973 resultados para fluorescein angiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by x-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-venography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les auteurs ont entrepris de mesurer le taux d'utilisation de la coronarographie dans la population résidente, de rechercher des variations d'utilisation selon le sexe, l'âge ou le canton de domicile, et enfin d'identifier des mouvements de patients entre leur domicile et les divers centres pratiquant la coronarographie.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The limitations of the medical management of symptomatic intracranial arterial stenosis encourage the development of new therapeutic strategies such as intracranial stenting. OBJECTIVE: To report and analyze the results of a series of 42 patients treated with 3 different endovascular techniques: isolated angioplasty, balloon-expandable coronary stents, and the Wingspan self-expandable intracranial stent system. METHODS: Forty-two patients presenting with symptomatic intracranial arterial stenosis were treated with one of these techniques. Computed tomography angiography was performed 6 months after the procedure, and the clinical neurological statuses were categorized using the modified Rankin Scale and the National Institutes of Health Stroke Scale. RESULTS: A total of 42 lesions were treated: 9 with isolated angioplasty, 14 with balloon-expandable coronary stents, and 19 with Wingspan self-expandable intracranial stents. The mean patient age was 62.9 years, and the mean arterial diameter stenosis was 73.9%. Technical success was achieved in 97.6% of the patients. The overall incidence of procedural complications was 21.4%, and the postoperative permanent morbidity/mortality rate was 7.1%. There were 3 cases of in-stent thrombosis (1 fatal) and 5 cases of asymptomatic restenosis (11.9%), 3 in the isolated angioplasty group and 2 in the Wingspan self-expandable intracranial stent group (mean follow-up 20.4 months). The rate of restenosis was higher in the angioplasty group (33%) than in the coronary (0%) and Wingspan stent (10.5%) groups. CONCLUSION: Endovascular treatment of symptomatic intracranial stenosis has significant overall morbidity and mortality rates. Nevertheless, the very critical natural history of severe refractory lesions and the relatively favorable postoperative evolution suggest that it should be considered the first alternative strategy in cases in which medical therapy has failed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Summary Background: The combination of the Pulmonary Embolism Severity Index (PESI) and troponin testing could help physicians identify appropriate patients with acute pulmonary embolism (PE) for early hospital discharge. Methods: This prospective cohort study included a total of 567 patients from a single center registry with objectively confirmed acute symptomatic PE. On the basis of the PESI, each patient was classified into 1 of 5 classes (I to V). At the time of hospital admission, patients had troponin I (cTnI) levels measured. The endpoint of the study was all-cause mortality within 30 days after diagnosis. We calculated the mortality rates in 4 patient groups: group 1: PESI class I-II plus cTnI <0.1 ng mL(-1); group 2: PESI classes III-V plus cTnI <0.1 ng mL(-1); group 3: PESI classes I-II plus cTnI >/= 0.1 ng mL(-1); and group 4: PESI classes III-V plus cTnI >/= 0.1 ng mL(-1). Results: The study cohort had a 30-day mortality of 10% (95% confidence interval [CI], 7.6 to 12.5%). Mortality rates in the 4 groups were 1.3%, 14.2%, 0% and 15.4%, respectively. Compared to non-elevated cTnl, the low-risk PESI had a higher negative predictive value (NPV) (98.9% vs 90.8%) and negative likelihood ratio (NLR) (0.1 vs 0.9) for predicting mortality. The addition of non-elevated cTnI to low-risk PESI did not improve the NPV or the NLR compared to either test alone. Conclusions: Compared to cTnl testing, PESI classification more accurately identified patients with PE who are at low risk of all-cause death within 30-days of presentation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Forty-six consecutive patients with pulmonary embolism (PE) who underwent pulmonary angiography, helical computed tomography (CT), and echocardiography in the investigators' emergency department were studied. It was determined that the CT right ventricular (RV)/left ventricular (LV) end-diastolic area ratio was correlated with PE obstruction and echocardiography. A CT RV/LV area ratio &gt;1 had a sensitivity of 88% and a specificity of 88% in diagnosing significant PE. The present study suggests that helical CT may be used as a triage tool in acute PE for selecting high-risk patients, using calculation of the RV/LV area ratio to detect RV dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECT: In 1999 we reported that 94% of unruptured middle cerebral artery (MCA) aneurysms managed prospectively between 1993 and 1997, according to a protocol favoring endovascular coiling, were best treated by surgical clipping. The goal of the current study was to delineate the most appropriate treatment option for unruptured MCA aneurysms today, considering the