949 resultados para Wearable, Internet-of-Things, Controllo accessi, Bluetooth, Apple Watch


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A trial was conducted on Latossol Vermelho Escuro Orto (Orthox) at Buri, State of São Paulo, Brazil. The material was collected from 'Ohio Beauty¹ and 'Brasil¹ apples trees grafted on 'Doucin'; the trees were 3-4, 4-5 and 6-7 years old. The authors concluded that at the dormant period differen ces were observed on the dry matter production as well on the nutrients exported by the leaves and branches of the two varieties. Branches exported higher amounts of P, Ca, B, Cu and Zn. Larger quantities of N, P and Mn were exported by the 1 eaves.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

On an apple grove situated at Buri, State of São Paulo, fruits were collected from trees 1-2; 3-4; 4-5, and 6 - 7 years old. The fruits were analysed for N, P, K, Ca, Mg, S, B, Cu, Fe, Mn and Zn. The authors concluded: a) the concentrations of the nutrients in the fruits differ according to the variety, age of the tree and age of the fruit; b) the concentrations of nutrients decrease with aging of the fruits; c) the concentrations of the macronutrients obey the following order: N>K>P>Ca>S> Mg; d) for the micronutrients, the following order was ob -served: Fe > B > Mn > Cu > Zn.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aquest projecte intenta cobrir les necessitats que genera una empresa nova que vol vendre loteria a Internet. Es necessita tenir ben definits els circuits de compra, de venda, de facturació, de control d'existències, de cobraments i de pagaments, entre d'altres. Per gestionar tota aquesta activitat, s’ha fet servir el ERP Navision amb SQL Server, adaptant-lo i creant noves funcionalitats. L'aplicació Web ha estat integrada amb Navision i s'ha desenvolupat la seva funcionalitat, tenint sessions per a usuari amb comptes propis que permeten la consulta i la compra dels productes que ofereix l'empresa.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We propose a new method, based on inertial sensors, to automatically measure at high frequency the durations of the main phases of ski jumping (i.e. take-off release, take-off, and early flight). The kinematics of the ski jumping movement were recorded by four inertial sensors, attached to the thigh and shank of junior athletes, for 40 jumps performed during indoor conditions and 36 jumps in field conditions. An algorithm was designed to detect temporal events from the recorded signals and to estimate the duration of each phase. These durations were evaluated against a reference camera-based motion capture system and by trainers conducting video observations. The precision for the take-off release and take-off durations (indoor < 39 ms, outdoor = 27 ms) can be considered technically valid for performance assessment. The errors for early flight duration (indoor = 22 ms, outdoor = 119 ms) were comparable to the trainers' variability and should be interpreted with caution. No significant changes in the error were noted between indoor and outdoor conditions, and individual jumping technique did not influence the error of take-off release and take-off. Therefore, the proposed system can provide valuable information for performance evaluation of ski jumpers during training sessions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The RT-PCR technique for the detection of apple stem grooving virus (ASGV), apple stem pitting virus (ASPV), apple chlorotic leaf spot virus (ACLSV), apple mosaic virus (ApMV) and pear blister canker viroid (PBCV) was evaluated for health control of fruit plants from nurseries. The technique was evaluated in purified RNA and crude extracts and also in phloem collected in autumn and from young spring shoots. The results obtained for phytoplasma detection with ribosomal and non-ribosomal primers are also presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The Internet is a fundamental part of the daily life of adolescents, they consider it as a safe and confidential source of information on health matters. The aims is to describe the experience of Spanish adolescents searching for health information on the Internet. Methods A cross-sectional study of 811 school-age adolescents in Granada was carried out. An adapted and piloted questionnaire was used which was controlled by trained personnel. Sociodemographic and health variables were included together with those concerning the conditions governing access to and use of information and communication technologies (ICT). Results 811 adolescents were surveyed (99.38% response rate), mean age was 17 years old. Of these, 88% used the Internet; 57.5% used it on a daily or weekly basis and 38.7% used it occasionally. Nearly half the sample group (55.7%) stated that they used the Internet to search for health-related information. The main problems reported in the search for e-health were the ignorance of good web pages (54.8%) and the lack of confidence or search skills (23.2%). Conclusions In conclusion, it seems plausible to claim that websites designed and managed by health services should have a predominant position among interventions specifically addressed to young people.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thanks to decades of research, gait analysis has become an efficient tool. However, mainly due to the price of the motion capture systems, standard gait laboratories have the capability to measure only a few consecutive steps of ground walking. Recently, wearable systems were proposed to measure human motion without volume limitation. Although accurate, these systems are incompatible with most of existing calibration procedures and several years of research will be necessary for their validation. A new approach consisting of using a stationary system with a small capture volume for the calibration procedure and then to measure gait using a wearable system could be very advantageous. It could benefit from the knowledge related to stationary systems, allow long distance monitoring and provide new descriptive parameters. The aim of this study was to demonstrate the potential of this approach. Thus, a combined system was proposed to measure the 3D lower body joints angles and segmental angular velocities. It was then assessed in terms of reliability towards the calibration procedure, repeatability and concurrent validity. The dispersion of the joint angles across calibrations was comparable to those of stationary systems and good reliability was obtained for the angular velocities. The repeatability results confirmed that mean cycle kinematics of long distance walks could be used for subjects' comparison and pointed out an interest for the variability between cycles. Finally, kinematics differences were observed between participants with different ankle conditions. In conclusion, this study demonstrated the potential of a mixed approach for human movement analysis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

RÉSUMÉ Contexte : Peu d'études ont examiné la façon dont les médecins appréhendent les guidelines, et encore moins celle dont ils perçoivent de tels guidelines disponibles sur Internet. Cette étude évalue l'acceptation par les médecins d'un guideline électronique portant sur l'adéquation de la colonoscopie. Méthode : Des gastroentérologues participant à une étude observationnelle internationale ont consulté un guideline électronique pour une série consécutive de patients adressés pour une colonoscopie. Le guideline a été élaboré par le Panel Européen sur l'Adéquation de l'Endoscopie Gastro-intestinale (EPAGE en version anglaise), utilisant une méthode validée (RAND). Les opinions des médecins sur le guideline, sur le site Internet et sur les perspectives d'utilisation ont été recueillies au moyen de questionnaires. Résultats : 289 patients ont été inclus dans l'étude. Le temps moyen pour consulter le site Internet a été de 1.8 min et 86% des médecins l'ont considéré comme simple à utiliser. Les recommandations ont été facilement localisées pour 82% des patients et les médecins étaient d'accord avec l'adéquation de la colonoscopie dans 86% des cas. Selon les critères EPAGE, la colonoscopie était appropriée, incertaine et inappropriée, respectivement chez 59, 28 et 13% des patients. Conclusions : Le guideline EPAGE a été considéré comme acceptable et simple à utiliser. L'utilisation, l'utilité et la pertinence du site Internet a été jugée comme acceptable. Son utilisation effective dépendra cependant de la levée de certains obstacles au niveau organisationnel et culturel.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A ubiquitous assessment of swimming velocity (main metric of the performance) is essential for the coach to provide a tailored feedback to the trainee. We present a probabilistic framework for the data-driven estimation of the swimming velocity at every cycle using a low-cost wearable inertial measurement unit (IMU). The statistical validation of the method on 15 swimmers shows that an average relative error of 0.1 ± 9.6% and high correlation with the tethered reference system (rX,Y=0.91 ) is achievable. Besides, a simple tool to analyze the influence of sacrum kinematics on the performance is provided.