908 resultados para Three-phase power flow


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development and implementation of a population supplementation and restoration plan for any endangered species should involve an understanding of the species’ habitat requirements prior to the release of any captive bred individuals. The freshwater pearl mussel, Margaritifera margaritifera, has undergone dramatic declines over the last century and is now globally endangered. In Northern Ireland, the release of captive bred individuals is being used to support wild populations and repatriate the species in areas where it once existed. We employed a combination of maximum entropy modelling (MAXENT) and Generalized Linear Mixed Models (GLMM) to identify ecological parameters necessary to support wild populations using GIS-based landscape scale and ground-truthed habitat scale environmental parameters. The GIS-based landscape scale model suggested that mussel occurrence was associated with altitude and soil characteristics including the carbon, clay, sand, and silt content. Notably, mussels were associated with a relatively narrow band of variance indicating that M. margaritifera has a highly specific landscape niche. The ground-truthed habitat scale model suggested that mussel occurrence was associated with stable consolidated substrates, the extent of bankside trees, presence of indicative macrophyte species and fast flowing water. We propose a three phase conservation strategy for M. margaritifera identifying suitable areas within rivers that (i) have a high conservation value yet needing habitat restoration at a local level, (ii) sites for population supplementation of existing populations and (iii) sites for species reintroduction to rivers where the mussel historically occurred but is now locally extinct. A combined analytical approach including GIS-based landscape scale and ground-truthed habitat scale models provides a robust method by which suitable release sites can be identified for the population supplementation and restoration of an endangered species. Our results will be highly influential in the future management of M. margaritifera in Northern Ireland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to identify, through a consensus process, the essential practices in primary palliative care. A three-phase study was designed. Phase 1 methods included development of a working group; a literature review; development of a baseline list of practices; and identification of levels of intervention. In Phase 2, physicians, nurses, and nurse aides (n = 425) from 63 countries were asked in three Delphi rounds to rate the baseline practices as essential or nonessential and select the appropriate levels of intervention for each. In Phase 3, representatives of 45 palliative care organizations were asked to select and rank the 10 most important practices resulting from Phase 2. Scores (1-10) were assigned to each, based on the selected level of importance. Results of Phase 1 were a baseline list of 140 practices. Three levels of intervention were identified: Identification/Evaluation; Diagnosis; and Treatment/Solution measures. In Phase 2, the response rates (RR) for the Delphi rounds were 96.5%, 73.6%, and 71.8%, respectively. A consensus point (=80% agreement) was applied, resulting in 62 practices. In Phase 3, RR was 100%. Forty-nine practices were selected and ranked. "Evaluation, Diagnosis and Treatment of Pain" scored the highest (352 points). The working group (WG) arranged the resulting practices in four categories: Physical care needs, Psychological/Emotional/Spiritual care needs, Care Planning and Coordination, and Communication. The IAHPC List of Essential Practices in Palliative care may help define appropriate primary palliative care and improve the quality of care delivered globally. Further studies are needed to evaluate their uptake and impact.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a novel approach for introducing aligned carbon nanotubes (CNTs) at the crack interface of pre-impregnated (prepreg) carbon fibre composite plies, creating a hierarchical (three-phase) composite structure. The aim of this approach is to improve the interlaminar fracture toughness. The developed method for transplanting the aligned CNTs from the silicon wafer onto the pre-preg material is described. Scanning electron microscopy (SEM) was used to analyse the effects of the transplantation method. Double Cantilever Beam (DCB) specimens were prepared, according to ASTM standard D5528- 01R07E03 [1] and aligned multi-walled carbon nanotubes (MWCNTs) were introduced at the crack-tip. Mode I fracture tests for pristine (control) specimens and CNT-enhanced specimens were conducted and an average increase in the critical strain energy release rate (GIc) of approximately 50 % was achieved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The impact of power fluctuations arising from fixed-speed wind turbines on the magnitude and frequency of inter-area oscillations was investigated. The authors used data acquisition equipment to record the power flow on the interconnector between the Northern Ireland and Republic of Ireland systems. By monitoring the interconnector oscillation using a fast Fourier transform, it was possible to determine the magnitude and frequency of the