986 resultados para microwave-assisted extraction
Resumo:
Purpose:To evaluate the histological features of cellular retinal fragments on the internal limiting membrane (ILM) removed during epiretinal membrane peeling surgery with and without the aid of ICG diluted in 5% glucose Methods:ILM specimens removed from 88 eyes undergoing vitrectomy and membrane peeling surgery for idiopathic epiretinal membrane between 1995 and 2003 were reviewed retrospectively. Surgery was performed in all cases by the same surgeon using the same technique. ICG was diluted with 5% glucose. Histological analysis focused on the presence and characteristics of retinal structures on the retinal surface of the ILM. Statistical analysis compared the results between group I (conventional surgery without ICG) and group II (ICG-assisted peeling) Results:Seventy-one eyes underwent EMM surgery without the aid of ICG (group I) and seventeen underwent EMM ICG-assisted surgery assisted using ICG (group II). The amount of Muller cell debris on the retinal surface of the ILM was more significant in the group I (no ICG) than in the group II (ICG) (40.8 versus 11.8; p = 0.024). Large fragments of Muller cells were more frequently observed in the group I (no ICG) than in the group II (ICG) (63.4% versus 23.5%; p= 0.003).The presence of larger retinal elements such as neural axons and vessels were observed attached to retinal face of the ILM in 5 (7%) cases of the no-ICG group. No such retinal elements were detected in any of the histological ILM specimens of the ICG-assisted group Conclusions:The use of ICG diluted with 5% glucose in the aid of ILM removal during epiretinal membrane surgery was associated with less retinal debris attached to retinal face of the ILM compared to surgery in which ICG was not used. Our findings contradict previous reports in the literature, in which use of ICG diluted with balanced salt solution (BSS) was associated with more retinal fragments attached to the retinal face of the ILM. According to our results, we hypothesize that diluting ICG with 5% glucose may decrease the adhesion of the ILM to the underlying retinal layers such that less retinal debris is removed with peeling of the ILM.
Resumo:
Plasma catecholamines provide a reliable biomarker of sympathetic activity. The low circulating concentrations of catecholamines and analytical interferences require tedious sample preparation and long chromatographic runs to ensure their accurate quantification by HPLC with electrochemical detection. Published or commercially available methods relying on solid phase extraction technology lack sensitivity or require derivatization of catecholamine by hazardous reagents prior to tandem mass spectrometry (MS) analysis. Here, we manufactured a novel 96-well microplate device specifically designed to extract plasma catecholamines prior to their quantification by a new and highly sensitive ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. Processing time, which included sample purification on activated aluminum oxide and elution, is less than 1 h per 96-well microplate. The UPLC-MS/MS analysis run time is 2.0 min per sample. This UPLC-MS/MS method does not require a derivatization step, reduces the turnaround time by 10-fold compared to conventional methods used for routine application, and allows catecholamine quantification in reduced plasma sample volumes (50-250 μL, e.g., from children and mice).
Resumo:
Conventional methods are sometimes insufficient to identify human bacterial pathogens, and alternative techniques, often molecular, are required. Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identified with a valid score 45.9% of 410 clinical isolates from 207 different difficult-to-identify species having required 16S rRNA gene sequencing. MALDI-TOF MS might represent an alternative to 16S rRNA gene sequencing.
Resumo:
The main objective of this study is to determine the effectiveness of the Electrochemical Chloride Extraction (ECE) technique on a bridge deck with very high concentrations of chloride. This ECE technique was used during the summer of 2003 to reverse the effects of corrosion, which had occurred in the reinforcing steel embedded in the pedestrian bridge deck over Highway 6, along Iowa Avenue, in Iowa City, Iowa, USA. First, the half cell potential was measured to determine the existing corrosion level in the field. The half-cell potential values were in the indecisive range of corrosion (between -200 mV and -350 mV). The ECE technique was then applied to remove the chloride from the bridge deck. The chloride content in the deck was significantly reduced from 25 lb/cy to 4.96 lb/cy in 8 weeks. Concrete cores obtained from the deck were measured for their compressive strengths and there was no reduction in strength due to the ECE technique. Laboratory tests were also performed to demonstrate the effectiveness of the ECE process. In order to simulate the corrosion in the bridge deck, two reinforced slabs and 12 reinforced beams were prepared. First, the half-cell potentials were measured from the test specimens and they all ranged below -200 mV. Upon introduction of 3% salt solution, the potential reached up to -500 mV. This potential was maintained while a salt solution was being added for six months. The ECE technique was then applied to the test specimens in order to remove the chloride from them. Half-cell potential was measured to determine if the ECE technique can effectively reduce the level of corrosion.
