992 resultados para lasers and laser optics


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: We tested the hypothesis that LED phototherapy with combined 660-nm and 890-nm light will promote healing of venous ulcers that failed to respond to other forms of treatment. Background Data: A variety of dressings, growth factors, and adjunct therapies are used to treat venous ulcers, but none seems to yield satisfactory results. Materials and Methods: We used a randomized placebo-controlled double-blind study to compare a total of 20 patients divided with 32 chronic ulcers into three groups. In group 1 the ulcers were cleaned, dressed with 1% silver sulfadiazine (SDZ) cream, and treated with placebo phototherapy (<.03 J/cm(-3)) using a Dynatron Solaris 705 phototherapy research device. In group 2 the ulcers were treated similarly but received real phototherapy (3 J/cm(-2)) instead of placebo. In group 3 (controls), the ulcers were simply cleaned and dressed with SDZ without phototherapy. The ulcers were evaluated with digital photography and computer image analysis over 90 d or until full healing was attained. Results: Ulcers treated with phototherapy healed significantly faster than controls when compared at day 30 (p < 0.01), day 60 (p < 0.05), and day 90 (p < 0.001), and similarly healed faster than the placebo-treated ulcers at days 30 and 90 (p < 0.01), but not at day 60. The beneficial effect of phototherapy was more pronounced when the confounding effect of small-sized ulcers was removed from the analysis. Medium- and large-sized ulcers healed significantly faster with treatment (>= 40% rate of healing per month) than placebo or control ulcers (p < 0.05). Conclusion: Phototherapy promotes healing of chronic venous ulcers, particularly large recalcitrant ulcers that do not respond to conventional treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: We sought to investigate the wound-healing process after photodynamic therapy (PDT) mediated by methylene blue dye (MB). Background Data: Few scientific studies show the PDT roles in wound healing. Materials and Methods: One hundred rats were given a circular wound on the back, inflicted with a 6-mm-diameter punch. The animals were divided into four groups: control (no treatment); dye (topical application of MB); laser (InGaAlP, 117.85 J/cm(2), 100 mW, 660 nm, single point); and PDT (topical application of MB followed by laser irradiation). After 1, 3, 5, 7, and 14 days, the cutaneous wounds were photographed and assessed with histopathologic examination by using light microscope. Changes seen in edema, necrosis, inflammation, granulation tissue, re-epithelialization, and number of young fibroblasts were semiquantitatively evaluated. The wound-area changes were measured with special software and submitted to statistical analysis. Results: The laser group demonstrated the smallest wound area at 14 days after the surgical procedure (p<0.01). Concerning complete re-epithelialization, the laser group showed it at 5-7 days after surgery, whereas the PDT and the other groups showed it at 14 days. Conclusions: Laser interaction with tissue is somehow changed when exposed to the MB. PDT mediated by MB was not prejudicial to wound healing, as no delay occurred compared with the control group.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate with light microscopy the healing process of third-degree burns on diabetic rats treated with polarized light (lambda 400-2000 nm, 20 or 40 J/cm(2)/session, 40 mW/cm(2), 2.4 J/cm(2)/min, 5.5-cm beam diameter). Background: Uncontrolled diabetes mellitus causes severe disruption of the body's metabolism, including healing. Polarized light sources have been shown to be effective in improving healing in many situations. Animals and Methods: Diabetes mellitus was induced with streptozotocin (60 mg/kg) in 45 male Wistar albino rats, and a third-degree burn (1.5 by 1.5 cm) was created on the dorsum of each animal under general anesthesia. The animals were randomly distributed into three groups: control, 20 J/cm(2), and 40 J/cm(2). Each group was then divided into three subgroups based on time of death (7, 14, 21 d). Phototherapy (20 or 40 J/cm(2) per session) was carried out immediately after the burning and repeated daily until the day before death. Following animal death, specimens were removed, embedded in paraffin, sectioned, and stained with hematoxylin and eosin (HE) or Sirius Red or immunomarked with CK AE1/AE3 antibody. Qualitative and semiquantitative analyses were performed under light microscopy. The results were statistically analyzed. Results: The animals treated with 20 J/cm(2) showed significant differences with regard to revascularization and re-epithelialization. Although the 40 J/cm(2) group showed stimulation of fibroblastic proliferation as an isolated feature, no other difference from the control was observed. Conclusion: Our results suggest that the use of polarized light at 20 J/cm(2) effectively improves the healing of third-degree burns on diabetic animals at both early and late stages of repair.