916 resultados para digital terrain analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes the development of a method for analysis of the shape of the stretch zone surface based on parallax measurement theory and using digital image processing techniques. Accurate criteria for the definition of the boundaries of the stretch zone are established from profiles of fracture surfaces obtained from crack tip opening displacement tests on Al-7050 alloy samples. The elevation profiles behavior analysis is based on stretch zone width and height parameters. It is concluded that the geometry of the stretch zone profiles under plane strain conditions can be described by a semi-parabolic relationship. (C) Elsevier B.V., 1999. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automatic image processing and analysis technique has been developed for quantitative characterization of multi-phase materials. For the development of this technique is used the Khoros system that offers the basic morphological tools and a flexible, visual programming language. These techniques are implemented in a highly user oriented image processing environment that allows the user to adapt each step of the processing to his special requirements.To illustrate the implementation and performance of this technique, images of two different materials are processed for microstructure characterization. The result is presented through the determination of volume fraction of the different phases or precipitates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Porosity in starch consolidation casting technique is rightly related to original size and morphology of starch granules, leaving a pore structure after burning out. This work reports the results for the addition of different native potato and corn starch proportions in suspension,; with TiO(2) (rutile) powder. Gelling temperature have been defined after observation under light microscopy using a heating stage. Analysis of porous network and isolated pores have been clone from images of samples surfaces obtained by depth from focus reconstruction, revealing a qualitative correlation of pores characteristics and starches additions in suspensions, suggesting that the presence of isolated or interconnected pores can be handled by starches selection to control the amylopectin and amylose contents in slurries. Also, the analysis of porous fraction distribution shows no consistent pattern through specimens' volume according to starches in mixtures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today, the trend within the electronics industry is for the use of rapid and advanced simulation methodologies in association with synthesis toolsets. This paper presents an approach developed to support mixed-signal circuit design and analysis. The methodology proposed shows a novel approach to the problem of developing behvioural model descriptions of mixed-signal circuit topologies, by construction of a set of subsystems, that supports the automated mapping of MATLAB (R)/SINIULINK (R) models to structural VHDL-AMS descriptions. The tool developed, named (MSSV)-S-2, reads a SIMULINK (R) model file and translates it to a structural VHDL-AMS code. It also creates the file structure required to simulate the translated model in the SystemVision (TM). To validate the methodology and the developed program, the DAC08, AD7524 and AD5450 data converters were studied and initially modelled in MATLAB (R)/SIMULINK (R). The VHDL-AMS code generated automatically by (MSSV)-S-2, (MATLAB (R)/SIMULINK (R) to SystemVision (TM)), was then simulated in the SystemVision (TM). The simulation results show that the proposed approach, which is based on VHDL-AMS descriptions of the original model library elements, allows for the behavioural level simulation of complex mixed-signal circuits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article analyzes the electrical parameters of a 3-phase transmission line using a 280-m-high steel tower that has been proposed for the Amazon transmission system in Brazil. The height of the line conductors and the distance between them are intrinsically related to the longitudinal and transverse parameters of the line. Hence, an accurate study is carried out in order to show the electrical variations between a transmission line using the new technology and a conventional 3-phase 440-kV line, considering a wide range of frequencies and variable soil resistivity. First, a brief review of the fundamental theory of line parameters is presented. In addition, by using a digital line model, simulations are carried out in the time domain to analyze possible and critical over-voltage transients on the proposed line representation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study deals with cognitive competences and abilities that are relevant to selection and education regarding Information Technology (IT). These competences relate to problem solving, decision making, and practical intelligence that regard scholar and extracurricular knowledge mobilization. The