979 resultados para camera motion parameters
Resumo:
This study investigates the effect of thyroid hormones on the morphology of hippocampal neurons in adult rats. Hypo- and hyperthyroidism were induced by adding 0.02% methimazole and 1% l-thyroxine, in drinking water from 40 days of age, respectively. When the rats were 89 days old their brains were removed and stained by a modified Golgi method and blood samples were collected in order to measure T4 serum levels. Neurons were selected and drawn using a camera lucida. Our results show that methimazole administration reduces the dendritic branching of the apical shafts of CA3 and CA1 pyramidal neurons mainly by increasing the distance to the first branch point in both types of neurons, and reducing branch points in the radius of 50 μm from the soma in CA1 neurons. Nevertheless, it was observed an increase of apical spine density in CA3 neurons from this group. Thyroxine reduces apical and basal tree of CA3 pyramidal neurons increasing the distance to the first branch point, reducing branch points in the radius of 50 μm from the soma and increases their apical and basal spine density. In CA1 field, thyroxine reduces the number of basal branch points. Both treatments seems to provoke alterations in the same direction reducing the dendritic branching and increasing spine density, although no significances appeared in some of the parameters analyzed. The effects are more evident in thyroxine than methimazole group; and in CA3 neurons than in CA1 neurons. In discussion it is pointed that the increase of spine density could be a mechanism to compensate the functionality reduction that can be provoke by the treatment effect on dendritic branching.
Resumo:
Työn tavoitteena oli selvittää kannatushihnapituusleikkurissa paperin rullaukseen käytettävän kannatushihnan kestoikään vaikuttavia tekijöitä ja ratkaisuja liian lyhyeen kestoikään liittyviin ongelmiin. Työssä selvitettiin ensin kannatushihnatyyppisen pituusleikkurin toimintaa ja tarkemmin sen rullausosaa ja rullausprosessin parametreja. Kannatushihnan kestoikään vaikuttavia tekijöitä on käsitelty kirjallisuuden ja kohdeyrityksessä olevan materiaalin perusteella. Seuraavaksi esitettiin ideoita kannatushihnan rakenteesta ja materiaaleista sekä vertailtiin niitä keskenään ja nykyiseen hihnan rakenteeseen. Työssä tehtiin nykyistä kannatushihnaa simuloiva kaksiulotteinen elementtimalli. Tämän elementtimallin mukaan pituusleikkurin telojen suunnassa epätasainen hihnan kuluminen johtuu hihnan paksuussuuntaisten jännitysten eroista. Hihnan kulkua arvioitiin kokeellisesti kahdella erityyppisellä hihnalla. Hihnan kulkuun eniten vaikutti esikiristysvoima, jota pienennettäessä kehänopeusero paperirullaa simuloivan kuormittavan telan ja hihnatelan välillä pieneni. Työssä löydettiin mahdollinen yhteys rullauksessa tulostietona saatavan datan sekä hihnan geometrian välille. Polyeteenivaahtomuovit ovat kitkansa puolesta lupaavia hihnan kitkapinnoitteen materiaaliksi. Toisaalta polyeteenivaahtomuovien mekaanisia ominaisuuksia ei juuri tunneta, eikä niitä ole käytetty kulutuskestoa vaativissa sovelluksissa. Hihnan ulkopinnan kulumismekanismia ei täysin tunneta.