inter-area oscillation between the Northern Ireland electricity system and that of the electricity supply board. Analysis was preformed to determine the relationship (if any) between the inter-area oscillation and the observed wind power generation at the corresponding time. Subsequently, regression analysis was introduced to model this relationship between the FFT output and the wind power generation. The effect of conventional generators on the magnitude and frequency of the inter-area oscillation was also considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Organismal metabolic rates influence many ecological processes, and the mass-specific metabolic rate of organisms decreases with increasing body mass according to a power law. The exponent in this equation is commonly thought to be the three-quarter-power of body mass, determined by fundamental physical laws that extend across taxa. However, recent work has cast doubt as to the universality of this relationship, the value of 0.75 being an interspecies 'average' of scaling exponents that vary naturally between certain boundaries. There is growing evidence that metabolic scaling varies significantly between even closely related species, and that different values can be associated with lifestyle, activity and metabolic rates. Here we show that the value of the metabolic scaling exponent varies within a group of marine ectotherms, chitons (Mollusca: Polyplacophora: Mopaliidae), and that differences in the scaling relationship may be linked to species-specific adaptations to different but overlapping microhabitats. Oxygen consumption rates of six closely related, co-occurring chiton species from the eastern Pacific (Vancouver Island, British Columbia) were examined under controlled experimental conditions. Results show that the scaling exponent varies between species (between 0.64 and 0.91). Different activity levels, metabolic rates and lifestyle may explain this variation. The interspecific scaling exponent in these data is not significantly different from the archetypal 0.75 value, even though five out of six species-specific values are significantly different from that value. Our data suggest that studies using commonly accepted values such as 0.75 derived from theoretical models to extrapolate metabolic data of species to population or community levels should consider the likely variation in exponents that exists in the real world, or seek to encompass such error in their models. This study, as in numerous previous ones, demonstrates that scaling exponents show large, naturally occurring variation, and provides more evidence against the existence of a universal scaling law. © 2012 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A PSS/E 32 model of a real section of the Northern Ireland electrical grid was dynamically controlled with Python 2.5. In this manner data from a proposed wide area monitoring system was simulated. The area is of interest as it is a weakly coupled distribution grid with significant distributed generation. The data was used to create an optimization and protection metric that reflected reactive power flow, voltage profile, thermal overload and voltage excursions. Step changes in the metric were introduced upon the operation of special protection systems and voltage excursions. A wide variety of grid conditions were simulated while tap changer positions and switched capacitor banks were iterated through; with the most desirable state returning the lowest optimization and protection metric. The optimized metric was compared against the metric generated from the standard system state returned by PSS/E. Various grid scenarios were explored involving an intact network and compromised networks (line loss) under summer maximum, summer minimum and winter maximum conditions. In each instance the output from the installed distributed generation is varied between 0 MW and 80 MW (120% of installed capacity). It is shown that in grid models the triggering of special protection systems is delayed by between 1 MW and 6 MW (1.5% to 9% of capacity), with 3.5 MW being the average. The optimization and protection metric gives a quantitative value for system health and demonstrates the potential efficacy of wide area monitoring for protection and control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Renewable energy is high on international and national agendas. Currently, grid-connected photovoltaic (PV) systems are a popular technology to convert solar energy into electricity. Existing PV panels have a relatively low and varying output voltage so that the converter installed between the PVs and the grid should be equipped with high step-up and versatile control capabilities. In addition, the output current of PV systems is rich in harmonics which affect the power quality of the grid. In this paper, a new multi-stage hysteresis control of a step-up DC-DC converter is proposed for integrating PVs into a single-phase power grid. The proposed circuitry and control method is experimentally validated by testing on a 600W prototype converter. The developed technology has significant economic implications and could be applied to many distributed generation (DG) systems, especially for the developing countries which have a large number of small PVs connected to their single-phase distribution network. 