research aimed to contribute for the improvement of a selection instrument, consisting of five arrays of skills (dealing with objectives and prospection), as well as the development and comprehension of those skills that are involved in IT education. This is done by means of an analysis on the selection instrument used in the first selective process that occurred at Metropole Digital an Institute at the Federal University of Rio Grande do Norte in Brazil. This was evaluated aiming to acknowledge IT education (with basic training and emphasis on Web programming and electronics). The methodology used was of quantitative method involving performance scores relating education delivery. An Anova analysis of variance was done along with descriptive analysis involving socioeconomic data that was not observed in the meaningful relations between parental instruction and student performance in the graduate course. These analyses were able to point out the importance and need of the policies for vacancy reservation on behalf of public school students. A Spearman correlation analysis was done considering the instrument selection performance in the training course. The instrument is presented as a predictor that is significantly moderate and presents a good performance in the course as a whole. A Cluster and Regression analysis was also realized in the process. The first analysis allowed finding performance groups (Clusters) that ranged from medium and inferior. The regression analysis was able to point out association amongst criterion variables and the (average performance in basic and advanced modules) and explanatory (five matrixes). Regression analysis indicated that matrix 1 and matrix 3 were pointed out as being the strongest ones. In all the above analysis, the correlation between the instrument and the course was considered moderate. Thus this can be related in some of the aspects present in the course such as emphasis on evaluation itself as well as in technical contents and practical skills (educational ones) and competences and selection skills. It is known that the mediation of technological artifact in cultural context can foster the development of skills and abilities relevant to IT training. This study provides subsidies to reflect on the adoption of selection instrument and IT training in the Institute. Thus the research offers means to achieve a interdisciplinary discussion and enriching of areas such as Psychology and Information Technology; all of which regarding competencies and skills relevant in IT training

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Besides technical and economic-organisational problems, digital preservation also faces legal issues, especially regarding copyright legislation, since all digital preservation strategies involve copying materials and/or using software which is typically copyrighted. The purpose of this paper is to ascertain the extent to which current copyright laws meet the preservation requirements of library materials..Methodology. A cross-sectional analysis of recently updated national copyright laws as well as the impact of the other two protection methods: contractual and technological.Results. Even after the latest updates current copyright legislation is almost useless for digital preservation activities since the opportunities provided by WIPO Copyright Treaty to adapt and extend copyright exceptions and limitations have been used to the full.Conclusion. We need a legislation reform that will make it possible to carry out all required copying and communication activities and software use, even if circumventing technological protection is needed. But that is not enough for licensed works. The best solution for this kind of work is to include specific clauses in the licences that facilitate preservation activities. Thus, cooperation between both parties, libraries and rights' holders, is essential.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Police officers are exposed to impact noise coming from firearms, which may cause irreversible injuries to the hearing system.Aim: To evaluate the noise exposure in shooting stands during gunfire exercises, to analyze the acoustic impact of the noise produced by the firearms and to associate it with tonal audiometry results.Study design: Cross-sectional.Materials and methods: To measure noise intensity we used a digital sound level meter, and the acoustic analysis was carried out by means of the oscillations and cochlear response curves provided by the Praat software. 