Resumo:
OBJECTIVE: Electrolytes handling by the kidney is essential for volume and blood pressure (BP) homeostasis but their distribution and heritability are not well described. We estimated the heritability of kidney function as well as of serum and urine concentrations, renal clearances and fractional excretions for sodium, chloride, potassium, calcium, phosphate and magnesium in a Swiss population-based study. DESIGN AND METHOD: Nuclear families were randomly selected from the general population in Switzerland. We estimated glomerular filtration rate (eGFR) using the CKD-EPI and MDRD equations. Urine was collected separately during day and night over 24-hour. We used the ASSOC program (S.A.G.E.) to estimate narrow sense heritability, including as covariates in the model: age, sex, body mass index and study center. RESULTS: The 1128 participants (537 men and 591 women from 273 families), had mean (sd) age of 47.4(17.5) years, body mass index of 25.0 (4.5) kg/m2 and CKD-EPI of 98.0(18.5) mL/min/1.73 m2. Heritability estimates (SE) were 46.0% (0.06), 48.0% (0.06) and 18.0% (0.06) for CKD-EPI, MDRD and 24-hour creatinine clearance (P < 0.05), respectively. Heritability [SE] of serum concentration was highest for calcium (37%[0.06]) and lowest for sodium (13%[0.05]). Heritabilities [SE] of 24-h urine concentrations and excretions, and of fractional excretions were highest for calcium (51%[0.06], 44%[0.06] and 51%[0.06], respectively) and lowest for potassium (11%[0.05], 10%[0.05] and 16%[0.06], respectively). All results were statistically different from zero.(Figure is included in full-text article.) CONCLUSIONS: : Serum and urine levels, urinary excretions and renal handling of electrolytes, particularly calcium, are heritable in the general adult population. Identifying genetic variants involved in electrolytes homeostasis may provide useful insight into the pathophysiological mechanisms involved in common chronic diseases such as kidney diseases, hypertension and diabetes.
Resumo:
Tämän diplomityön tavoitteena oli sekundäärisen esiflotaation optimointi Stora Enso Sachsen GmbH:n tehtaalla. Optimoinnin muuttujana käytettiin vaahdon määrää ja optimointiparametreinä ISO-vaaleutta, saantoja sekä tuhkapitoisuutta. Lisäksi tutkittiin flotaatiosakeuden vaikutusta myös muihin tehtaan flotaatioprosesseihin. Kirjallisuusosassa tarkasteltiin flotaatiotapahtumaa, poistettavien partikkeleiden ja ilmakuplien kontaktia, vaahdon muodostumista sekä tärkeimpiä käytössä olevia siistausflotaattoreiden laiteratkaisuja. Kokeellisessa osassa tutkittiin flotaatiosakeuden pienetämisen vaikutuksia tehtaan flotaatioprosesseihin tuhkapitoisuuden, ISO-vaaleuden, valon sironta- ja valon absorpiokerrointen kannalta. Sekundäärisen esiflotaation optimonti suoritettiin muuttamalla vaahdon määrää kolmella erilaisella injektorin koolla, (8 mm, 10 mm ja 13 mm), joista keskimmäinen kasvattaa 30 % massan tilavuusvirtaa ilmapitoisuuden muodossa. Optimonnin tarkoituksena oli kasvattaa hyväksytyn massajakeen ISO-vaaleutta, sekä kasvattaa kuitu- ja kokonaissaantoa sekundäärisessä esiflotaatiossa. Flotaatiosakeuden pienentämisellä oli edullisia vaikutuksia ISO-vaaleuteen ja valon sirontakertoimeen kussakin flotaatiossa. Tuhkapitoisuus pieneni sekundäärisissä flotaatioissa enemmän sakeuden ollessa pienempi, kun taas primäärisissä flotaatiossa vaikutus oli päinvastainen. Valon absorptiokerroin parani jälkiflotaatioissa alhaisemmalla sakeudella, kun taas esiflotaatioissa vaikutus oli päinvastainen. Sekundäärisen esiflotaation optimoinnin tuloksena oli lähes 5 % parempi ISO-vaaleus hyväksytyssä massajakeessa. Kokonaissaanto parani optimoinnin myötä 5 % ja kuitusaanto 2 %. Saantojen nousu tuottaa vuosittaisia säästöjä siistauslaitoksen tuotantokapasiteetin noustessa 0,5 %. Tämän lisäksi sekundäärisessä esiflotaatiossa rejektoituvan massavirran pienentyminen tuottaa lisäsäästöjä tehtaan voimalaitoksella.
Resumo:
Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.
Resumo:
We examine the phenomenon of hydrodynamic-induced cooperativity for pairs of flagellated micro-organism swimmers, of which spermatozoa cells are an example. We consider semiflexible swimmers, where inextensible filaments are driven by an internal intrinsic force and torque-free mechanism (intrinsic swimmers). The velocity gain for swimming cooperatively, which depends on both the geometry and the driving, develops as a result of the near-field coupling of bending and hydrodynamic stresses. We identify the regimes where hydrodynamic cooperativity is advantageous and quantify the change in efficiency. When the filaments' axes are parallel, hydrodynamic interaction induces a directional instability that causes semiflexible swimmers that profit from swimming together to move apart from each other. Biologically, this implies that flagella need to select different synchronized collective states and to compensate for directional instabilities (e.g., by binding) in order to profit from swimming together. By analyzing the cooperative motion of pairs of externally actuated filaments, we assess the impact that stress distribution along the filaments has on their collective displacements.
