999 resultados para Test tailoring, specifica tecnica, kurtosis, danno a fatica
Resumo:
In this thesis, the components important for testing work and organisational test process are identified and analysed. This work focuses on the testing activities in reallife software organisations, identifying the important test process components, observing testing work in practice, and analysing how the organisational test process could be developed. Software professionals from 14 different software organisations were interviewed to collect data on organisational test process and testing‐related factors. Moreover, additional data on organisational aspects was collected with a survey conducted on 31 organisations. This data was further analysed with the Grounded Theory method to identify the important test process components, and to observe how real‐life test organisations develop their testing activities. The results indicate that the test management at the project level is an important factor; the organisations do have sufficient test resources available, but they are not necessarily applied efficiently. In addition, organisations in general are reactive; they develop their process mainly to correct problems, not to enhance their efficiency or output quality. The results of this study allows organisations to have a better understanding of the test processes, and develop towards better practices and a culture of preventing problems, not reacting to them.
Resumo:
This paper presents the design for a graphical parameter editor for Testing and Test Control Notation 3 (TTCN-3) test suites. This work was done in the context of OpenTTCN IDE, a TTCN-3 development environment built on top of the Eclipse platform. The design presented relies on an additional parameter editing tab added to the launch configurations for test campaigns. This parameter editing tab shows the list of editable parameters and allows opening editing components for the different parameters. Each TTCN-3 primitive type will have a specific editing component providing tools to ease modification of values of that type.
Resumo:
Quantifying soil evaporation is required on studies of soil water balance and applications aiming to improve water use efficiency by crops. The performance of a microlysimeter (ML) to measure soil evaporation under irrigation and non-irrigation was evaluated. The MLs were constructed using PVC tubes, with dimensions of 100 mm inner diameter, 150 mm depth and 2.5 mm wall thickness. Four MLs were uniformly distributed on the soil surface of two weighing lysimeters conducted under bare soil, previously installed at Iapar, in Londrina, PR, Brazil. The lysimeters had 1.4 m width, 1.9 m length and 1.3 m depth and were conducted with and without irrigation. Evaporation measurements by MLs (E ML) were compared with measurements by lysimeters (E L) during four different periods in the year. Differences between E ML and E L were small either for low or high atmospheric demand and also for either irrigated or non-irrigated conditions, which indicates that the ML tested here is suitable for measurement of soil evaporation.
Resumo:
The rural electrification is characterized by geographical dispersion of the population, low consumption, high investment by consumers and high cost. Moreover, solar radiation constitutes an inexhaustible source of energy and in its conversion into electricity photovoltaic panels are used. In this study, equations were adjusted to field conditions presented by the manufacturer for current and power of small photovoltaic systems. The mathematical analysis was performed on the photovoltaic rural system I-100 from ISOFOTON, with power 300 Wp, located at the Experimental Farm Lageado of FCA/UNESP. For the development of such equations, the circuitry of photovoltaic cells has been studied to apply iterative numerical methods for the determination of electrical parameters and possible errors in the appropriate equations in the literature to reality. Therefore, a simulation of a photovoltaic panel was proposed through mathematical equations that were adjusted according to the data of local radiation. The results have presented equations that provide real answers to the user and may assist in the design of these systems, once calculated that the maximum power limit ensures a supply of energy generated. This real sizing helps establishing the possible applications of solar energy to the rural producer and informing the real possibilities of generating electricity from the sun.
Resumo:
Among studies focused on increasing soybean grain yield, the ones related to sowing process are the most significant. Considering that soybean has an epigeal emergence, it becomes difficult to hint at the length covered by hypocotyl up to soil surface, or the actual planting depth. This study aimed to find an indicator that allows the identification of an ideal soybean planting depth. For this purpose, two complementary assays has been carried out in a greenhouse. The first aimed to identify structures that could be indicators of seed planting depth, on a medium-textured soil from Campos Gerais region, in the state of Paraná, Brazil. Spring NK 8350 cultivar seeds were sown at five theoretical depths (1, 2, 3, 4 and 5 cm). As seedlings emerged, the “differentiation zone” and the “root curve” depths were measured. The second assay was the validation of the suggested indicators in assay 1 from two soils, one medium-textured and one clay-textured. For this assay, it was used BRS 232. Both the methodologies showed high correlation with the theoretical planting depth. Although their correlation coefficient values were close, the differentiation zone appeared to be the most efficient reference with less planting depth overestimation.