technical advances in imaging and in endovascular treatment. METHODS: 35 consecutive patients harboring 40 unruptured MCA aneurysms were treated between 1997 and December 2000. Patients with unruptured cerebral aneurysms are managed prospectively according to the same protocol as reported previously [1]: the primary treatment recommendation is endovascular packing with Guglielmi detachable coils (GDCs). Surgical clipping is recommended after failed attempt at coil placement or in the presence of angioanatomical features that contraindicate that type of endovascular therapy. RESULTS: One unruptured MCA aneurysm was treated by endovascular embolization, 37 unruptured MCA aneurysms were clipped, whereas 2 unruptured MCA aneurysms were trapped with simultaneous extracranial-intracranial revascularization. Postoperative angiography revealed complete exclusion of all aneurysms. Preservation of vascular permeability was demonstrated in all clip-reconstructed aneurysms, despite arterial branches frequently originating from the aneurysmal base. Cerebral revascularization of the distal MCA was successful in the 2 patients with giant aneurysms. None of the patients presented permanent disabling complications from the treatment of the unruptured MCA aneurysm. CONCLUSION: Despite major technical advances in imaging and in endovascular treatment of cerebral aneurysms, surgical clipping still is the most efficient treatment for unruptured MCA aneurysms at the beginning of the new millennium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Long occlusions in calcified crural arteries are a major cause of endovascular technical failure in patients with critical limb ischaemia. Therefore, distal bypasses are mainly performed in patients with heavily calcified arteries and with consequently delicate clamping. A new reverse thermosensitive polymer (RTP) is an alternative option to occlude target vessels. The aim of the study is to report our technical experience with RTP and to assess its safety and efficiency to temporarily occlude small calcified arteries during anastomosis time. METHODS: Between July 2010 and December 2011, we used RTP to occlude crural arteries in 20 consecutive patients with 20 venous distal bypasses. We recorded several operative parameters, such as volume of injected RTP, duration of occlusion and anastomotic time. Quality of occlusion was subjectively evaluated. Routine on-table angiography was performed to search for plug emboli. Primary patency, limb salvage and survival rates were reported at 6 months. RESULTS: In all patients, crural artery occlusion was achieved with the RTP without the use of an adjunct occlusion device. Mean volume of RTP used was 0.3 ml proximally and 0.25 ml distally. Mean duration of occlusion was 14.4 ± 4.5 min, while completion of the distal anastomosis lasted 13.4 ± 4.3 min. Quality of occlusion was judged as excellent in eight cases and good in 12 cases. Residual plugs were observed in two patients and removed with an embolectomy catheter, before we amended the technique for dissolution of RTP. At 6 months, primary patency rate was 75% but limb salvage rate was 87.5%. The 30-day mortality rate was 10%. CONCLUSIONS: This study shows that RTP is safe when properly dissolved and effective to occlude small calcified arteries for completion of distal anastomosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to compare coronary magnetic resonance angiography (MRA) data obtained with different scanning methodologies, adequate visualization and presentation of the coronary MRA data need to be ensured. Furthermore, an objective quantitative comparison between images acquired with different scanning methods is desirable. To address this need, a software tool ("Soap-Bubble") that facilitates visualization and quantitative comparison of 3D volume targeted coronary MRA data was developed. In the present implementation, the user interactively specifies a curved subvolume (enclosed in the 3D coronary MRA data set) that closely encompasses the coronary arterial segments. With a 3D Delaunay triangulation and a parallel projection, this enables the simultaneous display of multiple coronary segments in one 2D representation. For objective quantitative analysis, frequently explored quantitative parameters such as signal-to-noise ratio (SNR); contrast-to-noise ratio (CNR); and vessel length, sharpness, and diameter can be assessed. The present tool supports visualization and objective, quantitative comparisons of coronary MRA data obtained with different scanning methods. The first results obtained in healthy adults and in patients with coronary artery disease are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUME Objectifs. Évaluer la prévalence de maladie coronarienne chez les patients diabétiques de type 2 asymptomatiques ou avec angor atypique selon les recommandations américaines de l'American Diabetes Association et de l'American College of Cardiology. Méthodes. Cent cinquante-quatre patients diabétiques de type 2 asymptomatiques ou avec angor atypique et présentant au minimum 2 facteurs de risque cardio-vasculaires additionnels ont été dépistés par échocardiographie de stress (71%, n=109), scintigraphie myocardique