942 resultados para Valve metals


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solders are not new alloys, since they were known in late Roman times when they were mentioned by Pliny. These solders differed very little from our modern ones. Tertiarium, consisting of one part of tin to two parts of lead, is known today as plumbers solder; and argentarium, consisting of equal parts of lend and tin, is still extensively used for many purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem presented for this thesis was an investigation of the magnetic properties of the alloys produced by the methods of powder metallurgy. The question behind this was the correlation of the magnetic properties with the bonding properties and with the diffusion of the constituents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: The standard surgical repair of disease of the aortic valve and the ascending aorta has been combined replacement, which includes the disadvantage of inserting a mechanical valve. We have investigated an individualized approach which preserves the native valve. PATIENTS AND METHODS: Between October 1995 and October 1997, a consecutive total of 101 patients (72 men, 29 women, aged 21-83 years) underwent operations for disease of the ascending aorta: aortic dissection type A in 34 patients, aneurysmal dilatation in 67. Dilatation of the aortic arch was associated with aortic regurgitation in 58 patients. There were 11 patients with aortic valve stenosis or previously implanted aortic valve prosthesis among a total of 46 whose aortic valve was replaced (group II). Supracommissural aortic replacement with a Dacron tube was performed in 16 patients (group I) with normal valve cusps and an aortic root diameter < 3.5 cm. In 28 patients with an aortic root diameter of 3.5-5.0 cm the aortic root was remodelled (group III). Resuspension of the native aortic valve was undertaken in 11 patients with aortic root dilatation of > 5.0 cm (group IV). RESULTS: Operative intervention was electively performed in 72 patients, without any death. Of 29 patients operated as an emergency for acute type A dissection four died (14%). In 55 of the 58 patients with aortic regurgitation in proved possible to preserve native aortic valve (95%). In the early postoperative phase and after an average follow-up time of 11.8 months, transthoracic echocardiography demonstrated good aortic valve function, except in one patient each of groups III and IV who developed aortic regurgitation grades I or II. CONCLUSION: The described individualized approach makes it possible to preserve the native aortic valve in most patients with aortic regurgitation, at a low risk. Follow-up observations so far indicate good results of the reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tricuspid regurgitation following heart transplantation can become a severe problem in a subset of patients, where medical therapy fails. Operative findings are described and results of subsequent results with surgical intervention including repair and replacement are analysed. Although follow-up is short, tricuspid replacement seems superior to reconstruction following heart transplantation. Best results are obtained, if replacement is performed, before right ventricular function deteriorates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present report the prevalence, severity, and risk factors of tricuspid valve regurgitation (TR) in 251 heart transplant recipients have been analyzed retrospectively. Tricuspid valve function was studied by color-flow Doppler echocardiogram and annual heart catheterization. The presence or severity of TR was graded on a scale from 0 (no TR) to 4 (severe). Additional postoperative data included rate of rejection, number of endomyocardial biopsies, incidence of transplant vasculopathy, and preoperative and postoperative hemodynamics. The incidence of grade 3 TR increases from 5% at 1 year to 50% at 4 years after transplantation. Multivariate analysis showed rate of rejection and donor heart weight to be significant risk factors. The ischemic intervals as well as the preoperative and postoperative pulmonary hemodynamics did not affect the severity or prevalence of TR. These results indicate that various factors appear to have an impact on the development of TR and that the prevalence might be lowered by a reduction of the number of biopsies performed and when possible, oversizing of donor hearts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Regression of left ventricular (LV) hypertrophy with normalization of diastolic function has been reported in patients with aortic stenosis late after aortic valve replacement (AVR). The purpose of the present study was to evaluate the effect of AVR on LV function and structure in chronic aortic regurgitation early and late after AVR. METHODS AND RESULTS: