences in fracture load among the 4 groups, with significant effects from both thickness (P<.001) and inclusion of the mesh (P<.001). Results demonstrated no interaction between mesh and thickness (P=.690). The TN-N: 39 +/- 5 N; TN-F: 50 +/- 6.9 N; TK-N: 162 +/- 13 N; and TK-F: 193 +/- 21 N groups were all statistically different (P<.001).Conclusions. The fracture load of a processed, acrylic resin implant-supported overdenture can be significantly increased by the addition of E-glass fibers even when using thin acrylic resin sections. on a relative basis, the increase in fracture load was similar when adding E-glass fibers or increasing acrylic resin thickness. (J Prosthet Dent 2011;106:373-377)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extent of separation between the maxillary and mandibular teeth in the fabrication of interocclusal splints designed to achieve efficiency and muscle relaxation is controversial and undefined in the literature. Based on this premise, the aim of this study was to evaluate the effect of interocclusal splint thicknesses of 3 and 6 millimeters on the electrical activity of the anterior temporal and masseter muscles during rest and dental clenching. Twenty asymptomatic individuals (10 males and 10 females) were selected using the Research Diagnostic Criteria (RDC). Electromyography (EMG) was performed both with and without the 3- and 6-mm splints using the Bio EMG software package, which recorded values given in microvolts (mu V). The results, which were assessed using analysis of variance (ANOVA) to a 5% significance level (p < 0.05), showed increased electrical activity of the masticatory muscles during dental clenching compared with at rest, with greater activity in the masseter muscle. The electrical activity did not differ according to the thickness of the splints or between males and females. We can conclude that both splint thicknesses are effective in treating muscle hyperactivity given their similar clinical behavior for asymptomatic individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: the purpose of this study is to employ optical microscopy to measure the thickness of the hybrid layer and the penetration (tags) of an aggressive self-etching adhesive system into sound dentin.Methods: occtusat cavities were prepared in 40 extracted human posterior teeth. The prepared teeth were randomly assigned to four experimental groups with 10 specimens each. The self-etching adhesive system Adper Prompt L-Pop was applied to the dentin surface as follows: Group 1: cavosurface enamel was etched for 60 s and dentin for 20 s with 35% phosphoric acid get, immediately followed by application of the self -etching adhesive with a brush to the entire cavity for 15 s; Groups 2, 3, and 4: no pre-etching was performed, and the self -etching adhesive was applied to both enamel and dentin for 15, 30 and 45 s, respectively. After curing, the cavities were fitted with composite resin Fittek Z250. Afterwards, the teeth were decalcified and the restorations were carefully removed for later embedding in paraffin. The specimens were serially sectioned at 6 mu m of thickness and sequentially mounted in glass slides. These sections were stained with Brown and Brenn staining for posterior analysis and measurement of the hybrid layer and resin tags on a tight microscope with a micrometric ocular 40/075. The results were submitted to analysis of variance at the 5% level.Results: whenever there was significance, the Tukey test was applied at the 5% level. The specimens receiving application of acid etching before the selfetching. adhesive displayed a larger thickness of the hybrid layer; on the other hand, specimens receiving only application of the self -etching adhesive on dentin for 15, 30 and 45 s exhibited similar thickness of the hybrid layer. As regards the resin tags, no statistically significant differences could be found between the study groups.Conclusions: it could be concluded that the increase in the time of application of the self-etching adhesive Adper Prompt L-Pop did not significantly influence the formation and thickness of hybrid layer, as well as its penetration into the sound dentin surface. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador: