924 resultados para Transformer voltage equations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we deal with the research of a proposed mathematical model of energy harvesting, including nonlinearities in the piezoelectric coupling and a non-ideal force of excitation. We showed using numerical simulations to analysis of the dynamic responses that, the power harvested was influenced by the nonlinear vibrations of the structure, as well as by the influence of the non-linearities in the piezoelectric coupling. We concluded through of the numerical results that the limited energy source was interacting with the system. Thus, the increasing of the voltage in DC motor led the system produce a good power response, especially in high-energy orbits in the resonance region, but the Sommerfeld effect occurs in the system and a chaotic behavior was found in the post-resonance region. So the power harvested along the time decreases because occurs loses of energy due the interaction between energy source and structure. Keeping the energy harvested constant over time is essential to make possible the use of energy harvesting systems in real applications. To achieve this objective, we applied a control technique in order to stabilize the chaotic system in a periodic stable orbit. We announced that the results were satisfactory and the control maintained the system in a stable condition. © 2012 Foundation for Scientific Research and Technological Innovation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a mixed-integer linear programming model to solve the problem of allocating voltage regulators and fixed or switched capacitors (VRCs) in radial distribution systems. The use of a mixed-integer linear model guarantees convergence to optimality using existing optimization software. In the proposed model, the steady-state operation of the radial distribution system is modeled through linear expressions. The results of one test system and one real distribution system are presented in order to show the accuracy as well as the efficiency of the proposed solution technique. An heuristic to obtain the Pareto front for the multiobjective VRCs allocation problem is also presented. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of seed addition on the microstructure and non-ohmic properties of the SnO2 + 1%CoO + 0.05%Nb2O5 ceramic-based system was analyzed. Two classes of seeds were prepared: 99% SnO2 + 1%CuO and 99% SnO2 + 1%CoO (mol%); both classes were added to the ceramic-based system in the amount of 1%, 5%, and 10%. The two systems containing 1% of seeds resulted in a larger grain size and a lower breakdown voltage. The addition of 1% copper seeds produces a breakdown voltage (V b) of ∼ 37 V and a leakage current (fic) of 29 μA. On the other hand, the addition of 1% cobalt seeds produced a breakdown voltage of 57 V and a leakage current of 70 μA. Both systems are of great technological interest for low voltage varistor applications, by means of appropriate strategies to reduce the leakage current. Using larger amounts of seeds was not effective since the values of breakdown voltage in both cases are close to a system without seeds. To our knowledge, there are no reports in the literature regarding the use of seeds in the SnO2 system for low voltage applications. A potential barrier model which illustrates the formation of oxygen species (O′2(ads), O′ads, and O″ads) at the expense of clusters near the interface between grains is proposed. © 2012 The American Ceramic Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Processing of the YMn2O5 powder is very challenging, since it decomposes to YMnO3 and Mn3O4 at temperatures close to 1180 °C, while samples consolidation commonly demands high temperatures. The main goal of this work is to investigate a possibility to prepare thick films of YMn2O5, since their deposition generally requires significantly lower temperatures. Multiferroic YMn 2O5 was synthesized by the hydrothermal method from Y(CH3COO)3·xH2O, Mn(CH 3COO)2·4H2O and KMnO4 precursors. XRD, FE-SEM and TEM analysis showed that the obtained powder was monophasic, with orthorhombic crystal structure and columnar particle shape with mean diameter and length of around 20 and 50 nm, respectively. The obtained powder was suspended in isopropyl alcohol with addition of appropriate binder and deflocculant. This suspension was used for electrophoretic deposition of YMn2O5 thick films under the high-voltage conditions and electric fields ranging from 250 to 2125 V/cm. The films obtained at 1000 V/cm and higher electric fields showed good adhesion, particle packing, homogeneity and very low porosity. It was shown that the deposition in extremely high electric fields (KC=2125 V/cm) can influence the crystal orientation of the films, resulting in formation of preferentially oriented films. © 2012 Elsevier Ltd and Techna Group S.r.l.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We provide a simple method for writing the Dirac-Born-Infeld equations of a Dp-brane in an arbitrary static background whose metric depends only on the holographic radial coordinate z. Using this method we revisit the Karch-O'Bannon procedure to calculate the dc conductivity in the presence of constant electric and magnetic fields for backgrounds where the boundary is four- or three-dimensional and satisfies homogeneity and isotropy. We find a frame-independent expression for the dc conductivity tensor. For particular backgrounds we recover previous results on holographic metals and strange metals. © 2013 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The viability of achieving gravitational consistent braneworld models in the framework of a f(R) theory of gravity is investigated. After a careful generalization of the usual junction conditions encompassing the embedding of the 3-brane into a f(R) bulk, we provide a prescription giving the necessary constraints