Twenty-six patients were included in the present analysis. Eleven patients with severe aortic regurgitation were studied before, early (21 months) and late (89 months) after AVR through the use of LV biplane angiograms, high-fidelity pressure measurements, and LV endomyocardial biopsies. Fifteen healthy subjects were used as controls. LV systolic function was determined from biplane ejection fraction and midwall fractional shortening. LV diastolic function was calculated from the time constant of LV relaxation, peak filling rates, and myocardial stiffness constant. LV structure was assessed from muscle fiber diameter, interstitial fibrosis, and fibrous content. LV muscle mass decreased significantly by 38% early and 55% late after surgery. Ejection fraction was significantly reduced preoperatively and did not change after AVR (P=NS). LV relaxation was significantly prolonged before surgery (89+/-28 ms) but was normalized late after AVR (42+/-14 ms). Early and late peak filling rates were increased preoperatively but normalized postoperatively. Diastolic stiffness constant was increased before surgery (22+/-6 versus 9+/-3 in control subjects; P=0.0003) and remained elevated early and late after AVR (23+/-4; P=0.002). Muscle fiber diameter decreased significantly after AVR but remained increased at late follow-up. Interstitial fibrosis was increased preoperatively and increased even further early but decreased late after AVR. Fibrosis was positively linearly correlated to myocardial stiffness and inversely correlated to LV ejection fraction. CONCLUSIONS: Patients with aortic regurgitation show normalization of macroscopic LV hypertrophy late after AVR, although fiber hypertrophy persists. These changes in LV myocardial structure late after AVR are accompanied by a change in passive elastic properties with persistent diastolic dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated the relative contribution of hemodynamic and clinical factors to serum natriuretic peptide elevation in seventy-one patients with either aortic stenosis or aortic regurgitation. We found that pulmonary hypertension, heart failure and renal failure are the most powerful independent predictors of natriuretic peptide elevation in patients with aortic valve disease, irrespective of the type or severity of valvular lesion itself.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The association between aortic valve disease and coronary atherosclerosis is common. In the recent era of percutaneous aortic valve replacement (PAVR), there is little experience with coronary artery intervention after valve implantation. CASE REPORT: To our knowledge, this is the first case of successful percutaneous coronary intervention after implantation of a CoreValve percutaneous aortic valve. We report a case of a 79-year-old female patient who underwent successful coronary artery intervention few months after a CoreValve's percutaneous implantation for severe aortic valve stenosis. Verifying the position of the used wires (crossing from inside the self expanding frame) is of utmost importance before proceeding to coronary intervention. In this case, crossing the aortic valve, coronary angiography, and multivessel stenting were successfully performed. CONCLUSION: Percutaneous coronary intervention in patients with previous CoreValve is feasible and safe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter aortic valve implantation (TAVI) for high-risk and inoperable patients with severe aortic stenosis is an emerging procedure in cardiovascular medicine. Little is known of the impact of TAVI on renal function. METHODS: We analysed retrospectively renal baseline characteristics and outcome in 58 patients including 2 patients on chronic haemodialysis undergoing TAVI at our institution. Acute kidney injury (AKI) was defined according to the RIFLE classification. RESULTS: Fifty-eight patients with severe symptomatic aortic stenosis not considered suitable for conventional surgical valve replacement with a mean age of 83 +/- 5 years underwent TAVI. Two patients died during transfemoral valve implantation and two patients in the first month after TAVI resulting in a 30-day mortality of 6.9%. Vascular access was transfemoral in 46 patients and transapical in 12. Estimated glomerular filtration rate (eGFR) increased in 30 patients (56%). Fifteen patients (28%) developed AKI, of which four patients had to be dialyzed temporarily and one remained on chronic renal replacement therapy. Risk factors for AKI comprised, among others, transapical access, number of blood transfusions, postinterventional thrombocytopaenia and severe inflammatory response syndrome (SIRS). CONCLUSIONS: TAVI is feasible in patients with a high burden of comorbidities and in patients with pre-existing end-stage renal disease who would be otherwise not considered