998 resultados para hengelliset laulut - 1600-luku


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and sensitive liquid chromatography-electrospray ionization mass spectrometry method was developed for the simultaneous quantification in human plasma of all selective serotonin reuptake inhibitors (citalopram, fluoxetine, fluvoxamine, paroxetine and sertraline) and their main active metabolites (desmethyl-citalopram and norfluoxetine). A stable isotope-labeled internal standard was used for each analyte to compensate for the global method variability, including extraction and ionization variations. After sample (250μl) pre-treatment with acetonitrile (500μl) to precipitate proteins, a fast solid-phase extraction procedure was performed using mixed mode Oasis MCX 96-well plate. Chromatographic separation was achieved in less than 9.0min on a XBridge C18 column (2.1×100mm; 3.5μm) using a gradient of ammonium acetate (pH 8.1; 50mM) and acetonitrile as mobile phase at a flow rate of 0.3ml/min. The method was fully validated according to Société Française des Sciences et Techniques Pharmaceutiques protocols and the latest Food and Drug Administration guidelines. Six point calibration curves were used to cover a large concentration range of 1-500ng/ml for citalopram, desmethyl-citalopram, paroxetine and sertraline, 1-1000ng/ml for fluoxetine and fluvoxamine, and 2-1000ng/ml for norfluoxetine. Good quantitative performances were achieved in terms of trueness (84.2-109.6%), repeatability (0.9-14.6%) and intermediate precision (1.8-18.0%) in the entire assay range including the lower limit of quantification. Internal standard-normalized matrix effects were lower than 13%. The accuracy profiles (total error) were mainly included in the acceptance limits of ±30% for biological samples. The method was successfully applied for routine therapeutic drug monitoring of more than 1600 patient plasma samples over 9 months. The β-expectation tolerance intervals determined during the validation phase were coherent with the results of quality control samples analyzed during routine use. This method is therefore precise and suitable both for therapeutic drug monitoring and pharmacokinetic studies in most clinical laboratories.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Deep burn assessment made by clinical evaluation has an accuracy varying between 60% and 80% and will determine if a burn injury will need tangential excision and skin grafting or if it will be able to heal spontaneously. Laser Doppler Imaging (LDI) techniques allow an improved burn depth assessment but their use is limited by the time-consuming image acquisition which may take up to 6 min per image. METHODS: To evaluate the effectiveness and reliability of a newly developed full-field LDI technology, 15 consecutive patients presenting with intermediate depth burns were assessed both clinically and by FluxExplorer LDI technology. Comparison between the two methods of assessment was carried out. RESULTS: Image acquisition was done within 6 s. FluxEXPLORER LDI technology achieved a significantly improved accuracy of burn depth assessment compared to the clinical judgement performed by board certified plastic and reconstructive surgeons (P < 0.05, 93% of correctly assessed burns injuries vs. 80% for clinical assessment). CONCLUSION: Technological improvements of LDI technology leading to a decreased image acquisition time and reliable burn depth assessment allow the routine use of such devices in the acute setting of burn care without interfering with the patient's treatment. Rapid and reliable LDI technology may assist clinicians in burn depth assessment and may limit the morbidity of burn patients through a minimization of the area of surgical debridement. Future technological improvements allowing the miniaturization of the device will further ease its clinical application.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Glycodelin (PP14) is produced by the epithelium of the endometrium and its determination in the serum is used for functional evaluation of this tissue. Given the complex regulation and the combined contraceptive and immunosuppressive roles of glycodelin, the current lack of normal values for its serum concentration in the physiological menstrual cycle, derived from a large sample number, is a problem. We have therefore established reference values from over 600 sera. DESIGN: Retrospective study using banked serum samples. SETTING: University hospital. METHODS: Measurement of blood samples daily or every second day during one full cycle. MAIN OUTCOME MEASURES: Serum concentrations of glycodelin and normal values for every such one- or two-day interval were calculated. Late luteal phase glycodelin levels were compared with ovarian hormones. Follicular phase levels were compared with stimulated cycles from patients undergoing in vitro fertilization. RESULTS: Glycodelin concentrations were low around ovulation. Highest levels were observed at the end of the luteal phase; the glycodelin serum peak was reached 6-8 days after the one for progesterone. Late luteal glycodelin levels correlated negatively with the body mass index and positively with the progesterone level earlier in the secretory (mid-luteal) phase in the same woman. No associations with other ovarian hormones were observed. Follicular phase glycodelin levels were higher in the spontaneous than in the in vitro fertilization cycles. CONCLUSIONS: Normal values taken at two- or one-day intervals demonstrate the very late appearance of high serum glycodelin levels during the physiological menstrual cycle and their correlation with progesterone occurring earlier in the cycle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The immunogenicity of influenza vaccine is suboptimal in lung transplant recipients. Use of a booster dose and vaccine delivery by the intradermal rather than intramuscular route may improve response. We prospectively evaluated the immunogenicity and safety of a 2-dose boosting strategy of influenza vaccine. Sixty lung transplant recipients received a standard intramuscular injection of the 2006-2007 inactivated influenza vaccine, followed 4 weeks later by an intradermal booster of the same vaccine. Immunogenicity was assessed by measurement of geometric mean titer of antibodies after both the intramuscular injection and the intradermal booster. Vaccine response was defined as 4-fold or higher increase of antibody titers to at least one vaccine antigen. Thirty-eight out of 60 patients (63%) had a response after intramuscular vaccination. Geometric mean titers increased for all three vaccine antigens following the first dose (p &lt; 0.001). However, no significant increases in titer were observed after the booster dose for all three antigens. Among nonresponders, 3/22 (13.6%) additional patients responded after the intradermal booster (p = 0.14). The use of basiliximab was associated with a positive response (p = 0.024). After a single standard dose of influenza vaccine, a booster dose given by intradermal injection did not significantly improve vaccine immunogenicity in lung transplant recipients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Al-Qur'ān