840 resultados para ULTRASOUND-ENHANCED THROMBOLYSIS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Capsular contracture is the main complication related to breast silicone implants, and its prevention remains a medical challenge. The authors present experimental research examining the effect of external ultrasound on the formation and contracture of peri-implant capsules.Methods In this study, 42 male Wistar rats had a 2-mm smooth surface implant placed in a dorsal submuscular pocket. They then were separated into ultrasound'' and control'' groups that received repeated external applications either with or without the ultrasound power on. Ultrasound applications were given three times a week for a period of 90 days. After that, both groups were housed under the same conditions with no application scheduled. Five animals of each group, killed at 30, 60, 90, and 180 days, had their implants removed along with the capsule, which received a special histologic preparation via annular sectioning that provided wide circumferential observation of the capsular tissue. Sections were stained with hematoxylin/eosin stain, Masson's trichrome stain, and Pricrosirius Red stain for regular microscopic evaluation under normal and polarized light.Results Histologic data showed that capsules from the ultrasound and control groups had statistically significant differences. Ultrasound application developed a capsular architecture similar to that shown within textured silicone implants, and its effect had an early definition with subsequent stabilization.Conclusion The authors conclude that early and repeated external ultrasound application enhances the thickness, cellular count, and vascularity of smooth silicone capsular tissue, whereas it diminishes the pattern of parallel orientation of collagen fibers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To evaluate the host response of the gel and porous polyethylene implants in anophthalmic cavities using the B scan ultrasound.METHODS: Thirty-six white rabbits underwent unilateral enucleation with placement of gel or porous polyethylene spheres implants. The animals were submitted to clinical examination weekly and to ultrasound evaluation on 30, 60 and 90 days after surgery.RESULTS: All rabbits with gel polyethylene spheres, except one, showed implant extrusion probably because the gel spheres have hydrated and increased in volume. The B ultrasound of the gel polyethylene implant did not show vessels inside during the following period. Five animals (27.8%) with porous polyethylene spheres presented implant extrusion after 30 days of surgery. According to B ultrasound, the porous polyethylene implant showed irregular and heterogeneous architecture and reflective peaks similar to vascularized tissues.CONCLUSION: More studies are required to determine the ideal volume of gel polyethylene implant necessary to correct the diminished orbital content in the anophthalmic cavity. The B ultrasound effectiveness showed in this study for anophthalmic socket implants evaluation provides useful information for further in vivo studies and might substitute expensive methods of implants vascularization evaluation,

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Strains of mice with maximal and minimal acute inflammatory responsiveness (AIRmax and AIRmin, respectively) were developed through selective breeding based on their high- or low-acute inflammatory responsiveness. Previous reports have shown that AIRmax mice are more resistant to the development of a variety of tumours than AIRmin mice, including spontaneous metastasis of murine melanoma. Natural killer activity is involved in immunosurveillance against tumour development, so we analysed the number and activity of natural killer cells (CD49b(+)), T-lymphocyte subsets and in vitro cytokine production by spleen cells of normal AIRmax and AIRmin mice. Analysis of lymphocyte subsets by flow cytometry showed that AIRmax mice had a higher relative number of CD49b(+) cells than AIRmin mice, as well as cytolytic activity against Yac.1 target cells. The number of CD3(+) CD8(+) cells was also higher in AIRmax mice. These findings were associated with the ability of spleen cells from AIRmax mice in vitro to produce higher levels of the pro-inflammatory cytokines tumour necrosis factor-alpha, interleukin-12p40 and interferon-gamma but not the anti-inflammatory interleukin-10. Taken together, our data suggest that the selective breeding to achieve the AIRmax and AIRmin strains was able to polarize the genes associated with cytotoxic activity, which can be responsible for the antitumour resistance observed in AIRmax mice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVETo evaluate the correlation between ultrasound-estimated bladder weight (UEBW) in patients with different degrees of