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In multi-terminal high voltage direct current (HVDC) grids, the widely deployed droop control strategies will cause a non-uniform voltage deviation on the power flow, which is determined by the network topology and droop settings. This voltage deviation results in an inconsistent power flow pattern when the dispatch references are changed, which could be detrimental to the operation and seamless integration of HVDC grids. In this paper, a novel droop setting design method is proposed to address this problem for a more precise power dispatch. The effects of voltage deviations on the power sharing accuracy and transmission loss are analysed. This paper shows that there is a trade-off between minimizing the voltage deviation, ensuring a proper power delivery and reducing the total transmission loss in the droop setting design. The efficacy of the proposed method is confirmed by simulation studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of sodium-modification on the catalyst and electrocatalytic properties of a platinum catalyst supported on a YSZ solid electrolyte was studied. Increasing the sodium coverage on the catalyst surface appears to block some of the three-phase boundary (tpb) sites and reduces the rate of the charge transfer reaction. The promotion of the platinum surface reaction (ethylene oxidation) seems to a first approximation to be a function of the rate of oxygen supply or removal to or from the surface irrespective of whether this is contaminated by sodium or not (samples with sodium contamination require a higher overpotential to achieve the same current density as a clean sample because of poisoning in the tpb). At high negative polarisations (oxygen removed from the surface) the sodium contaminated samples show a significant increase in rate, possibly due to the decomposition of e.g. sodium hydroxides and carbonates. © 2012 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We consider the problem of linking web search queries to entities from a knowledge base such as Wikipedia. Such linking enables converting a user’s web search session to a footprint in the knowledge base that could be used to enrich the user profile. Traditional methods for entity linking have been directed towards finding entity mentions in text documents such as news reports, each of which are possibly linked to multiple entities enabling the usage of measures like entity set coherence. Since web search queries are very small text fragments, such criteria that rely on existence of a multitude of mentions do not work too well on them. We propose a three-phase method for linking web search queries to wikipedia entities. The first phase does IR-style scoring of entities against the search query to narrow down to a subset of entities that are expanded using hyperlink information in the second phase to a larger set. Lastly, we use a graph traversal approach to identify the top entities to link the query to. Through an empirical evaluation on real-world web search queries, we illustrate that our methods significantly enhance the linking accuracy over state-of-the-art methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Natural mineral-water interface reactions drive ecosystem/global fluoride (F−) cycling. These small-scale processes prove challenging to monitoring due to mobilization being highly localized and variable; influenced by changing climate, hydrology, dissolution chemistries and pedogenosis. These release events could be captured in situ by the passive sampling technique, diffusive gradients in thin-films (DGT), providing a cost-effective and time-integrated measurement of F− mobilization. However, attempts to develop the method for F− have been unsuccessful due to the very restrictive operational ranges that most F−-absorbents function within. A new hybrid-DGT technique for F− quantification containing a three-phase fine particle composite (Fesingle bondAlsingle bondCe, FAC) adsorbent was developed and evaluated. Sampler response was validated in laboratory and field deployments, passing solution chemistry QC within ionic strength and pH ranges of 0–200 mmol L−1 and 4.3–9.1, respectively, and exhibiting high sorption capacities (98 ± 8 μg cm−2). FAC-DGT measurements adequately predicted up to weeklong averaged in situ F− fluvial fluxes in a freshwater river and F− concentrations in a wastewater treatment flume determined by high frequency active sampling. While, millimetre-scale diffusive fluxes across the sediment-water interface were modeled for three contrasting lake bed sediments from a F−-enriched lake using the new FAC-DGT platform.