de perfusion (26%, n=40) ou l'association des 2 examens (3%, n=5). Résultats. L'échocardiographie de stress s'est révélée positive chez 16 patients (14%) et 14 ont eu une coronarographie révélant des sténoses significatives chez 12 (86%). La scintigraphie myocardique de perfusion était positive chez 16 patients (36%). Huit patients ont eu une coronarographie et 4 (50%) présentaient des sténoses significatives. Au total, 31 patients (20%) ont montré des signes d'ischémie lors de l'examen non-invasif et 15 (10%) ont présenté des sténoses significatives à la coronarographie. Les facteurs prédictifs indépendants de la maladie coronarienne étaient le tabagisme (OR 6.5, p=0.05), la microalbuminurie (OR 3.9, p=0.03), ainsi que les souffles fémoraux (OR 17.1, p=0.008). Conclusions. En suivant les recommandations américaines, un patient sur cinq présentait une ischémie lors des examens non-invasifs, tandis que 1 sur 10 avait des sténoses significatives à la coronarographie. L'analyse multivariée suggère que des marqueurs des complications micro- et macro-vasculaires en combinaison avec des facteurs de risque cardio-vasculaire classiques pourraient améliorer le pouvoir diagnostic de ces recommandations. SUMMARY Aims. We evaluated the prevalence of coronary artery disease in asymptomatic and atypical chest pain type 2 diabetic patients according to the American Diabetes Association and American College of Cardiology guidelines. Methods. Asymptomatic or atypical chest pain type 2 diabetic patients (n=154), with at least two additional cardiovascular risk factors, were screened for coronary artery disease using stress echocardiography (71%, n=109), myocardial perfusion imaging (26%, n=40) or both (3%, n=5). Results. Stress echocardiography was positive in 16 patients (14%) and 14 had a coronary angiography, revealing significant stenoses in 12 (86%). Myocardial perfusion imaging was positive in 16 patients (36%). Eight patients underwent angiography and 4 (50%) presented significant stenoses. Overall, 31 patients (20%) demonstrated signs of ischemia on non-invasive tests and 15 (10%) presented significant stenoses on coronary angiography. Independent predictors of coronary artery disease were smoking (OR 6.5, p=0.05), microalbuminuria (OR 3.9, p=0.03) and femoral murmur (OR 17.1, p=0.008). Conclusions. Following the guidelines, one in five diabetic patient presented ischemia on noninvasive tests, while one in ten presented significant coronary stenoses. Multivariate analysis suggests that adding markers of micro- and macro-vascular complications to classical cardiovascular risk factors may enhance the diagnostic efficiency of the guidelines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Deficiency of protease-activated receptor-2 (PAR2) modulates inflammation in several models of inflammatory and autoimmune disease, although the underlying mechanism(s) are not understood. PAR2 is expressed on endothelial and immune cells, and is implicated in dendritic cell (DC) differentiation. We investigated in vivo the impact of PAR2 activation on DCs and T cells in PAR2 wild-type (WT) and knockout (KO) mice using a specific PAR2 agonist peptide (AP2). PAR2 activation significantly increased the frequency of mature CD11c(high) DCs in draining lymph nodes 24 hr after AP2 administration. Furthermore, these DCs exhibited increased expression of major histocompatibility complex (MHC) class II and CD86. A significant increase in activated (CD44(+) CD62(-)) CD4(+) and CD8(+) T-cell frequencies was also observed in draining lymph nodes 48 hr after AP2 injection. No detectable change in DC or T-cell activation profiles was observed in the spleen. The influence of PAR2 signalling on antigen transport to draining lymph nodes was assessed in the context of delayed-type hypersensitivity. PAR2 WT mice that were sensitized by skin-painting with fluorescein isothiocyanate (FITC) to induce delayed-type hypersensitivity possessed elevated proportion of FITC(+) DCs in draining lymph nodes 24 hr after FITC painting when compared with PAR2 KO mice (0.95% versus 0.47% of total lymph node cells). Collectively, these results demonstrate that PAR2 signalling promotes DC trafficking to the lymph nodes and subsequent T-cell activation, and thus provides an explanation for the pro-inflammatory effect of PAR2 in animal models of inflammation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Targeted delivery of anticancer chemotherapeutics such as mitoxantrone (MTX) can significantly intensify their cytotoxic effects selectively in solid tumors such as breast cancer. In the current study, folic acid (FA)-armed and MTX-conjugated magnetic nanoparticles (MNPs) were engineered for targeted eradication of folate receptor (FR)-positive cancerous cells. Polyethylene glycol (PEG), FA and MTX were covalently conjugated onto the MNPs to engineer the PEGylated FA-MTX-MNPs. The internalization studies were performed using fluorescein isothiocyanate (FITC)-labeled FA-decorated MNPs (FA-FITC-MNPs) in both FR-positive MCF-7 cells and FR-negative A549 cells by means of fluorescence microscopy and flow cytometry. The cellular and molecular impacts of FA-MTX-MNPs were examined using trypan blue cell viability