951 resultados para acrylic


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the bond strength between two types of acrylic resin teeth and a microwave denture base resin after immersion in disinfectant solutions for 180 days. Eighty specimens made of acrylic resin teeth (Biotone and Biotone IPN) attached to a microwave polymerized denture base resin (Nature-Cryl MC) were divided into eight groups (n = 10) according to the treatment (distilled water-control, 2% chlorhexidine digluconate, 1% sodium hypochlorite and sodium perborate solution-Corega Tabs). The shear strength tests (MPa) were carried out using a universal testing machine with a 0.5 mm/min speed. Data analysis was performed using ANOVA and multiple comparison Student-Newman-Keuls post hoc test (α = 0.05). Biotone IPN showed similar results among the groups (distilled water, 8.25 ± 1.81 MPa; chlorhexidine, 7.81 ± 3.34 MPa; hypochlorite, 7.75 ± 3.72 MPa; and Corega Tabs, 7.58 ± 2.27 MPa, whereas Biotone showed significantly lower shear bond strength values for the groups immersed in Corega Tabs (5.25 ± 3.27 MPa) and chlorhexidine (6.08 ± 2.35 MPa). Soaking the dentures in 1% sodium hypochlorite could be recommended as a disinfectant solution for dentures fabricated with conventional acrylic resin denture teeth and microwave denture base resin. For dentures fabricated with IPN teeth and microwave denture base resin, all the soaking solutions evaluated in this study could be suggested to denture wearers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents an efficient method for the preparation of magnetic nanoparticles modified with molecularly imprinted polymers (Mag-MIP) through core-shell method for the determination of biotin in milk food samples. The functional monomer acrylic acid was selected from molecular modeling, EGDMA was used as cross-linking monomer and AIBN as radical initiator. The Mag-MIP and Mag-NIP were characterized by FTIR, magnetic hysteresis, XRD, SEM and N2-sorption measurements. The capacity of Mag-MIP for biotin adsorption, its kinetics and selectivity were studied in detail. The adsorption data was well described by Freundlich isotherm model with adsorption equilibrium constant (KF) of 1.46 mL g(-1). The selectivity experiments revealed that prepared Mag-MIP had higher selectivity toward biotin compared to other molecules with different chemical structure. The material was successfully applied for the determination of biotin in diverse milk samples using HPLC for quantification of the analyte, obtaining the mean value of 87.4% recovery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect in the gingival tissue of four distinctive types of relationships between the major conector and the gingival margin was investigated in eight subjects in association with the experimental gingivitis model. The subjects wore appliances constructed in acrylic resin (retained by means of embrasure hooks) throughout the day an night, except during meals. After the appliances had been placed, the subjects were abstained from any oral hygiene for twenty-one days. Records of the Plaque Index, Gingival Index and probing deplh were taken at baseline and at each week. Data showed that there was a small increase in the Plaque Index and Gingival Index for the four areas and that the degree of inflammation of the covered areas was higher in the area without relief

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The technique proposed aims at reducing the weight of individualized ample ocular prostheses using acrylic resins as well as simplifying laboratory procedure. For that, prefabricated hollow spheres made of plastic material, were inserted in the sclera. The average weights of the solid conventional sclera (5.30g) and those of the respective prefabricated plastic ones (3.91g) were compared. The weight reduction was significative with a confidence interval of 95% by the Student t test. ln addition, for illustration purpose, the technique was applied to patients in the ward of the Maxillofacial Prostheses Dicipline of the Dentistry School in the Campus of São José dos Campos - UNESP, having each patient received a solid prosthesis and a hollow prefabricated one made of plastic material. It has been concluded that the prostheses material spheres were inserted are lighter than the ones which received solid spheres; furthermore, thr technique is viable for ample anophtalmic cavities and requires few sessions