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O estudo de escoamentos turbulentos em descarregadores em degraus tem sido um desafio para os investigadores. A macro-rugosidade do leito, a ondulação da superfície livre, a intermitência da localização da secção inicial de entrada de ar e o escoamento bi-fásico a jusante da secção inicial de entrada de ar fazem com que a caracterização do escoamento deslizante sobre turbilhões em descarregadores em degraus não seja simples. Actualmente, é possível combinar técnicas de medição fiáveis com simulações numéricas e análise teórica. Nesta dissertação, o estudo experimental baseia-se em resultados experimentais obtidos em duas instalações experimentais: a instalação A, do Laboratório Nacional de Engenharia Civil (LNEC), dotada de um descarregador em degraus com declive de 1V:0.75H e a instalação B, do Instituto Superior Técnico (IST), dotada de um descarregador em degraus com declive de 1V:2H. Uma sonda de ar, um tubo de Pitot modificado e vários hidrómetros permitiram o estudo do escoamento deslizante sobre turbilhões mono- e bifásico ao longo do descarregador em degraus da instalação A. Na bacia de dissipação de energia, a observação visual do escoamento foi auxiliada pelas leituras efectuadas em tomadas de pressão localizadas na soleira da bacia e pelas leituras da altura do escoamento efectuadas em réguas graduadas localizadas nas paredes da bacia. Na instalação B foram utilizados um tubo de Pitot e vários hidrómetros para estudar a região não arejada do escoamento deslizante sobre turbilhões no descarregador em degraus. O estudo numérico é baseado em simulações numéricas da região não arejada do escoamento deslizante sobre turbilhões sobre descarregadores em degraus com o código comercial de CFD FLOW-3D® de modo a reproduzir as condições ensaiadas experimentalmente. As simulações beneficiaram da técnica de blocos múltiplos (multi-block) num sistema de coordenadas cartesianas, da determinação da superfície livre pelo método TruVOF e da utilização de dois modelos de turbulência: os modelos k- e RNG k-. Por último, o estudo teórico consistiu em desenvolver um modelo simplificado 1D para determinar as características hidráulicas principais do trecho não arejado do escoamento deslizante sobre turbilhões em descarregadores em degraus. O modelo foi desenvolvido a partir das equações de Navier-Stokes, conjuntamente com resultados experimentais e numéricos. Os resultados apresentados nesta dissertação contribuem para o conhecimento do escoamento deslizante sobre turbilhões em descarregadores em degraus, nomeadamente na região não arejada, na secção inicial de entrada de ar e na região arejada. A hidráulica dos dissipadores de energia a jusante de descarregadores em degraus, em particular das bacias tipo III do USBR, é também objecto de estudo. Em relação à região não arejada do escoamento em descarregadores com declive acentuado, e com base em resultados experimentais e numéricos, são propostas expressões para estimar o desenvolvimento da altura equivalente de água, da espessura da camada limite, da concentração média de ar, do coeficiente de energia cinética, da dissipação de energia, do factor de resistência e do coeficiente n da fórmula de Manning. São ainda propostas expressões adimensionais para a energia cinética turbulenta e sua dissipação. Para declives moderados, são propostas expressões para estimar o desenvolvimento da altura equivalente de água, do coeficiente de energia cinética e da energia específica residual. São ainda apresentados valores do expoente 1/N da expressão adimensional da distribuição de velocidades, quer para descarregadores com declive acentuado quer com declive moderado. Em conformidade com outros estudos centrados em escoamentos de parede e com derivações teóricas, para a região não arejada do escoamento em descarregadores em degraus de acentuado declive, observa-se que o factor de resistência depende da macro-rugosidade criada pelos degraus e da geometria da secção transversal e que o coeficiente n da fórmula de Manning aumenta com a rugosidade. A descrição estatística da turbulência do escoamento é igualmente explorada, contribuindo para o conhecimento da estrutura do escoamento. Observou-se que para números de Reynolds rugoso não superiores a 6.8x104 a energia cinética turbulência e a sua dissipação cumprem leis de semelhança. Estas expressões adimensionais estão de acordo com os resultados obtidos por outros autores para escoamentos completamente desenvolvidos em canais abertos e no escoamento em rios com leito de gravilha. Em acréscimo, a taxa de dissipação de energia, quer para descarregadores de declive acentuado quer de moderado declive, é baixa. Por último, observa-se que os valores da média temporal da concentração de ar entre 0 e 1 medidos na região não arejada do escoamento dizem respeito não só ao ar capturado entre ondas de água, na zona de ondulação da superfície livre, mas também ao ar emulsionado no escoamento, i.e., sob a forma de bolhas de ar, quando perto da secção média inicial de entrada de ar, devido à diferença entre localizações instantânea e média temporal. Foram revistas metodologias e fórmulas para estimar a localização da secção inicial de entrada de ar e apresentadas expressões para estimar a concentração média de ar e a altura equivalente de água nessa secção. Relativamente à região de escoamento arejado em descarregadores em degraus com declive acentuado, os resultados experimentais apresentados nesta dissertação permitiram estimar a influência da definição da superfície livre nos parâmetros hidráulicos da região do escoamento arejado e estimar a máxima elevação do escoamento nesta região do escoamento. Com base nos resultados