1000 resultados para nonpertubative method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the method development for the simultaneous determination of methylmercury MeHgþ) and inorganic mercury (iHg) species in seafood samples. The study focused on the extraction and quantification of MeHgþ (the most toxic species) by liquid chromatography coupled to on-line UV irradiation and cold vapour atomic fluorescence spectroscopy (LC-UV-CV-AFS), using HCl 4 mol/L as the extractant agent. Accuracy of the method has been verified by analysing three certified reference materials and different spiked samples. The values found for total Hg and MeHgþ for the CRMs did not differ significantly from certified values at a 95% confidence level, and recoveries between 85% and 97% for MeHgþ, based on spikes, were achieved. The detection limits (LODs) obtained were 0.001 mg Hg/kg for total mercury, 0.0003 mg Hg/kg for MeHgþ and 0.0004 mg Hg/kg for iHg. The quantification limits (LOQs) established were 0.003 mg Hg/kg for total mercury, 0.0010 mg Hg/kg for MeHgþ and 0.0012 mg Hg/kg for iHg. Precision for each mercury species was established, being 12% in terms of RSD in all cases. Finally, the developed method was applied to 24 seafood samples from different origins and total mercury contents. The concentrations for Total Hg, MeHg and iHg ranged from 0.07 to 2.33, 0.003-2.23 and 0.006-0.085 mg Hg/kg, respectively. The established analytical method allows to obtain results for mercury speciation in less than 1 one hour including both, sample pretreatment and measuring step.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following their detection and seizure by police and border guard authorities, false identity and travel documents are usually scanned, producing digital images. This research investigates the potential of these images to classify false identity documents, highlight links between documents produced by a same modus operandi or same source, and thus support forensic intelligence efforts. Inspired by previous research work about digital images of Ecstasy tablets, a systematic and complete method has been developed to acquire, collect, process and compare images of false identity documents. This first part of the article highlights the critical steps of the method and the development of a prototype that processes regions of interest extracted from images. Acquisition conditions have been fine-tuned in order to optimise reproducibility and comparability of images. Different filters and comparison metrics have been evaluated and the performance of the method has been assessed using two calibration and validation sets of documents, made up of 101 Italian driving licenses and 96 Portuguese passports seized in Switzerland, among which some were known to come from common sources. Results indicate that the use of Hue and Edge filters or their combination to extract profiles from images, and then the comparison of profiles with a Canberra distance-based metric provides the most accurate classification of documents. The method appears also to be quick, efficient and inexpensive. It can be easily operated from remote locations and shared amongst different organisations, which makes it very convenient for future operational applications. The method could serve as a first fast triage method that may help target more resource-intensive profiling methods (based on a visual, physical or chemical examination of documents for instance). Its contribution to forensic intelligence and its application to several sets of false identity documents seized by police and border guards will be developed in a forthcoming article (part II).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study shows the possibility offered by modern ultra-high performance supercritical fluid chromatography combined with tandem mass spectrometry in doping control analysis. A high throughput screening method was developed for 100 substances belonging to the challenging classes of anabolic agents, hormones and metabolic modulators, synthetic cannabinoids and glucocorticoids, which should be detected at low concentrations in urine. To selectively extract these doping agents from urine, a supported liquid extraction procedure was implemented in a 48-well plate format. At the tested concentration levels ranging from 0.5 to 5 ng/mL, the recoveries were better than 70% for 48-68% of the compounds and higher than 50% for 83-87% of the tested substances. Due to the numerous interferences related to isomers of steroids and ions produced by the loss of water in the electrospray source, the choice of SFC separation conditions was very challenging. After careful optimization, a Diol stationary phase was employed. The total analysis time for the screening assay was only 8 min, and interferences as well as susceptibility to matrix effect (ME) were minimized. With the developed method, about 70% of the compounds had relative ME within the range ±20%, at a concentration of 1 and 5 ng/mL. Finally, limits of detection achieved with the above-described strategy including 5-fold preconcentration were below 0.1 ng/mL for the majority of the tested compounds. Therefore, LODs were systematically better than the minimum required performance levels established by the World anti-doping agency, except for very few metabolites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and Methods Two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results In patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion The comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La dermatite irritative est décrite comme une réaction réversible, non immunologique caractérisée par des lésions d'aspect très variable, allant de la simple rougeur jusqu'à la formation de bulles voire d'une nécrose, accompagnée de prurit ou d'une sensation de brûlure suite à