as candidates for conventional aortic valve replacement. Although GFR improved in more than half of the patients, this benefit was associated with a risk of postinterventional AKI. Future investigations should define preventive measures of peri-procedural kidney injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: It is unclear whether transcatheter aortic valve implantation (TAVI) addresses an unmet clinical need for those currently rejected for surgical aortic valve replacement (SAVR) and whether there is a subgroup of high-risk patients benefiting more from TAVI compared to SAVR. In this two-centre, prospective cohort study, we compared baseline characteristics and 30-day mortality between TAVI and SAVR in consecutive patients undergoing invasive treatment for aortic stenosis. METHODS AND RESULTS: We pre-specified different adjustment methods to examine the effect of TAVI as compared with SAVR on overall 30-day mortality: crude univariable logistic regression analysis, multivariable analysis adjusted for baseline characteristics, analysis adjusted for propensity scores, propensity score matched analysis, and weighted analysis using the inverse probability of treatment (IPT) as weights. A total of 1,122 patients were included in the study: 114 undergoing TAVI and 1,008 patients undergoing SAVR. The crude mortality rate was greater in the TAVI group (9.6% vs. 2.3%) yielding an odds ratio [OR] of 4.57 (95%-CI 2.17-9.65). Compared to patients undergoing SAVR, patients with TAVI were older, more likely to be in NYHA class III and IV, and had a considerably higher logistic EuroSCORE and more comorbid conditions. Adjusted OR depended on the method used to control for confounding and ranged from 0.60 (0.11-3.36) to 7.57 (0.91-63.0). We examined the distribution of propensity scores and found scores to overlap sufficiently only in a narrow range. In patients with sufficient overlap of propensity scores, adjusted OR ranged from 0.35 (0.04-2.72) to 3.17 (0.31 to 31.9). In patients with insufficient overlap, we consistently found increased odds of death associated with TAVI compared with SAVR irrespective of the method used to control confounding, with adjusted OR ranging from 5.88 (0.67-51.8) to 25.7 (0.88-750). Approximately one third of patients undergoing TAVI were found to be potentially eligible for a randomised comparison of TAVI versus SAVR. CONCLUSIONS: Both measured and unmeasured confounding limit the conclusions that can be drawn from observational comparisons of TAVI versus SAVR. Our study indicates that TAVI could be associated with either substantial benefits or harms. Randomised comparisons of TAVI versus SAVR are warranted.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Pulmonary valve insufficiency remains a leading cause for reoperations in congenital cardiac surgery. The current percutaneous approach is limited by the size of the access vessel and variable right ventricular outflow tract morphology. This study assesses the feasibility of transapical pulmonary valve replacement based on a new valved stent construction concept. METHODS: A new valved stent design was implanted off-pump under continuous intracardiac echocardiographic and fluoroscopic guidance into the native right ventricular outflow tract in 8 pigs (48.5 +/- 6.0 kg) through the right ventricular apex, and device function was studied by using invasive and noninvasive measures. RESULTS: Procedural success was 100% at the first attempt. Procedural time was 75 +/- 15 minutes. All devices were delivered at the target site with good acute valve function. No valved stents dislodged. No animal had significant regurgitation or paravalvular leaking on intracardiac echocardiographic analysis. All animals had a competent tricuspid valve and no signs of right ventricular dysfunction. The planimetric valve orifice was 2.85 +/- 0.32 cm(2). No damage to the pulmonary artery or structural defect of the valved stents was found at necropsy. CONCLUSIONS: This study confirms the feasibility of direct access valve replacement through the transapical procedure for replacement of the pulmonary valve, as well as validity of the new valved stent design concept. The transapical procedure is targeting a broader patient pool, including the very young and the adult patient. The device design might not be restricted to failing conduits only and could allow for implantation in a larger patient population, including those with native right ventricular outflow tract configurations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pasteurella species are part of the oral flora of cats and dogs. In humans, they are frequently found in infected animal bite wounds, but invasive infections are rare. This is the first report of prosthetic-valve endocarditis with a Pasteurella dagmatis-like species, which originated from the patient's cat.