993 resultados para glucose detection


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This preliminary report describes human and cow cases of poxvirus that recently ocurred in the State of Rio de Janeiro. The electron microscopic findings were consistent with parapoxviral and orthopoxviral infection. Orthopoxvirus strains were isolated from human and cow cases. Detailed viral characterization by means of genetical techniques is under investigation. Based on these informations, poxviral diseases should be also considered an emerging viral zoonosis that can affect human beings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was undertaken to evaluate an enzyme immunoassay (EIA) for hepatitis C virus antibody detection (anti-HCV), using just one antigen. Anti-HCV EIA was designed to detect anti-HCV IgG using on the solid-phase a recombinant C22 antigen localized at the N-terminal end of the core region of HCV genome, produced by BioMérieux. The serum samples diluted in phosphate buffer saline were added to wells coated with the C22, and incubated. After washings, the wells were loaded with conjugated anti-IgG, and read in a microtiter plate reader (492 nm). Serum samples of 145 patients were divided in two groups: a control group of 39 patients with non-C hepatitis (10 acute hepatitis A, 10 acute hepatitis B, 9 chronic hepatitis B, and 10 autoimmune hepatitis) and a study group consisting of 106 patients with chronic HCV hepatitis. In the study group all patients had anti-HCV detected by a commercially available EIA (Abbott®), specific for HCV structural and nonstructural polypeptides, alanine aminotransferase elevation or positive serum HCV-RNA detected by nested-PCR. They also had a liver biopsy compatible with chronic hepatitis. The test was positive in 101 of the 106 (95%) sera from patients in the study group and negative in 38 of the 39 (97%) sera from those in the control group, showing an accuracy of 96%. According to these results, our EIA could be used to detect anti-HCV in the serum of patients infected with hepatitis C virus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral arterial disease (PAD) is a common disease with increasing prevalence, presenting with impaired walking ability affecting patient's quality of life. PAD epidemiology is known, however, mechanisms underlying functional muscle impairment remain unclear. Using a mouse PAD model, aim of this study was to assess muscle adaptive responses during early (1 week) and late (5 weeks) disease stages. Unilateral hindlimb ischemia was induced in ApoE(-/-) mice by iliac artery ligation. Ischemic limb perfusion and oxygenation (Laser Doppler imaging, transcutaneous oxygen pressure assessments) significantly decreased during early and late stage compared to pre-ischemia, however, values were significantly higher during late versus early phase. Number of arterioles and arteriogenesis-linked gene expression increased at later stage. Walking ability, evaluated by forced and voluntary walking tests, remained significantly decreased both at early and late phase without any significant improvement. Muscle glucose uptake ([18F]fluorodeoxyglucose positron emission tomography) significantly increased during early ischemia decreasing at later stage. Gene expression analysis showed significant shift in muscle M1/M2 macrophages and Th1/Th2 T cells balance toward pro-inflammatory phenotype during early ischemia; later, inflammatory state returned to neutrality. Muscular M1/M2 shift inhibition by a statin prevented impaired walking ability in early ischemia. High-energy phosphate metabolism remained unchanged (31-Phosphorus magnetic resonance spectroscopy). Results show that rapid transient muscular inflammation contributes to impaired walking capacity while increased glucose uptake may be a compensatory mechanisms preserving immediate limb viability during early ischemia in a mouse PAD model. With time, increased ischemic limb perfusion and oxygenation assure muscle viability although not sufficiently to improve walking impairment. Subsequent decreased muscle glucose uptake may partly contribute to chronic walking impairment. Early inflammation inhibition and/or late muscle glucose impairment prevention are promising strategies for PAD management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of acid fast bacilli in multiple specimens was investigated comparatively with Ziehl-Neelsen (ZN) and fluorescence microscopy (FM) staining in order to determine sensitivity in detecting tuberculosis (TB). A total of 465 specimens obtained from 295 patients were analysed at Harran University Medical School Hospital between March 1998 and March 2000. The culture was employed as the reference method. Sixty-eight patients (23.1%) were diagnosed as having TB by culture. The ZN and FM staining sensitivities were 67.6% (46/68) and 85.2% (58/68) respectively. Two hundred and one patients (68.1%) submitted one specimen to the laboratory. TB positivity was detected in 42 (20.9%) of these patients by culture. The sensitivities of ZN and FM stains were found to be 61% and 83% in these patients. However, in 18 patients (6.1%) who submitted two specimens to the laboratory, the TB was positive in six of them (33.3%) and ZN and FM sensitivities were 66% and 83% respectively. When three specimens or more were collected from the patients (76 patients, 25.8%), TB positivity