I' application d'une substance chimique. Le teste de prédiction d'irritation cutanée est traditionnellement depuis les années 1940 le Test de Draize. Ce test consiste en l'application d'une substance chimique sur une peau rasée de lapin pendant 4h et de regarder à 24h si des signes cliniques d'irritations sont présents. Cette méthode critiquable autant d'un point de vue éthique que qualitative reste actuellement le teste le plus utilisé. Depuis le début des années 2000 de nouvelles méthodes in vitro se sont développées tel que le model d'épiderme humain recombiné (RHE). Il s agit d'une multicouche de kératinocyte bien différencié obtenu depuis une culture de don d'ovocyte. Cependant cette méthode en plus d'être très couteuse n'obtient au mieux que 76% de résultat similaire comparé au test in vivo humain. Il existe donc la nécessité de développer une nouvelle méthode in vitro qui simulerait encore mieux la réalité anatomique et physiologique retrouvée in vivo. Notre objectif a été de développer cette nouvelle méthode in vitro. Pour cela nous avons travaillé avec de la peau humaine directement prélevée après une abdominoplastie. Celle ci après préparation avec un dermatome, un couteau dont la lame est réglable pour découper l'épaisseur souhaitée de peau, est montée dans un système de diffusion cellulaire. La couche cornée est alors exposée de manière optimale à 1 ml de la substance chimique testée pendant 4h. L'échantillon de peau est alors fixé dans du formaldéhyde pour permettre la préparation de lames standards d'hématoxyline et éosine. L'irritation est alors investiguée selon des critères histopathologiques de spongioses, de nécroses et de vacuolisations cellulaires. Les résultats de ce.tte première batterie de testes sont plus que prometteurs. En effet, comparé au résultat in vivo, nous obtenons 100% de concordance pour les 4 même substances testes irritantes ou non irritantes, ce qui est supérieur au model d épiderme humain recombiné (76%). De plus le coefficient de variation entre les 3 différentes séries est inférieur à 0.1 ce qui montre une bonne reproductibilité dans un même laboratoire. Dans le futur cette méthode va devoir être testée avec un plus grand nombre de substances chimiques et sa reproductibilité évaluée dans différents laboratoires. Mais cette première evaluation, très encourageante, ouvre des pistes précieuses pour l'avenir des tests irritatifs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Body percussion using to the BAPNE method is a means of cognitive stimulation with multiple applications. The aim of this research is to assess their full potential as a source of therapy. The methodology used is theoretical in nature and makes use of a wide bibliography to find evidence for its therapeutic effect. In essence, body percussion can be seen to lead to improvements in three areas. the Physical, as it stimulates awareness of the body, control of movement and muscular strength, coordination and balance; the Mental, as it improves concentration, memory and perception; and finally Socio-affective, as it helps to build egalitarian relationships and leads to a decrease in anxiety in social interactions. This means of therapy has several different uses and it is targeted at different groups. In the present investigation we categorise them into five main groups: individuals with neurodegenerative diseases like Alzheimer's or Parkinson's disease; individuals with learning disorders such as dyslexia or ADHD; patients affected by diseases of the spinal cord, cranial neuropathies and trauma (Neurorehabilitation); and for the treatment of addictive behavior (addiction); and depressive disorders or anxiety disorders.After thorough analysis, we have found scientific evidence that the therapeutic body percussion using the BAPNE method improves the quality of life of patients and it is an important factor in stabilizing the development of different diseases.In addition, evidence involving certain biological indicators (in control and experimental groups, and through a pre-test and post-test) show its effect on levels of stress and anxiety (reduction of cortisol), as well as improvement of social relations as a result of working as a group (increased levels of oxytocin), and improvements seen in self-esteem and in a variety of personal aspects through the Aspects of Identity questionnaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at comparing the efficiency of various sampling materials for the collection and subsequent analysis of organic gunshot residues (OGSR). To the best of our knowledge, it is the first time that sampling devices were investigated in detail for further quantitation of OGSR by LC-MS. Seven sampling materials, namely two "swab"-type and five "stub"-type collection materials, were tested. The investigation started with the development of a simple and robust LC-MS method able to separate and quantify molecules typically found in gunpowders, such as diphenylamine or ethylcentralite. The evaluation of sampling materials was then systematically carried out by first analysing blank extracts of the materials to check for potential interferences and determining matrix effects. Based on these results, the best four materials, namely cotton buds, polyester swabs, a tape from 3M and PTFE were compared in terms of collection efficiency during shooting experiments using a set of 9 mm Luger ammunition. It was found that the tape was capable of recovering the highest amounts of OGSR. As tape-lifting is the technique currently used in routine for inorganic GSR, OGSR analysis might be implemented without modifying IGSR sampling and analysis procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most suitable method for estimation of size diversity is investigated. Size diversity is computed on the basis of the Shannon diversity expression adapted for continuous