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering the importance of the esthetic and the adequate register of vertical dimension (VD) to the oral rehabilitation, this study had as aims the analysis and comparison of two methods to get VD (Pleasure and Willis), functional space (FE), acquisition and correlation of facial and dental measurements. To do this, rest (RVD) and occlusal vertical dimension (OVD) and FE were achieved from the 30 students of the Federal University of Goias College of Dentistry. Following that, dental measurements of height and of the superior central incisors (SCI) and canine distance were registered. A facial analysis was performed to get the intercomissura, interalar, interpupilar, intercantal distance, besides register parameters as coincidence of dental and facial line, type of smile, face and SCI forms, and mastication type. The collected data were tabulated, compared by medias and standard deviations, and submitted to non-parametrical statistical analysis of Kruskal-Wallis and .Mann-Whitney with 5% of probability. The results doesn’t indicated statistical significant difference between FE of the two techniques. The measures of facial analysis are comparable with literature published data’s, but can’t be used as a parameter to the selection of intercanine distance. In 56.7% of the cases, there were coincidences of face and SCI forms, which could be a viable parameter in the selection of acrylic resin artificial tooth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: This study aimed to assess dimensional changes in acrylic resin base and artificial teeth position after water storage and thermocycling using computer graphics measurements. Methods: Twenty-four waxed replicas were obtained from a previous upper complete denture. For linear measurements, points in cusps tips of left central incisor and second premolars and molars were marked in one of the prostheses with graphite and transferred to the others using an acrylic resin guide. The prostheses were scanned after waxing, polymerization and treatments and the images were exported to “AutoCad 2002 Today®” software for measurements. Results: There was no statistically significant difference in changes of each segment for each group and between the phases evaluated after polymerization and thermocycling. In groups I and III, the values after polymerization are higher than those after treatment, which suggests shrinkage while the prostheses in group II have expanded. Conclusion: The three groups exhibited artificial teeth movement after tests in comparison to the polymerized prosthesis. The prostheses submitted to water storage in kiln at 36ºC during seven days showed different behavior than the other groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Risk of mechanical injuries contraindicate brushing and elect chemical agents as appropriate for daily cleaning of dentures relined with resilient materials. It was evaluated the effect of denture cleansers on the wettability of denture relining material (Dentusoft, Dental Medrano). We used 20 discs of acrylic resin thermoactivated VipiCril ® with 30mm diameter and 4mm thick, covered by 2mm Dentusoft ®. Divided into 4grupos were stored in artificial saliva at 37 +1 º C for 30 days, immersed daily for 15minutes in distilled water (GI), Corega ® Tabs (GII), a solution of sodium bicarbonate (GIII) or solution of sodium hypochlorite (GIV) after which, on the soft liner were poured 2 ml of type IV gypsum (Durone IV, Dentsply). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to analysis, showed non-normal distribution, opting for non-parametric test. Kruskal Wallis test performed at 5% significance, there was statistical difference between the groups with lower average contact angle for GII. It was concluded that the chemical cleaning Corega Tabs ® allowed a better adaptation of relining the gypsum studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The lateral movement presents a combination of lateral condylar and protrusive displacement on the non-working side. The objective os this study was to check the differences in the adjustment of the semiadjustable articulator starting from two different initial positions, centric relation an intercuspal position using positional records of rotusion and lateral movements in acrylic resin for the adjustment of condylar guidance as for ennett Angle. Twenty pacients dentate and assintomatic were recruited and their adjustment were performed in the semiadjustable articulator checking the differences among the studied groups, not finding statistically significant differences. Concludes that, in semiadjustable articulator adjustment, starting the montage in centric relation or intercuspal position, the results obtained for the condylar guidande and Bennett Angle aren´t statistically diferents, as well there is no difference in condylar guidance adjustment using lateral or protrusive records.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alveolar bone resorption is continuous throughout the life of edentulous patients, the prosthesis mismatch can generate during speech and chewing. An alternative to this would be to destabilize the denture reline, a maneuver which aims to readjust the denture base to the rim by the addition of a plastic film to the inner surface of the prosthesis material. This procedure may be direct, when performed in the clinic, or indirect when made in prosthetic laboratory. The aim this study is to demonstrate the technical of two reline for denture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The immediate complete denture is a prostheses made prior to teeth extraction, that aims to re-establish the patient aesthetics and function immediately after the removal of the remaining teeth. The objective of this paper is to report the technical procedures during the manufacture of immediate prosthesis. The study reports the clinical steps prior to teeth extraction as well as the surgical and maintenance procedures. The immediate complete denture is a viable rehabilitation method, especially to restore patients’ self-esteem, aesthetics and function promptly. An accurate planning and manufactory beholds better results

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eye loss results on facial asymmetry compromising its aesthetics. Ocular prostheses are important to re-establish aesthetics; protect the anophthalmic cavity; recover function such as the redirection of lachrymatory liquid; and reintegrate the patient to society. The aim of this study was to describe a case report, demonstrating clinical and laboratorial procedures for confection of ocular prostheses and highlighting their advantages. A female patient was afflicted by toxoplasmosis, which led to the loss of her eye. An eye visceration was performed. The patient reported no previous use of ocular prosthesis. A PMMA ocular prosthesis was manufactured restoring patient’s aesthetic and facial contour. The patient was satisfied with the treatment. Therefore the present study has shown that PMMA ocular prosthesis is able to restore facial aesthetics and can be a safe and satisfactory alternative for patients that have lost their eyes due to toxoplasmosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: the aim of this study was to evaluate the influence of occlusal veneering material in single fixed implant-supported crowns through the 3-D finite element method. Material and methods: Four models were fabricated using the Rhinoceros 4.0, SolidWorks, and InVesalius softwares. Each model represented a block of mandibular bone with an external hexagon implant of 5 mm x 10 mm and different veneering materials including NiCr (1), porcelain (2), composite resin (3), and acrylic resin (4). An axial load of 200 N and an oblique load of 100 N were applied. Results: model (2) with porcelain veneering presented a lower stress concentration for the NiCr framework, followed by the composite resin and acrylic resin. The stress distribution to the implant and bone tissue was similar for all models. Conclusions: there is no difference of stress distribution to the implant and supporting structures by varying the veneering material of a single implant-supported prosthesis.