Resumo:
Parkinson disease (PD) is associated with a clinical course of variable duration, severity, and a combination of motor and non-motor features. Recent PD research has focused primarily on etiology rather than clinical progression and long-term outcomes. For the PD patient, caregivers, and clinicians, information on expected clinical progression and long-term outcomes is of great importance. Today, it remains largely unknown what factors influence long-term clinical progression and outcomes in PD; recent data indicate that the factors that increase the risk to develop PD differ, at least partly, from those that accelerate clinical progression and lead to worse outcomes. Prospective studies will be required to identify factors that influence progression and outcome. We suggest that data for such studies is collected during routine office visits in order to guarantee high external validity of such research. We report here the results of a consensus meeting of international movement disorder experts from the Genetic Epidemiology of Parkinson's Disease (GEO-PD) consortium, who convened to define which long-term outcomes are of interest to patients, caregivers and clinicians, and what is presently known about environmental or genetic factors influencing clinical progression or long-term outcomes in PD. We propose a panel of rating scales that collects a significant amount of phenotypic information, can be performed in the routine office visit and allows international standardization. Research into the progression and long-term outcomes of PD aims at providing individual prognostic information early, adapting treatment choices, and taking specific measures to provide care optimized to the individual patient's needs.
Resumo:
This paper discusses the levels of degradation of some co- and byproducts of the food chain intended for feed uses. As the first part of a research project, 'Feeding Fats Safety', financed by the sixth Framework Programme-EC, a total of 123 samples were collected from 10 European countries, corresponding to fat co- and byproducts such as animal fats, fish oils, acid oils from refining, recycled cooking oils, and other. Several composition and degradation parameters (moisture, acid value, diacylglycerols and monoacylglycerols, peroxides, secondary oxidation products, polymers of triacylglycerols, fatty acid composition, tocopherols, and tocotrienols) were evaluated. These findings led to the conclusion that some fat by- and coproducts, such as fish oils, lecithins, and acid oils, show poor, nonstandardized quality and that production processes need to be greatly improved. Conclusions are also put forward about the applicability and utility of each analytical parameter for characterization and quality control.
Resumo:
The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.
Resumo:
The present study proposes a method based on ski fixed inertial sensors to automatically compute spatio-temporal parameters (phase durations, cycle speed and cycle length) for the diagonal stride in classical cross-country skiing. The proposed system was validated against a marker-based motion capture system during indoor treadmill skiing. Skiing movement of 10 junior to world-cup athletes was measured for four different conditions. The accuracy (i.e. median error) and precision (i.e. interquartile range of error) of the system was below 6ms for cycle duration and ski thrust duration and below 35ms for pole push duration. Cycle speed precision (accuracy) was below 0.1m/s (0.005m/s) and cycle length precision (accuracy) was below 0.15m (0.005m). The system was sensitive to changes of conditions and was accurate enough to detect significant differences reported in previous studies. Since capture volume is not limited and setup is simple, the system would be well suited for outdoor measurements on snow.
Resumo:
Intracranial aneurysms are a common pathologic condition with a potential severe complication: rupture. Effective treatment options exist, neurosurgical clipping and endovascular techniques, but guidelines for treatment are unclear and focus mainly on patient age, aneurysm size, and localization. New criteria to define the risk of rupture are needed to refine these guidelines. One potential candidate is aneurysm wall motion, known to be associated with rupture but difficult to detect and quantify. We review what is known about the association between aneurysm wall motion and rupture, which structural changes may explain wall motion patterns, and available imaging techniques able to analyze wall motion.