variables, such as size. It takes the form of an integral involving the probability density function (pdf) of the size of the individuals. Different approaches for the estimation of pdf are compared: parametric methods, assuming that data come from a determinate family of pdfs, and nonparametric methods, where pdf is estimated using some kind of local evaluation. Exponential, generalized Pareto, normal, and log-normal distributions have been used to generate simulated samples using estimated parameters from real samples. Nonparametric methods include discrete computation of data histograms based on size intervals and continuous kernel estimation of pdf. Kernel approach gives accurate estimation of size diversity, whilst parametric methods are only useful when the reference distribution have similar shape to the real one. Special attention is given for data standardization. The division of data by the sample geometric mean is proposedas the most suitable standardization method, which shows additional advantages: the same size diversity value is obtained when using original size or log-transformed data, and size measurements with different dimensionality (longitudes, areas, volumes or biomasses) may be immediately compared with the simple addition of ln k where kis the dimensionality (1, 2, or 3, respectively). Thus, the kernel estimation, after data standardization by division of sample geometric mean, arises as the most reliable and generalizable method of size diversity evaluation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A BASIC computer program (REMOVAL) was developed to compute in a VAXNMS environment all the calculations of the removal method for population size estimation (catch-effort method for closed populations with constant sampling effort). The program follows the maximum likelihood methodology,checks the failure conditions, applies the appropriate formula, and displays the estimates of population size and catchability, with their standard deviations and coefficients of variation, and two goodness-of-fit statistics with their significance levels. Data of removal experiments for the cyprinodontid fish Aphanius iberus in the Alt Emporda wetlands are used to exemplify the use of the program

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Needle trap devices (NTDs) are a relatively new and promising tool for headspace (HS) analysis. In this study, a dynamic HS sampling procedure is evaluated for the determination of volatile organic compounds (VOCs) in whole blood samples. A full factorial design was used to evaluate the influence of the number of cycles and incubation time and it is demonstrated that the controlling factor in the process is the number of cycles. A mathematical model can be used to determine the most appropriate number of cycles required to adsorb a prefixed amount of VOCs present in the HS phase whenever quantitative adsorption is reached in each cycle. Matrix effect is of great importance when complex biological samples, such as blood, are analyzed. The evaluation of the salting out effect showed a significant improvement in the volatilization of VOCs to the HS in this type of matrices. Moreover, a 1:4 (blood:water) dilution is required to obtain quantitative recoveries of the target analytes when external calibration is used. The method developed gives detection limits in the 0.020–0.080 μg L−1 range (0.1–0.4 μg L−1 range for undiluted blood samples) with appropriate repeatability values (RSD < 15% at high level and <23% at LOQ level). Figure of merits of the method can be improved by using a smaller phase ratio (i.e., an increase in the blood volume and a decrease in the HS volume), which lead to lower detection limits, better repeatability values and greater sensibility. Twenty-eight blood samples have been evaluated with the proposed method and the results agree with those indicated in other studies. Benzene was the only target compound that gave significant differences between blood levels detected in volunteer non-smokers and smokers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research on language equations has been active during last decades. Compared to the equations on words the equations on languages are much more difficult to solve. Even very simple equations that are easy to solve for words can be very hard for languages. In this thesis we study two of such equations, namely commutation and conjugacy equations. We study these equations on some limited special cases and compare some of these results to the solutions of corresponding equations on words. For both equations we study the maximal solutions, the centralizer and the conjugator. We present a fixed point method that we can use to search these maximal solutions and analyze the reasons why this method is not successful for all languages. We give also several examples to illustrate the behaviour of this method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The counteranion exchange of quaternary 1,2,3-triazolium salts was examined using a simple method that permitted halide ions to be swap for a variety of anions using an anion exchange resin (A¯ form). The method was applied to 1,2,3-triazolium-based ionic liquids and the iodideto- anion exchange proceeded in excellent to quantitative yields, concomitantly removing halide impurities. Additionally, an anion exchange resin (N3¯ form) was used to obtain the benzyl azide from benzyl halide under mild reaction. Likewise, following a similar protocol, bis(azidomethyl)arenes were also synthesized in excellent yields. The results of a proton NMR spectroscopic study of simple azolium-based ion pairs are discussed, with attention focused on the significance of the charged-assisted (CH)+···anion hydrogen bonds of simple azolium systems such as 1-butyl-3-methylimidazolium and 1-benzyl-3-methyl-1,2,3-triazolium salts.