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was to investigate the effects of photodynamic therapy (PDT) on endodontic pathogens by evaluating the decrease in numbers of Enterococcus faecalis colonies in the canals of extracted human teeth. Background Data: Failure in endodontics is usually related to inadequate cleaning and disinfection of the root canal system. This is due to the establishment of microorganisms in areas where the instruments and chemical agents used during root canal preparation cannot eliminate them. PDT is a complementary therapeutic method that could be used to eliminate these remaining bacteria. PDT is a process in which radiation acts on a dye that is applied to the target organism, resulting in bacterial death. Materials and Methods: Forty-six uniradicular teeth had their canals contaminated with bacteria and were incubated for 48 h at 35 degrees C. After that, the teeth were divided into a control group (CG) and a test group (TG). The 23 CG teeth did not undergo any intervention, whereas in the TG the teeth received a solution of 0.0125% toluidine blue for 5 min followed by irradiation using a 50-mW diode laser (Ga-Al-As) at a wavelength of 660 nm. Bacterial samples were taken before and after irradiation. In each of the samples, the number of colony-forming units (CFU) was counted. Results: The mean decrease in CFU was 99.9% in the TG, whereas in the CG an increase of 2.6% was observed. Conclusion: PDT was effective as a bactericidal agent in Enterococcus faecalis-contaminated root canals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the adhesion of the endodontic sealers Epiphany, Apexit Plus, and AH Plus to root canal dentin submitted to different surface treatments, by using the push-out test. Methods: One hundred twenty-eight root cylinders obtained from maxillary canines were embedded in acrylic resin, had the canals prepared, and were randomly assigned to four groups (n = 32), according to root dentin treatment: (I) distilled water (control), (II) 17% EDTAC, (III) 1% NaOCl and (IV) Er:YAG laser with 16-Hz, 400-mJ input (240-mJ output) and 0.32-J/cm(2) energy density. Each group was divided into four subgroups (n = 8) filled with Epiphany (either dispensed from the automix syringe supplied by the manufacturer or prepared by hand mixing), Apexit Plus, or AH Plus. Data (MPa) were analyzed by ANOVA and Tukey's test. Results: A statistically significant difference (p < 0.01) was found among the root-canal sealers, except for the Epiphany subgroups, which had statistically similar results to each other (p > 0.01): AH Plus (4.77 +/- 0.85), Epiphany/hand mixed (3.06 +/- 1.34), Epiphany/automix syringe (2.68 +/- 1.35), and Apexit Plus (1.22 +/- 0.33). A significant difference (p < 0.01) was found among the dentin surface treatments. The highest adhesion values were obtained with AH Plus when root dentin was treated with Er: YAG laser and 17% EDTAC. Epiphany sealer presented the lowest adhesion values to root dentin treated with 17% EDTAC. Conclusions: The resin-based sealers had different adhesive behaviors, depending on the treatment of root canal walls. The mode of preparation of Epiphany (automix syringe or hand mixing) did not influence sealer adhesion to root dentin.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background data: Technology and physical exercise can enhance physical performance during aging. Objective: The purpose of this study was to investigate the effects of infrared-light-emitting diode (LED) illumination (850 nm) applied during treadmill training. Materials and methods: Twenty postmenopausal women participated in this study. They were randomly divided into two groups. The LED group performed treadmill training associated with infrared-LED illumination (n = 10) and the control group performed only treadmill training (n = 10). The training was performed during 3 months, twice a week during 30 min at intensities between 85 and 90% of maximal heart rate. The irradiation parameters were 31 mW/cm(2), treatment time 30 min, 14,400 J of total energy and 55.8 J/cm(2) of fluence. Physiological, biomechanical, and body composition parameters were measured at the baseline and after 3 months. Results: Both groups improved the time of tolerance limit (Tlim) (p < 0.05) during submaximal constant-speed testing. The peak torque did not differ between groups. However, the results showed significantly higher values of power [from 56 +/- 10 to 73 +/- 8W (p = 0.002)] and total work [from 1,537 +/- 295 to 1,760 +/- 262 J (p = 0.006)] for the LED group when compared to the control group [power: from 58 +/- 14 to 60 +/- 15W (p >= 0.05) and total work: from 1,504 +/- 404 to 1,622 +/- 418 J (p >= 0.05)]. The fatigue significantly increased for the control group [from 51 +/- 6 to 58 +/- 5 % (p = 0.04)], but not for the LED group [from 60 +/- 10 to 60 +/- 4 % (p >= 0.05)]. No significant differences in body composition were observed for either group. Conclusions: Infrared-LED illumination associated with treadmill training can improve muscle power and delay leg fatigue in postmenopausal women.