bladder outlet obstruction (BOO).METHODSWe evaluated 50 consecutive non-neurogenic male patients with lower urinary tract symptoms (LUTS) referred to urodynamic study (UDS). All patients self-answered the International Prostate Score Symptoms (IPSS) questionnaire. After the UDS, the bladder was filled with 150 mL to determine UEBW.Patients with a bladder capacity under 150 mL, a previous history of prostate surgery or pelvic irradiation, an IPSS score <8, a bladder stone or urinary tract infection were excluded.After a pressure-flow study, the Schafer linear passive urethral resistance relation nomogram was plotted to determine the grade of obstruction: Grades I-II/VI were defined as mild obstruction, Grades III-IV/VI as moderate obstruction, and Grades V-VI/VI as severe obstruction.RESULTSThe UEBW was 51.7 +/- 26.9, 54.1 +/- 30.0 and 54.8 +/- 28.2 in patients with mild, moderate and severe BOO, respectively (P = 0.130). The UEBW allowed us to define four groups: (i) UEBW < 35 g; (ii) 35 g <= UEBW < 50 g; (iii) 50 g <= UEBW < 70 g; and (4) UEBW >= 70 g.We did not find any differences in age, prostate weight, IPSS, PVR, cystometric bladder capacity, presence of detrusor overactive and degree of obstruction in the aforementioned groups.CONCLUSIONDespite the fact that some studies have emphasized the value of UEBW as an efficient non-invasive method for evaluating lower urinary tract obstruction, our study suggests that UEBW does not present any individual correlation with LUTS or objective measurements of BOO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real-time ultrasonography (RTU) was used to measure the longissimus dorsi muscle (LM) volume in vivo and to predict the carcass composition of rabbits. For this, 63 New Zealand White × Californian rabbits with 2093±63 g live weight were used. Animals were scanned between the 6th and 7th lumbar vertebrae using an RTU equipment with a 7.5 MHz probe. Measurements of LM volume were obtianed both in vivo and on carcass. Regression equations were used for the prediction of carcass composition and LM volume using the LM volume measured obtained with RTU (LMVU) as independent variable. Carcass meat, bone and total dissectible fat weights represented 780, 164 and 56 g/kg of the reference carcass weight, respectively. Regression equations showed a strong relationship between LMVU and the correspondent volume in carcass. Furthermore, LMVU was also useful in predicting the amounts of carcass tissues. It is possible to predict LM volume in the carcass using the LM volume measured in vivo by RTU. The amount of carcass tissues can be predicted by the LM volume measured in vivo by RTU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes an alternative surgical approach to the harvesting of subepithelial connective tissue grafts from thin palates. A partial-thickness flap is raised, and a graft composed of epithelium and connective tissue is removed from the palate. The superficial layer ( epithelium and a thin zone of connective tissue) is then dissected from the graft and replaced at the donor site to facilitate faster healing. The subjacent layer of connective tissue is placed as needed to obtain root coverage. The clinical application of this technique is described in two patients with multiple gingival recessions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PVC films submitted to ultrasonic irradiation presented structural changes as probed by infrared measurements. These measurements showed some infrared bands alterations attributed to the increase concentration of some conformational isomers of PVC and the presence of some new species in the macromolecular matrix. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate the in vivo and in vitro reactivity of airway smooth muscle in rats depleted of sensory neuropeptides by treatment with capsaicin at neonatal stage. Wistar rats were neonatally injected with either capsaicin (50 mg/kg, s.c., 2nd day of life) or its vehicle (10% ethanol and 10% Tween 80, in 0.9% w/v NaCl solution) and used at adult ages (60-70 days later). Analysis of the lungs showed a higher number of infiltrating neutrophils, eosinophils and mononuclear cells into the peribronchiolar regions of capsaicin-pretreated rats compared to vehicle group. This was associated with a higher contraction index of bronchiolar wall in the capsaicin group. The in vitro tracheal reactivity in response to methacholine (full muscarinic agonist) and pilocarpine (partial muscarinic agonist) was also significantly higher in capsaicin-pretreated rats compared to vehicle group. In conclusion, the neuropeptide depletion by capsaicin neonatal treatment lead to marked contraction of the rat airways at adult age, suggesting a protective role for C fibers in the lungs. (C) 2003 Elsevier B.V. Ireland Ltd. All rights reserved.