30 police officers were selected (27 males and 3 females).Results: The peak level measured was 113.1 dB(C) from a .40 pistol and 116.8 dB(C) for a .38 revolver. The values obtained for oscillation and Praat was 17.9 +/- 0.3 Barks, corresponding to the rate of 4,120 and 4,580 Hz. Audiometry indicated greater hearing loss at 4,000Hz in 86.7% of the cases.Conclusion: With the acoustic analysis it was possible to show cause and effect between the main areas of energy excitation of the cochlea (Praat cochlear response curve) and the frequencies of low hearing acuity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brazil is going through the process from analogical transmission to digital transmission. This new technology, in addition to providing a high quality audio and video, also allows applications to execute on television. Equipment called Set-Top Box are needed to allow the reception of this new signal and create the appropriate environment necessary to execute applications. At first, the only way to interact with these applications is given by remote control. However, the remote control has serious usability problems when used to interact with some types of applications. This research suggests a software resources implementation capable to create a environment that allows a smartphone to interact with applications. Besides this implementation, is performed a comparative study between use remote controle and smartphones to interact with applications of digital television, taking into account parameters related to usability. After analysis of data collected by the comparative study is possible to identify which device provides an interactive experience more interesting for users

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work focuses the geological and geomorphological characterization of the inner shelf in the West Coast of the Rio Grande do Norte state, particularly the reef coral barrier offshore of Maracajaú (Maxaranguape district). If developed without the necessary concerns, tourism and entertainment activities that have been widely increased during the last five years can lead to irreversible environmental damages to the biotic and abiotic ecosystems of the region. Regarding these aspects, it is crucial the realization of a detailed study to envisage the achievement of a self-sustainable development, especially with respect to the possibilities of a rational usage of the region. This is the aim of this manuscript, which consisted of an initial stage of digital modeling of the terrain with basis on digitalization and vectorization of the Nautical map number 803 (Naval Service of Brazil, 1971). Information obtained in this phase was improved with the digital processing of small format aerial photos acquired from six flights, which were integrated to form a photomosaic of the area. The refined maps produced with the data from Nautical and aerial photo-interpretations aided to locate 9 bathymetric profiles, which provided information about the sea floor relief of the whole area. This later aided in the choosing of areas to bottom sampling that, in its turn, helped to characterize sediments present in floor of the inner shelf. Sixty-four samples collected during this work were studied by granulometrical and chemical analysis; with the later one developed in order to measure carbonate and organic matter contents. Forty-two of these samples showed carbonate content higher than 80% and organic matter in the range of 0.58% to 24.06%. With respect to grain size, these samples are in the interval between fine- to mid-grained sands. Sands with grain sizes higher than this one are also composed by carbonate carapaces such as pale yellow to red rhodolites with ellipsoidal and spheroidal shapes. During determination of the submerse features, the small format aerial photos demonstrated to be a useful methodology to aid the delineation of the sea floor topography through shallow deep waters. The bathymetry, for its turn, revealed several features at the bottom of the platform, in which the most conspicuous are undulations and morphological details of the São Roque Channel. Examination of bottom, aside from sand, yielded the identification of bivalves, ostracods, fragments of bryozoans, spikes of sponges, spines of echinoderms, operculum of gastropods and foraminifers. From the above it is concluded that the multi-methodological approach developed in this study worked efficiently, permitting the geomorphological and environmental characterization of the inner shelf of the North Maracajaú

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objectives were to separate canine seminal plasma proteins (with SDS-PAGE) and to determine the correlation between specific proteins and semen characteristics. Three ejaculates from 20 mixed-breed dogs, of unknown fertility, were collected by digital manipulation. Ejaculate volume and color, sperm motility, sperm vigor, percentage of morphologically normal spermatozoa, and membrane integrity (hypoosmotic swelling test and fluorescent staining) were assessed. For each dog, seminal plasma was pooled from all three ejaculates and proteins were separated with SDS-PAGE, using polyacrylamide concentrations of 13% and 22% in the separation gels. After staining, gel images were digitized to estimate molecular weights (MW) and integrated optical density (IOD) of each lane and of individual bands. Total seminal plasma protein concentration was 2.19 +/- 1.56 g/dL (mean +/- SD; range 1.12-5.19 g/dL). A total of 37 protein bands were identified (although no dog had all 