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of this study was the evaluation of two different photosensitizers activated by red light emitted by light-emitting diodes (LEDs) in the decontamination of carious bovine dentin. Materials and Methods: Fifteen bovine incisors were used to obtain dentin samples which were immersed in brain-heart infusion culture medium supplemented with 1% glucose, 2% sucrose, and 1% young primary culture of Lactobacillus acidophilus 108 CFU/mL and Streptococcus mutans 108 CFU/mL for caries induction. Three different concentrations of the Photogem solution, a hematoporphyrin derivative (1, 2, and 3 mg/mL) and two different concentrations of toluidine blue O (TBO), a basic dye (0.025 and 0.1 mg/mL) were used. To activate the photosensitizers two different light exposure times were used: 60 sec and 120 sec, corresponding respectively to the doses of 24 J/cm(2) and 48 J/cm(2). Results: After counting the numbers of CFU per milligram of carious dentin, we observed that the use of LED energy in association with Photogem or TBO was effective for bacterial reduction in carious dentin, and that the greatest effect on S. mutans and L. acidophilus was obtained with TBO at 0.1 mg/mL and a dose of 48 J/cm(2). It was also observed that the overall toxicity of TBO was higher than that of Photogem, and that the phototoxicity of TBO was higher than that of Photogem. Conclusion: Based on our data we propose a mathematical model for the photodynamic effect when different photosensitizer concentrations and light doses are used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This article describes two inexpensive photodynamic antimicrobial chemotherapy (PACT) protocols to provide intensive local care on ulcerated feet of diabetic patients with osteomyelitis. Background Data: Patients with this condition generally have poor quality of life. The usual treatment consists of the administration of a cocktail of drugs including anti-inflammatories, promoters of blood circulation, and systemic antibiotics. However, depending on the conditions of the tissues, amputation may be required. Consequently, it is important to develop PACT protocols that can help avoid amputation. Materials and Methods: Two PACT protocols were applied to two diabetic patients with osteomyelitis. These protocols were based on several PACT sessions that consisted of: (1) local injection of mixtures of phenothiazines (2% in water) and Hypericum perforatum extract (10% in propylene glycol), and (2) illumination, lasting 10 min, applied to the lesion's interior and exterior using, respectively, an optical fiber and a non-coherent light source. The frequency of PACT was daily or every other day in the beginning, and weekly after tissue recovery begun. The patients were followed clinically and by radiographic testing. Results: Both PACT protocols helped cure these patients who were about to have amputation of their feet. Radiograms showed that bone had healed and that the bone's texture had improved. Conclusion: Here we have described efficient and affordable PACT protocols to treat osteomyelitis in the feet of diabetic patients. This treatment modality should be considered by vascular surgeons and by orthopedists to treat osteomyelitis that is resistant to conventional treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and easy approach to produce polymeric microchips with integrated copper electrodes for capacitively coupled contactless conductivity detection (CD) is described. Copper electrodes were fabricated using a printed circuit board (PCB) as an inexpensive thin-layer of metal. The electrode layout was first drawn and laser printed on a wax paper sheet. The toner layer deposited on the paper sheet was thermally transferred to the PCB surface working as a mask for wet chemical etching of the copper layer. After the etching step, the toner was removed with an acetonitrile-dampened cotton. A poly(ethylene terephthalate) (PET) film coated with a thin thermo-sensitive adhesive layer was used to laminate the PCB plate providing an insulator layer of the electrodes to perform CID measurements. Electrophoresis microchannels were fabricated in poly(dimethylsiloxane) (PDMS) by soft lithography and reversibly sealed against the PET film. These hybrid PDMS/PET chips