978 resultados para alternative assessment
Resumo:
ABSTRACT OBJECTIVE To describe methods and challenges faced in the health impact assessment of vaccination programs, focusing on the pneumococcal conjugate and rotavirus vaccines in Latin America and the Caribbean. METHODS For this narrative review, we searched for the terms "rotavirus", "pneumococcal", "conjugate vaccine", "vaccination", "program", and "impact" in the databases Medline and LILACS. The search was extended to the grey literature in Google Scholar. No limits were defined for publication year. Original articles on the health impact assessment of pneumococcal and rotavirus vaccination programs in Latin America and the Caribbean in English, Spanish or Portuguese were included. RESULTS We identified 207 articles. After removing duplicates and assessing eligibility, we reviewed 33 studies, 25 focusing on rotavirus and eight on pneumococcal vaccination programs. The most frequent studies were ecological, with time series analysis or comparing pre- and post-vaccination periods. The main data sources were: health information systems; population-, sentinel- or laboratory-based surveillance systems; statistics reports; and medical records from one or few health care services. Few studies used primary data. Hospitalization and death were the main outcomes assessed. CONCLUSIONS Over the last years, a significant number of health impact assessments of pneumococcal and rotavirus vaccination programs have been conducted in Latin America and the Caribbean. These studies were carried out few years after the programs were implemented, meet the basic methodological requirements and suggest positive health impact. Future assessments should consider methodological issues and challenges arisen in these first studies conducted in the region.
Resumo:
ABSTRACT OBJECTIVE To assess the internal consistency of the measurements of the Self-Reporting Questionnaire (SRQ-20) in different occupational groups. METHODS A validation study was conducted with data from four surveys with groups of workers, using similar methods. A total of 9,959 workers were studied. In all surveys, the common mental disorders were assessed via SRQ-20. The internal consistency considered the items belonging to dimensions extracted by tetrachoric factor analysis for each study. Item homogeneity assessment compared estimates of Cronbach’s alpha (KD-20), the alpha applied to a tetrachoric correlation matrix and stratified Cronbach’s alpha. RESULTS The SRQ-20 dimensions showed adequate values, considering the reference parameters. The internal consistency of the instrument items, assessed by stratified Cronbach’s alpha, was high (> 0.80) in the four studies. CONCLUSIONS The SRQ-20 showed good internal consistency in the professional categories evaluated. However, there is still a need for studies using alternative methods and additional information able to refine the accuracy of latent variable measurement instruments, as in the case of common mental disorders.
Resumo:
ABSTRACT OBJECTIVE To examine whether the level of complexity of the services structure and sociodemographic and clinical characteristics of patients in hemodialysis are associated with the prevalence of poor health self-assessment. METHODS In this cross-sectional study, we evaluated 1,621 patients with chronic terminal kidney disease on hemodialysis accompanied in 81 dialysis services in the Brazilian Unified Health System in 2007. Sampling was performed by conglomerate in two stages and a structured questionnaire was applied to participants. Multilevel multiple logistic regression was used for data analysis. RESULTS The prevalence of poor health self-assessment was of 54.5%, and in multivariable analysis it was associated with the following variables: increasing age (OR = 1.02; 95%CI 1.01–1.02), separated or divorced marital status (OR = 0.62; 95%CI 0.34–0.88), having 12 years or more of study (OR = 0.51; 95%CI 0.37–0.71), spending more than 60 minutes in commuting between home and the dialysis service (OR = 1.80; 95%CI 1.29–2.51), having three or more self-referred diseases (OR = 2.20; 95%CI 1.33–3.62), and reporting some (OR = 2.17; 95%CI 1.66–2.84) or a lot of (OR = 2.74; 95%CI 2.04–3.68) trouble falling asleep. Individuals in treatment in dialysis services with the highest level of complexity in the structure presented less chance of performing a self-assessment of their health as bad (OR = 0.59; 95%CI 0.42–0.84). CONCLUSIONS We showed poor health self-assessment is associated with age, years of formal education, marital status, home commuting time to the dialysis service, number of self-referred diseases, report of trouble sleeping, and also with the level of complexity of the structure of health services. Acknowledging these factors can contribute to the development of strategies to improve the health of patients in hemodialysis in the Brazilian Unified Health System.