37 bands). In the 13% gel, molecular weights ranged from 100.6 to 17.1 kDa, with four bands (49.7, 33.2, 26.4, and 19.5 kDa) present in samples from all dogs. In the 22% gel, molecular weights ranged from 15.6 to 3.6 kDa, with nine bands (15.6, 13.5, 12.7, 11.7, 10.5, 8.7, 7.8, 5.6, and 4.9 kDa) present in samples from all dogs. Combined for both gels, the majority of bands (85%) had molecular weights < 17 kDa, with B20 (15.6 kDa) in high concentrations in samples from all dogs. There were positive correlations (P <= 0.01) between two bands, 134 (67 kDa) and B5 (58.6 kDa), and sperm motility (r = 0.66 and r = 0.46), sperm vigor (r = 0.56 and r = 0.66), percentage of morphologically normal spermatozoa (r = 0.55 and r = 0.59), the hypoosmotic swelling test (r = 0.76 and r 0.68), and fluorescent staining (r = 0.56 and r = 0.59), respectively. In conclusion, 37 proteins were identified in seminal plasma; two were significantly correlated with semen characteristics. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate by means of digital radiography the behavior of the alveolar bone crest in external hexagon implants following the use of 2 different types of abutments, one for conventional cemented prosthesis and one for modified cemented prosthesis.Methods: Ten external hexagon implants (platform 4.1) were placed in 5 patients. Initial instrumentation was carried out to obtain primary stability of the temporary prostheses under immediate loading. Each patient received both abutments for conventional and modified cemented prosthesis. Standardized digital periapical radiographies were performed at times T0 (immediately after implant placement) and T1 (4 months after implant placement). A straight line was initially established from the implant platform to the distal and mesial periimplantar marginal bone tissue (immediately in contact with the implant) and measured by digital radiography, using Sidexis version 2.3 (Sirona Dental Systems GmbH, Bensheim, Germany) software. The data were submitted to paired-samples t-test analysis.Results: There was no significant difference between the conventional and modified cemented prosthesis. In both cases, t-test results were within the null hypothesis level.Conclusion: The abutment for the modified cemented prosthesis resulted in no significant radiographic difference of alveolar bone crest height, when compared with the conventional cemented prostheses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the stress distribution of platform switching implants using a photoelastic method. Three models were constructed of the photoelastic resin PL-2, with a single implant and a screw-retained implant-supported prosthesis. These models were Model A, platform 5.0 mm/abutment 4.1 mm; Model B, platform 4.1 mm/abutment 4.1 mm; and Model C, platform 5.00 mm/abutment 5.00 mm. Axial and oblique (45 degrees) loads of 100 N were applied using a Universal Testing Machine (EMIC DL 3000). Images were photographed with a digital camera and visualized with software (AdobePhotoshop) to facilitate the qualitative analysis. The highest stress concentrations were observed at the apical third of the 3 models. With the oblique load, the highest stress concentrations were located at the implant apex, opposite the load application. Stress concentrations decreased in the cervical region of Model A (platform switching), and Models A (platform switching) and C (conventional/wide-diameter) displayed similar stress magnitudes. Finally, Model B (conventional/regular diameter) displayed the highest stress concentrations of the models tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: (1) To evaluate the intraobserver agreement related to image interpretation and (2) to compare the accuracy of 100%, 200% and 400% zoomed digital images in the detection of simulated periodontal bone defects.Methods: Periodontal bone defects were created in 60 pig hemi-mandibles with slow-speed burs 0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm and 3.0 mm in diameter. 180 standardized digital radiographs were made using Schick sensor and evaluated at 100%, 200% and 400% zooming. The intraobserver agreement was estimated by Kappa statistic (kappa). For the evaluation of diagnostic accuracy receiver operating characteristic (ROC) analysis was performed followed by chi-square test to compare the areas under ROC curves according to each level of zooming.Results: For 100%, 200% and 400% zooming the intraobserver agreement was moderate (kappa = 0.48, kappa = 0.54 and kappa = 0.43, respectively) and there were similar performances in the discrimination capacity, with ROC areas of 0.8611 (95% CI: 0.7660-0.9562), 0.8600 (95% CI: 0.7659-0.9540), and 0.8368 (95% CI: 0.7346-0.9390), respectively, with no statistical significant differences (chi(2)-test; P = 0.8440).Conclusions: A moderate intraobserver agreement was observed in the classification of periodontal bone defects and the 100%, 200% and 400% zoomed digital images presented similar performances in the detection of periodontal bone defects.