Resumo:
PURPOSE: The impacts of humeral offset and stem design after reverse shoulder arthroplasty (RSA) have not been well-studied, particularly with regard to newer stems which have a lower humeral inclination. The purpose of this study was to analyze the effect of different humeral stem designs on range of motion and humeral position following RSA. METHODS: Using a three-dimensional computer model of RSA, a traditional inlay Grammont stem was compared to a short curved onlay stem with different inclinations (155°, 145°, 135°) and offset (lateralised vs medialised). Humeral offset, the acromiohumeral distance (AHD), and range of motion were evaluated for each configuration. RESULTS: Altering stem design led to a nearly 7-mm change in humeral offset and 4 mm in the AHD. Different inclinations of the onlay stems had little influence on humeral offset and larger influence on decreasing the AHD. There was a 10° decrease in abduction and a 5° increase in adduction between an inlay Grammont design and an onlay design with the same inclination. Compared to the 155° model, the 135° model improved adduction by 28°, extension by 24° and external rotation of the elbow at the side by 15°, but led to a decrease in abduction of 9°. When the tray was placed medially, on the 145° model, a 9° loss of abduction was observed. CONCLUSIONS: With varus inclination prostheses (135° and 145°), elevation remains unchanged, abduction slightly decreases, but a dramatic improvement in adduction, extension and external rotation with the elbow at the side are observed.
Resumo:
PURPOSE: To meta-analyze the literature on the clinical performance of Class V restorations to assess the factors that influence retention, marginal integrity, and marginal discoloration of cervical lesions restored with composite resins, glass-ionomer-cement-based materials [glass-ionomer cement (GIC) and resin-modified glass ionomers (RMGICs)], and polyacid-modified resin composites (PMRC). MATERIALS AND METHODS: The English literature was searched (MEDLINE and SCOPUS) for prospective clinical trials on cervical restorations with an observation period of at least 18 months. The studies had to report about retention, marginal discoloration, marginal integrity, and marginal caries and include a description of the operative technique (beveling of enamel, roughening of dentin, type of isolation). Eighty-one studies involving 185 experiments for 47 adhesives matched the inclusion criteria. The statistical analysis was carried out by using the following linear mixed model: log (-log (Y /100)) = β + α log(T ) + error with β = log(λ), where β is a summary measure of the non-linear deterioration occurring in each experiment, including a random study effect. RESULTS: On average, 12.3% of the cervical restorations were lost, 27.9% exhibited marginal discoloration, and 34.6% exhibited deterioration of marginal integrity after 5 years. The calculation of the clinical index was 17.4% of failures after 5 years and 32.3% after 8 years. A higher variability was found for retention loss and marginal discoloration. Hardly any secondary caries lesions were detected, even in the experiments with a follow-up time longer than 8 years. Restorations placed using rubber-dam in teeth whose dentin was roughened showed a statistically significantly higher retention rate than those placed in teeth with unprepared dentin or without rubber-dam (p < 0.05). However, enamel beveling had no influence on any of the examined variables. Significant differences were found between pairs of adhesive systems and also between pairs of classes of adhesive systems. One-step self-etching had a significantly worse clinically index than two-step self-etching and three-step etch-and-rinse (p = 0.026 and p = 0.002, respectively). CONCLUSION: The clinical performance is significantly influenced by the type of adhesive system and/or the adhesive class to which the system belongs. Whether the dentin/enamel is roughened or not and whether rubberdam isolation is used or not also significantly influenced the clinical performance. Composite resin restorations placed with two-step self-etching and three-step etch-and-rinse adhesive systems should be preferred over onestep self-etching adhesive systems, GIC-based materials, and PMRCs.
Resumo:
We propose using the affinity propagation (AP) clustering algorithm for detecting multiple disjoint shoals, and we present an extension of AP, denoted by STAP, that can be applied to shoals that fusion and fission across time. STAP incorporates into AP a soft temporal constraint that takes cluster dynamics into account, encouraging partitions obtained at successive time steps to be consistent with each other. We explore how STAP performs under different settings of its parameters (strength of the temporal constraint, preferences, and distance metric) by applying the algorithm to simulated sequences of collective coordinated motion. We study the validity of STAP by comparing its results to partitioning of the same data obtained from human observers in a controlled experiment. We observe that, under specific circumstances, AP yields partitions that agree quite closely with the ones made by human observers. We conclude that using the STAP algorithm with appropriate parameter settings is an appealing approach for detecting shoal fusion-fission dynamics.