Resumo:
A new data set of daily gridded observations of precipitation, computed from over 400 stations in Portugal, is used to assess the performance of 12 regional climate models at 25 km resolution, from the ENSEMBLES set, all forced by ERA-40 boundary conditions, for the 1961-2000 period. Standard point error statistics, calculated from grid point and basin aggregated data, and precipitation related climate indices are used to analyze the performance of the different models in representing the main spatial and temporal features of the regional climate, and its extreme events. As a whole, the ENSEMBLES models are found to achieve a good representation of those features, with good spatial correlations with observations. There is a small but relevant negative bias in precipitation, especially in the driest months, leading to systematic errors in related climate indices. The underprediction of precipitation occurs in most percentiles, although this deficiency is partially corrected at the basin level. Interestingly, some of the conclusions concerning the performance of the models are different of what has been found for the contiguous territory of Spain; in particular, ENSEMBLES models appear too dry over Portugal and too wet over Spain. Finally, models behave quite differently in the simulation of some important aspects of local climate, from the mean climatology to high precipitation regimes in localized mountain ranges and in the subsequent drier regions.
Resumo:
Conferência: CONTROLO’2012 - 16-18 July 2012 - Funchal
Resumo:
In the field of appearance-based robot localization, the mainstream approach uses a quantized representation of local image features. An alternative strategy is the exploitation of raw feature descriptors, thus avoiding approximations due to quantization. In this work, the quantized and non-quantized representations are compared with respect to their discriminativity, in the context of the robot global localization problem. Having demonstrated the advantages of the non-quantized representation, the paper proposes mechanisms to reduce the computational burden this approach would carry, when applied in its simplest form. This reduction is achieved through a hierarchical strategy which gradually discards candidate locations and by exploring two simplifying assumptions about the training data. The potential of the non-quantized representation is exploited by resorting to the entropy-discriminativity relation. The idea behind this approach is that the non-quantized representation facilitates the assessment of the distinctiveness of features, through the entropy measure. Building on this finding, the robustness of the localization system is enhanced by modulating the importance of features according to the entropy measure. Experimental results support the effectiveness of this approach, as well as the validity of the proposed computation reduction methods.
Resumo:
The aim of this study was the assessment of exposure to ultrafine in the urban environment of Lisbon, Portugal, due to automobile traffic, and consisted of the determination of deposited alveolar surface area in an avenue leading to the town center during late spring. This study revealed differentiated patterns for weekdays and weekends, which could be related with the fluxes of automobile traffic. During a typical week, ultrafine particles alveolar deposited surface area varied between 35.0 and 89.2 mu m(2)/cm(3), which is comparable with levels reported for other towns such in Germany and the United States. These measurements were also complemented by measuring the electrical mobility diameter (varying from 18.3 to 128.3 nm) and number of particles that showed higher values than those previously reported for Madrid and Brisbane. Also, electron microscopy showed that the collected particles were composed of carbonaceous agglomerates, typical of particles emitted by the exhaustion of diesel vehicles. Implications: The approach of this study considers the measurement of surface deposited alveolar area of particles in the outdoor urban environment of Lisbon, Portugal. This type of measurements has not been done so far. Only particulate matter with aerodynamic diameters <2.5 (PM2.5) and >10 (PM10) mu m have been measured in outdoor environments and the levels found cannot be found responsible for all the observed health effects. Therefore, the exposure to nano- and ultrafine particles has not been assessed systematically, and several authors consider this as a real knowledge gap and claim for data such as these that will allow for deriving better and more comprehensive epidemiologic studies. Nanoparticle surface area monitor (NSAM) equipments are recent ones and their use has been limited to indoor atmospheres. However, as this study shows, NSAM is a very powerful tool for outdoor environments also. As most lung diseases are, in fact, related to deposition of the alveolar region of the lung, the metric used in this study is the ideal one.