in order to implement the projected second-order effective field equations on the brane. © 2013 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using an approach based on the Casimir operators of the de Sitter group, conformally invariant equations for a fundamental spin-2 field are obtained, and their consistency is discussed. It is shown that only when the spin-2 field is interpreted as a 1-form assuming values in the Lie algebra of the translation group, rather than a symmetric second-rank tensor, the field equation is both conformally and gauge invariant. © 2013 Pleiades Publishing, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to use 15N to label microbial cells to allow development of equations for estimating the microbial contamination in ruminal in situ incubation residues of forage produced under tropical conditions. A total of 24 tropical forages were ruminal incubated in 3 steers at 3 separate times. To determine microbial contamination of the incubated residues, ruminal bacteria were labeled with 15N by continuous intraruminal infusion 60 h before the first incubation and continued until the last day of incubation. Ruminal digesta was collected for the isolation of bacteria before the first infusion of 15N on adaptation period and after the infusion of 15N on collection period. To determine the microbial contamination of CP fractions, restricted models were compared with the full model using the model identity test. A value of the corrected fraction A was estimated from the corresponding noncorrected fraction by this equation: Corrected A fraction (ACPC) = 1.99286 + 0.98256 × A fraction without correction (ACPWC). The corrected fraction B was estimated from the corresponding noncorrected fraction and from CP, NDF, neutral detergent insoluble protein (NDIP), and indigestible NDF (iNDF) using the equation corrected B fraction (BCPC) = -17.2181 - 0.0344 × fraction B without correction (BCPWC) + 0.65433 × CP + 1.03787 × NDF + 2.66010 × NDIP - 0.85979 × iNDF. The corrected degradation rate of B fraction (kd)was estimated using the equation corrected degradation rate of B fraction (kdCPC) = 0.04667 + 0.35139 × degradation rate of B fraction without correction (kdCPWC) + 0.0020 × CP - 0.00055839 × NDF - 0.00336 × NDIP + 0.00075089 × iNDF. This equation was obtained to estimate the contamination using CP of the feeds: %C = 79.21 × (1 - e-0.0555t) × e-0.0874CP. It was concluded that A and B fractions and kd of CP could be highly biased by microbial CP contamination, and therefore these corrected values could be obtained mathematically, replacing the use of microbial markers. The percentage of contamination and the corrected apparent degradability of CP could be obtained from values of CP and time of incubation for each feed, which could reduce cost and labor involved when using 15N. © 2013 American Society of Animal Science. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the network reconfiguration context, the challenge nowadays is to improve the system in order to get intelligent systems that are able to monitor the network and produce refined information to support the operator decisions in real time, this because the network is wide, ramified and in some places difficult to access. The objective of this paper is to present the first results of the network reconfiguration algorithm that has been developed to CEMIG-D. The algorithm's main idea is to provide a new network configuration, after an event (fault or study case), based on an initial condition and aiming to minimize the affected load, considering the restrictions of load flow equations, maximum capacity of the lines as well as equipments and substations, voltage limits and system radial operation. Initial tests were made considering real data from the system, provided by CEMIG-D and it reveals very promising results. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides a contribution to the contingency analysis of electric power systems under steady state conditions. An alternative methodology is presented for static contingency analyses that only use continuation methods and thus provides an accurate determination of the loading margin. Rather than starting from the base case operating point, the proposed continuation power flow obtains the post-contingency loading margins starting from the maximum loading and using a bus voltage magnitude as a parameter. The branch selected for the contingency evaluation is parameterised using a scaling factor, which allows its gradual removal and assures the continuation power flow convergence for the cases where the method would diverge for the complete transmission line or transformer removal. The applicability and effectiveness of the proposed methodology have been investigated on IEEE test systems (14, 57 and 118 buses) and compared with the continuation power flow, which obtains the post-contingency loading margin starting from the base case solution. In general, for most of the analysed contingencies, few iterations are necessary to determine the post-contingency maximum loading point. Thus, a significant reduction in the global number of iterations is achieved. Therefore, the proposed methodology can be used as an alternative technique to verify and even to obtain the list of critical contingencies supplied by the electric power systems security analysis function. © 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we improve the regularity in time of the gradient of the pressure field in the solution of relaxed version of variational formulation proposed by V. I. Arnold and by Y. Brenier, for the incompressible Euler equations with variable density. We obtain that the pressure field is not only a measure, but a function in Lloc2((0,T);BVloc(D)) as an extension of the work of Ambrosio and Figalli (2008) in [1] to the variable density case. © 2013 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)