exhibited a stable electroosmotic mobility of 4.25 +/- 0.04 x 10(-4) V cm(-2) s(-1), at pH 6.1, over fifty runs. Efficiencies ranging from 1127 to 1690 theoretical plates were obtained for inorganic cations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article discusses possible approaches for optical network capacity upgrade by considering the use of different modulation formats at 40 Gb/s. First, a performance evaluation is carried out regarding tolerance to three impairments: spectral narrowing due to filter cascading, chromatic dispersion, and self-phase modulation. Next, a cost-benefit analysis is conducted, considering the specific optoelectronic components required for the optical transmitter/receiver configuration of each format.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, a detailed numerical investigation is presented, seeking to enhance the birefringence effect by using D-shaped microstructured optical fibers (MOFs). We studied a D-shape core geometry associated with three different air-hole configurations: circular and elliptical, aligned with either the x-direction or the y-direction. Results have shown that ultrahigh birefringence MOFs, with B values of the order of 10(-2) for a wide range of wavelengths, can be obtained. The highest birefringence B was equal 3.97 x 10(-2), a value found for a D-MOF (circular holes) at 1550 nm. To the best of our knowledge, this is the highest theoretical value in the published literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To study the oculometric parameters of hyperopia in children with esotropic amblyopia, comparing amblyopic eyes with fellow eyes. Methods: Thirty-seven patients (5-8 years old) with bilateral hyperopia and esotropic amblyopia underwent a comprehensive ophthalmic examination, including cycloplegic refraction, keratometry and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. The refractive power of the crystalline lens was calculated using Bennett`s equations. Paired Student`s t-tests were used to compare ocular biometric measurements between amblyopic eyes and their fellow eyes. The associations of biometric parameters with refractive errors were assessed using Pearson correlation coefficients and linear regression. Multivariable models including axial length, corneal power and lens power were also constructed. Results: Amblyopic eyes were found to have significantly more hyperopic refraction, less corneal power, greater lens power, shorter vitreous chamber depth and shorter axial length, despite similar anterior chamber depth and lens thickness. The strongest correlation with refractive error was observed for the axial length/corneal radius ratio (r(36) = -0.92, p < 0.001 for amblyopic and r(36) = 0.87, p < 0.001 for fellow eyes). Axial length accounted for 39.2% (R(2)) of the refractive error variance in amblyopic eyes and 35.5% in fellow eyes. Adding corneal power to the model increased R(2) to 85.7% and 79.6%, respectively. A statistically significant correlation was found between axial length and corneal power, indicating decreasing corneal power with increasing axial length, and they were similar for amblyopic eyes (r(36) = 0.53,p < 0.001) and fellow eyes (r(36) = -0.57, p < 0.001). A statistically significant correlation was also found between axial length and lens power, indicating decreasing lens power with increasing axial length (r(36) = -0.72, p < 0.001 for amblyopic eyes and r(36) = -0.69, p < 0.001 for fellow eyes). Conclusions: We observed that the correlation among the major oculometric parameters and their individual contribution to hyperopia in esotropic children were similar in amblyopic and non-amblyopic eyes. This finding suggests that the counterbalancing effect of greater corneal and lens power associated with shorter axial length is similar in both eyes of patients with esotropic amblyopia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Zenker`s diverticulum (ZD) is a rare condition with a reported prevalence of 0.01% to 0.11% in the general population. Endoscopic treatment consists of the division of the septum between the diverticulum and the esophagus, within which the cricopharyngeal muscle is contained. Diathermic monopolar current, argon plasma coagulation, and laser have been used to incise the muscular septum with satisfactory results. The main limitation of endoscopic treatment is the occurrence of complications. Perforation and hemorrhage are reported in as many as 23% and 10% of patients, respectively. Objective: The aim of this study was to use the technique of endoscopic diverticulotomy by using a harmonic scalpel in patients with ZD and to demonstrate the feasibility of using flexible and rigid devices in ZD treatment. Design: Case series study. Standard protocol was used for patient management, endoscopic procedure, and data