and FITC-labeled annexin V apoptosis assays and 4',6-diamidino-2-phenylindole (DAPI) staining, DNA ladder and quantitative polymerase chain reaction (qPCR) assays. RESULTS: The FR-positive MCF-7 cells showed significant internalization of the FA-FITC-MNPs, but not the FR-negative A549 cells. The FR-positive cells treated with the PEGylated FA-MTX-MNPs exhibited the IC50 values of 3 μg/mL and 1.7 μg/mL, 24 h and 48 h post-treatment, respectively. DAPI staining and DNA ladder assays revealed significant condensation of nucleus and fragmentation of genomic DNA in the FR-positive MCF-7 cells treated with the PEGylated FA-MTX-MNPs as compared to the FR-negative A549 cells. The FITC-labeled annexin V assay confirmed emergence of late apoptosis (>80%) in the FR-positive MCF-7 cells treated with the PEGylated FA-MTX-MNPs, but not in the FR-negative A549 cells. The qPCR analysis confirmed profound cytotoxic impacts via alterations of apoptosis-related genes induced by MTX-FA-MNPs in MCF-7 cells, but not in the A549 cells. CONCLUSION: Our findings evince that the engineered PEGylated FA-MTX-MNPs can be specifically taken up by the FR-positive malignant cells and effectively demolish them through up-regulation of Bcl-2-associated X protein (Bax) and Caspase 9 and down-regulation of AKt. Hence, the engineered nanosystem is proposed for simultaneous targeted imaging and therapy of various cancers overexpressing FRs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To combine weighted iterative reconstruction with self-navigated free-breathing coronary magnetic resonance angiography for retrospective reduction of respiratory motion artifacts. METHODS: One-dimensional self-navigation was improved for robust respiratory motion detection and the consistency of the acquired data was estimated on the detected motion. Based on the data consistency, the data fidelity term of iterative reconstruction was weighted to reduce the effects of respiratory motion. In vivo experiments were performed in 14 healthy volunteers and the resulting image quality of the proposed method was compared to a navigator-gated reference in terms of acquisition time, vessel length, and sharpness. RESULT: Although the sampling pattern of the proposed method contained 60% more samples with respect to the reference, the scan efficiency was improved from 39.5 ± 10.1% to 55.1 ± 9.1%. The improved self-navigation showed a high correlation to the standard navigator signal and the described weighting efficiently reduced respiratory motion artifacts. Overall, the average image quality of the proposed method was comparable to the navigator-gated reference. CONCLUSION: Self-navigated coronary magnetic resonance angiography was successfully combined with weighted iterative reconstruction to reduce the total acquisition time and efficiently suppress respiratory motion artifacts. The simplicity of the experimental setup and the promising image quality are encouraging toward future clinical evaluation. Magn Reson Med 73:1885-1895, 2015. © 2014 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The cause precipitating intracranial aneurysm rupture remains unknown in many cases. It has been observed that aneurysm ruptures are clustered in time, but the trigger mechanism remains obscure. Because solar activity has been associated with cardiovascular mortality and morbidity, we decided to study its association to aneurysm rupture in the Swiss population. METHODS: Patient data were extracted from the Swiss SOS database, at time of analysis covering 918 consecutive patients with angiography-proven aneurysmal subarachnoid hemorrhage treated at 7 Swiss neurovascular centers between January 1, 2009, and December 31, 2011. The daily rupture frequency (RF) was correlated to the absolute amount and the change in various parameters of interest representing continuous measurements of solar activity (radioflux [F10.7 index], solar proton flux, solar flare occurrence, planetary K-index/planetary A-index, Space Environment Services Center [SESC] sunspot number and sunspot area) using Poisson regression analysis. RESULTS: During the period of interest, there were 517 days without recorded aneurysm rupture. There were 398, 139, 27, 12, 1, and 1 days with 1, 2, 3, 4, 5, and 6 ruptures per day. Poisson regression analysis demonstrated a significant correlation of F10.7 index and RF (incidence rate ratio [IRR] = 1.006303; standard error (SE) 0.0013201; 95% confidence interval (CI) 1.003719-1.008894; P < 0.001), according to which every 1-unit increase of the F10.7 index increased the count for an aneurysm to rupture by 0.63%. A likewise statistically significant relationship of both the SESC sunspot number (IRR 1.003413; SE 0.0007913; 95% CI 1.001864-1.004965; P < 0.001) and the sunspot area (IRR 1.000419; SE 0.0000866; 95% CI 1.000249-1.000589; P < 0.001) emerged. All other variables analyzed showed no significant correlation with RF. CONCLUSIONS: We found greater radioflux, SESC sunspot number, and sunspot area to be associated with an increased count of aneurysm rupture. The clinical meaningfulness of this statistical association must be interpreted carefully and future studies are warranted to rule out a type-1 error.