Resumo:
BACKGROUND: For patients with acute iliofemoral deep vein thrombosis, it remains unclear whether the addition of intravascular high-frequency, low-power ultrasound energy facilitates the resolution of thrombosis during catheter-directed thrombolysis. METHODS AND RESULTS: In a controlled clinical trial, 48 patients (mean age 50 ± 21 years, 52% women) with acute iliofemoral deep vein thrombosis were randomized to receive ultrasound-assisted catheter-directed thrombolysis (N = 24) or conventional catheter-directed thrombolysis (N = 24). Thrombolysis regimen (20 mg r-tPA over 15 hours) was identical in all patients. The primary efficacy end point was the percentage of thrombus load reduction from baseline to 15 hours according to the length-adjusted thrombus score, obtained from standardized venograms and evaluated by a core laboratory blinded to group assignment. The percentage of thrombus load reduction was 55% ± 27% in the ultrasound-assisted catheter-directed thrombolysis group and 54% ± 27% in the conventional catheter-directed thrombolysis group (P = 0.91). Adjunctive angioplasty and stenting was performed in 19 (80%) patients and in 20 (83%) patients, respectively (P > 0.99). Treatment-related complications occurred in 3 (12%) and 2 (8%) patients, respectively (P > 0.99). At 3-month follow-up, primary venous patency was 100% in the ultrasound-assisted catheter-directed thrombolysis group and 96% in the conventional catheter-directed thrombolysis group (P = 0.33), and there was no difference in the severity of the post-thrombotic syndrome (mean Villalta score: 3.0 ± 3.9 [range 0-15] versus 1.9 ± 1.9 [range 0-7]; P=0.21), respectively. CONCLUSIONS: In this randomized controlled clinical trial of patients with acute iliofemoral deep vein thrombosis treated with a fixed-dose catheter thrombolysis regimen, the addition of intravascular ultrasound did not facilitate thrombus resolution. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01482273.
Resumo:
The objective of this work was to validate microsatellite markers associated with resistance to soybean cyst nematode (Heterodera glycines Ichinohe) races 3 and 14, in soybean (Glycine max L.) genotypes, for use in marker-assisted selection (MAS) programs. Microsatellites of soybean linkage groups A2, D2 and G were tested in two populations, and their selection efficiencies were determined. The populations were 65 F2:3 families from Msoy8001 (resistant) x Conquista (susceptible) cross, and 66 F2:3 families of S5995 (resistant) x Renascença (susceptible) cross, evaluated for resistance to races 3 and 14, respectively. Families with female index up to 30% were considered moderately resistant. Markers of A2 and G linkage groups were associated with resistance to race 3. Markers Satt309 and GMENOD2B explained the greatest proportion of phenotypic variance in the different groups. The combinations Satt309+GMENOD2B and Satt309+Satt187 presented 100% selection efficiency. Resistance to race 14 was associated with markers of G linkage group, and selection efficiency in the Satt309+Satt356 combination was 100%. The selection differential obtained by phenotypic and marker assisted selection showed that both can result in similar gains.
Resumo:
Different vortex penetration regimes have been registered in the output voltage signal of a magnetometer when single microwave pulses are applied to an epitaxial overdoped La2− x Sr x CuO4 thin film in a perpendicular dc magnetic field. The onset of a significant variation in the sample magnetization which exists below threshold values of temperature, dc magnetic field, and pulse duration is interpreted as an avalanche-type flux penetration. The microwave contribution to the background electric field suggests that the nucleation of this fast vortex motion is of electric origin, which also guarantees the occurrence of vortex instabilities under adiabatic conditions via the enhancement of the flux flow resistivity. Flux creep phenomena and heat transfer effects act as stabilizing factors against the microwave-pulse-induced fast flux diffusion.
Resumo:
Aim Avoiding 'mini-laparotomy' to extract a colectomy specimen may decrease wound complications and further improve recovery after laparoscopic surgery. The aim of this study was to develop a new technique for transrectal specimen extraction (TRSE) and to compare it with conventional laparoscopy (CL) for left sided colectomy. Method Eleven patients with benign disease requiring either sigmoid or left colon resection underwent TRSE. The unfired circular stapler was inserted transanally and used as a guide to suture-close the recto-sigmoid junction laparoscopically and as a handle to pull the sutured sigmoid through the opened rectum inside a laparoscopic camera bag. The anvil was inserted into the lumen of the intussuscepted sigmoid and pushed to the level of the anastomosis. The anastomosis was fashioned end-to-end in the first patients and side-to-end in the following patients to improve safety. Intra-operative and postoperative outcomes of patients undergoing TRSE were compared with those of a group of 20 patients undergoing CL, who were matched for type of resection, body mass index and age. Results The procedure was successful in all but the first patient who was converted to conventional laparoscopic colectomy without any additional morbidity. Two patients in the end-to-end anastomosis group, but none in the side-to-end group, developed peri-anastomotic sepsis. Compared with CL, patients undergoing TRSE did not show any significant differences in operative time, recovery or morbidity. Conclusion Transrectal specimen extraction after left colectomy using the circular stapler technique is feasible. A side-to-end anastomosis appears safer than an end-to-end anastomosis. Further studies are needed to explore the potential advantages of this procedure over CL.