was determined in 20 of them (26.3%) and the sensitivities were 80% and 92% in the ZN- and FM-stained smears, respectively. Our data indicate that in the diagnosis of TB, FM has greater sensitivity than ZN. In particular, in the case of a single specimen, the diagnostic value of FM is quite significant. It is, therefore, possible to conclude that both ZN and FM staining can be used for the diagnosis of TB when there are more than two specimens. However, if only one or two specimens are available, FM staining is preferable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the overlapping distribution of Trypanosoma rangeli and T. cruzi in Central and South America, sharing several reservoirs and triatomine vectors, we herein describe a simple method to collect triatomine feces and hemolymph in filter paper for further detection and specific characterization of these two trypanosomes. Experimentally infected triatomines feces and hemolymph were collected in filter paper and specific detection of T. rangeli or T. cruzi DNA by polymerase chain reaction was achieved. This simple DNA collection method allows sample collection in the field and further specific trypanosome detection and characterization in the laboratory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pro-inflammatory cytokines are believed to play an important role in the pathogenesis of dengue infection. This study reports cytokine levels in a total of 54 patients examined in Recife, State of Pernambuco, Brazil. Five out of eight patients who had hemorrhagic manifestations presented tumor necrosis factor-alpha (TNF-alpha) levels in sera which were statistically higher than those recorded for controls. In contrast, only one out of 16 patients with mild manifestations had elevated TNF-alpha levels. The levels of interleukin-6 (IL), IL-1beta tested in 24 samples and IL-12 in 30 samples were not significantly increased. Interferon-g was present in 10 out of 30 patients with dengue. The data support the concept that the increased level of TNF-alpha is related to the severity of the disease. Soluble TNF receptor p75 was found in most patients but it is unlikely to be related to severity since it was found with an equivalent frequency and levels in 15 patients with dengue fever and another 15 with dengue hemorrhagic fever.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A crude antigenic preparation of Babesia bigemina was used to develop an ELISA for the detection of IgM antibodies. Optimal dilutions of the antigen, using positive and negative reference sera, were determined by checkerboard titrations. Negative sera from cattle imported from tick-free areas, serum samples collected from infected B. bigemina cattle were used to validate the test. The specificity was 94% and sensitivity of the Elisa 87.5%. Sera from 385 cattle deriving from areas free from tick-borne diseases, which were submitted to a preimmunization process, were screened by this technique. The Elisa detected seroconversion on the 14th day post-inoculation in animals either infested with Boophilus microplus ticks (infected with B. bigemina), or inoculated with B. bigemina infected blood. Antibody titers decreased after day 33; however, all animals remained positive until the end of the experiment (124 days). The ELISA described may prove to be an appropriate serological test for the detection of IgM antibodies against B. bigemina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay was standardized for the detection of cryptococcal antigen in serum and cerebrospinal fluid. The system was evaluated in clinical samples from patients infected by human immunodeficiency virus with and without previous cryptococcosis diagnosis. The evaluated system is highly sensitive and specific, and when it was compared with latex agglutination there were not significant differences. A standard curve with purified Cryptococcus neoformans antigen was settled down for the antigen quantification in positive samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Microbiological diagnostic procedures have changed significantly over the last decade. Initially the implementation of the polymerase chain reaction (PCR) resulted in improved detection tests for microbes that were difficult or even impossible to detect by conventional methods such as culture and serology, especially in community-acquired respiratory tract infections (CA-RTI). A further improvement was the development of real-time PCR, which allows end point detection and quantification, and many diagnostic laboratories have now implemented this powerful method. Objective: At present, new performant and convenient molecular tests have emerged targeting in parallel many viruses and bacteria responsible for lower and/or upper respiratory tract infections. The range of test formats and microbial agents detected is evolving very quickly and the added value of these new tests needs to be studied in terms of better use of antibiotics, better patient management, duration of hospitalization and overall costs. Conclusions: Molecular tools for a better microbial documentation of CA-RTI are now available. Controlled studies are now required to address the relevance issue of these new methods, such as, for example, the role of some newly detected respiratory viruses or of the microbial DNA load in a particular patient at a particular time. The future