Resumo:
Apresentação no âmbito da Dissertação de Mestrado Orientador: Doutora Alcina Dias
Resumo:
Thesis submitted to the Faculdade de Ciências e Tecnologia to obtain the Master’s degree in Environmental Engineering, profile in Ecological Engineering
Resumo:
Seventy three children (6-15 years) and 75 adults (18-47 years) with active schistosomiasis mansoni were treated with oltipraz. All cases had at least 100 eggs per gram of feces as determined by the Kato-Katz technique. Children and adults were divided in two groups receiving respectively 25 or 30 mg/kg, as a single oral dose. Clinical examination, laboratories tests (haemogram, urinalysis, hepatic and kidney functions tests, glycemia, cholesterol, triglicerides, lipoprotein HLD and LDL) and ECG were performed before, 3 or 7 days and 1 month after treatment. Parasitological control with 3 daily coprological examinations, was done on the 1st, 3rd j 6th month after drug administration. Giddiness, somnolence, headache, nausea, vomiting and abdominal distress were the most frequent side effects. Pain in the finger tips that need further investigations also occurred. No significant alteration in complementary tests were observed, whereas eosinophilia 1 month after treatment was detected, probably indicating worm death. The cure rate in children was 81.8% and 74.2% with 25 and 30 mg/kg respectively, and in adults 75.0% and 81.2% of the patients. No statistical significant difference was observed between cure rate and side effects at different dosages employed, neither between adults nor children. In all groups the percentage of egg reduction in feces in the non cured patients was higher than 96.0%. Further investigation with this new compound is necessary to accomplish the real value of oltipraz in the schistosomiasis chemotherapy.
Resumo:
Tese de Mestrado em Engenharia Informática
Resumo:
The aim of this study was to contribute to the assessment of exposure levels of ultrafine particles in the urban environment of Lisbon, Portugal, due to automobile traffic, by monitoring lung deposited alveolar surface area (resulting from exposure to ultrafine particles) in a major avenue leading to the town center during late spring, as well as in indoor buildings facing it. Data revealed differentiated patterns for week days and weekends, consistent with PM2.5 and PM10 patterns currently monitored by air quality stations in Lisbon. The observed ultrafine particulate levels may be directly correlated with fluxes in automobile traffic. During a typical week, amounts of ultrafine particles per alveolar deposited surface area varied between 35 and 89.2 mu m2/cm3, which are comparable with levels reported for other towns in Germany and the United States. The measured values allowed for determination of the number of ultrafine particles per cubic centimeter, which are comparable to levels reported for Madrid and Brisbane. In what concerns outdoor/indoor levels, we observed higher levels (32 to 63%) outdoors, which is somewhat lower than levels observed in houses in Ontario.
Resumo:
The increasing integration of wind energy in power systems can be responsible for the occurrence of over-generation, especially during the off-peak periods. This paper presents a dedicated methodology to identify and quantify the occurrence of this over-generation and to evaluate some of the solutions that can be adopted to mitigate this problem. The methodology is applied to the Portuguese power system, in which the wind energy is expected to represent more than 25% of the installed capacity in a near future. The results show that the pumped-hydro units will not provide enough energy storage capacity and, therefore, wind curtailments are expected to occur in the Portuguese system. Additional energy storage devices can be implemented to offset the wind energy curtailments. However, the investment analysis performed show that they are not economically viable, due to the present high capital costs involved.
Resumo:
Portugal, as well as the Mediterranean basin, is favorable to the occurrence of forest fires. In this work a statistical analysis was carried out based on the official information, considering the forest fires occurrences and the corresponding burned area for each of the districts of the mainland Portugal, between 1996 and 2010. Concerning to the forest fires occurrence it was possible to identify three main regions in mainland Portugal, while the burned area can be characterized in two main regions. Associations between districts and years are different in the two approaches. The results obtained provide a synthetic analysis of the phenomenon of forest fires in continental Portugal, based on all the official information available to date.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Energia e Bioenergia