Resumo:
A straightforward methodology for the synthesis of conjugates between a cytotoxic organometallic ruthenium(II) complex and amino- and guanidinoglycosides, as potential RNA-targeted anticancer compounds, is described. Under microwave irradiation, the imidazole ligand incorporated on the aminoglycoside moiety (neamine or neomycin) was found to replace one triphenylphosphine ligand from the ruthenium precursor [(η6-p-cym)RuCl(PPh3)2]+, allowing the assembly of the target conjugates. The guanidinylated analogue was easily prepared from the neomycin-ruthenium conjugate by reaction with N,N′-di-Boc-N″-triflylguanidine, a powerful guanidinylating reagent that was compatible with the integrity of the metal complex. All conjugates were purified by semipreparative high-performance liquid chromatography (HPLC) and characterized by electrospray ionization (ESI) and matrix-assisted laser desorptionionization time-of-flight (MALDI-TOF) mass spectrometry (MS) and NMR spectroscopy. The cytotoxicity of the compounds was tested in MCF-7 (breast) and DU-145 (prostate) human cancer cells, as well as in the normal HEK293 (Human Embryonic Kidney) cell line, revealing a dependence on the nature of the glycoside moiety and the type of cell (cancer or healthy). Indeed, the neomycinruthenium conjugate (2) displayed moderate antiproliferative activity in both cancer cell lines (IC50 ≈ 80 μM), whereas the neamine conjugate (4) was inactive (IC50 ≈ 200 μM). However, the guanidinylated analogue of the neomycinruthenium conjugate (3) required much lower concentrations than the parent conjugate for equal effect (IC50 = 7.17 μM in DU-145 and IC50 = 11.33 μM in MCF-7). Although the same ranking in antiproliferative activity was found in the nontumorigenic cell line (3 2 > 4), IC50 values indicate that aminoglycoside-containing conjugates are about 2-fold more cytotoxic in normal cells (e.g., IC50 = 49.4 μM for 2) than in cancer cells, whereas an opposite tendency was found with the guanidinylated conjugate, since its cytotoxicity in the normal cell line (IC50 = 12.75 μM for 3) was similar or even lower than that found in MCF-7 and DU-145 cancer cell lines, respectively. Cell uptake studies performed by ICP-MS with conjugates 2 and 3 revealed that guanidinylation of the neomycin moiety had a positive effect on accumulation (about 3-fold higher in DU-145 and 4-fold higher in HEK293), which correlates well with the higher antiproliferative activity of 3. Interestingly, despite the slightly higher accumulation in the normal cell than in the cancer cell line (about 1.4-fold), guanidinoneomycinruthenium conjugate (3) was more cytotoxic to cancer cells (about 1.8-fold), whereas the opposite tendency applied for neomycinruthenium conjugate (2). Such differences in cytotoxic activity and cellular accumulation between cancer and normal cells open the way to the creation of more selective, less toxic anticancer metallodrugs by conjugating cytotoxic metal-based complexes such as ruthenium(II) arene derivatives to guanidinoglycosides.