collection. Setting: Single endoscopist demonstrating preliminary results. Patients: Five patients (4 men; median standard deviation [SD] age 69.6 +/- 9.06 years, range 59-83 years) with ZD were treated with this technique. All patients reported dysphagia and halitosis. The diagnosis was based on clinical, endoscopic, and radiographic findings. Interventions: All patients received general anesthesia and were placed in the left lateral position. A standard videogastroscope (9.8 mm) and a stiff guidewire were used to insert and achieve an adequate exposure of the ZD septum. The septum was divided using a harmonic scalpel under thin endoscope (5.2 mm) visualization through a soft diverticuloscope. Main Outcome Measurement: Feasibility of an endoscopic technique by using rigid and flexible devices to treat ZD. Results: Four patients (80%) were successfully treated in 1 session. The median SD size of the diverticulum was 3.6 +/- 0.89 cm (range 3-5 cm). Median SD procedure time was 17.33 +/- 2.33 minutes (range 15-20 minutes) in 6 procedures. No hemorrhage or perforation occurred. One patient (20%) required a second session to complete dissection of the ZD septum. All patients demonstrated improvement of dysphagia score after treatment. Limitations: Small case series design. Conclusions: Endoscopic treatment of ZD by harmonic scalpel through a soft diverticuloscope was feasible and effective in this small case series. Larger studies are warranted to further evaluate this technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To report the experience with fetal cystoscopy and laser fulguration of posterior urethral values (PUV) for severe lower urinary tract obstruction (LUTO). Methods Between July 2006 and December 2008, fetal cystoscopy was offered to 23 patients whose fetuses presented with severe LUTO. favorable urinary analysis and gestational age <26 weeks. Fetal urinary biochemistry was evaluated before and after cystoscopy. All infants were followed 6-12 months after birth. Abnormal renal function was defined when serum creatinine higher than 50 mu mol/L (2 Standard Deviation) or the necessity of dialysis or renal transplantation. Autopsy was always performed whenever fetal or neonatal deaths occurred. Results Eleven patients decided to undergo fetal therapy and 12 elected to continue with expectant observation. There was no difference between both groups in gestation age at diagnosis and referral examinations. Urethral atresia was diagnosed in 4/11 (36.4%) fetuses by fetal cystoscopy. At 26 weeks, fetuses that were managed expectantly presented with worse urinary biochemistry results (p < 0.05). Survival rates and percentage of infants with normal renal function were significantly higher in the cystoscopic group than in the expectant group (P < 0.05). Conclusions Percutaneous fetal cystoscopy is feasible using a thinner special cannula for prenatal diagnosis and therapy of LUTO. Prenatal laser ablation of the PUV under cystoscopy may prevent renal function deterioration improving postnatal outcome. Copyright (C) 2009 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Different modalities of palliation for obstructive symptoms in patients with unresectable esophageal cancer (EC) exist. However, these therapeutic alternatives have significant differences in costs and effectiveness. Methods A Markov model was designed to compare the cost-effectiveness (CE) of self-expandable stent (SES), brachytherapy and laser in the palliation of unresectable EC. Patients were assigned to one of the strategies, and the improvement in swallowing function was compared given the treatment efficacy, probability of survival, and risks of complications associated to each strategy. Probabilities and parameters for distribution were based on a 9-month time frame. Results Under the base-case scenario, laser has the lowest CE ratio, followed by brachytherapy at an incremental cost-effectiveness ratio (ICER) of $4,400.00, and SES is a dominated strategy. In the probabilistic analysis, laser is the strategy with the highest probability of cost-effectiveness for willingness to pay (WTP) values lower than $3,201 and brachytherapy for all WTP yielding a positive net health benefit (NHB) (threshold $4,440). The highest probability of cost-effectiveness for brachytherapy is 96%, and consequently, selection of suboptimal strategies can lead to opportunity losses for the US health system, ranging from US$ 4.32 to US$ 38.09 million dollars over the next 5-20 years. Conclusion Conditional to the WTP and current US Medicare costs, palliation of unresectable esophageal cancers with brachytherapy provides the largest amount of NHB and is the strategy with the highest probability of CE. However, some level of uncertainly remains, and wrong decisions will be made until further knowledge is acquired.