experimentais obtidos na bacia de dissipação de energia do tipo III do USBR localizada a jusante do descarregador em degraus da instalação A, observou-se que os perfis da altura piezométrica e da altura do escoamento tendem a seguir o perfil recomendado pelo USBR para bacias tipo III. A excepção ocorre à entrada da bacia, onde as alturas piezométricas apresentadas nesta dissertação excedem largamente as apresentadas pelo USBR. É ainda observado que, tal como entre as bacias tipo I e tipo III do USBR, o ressalto hidráulico estabiliza muito mais rapidamente numa bacia tipo III a jusante de um descarregador em degraus do que uma bacia tipo I a jusante do mesmo descarregador em degraus. Finalmente, observa-se que os blocos de amortecimento a colocar no descarregador não têm influência visível nos resultados da altura piezométrica nem da altura do escoamento ao longo da bacia. Relativamente às simulações numéricas do escoamento não arejado, a proximidade entre resultados experimentais e numéricos permite validar o modelo teórico e a integração numérica usados no FLOW-3D®. As simulações desenvolvidas também mostraram que o modelo de turbulência k- permite representar as características do escoamento não arejado em descarregadores em degraus, uma vez que não foram observadas diferenças significativas entre as simulações com este modelo e com o modelo RNG k-. Finalmente, observou-se que o modelo de entrada de ar usado no FLOW-3D® é válido para estimar a localização da secção inicial de entrada de ar. Por último, a proximidade entre os resultados obtidos da aplicação do modelo teórico desenvolvido no âmbito desta dissertação e os resultados experimentais indica que as hipóteses e simplificações consideradas no desenvolvimento do modelo são adequadas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação Multicélula é um tópico de investigação em rápido crescimento e uma solução promissora para controlar a interferência entre células em sistemas celulares, melhorando a equidade do sistema e aumentando a sua capacidade. Esta tecnologia já está em estudo no LTEAdvanced sob o conceito de coordenação multiponto (COMP). Existem várias abordagens sobre coordenação multicélula, dependendo da quantidade e do tipo de informação partilhada pelas estações base, através da rede de suporte (backhaul network), e do local onde essa informação é processada, i.e., numa unidade de processamento central ou de uma forma distribuída em cada estação base. Nesta tese, são propostas técnicas de pré-codificação e alocação de potência considerando várias estratégias: centralizada, todo o processamento é feito na unidade de processamento central; semidistribuída, neste caso apenas parte do processamento é executado na unidade de processamento central, nomeadamente a potência alocada a cada utilizador servido por cada estação base; e distribuída em que o processamento é feito localmente em cada estação base. Os esquemas propostos são projectados em duas fases: primeiro são propostas soluções de pré-codificação para mitigar ou eliminar a interferência entre células, de seguida o sistema é melhorado através do desenvolvimento de vários esquemas de alocação de potência. São propostas três esquemas de alocação de potência centralizada condicionada a cada estação base e com diferentes relações entre desempenho e complexidade. São também derivados esquemas de alocação distribuídos, assumindo que um sistema multicelular pode ser visto como a sobreposição de vários sistemas com uma única célula. Com base neste conceito foi definido uma taxa de erro média virtual para cada um desses sistemas de célula única que compõem o sistema multicelular, permitindo assim projectar esquemas de alocação de potência completamente distribuídos. Todos os esquemas propostos foram avaliados em cenários realistas, bastante próximos dos considerados no LTE. Os resultados mostram que os esquemas propostos são eficientes a remover a interferência entre células e que o desempenho das técnicas de alocação de potência propostas é claramente superior ao caso de não alocação de potência. O desempenho dos sistemas completamente distribuídos é inferior aos baseados num processamento centralizado, mas em contrapartida podem ser usados em sistemas em que a rede de suporte não permita a troca de grandes quantidades de informação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a non-invasive approach for diagnosing winding insulation failures in three-phase transformers, which is based on the on-line monitoring of the primary and secondary current Park's Vector. Experimental and simulated results demonstrate the effectiveness of the proposed technique, for detecting winding inter-turn insulation faults in operating three-phase transformers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the development of a new approach for diagnosing the occurrence of inter-turn short-circuits in the windings of three-phase transformers, which is based on the on-line monitoring of the on-load exciting current Park's Vector patterns. Experimental and simulated results demonstrate the effectiveness of the proposed technique for detecting winding inter-turn insulation faults in operating three-phase transformers.