Resumo:
Background:There is no actual evidence that the ART are directly related to the occurrence of weight discordance. In some studies, ART-‐conceived twin pregnancies are at greater risk than non-‐ART-‐conceived ones for pregnancy complications and adverse perinatal outcome: the incidences of pregnancy-‐induced hypertension, uterine bleeding, premature contractions, IUGR, fetal death, discordance, and cesarean section were significantly higher. Discordance rate was elevated (25.3% vs.17.0%) among ART twins, which can increase perinatal risk (increased incidence of SGA and NICU admission). Other studies say that perinatal and neonatal morbidity, gestational age at delivery, and birth weight are not affected by ART. Regarding the first trimester ultrasound, some studies didn’t notice significant differences in CRL disparity or birth weight discordance between spontaneous and ART-‐ conceived dichorionic twin pregnancies. In ART-‐conceived dichorionic twin pregnancies, CRL disparity may be associated with birth weight discordance. In some studies, CRL discordance in twin pregnancies in the first trimester was a frequent finding. Objectives: To analyze the association of the ART in the occurrence of weight discordance in the pregnancies between 2010 and 2013 in the Hospital Universitari de Girona Doctor Josep Trueta, and to describe the proportion of diagnosis of growth discordance in the first trimester by the ultrasonography technology. Methods: A retrospective cohort study will be performed in those patients with twin pregnancies between 2010 and 2013, within the Hospital Universitari de Girona Doctor Josep Trueta (HUJT). A retrospective and descriptive study will be done in those cases with discordance weight in the moment of the birth, in which the CRL will be studied in the first trimester ultrasound, describing the percentage of discordance detected in that moment. The general characteristics of the sample are going to be analyzed by Logistic RegressionInfluenceof
Resumo:
Background:There is no actual evidence that the ART are directly related to the occurrence of weight discordance. In some studies, ART-‐conceived twin pregnancies are at greater risk than non-‐ART-‐conceived ones for pregnancy complications and adverse perinatal outcome: the incidences of pregnancy-‐induced hypertension, uterine bleeding, premature contractions, IUGR, fetal death, discordance, and cesarean section were significantly higher. Discordance rate was elevated (25.3% vs.17.0%) among ART twins, which can increase perinatal risk (increased incidence of SGA and NICU admission). Other studies say that perinatal and neonatal morbidity, gestational age at delivery, and birth weight are not affected by ART. Regarding the first trimester ultrasound, some studies didn’t notice significant differences in CRL disparity or birth weight discordance between spontaneous and ART-‐ conceived dichorionic twin pregnancies. In ART-‐conceived dichorionic twin pregnancies, CRL disparity may be associated with birth weight discordance. In some studies, CRL discordance in twin pregnancies in the first trimester was a frequent finding. Objectives: To analyze the association of the ART in the occurrence of weight discordance in the pregnancies between 2010 and 2013 in the Hospital Universitari de Girona Doctor Josep Trueta, and to describe the proportion of diagnosis of growth discordance in the first trimester by the ultrasonography technology. Methods: A retrospective cohort study will be performed in those patients with twin pregnancies between 2010 and 2013, within the Hospital Universitari de Girona Doctor Josep Trueta (HUJT). A retrospective and descriptive study will be done in those cases with discordance weight in the moment of the birth, in which the CRL will be studied in the first trimester ultrasound, describing the percentage of discordance detected in that moment. The general characteristics of the sample are going to be analyzed by Logistic RegressionInfluenceof
Resumo:
We report on the growth of epitaxial YBa2Cu3O7 thin films on X-cut LiNbO3 single crystals. The use of double CeO2/YSZ buffer layers allows a single in-plane orientation of YBa2Cu3O7, and results in superior superconducting properties. In particular, surface resistance Rs values of 1.4 m¿ have been measured at 8 GHz and 65 K. The attainment of such low values of Rs constitutes a key step toward the incorporation of high Tc materials as electrodes in photonic and acoustic devices.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
Background:There is no actual evidence that the ART are directly related to the occurrence of weight discordance. In some studies, ART-‐conceived twin pregnancies are at greater risk than non-‐ART-‐conceived ones for pregnancy complications and adverse perinatal outcome: the incidences of pregnancy-‐induced hypertension, uterine bleeding, premature contractions, IUGR, fetal death, discordance, and cesarean section were significantly higher. Discordance rate was elevated (25.3% vs.17.0%) among ART twins, which can increase perinatal risk (increased incidence of SGA and NICU admission). Other studies say that perinatal and neonatal morbidity, gestational age at delivery, and birth weight are not affected by ART. Regarding the first trimester ultrasound, some studies didn’t notice significant differences in CRL disparity or birth weight discordance between spontaneous and ART-‐ conceived dichorionic twin pregnancies. In ART-‐conceived dichorionic twin pregnancies, CRL disparity may be associated with birth weight discordance. In some studies, CRL discordance in twin pregnancies in the first trimester was a frequent finding. Objectives: To analyze the association of the ART in the occurrence of weight discordance in the pregnancies between 2010 and 2013 in the Hospital Universitari de Girona Doctor Josep Trueta, and to describe the proportion of diagnosis of growth discordance in the first trimester by the ultrasonography technology. Methods: A retrospective cohort study will be performed in those patients with twin pregnancies between 2010 and 2013, within the Hospital Universitari de Girona Doctor Josep Trueta (HUJT). A retrospective and descriptive study will be done in those cases with discordance weight in the moment of the birth, in which the CRL will be studied in the first trimester ultrasound, describing the percentage of discordance detected in that moment. The general characteristics of the sample are going to be analyzed by Logistic RegressionInfluenceof