challenge for molecular diagnosis will be to become easy to handle, highly efficient and cost-effective, delivering rapid results with a direct impact on clinical management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Limited information is available on the quantitative relationship between family history and the corresponding underlying traits. We analyzed these associations for blood pressure, fasting blood glucose, and cholesterol levels. Methods: Data were obtained from 6,102 Caucasian participants (2,903 men and 3,199 women) aged 35-75 years using a population-based cross-sectional survey in Switzerland. Cardiovascular disease risk factors were measured, and the corresponding family history was self-reported using a structured questionnaire. Results: The prevalence of a positive family history (in first-degree relatives) was 39.6% for hypertension, 22.3% for diabetes, and 29.0% for hypercholesterolemia. Family history was not known for at least one family member in 41.8% of participants for hypertension, 14.4% for diabetes, and 50.2% for hypercholesterolemia. A positive family history was strongly associated with higher levels of the corresponding trait, but not with the other traits. Participants who reported not to know their family history of hypertension had a higher systolic blood pressure than participants with a negative history. Sibling histories had higher positive predictive values than parental histories. The ability to discriminate, calibrate, and reclassify was best for the family history of hypertension. Conclusions: Family history of hypertension, diabetes, and hypercholesterolemia was strongly associated with the corresponding dichotomized and continuous phenotypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PCR detection of Trypanosoma cruzi in Rhodnius prolixus using fresh tissue or fecal drops on filter paper showed comparable results: 38.7% infection rate using the fresh tissue sample and 37.9% by dried fecal drop.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Angiostrongylus costaricensis may cause intestinal lesions of varied severity when it accidentally infects man in Central and South America. First-stage larvae have never been detected in stools. Therefore, a parasite-specific IgG ELISA was evaluated for the determination of the acute phase of infection. The specificity and the sensitivity of the immunoassay was shown to be 76.2% and 91.1%, respectively. Eight serum samples taken from patients with histopathological diagnosis, at different time points (3 to 15 months) after surgical treatment, showed a sharp and early decline in antibody reactivity. The titration of anti-A. costaricensis antibodies has proved to be a useful method for the diagnosis of acute abdominal angiostrongyliasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The identification of arthropod bloodmeals is important in many epidemiological studies, as, the understanding of the life cycle of vectors and the patogens they transmit, as well as helping to define arthropods' control strategies. The precipitin test has been used for decades, but ELISA is slowly becoming more popular. To compare the two tests for sensitivity, specificity and accuracy to detect small insect bloodmeals, Aedes aegypti or Ae. fluviatilis mosquitoes were fed either on feline, canine or human hosts. Mosquitoes were frozen at 6, 12, 24, 48 or 72 h after feeding. Precipitin test showed better specificity and accuracy and ELISA test showed higher sensitivity. Better results with both tests were achieved when mosquitoes were frozen within 48 h from feeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS: Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system before and after intravenous application of a single dose of gadocoletic acid (B-22956) using three different dose regimens (group A 0.050 mmol/kg; group B 0.075 mmol/kg; group C 0.100 mmol/kg). Precontrast scanning followed a coronary MRA standard non-contrast T2 preparation/turbo-gradient echo sequence (T2Prep); for postcontrast scanning an inversion-recovery gradient echo sequence was used (real-time navigator correction for both scans). In pre- and postcontrast scans quantitative analysis of coronary MRA data was performed to determine the number of visible side branches, vessel length and vessel sharpness of each of the three coronary arteries (LAD, LCX, RCA). The number of assessable coronary artery segments was determined to calculate sensitivity and specificity for detection of stenosis > or = 50% on a segment-to-segment basis (16-segment-model) in pre- and postcontrast scans with x-ray coronary angiography as the standard of reference. RESULTS: Dose group B (0.075 mmol/kg) was preferable with regard to improvement of MR angiographic parameters: in postcontrast scans all MR angiographic parameters increased significantly except for the number of visible side branches of the left circumflex artery. In addition, assessability of coronary artery segments significantly improved postcontrast in this dose group (67 versus 88%, p < 0.01). Diagnostic performance (sensitivity, specificity, accuracy) was 83, 77 and 78% for precontrast and 86, 95 and 94% for postcontrast scans. CONCLUSIONS: The use of gadocoletic acid (B-22956) results in an improvement of MR angiographic parameters, asssessability of coronary segments and detection of coronary stenoses > or = 50%.