Resumo:
Em ambos os hospitais universitários de Pernambuco, o tratamento de escolha para portadores de esquistossomose hepatoesplênica (EHE) com antecedente de hemorragia digestiva alta (HDA) por rotura de varizes de esôfago (VE) é a esplenectomia associada à ligadura da veia gástrica esquerda (ELGE); porém, o impacto desta cirurgia sobre a pressão das VE, provavelmente, o parâmetro que melhor se correlaciona com o risco de recidiva hemorrágica, ainda não foi estudado. Com a introdução, em nosso meio, de técnica não-invasiva de medição da pressão das VE, isto tornou-se possível, com mínimos riscos, tomando-se o objetivo do presente estudo. A ELGE foi empregada em vinte portadores de EHE com antecedentes de HDA. A pressão das VE foi medida através do método endoscópico não-invasivo do balão pneumático, antes da cirurgia, e estes valores comparados com novas medições realizadas cinco a oito dias após. A pressão nas VE no pré-operatório variou entre 20,0 e 28,7mmHg (média de 24,35± 2,36 mmHg). Não houve correlação da pressão com o calibre das VE. No pós-operatório (PO), observou-se uma queda significante na pressão das VE, que variou entre 14,6 e 21,5 mmHg (média 17,29± 1,75 mmHg, p<0,001). Os resultados do presente trabalho confirmam as idéias que fundamentam a indicação da ELGE em portadores de EHE com antecedente de HDA. Esta cirurgia determina, pelo menos a curto prazo e na ampla maioria dos casos, uma redução na pressão das VE reduzindo o risco de recidiva de HDA.
Resumo:
CHARGE syndrome, Sotos syndrome and 3p deletion syndrome are examples of rare inherited syndromes that have been recognized for decades but for which the molecular diagnostics only have been made possible by recent advances in genomic research. Despite these advances, development of diagnostic tests for rare syndromes has been hindered by diagnostic laboratories having limited funds for test development, and their prioritization of tests for which a (relatively) high demand can be expected. In this study, the molecular diagnostic tests for CHARGE syndrome and Sotos syndrome were developed, resulting in their successful translation into routine diagnostic testing in the laboratory of Medical Genetics (UTUlab). In the CHARGE syndrome group, mutation was identified in 40.5% of the patients and in the Sotos syndrome group, in 34%, reflecting the use of the tests in routine diagnostics in differential diagnostics. In CHARGE syndrome, the low prevalence of structural aberrations was also confirmed. In 3p deletion syndrome, it was shown that small terminal deletions are not causative for the syndrome, and that testing with arraybased analysis provides a reliable estimate of the deletion size but benign copy number variants complicate result interpretation. During the development of the tests, it was discovered that finding an optimal molecular diagnostic strategy for a given syndrome is always a compromise between the sensitivity, specificity and feasibility of applying a new method. In addition, the clinical utility of the test should be considered prior to test development: sometimes a test performing well in a laboratory has limited utility for the patient, whereas a test performing poorly in the laboratory may have a great impact on the patient and their family. At present, the development of next generation sequencing methods is changing the concept of molecular diagnostics of rare diseases from single tests towards whole-genome analysis.
Resumo:
Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.
Resumo:
The Repair of segmental defects in load-bearing long bones is a challenging task because of the diversity of the load affecting the area; axial, bending, shearing and torsional forces all come together to test the stability/integrity of the bone. The natural biomechanical requirements for bone restorative materials include strength to withstand heavy loads, and adaptivity to conform into a biological environment without disturbing or damaging it. Fiber-reinforced composite (FRC) materials have shown promise, as metals and ceramics have been too rigid, and polymers alone are lacking in strength which is needed for restoration. The versatility of the fiber-reinforced composites also allows tailoring of the composite to meet the multitude of bone properties in the skeleton. The attachment and incorporation of a bone substitute to bone has been advanced by different surface modification methods. Most often this is achieved by the creation of surface texture, which allows bone growth, onto the substitute, creating a mechanical interlocking. Another method is to alter the chemical properties of the surface to create bonding with the bone – for example with a hydroxyapatite (HA) or a bioactive glass (BG) coating. A novel fiber-reinforced composite implant material with a porous surface was developed for bone substitution purposes in load-bearing applications. The material’s biomechanical properties were tailored with unidirectional fiber reinforcement to match the strength of cortical bone. To advance bone growth onto the material, an optimal surface porosity was created by a dissolution process, and an addition of bioactive glass to the material was explored. The effects of dissolution and orientation of the fiber reinforcement were also evaluated for bone-bonding purposes. The Biological response to the implant material was evaluated in a cell culture study to assure the safety of the materials combined. To test the material’s properties in a clinical setting, an animal model was used. A critical-size bone defect in a rabbit’s tibia was used to test the material in a load-bearing application, with short- and long-term follow-up, and a histological evaluation of the incorporation to the host bone. The biomechanical results of the study showed that the material is durable and the tailoring of the properties can be reproduced reliably. The Biological response - ex vivo - to the created surface structure favours the attachment and growth of bone cells, with the additional benefit of bioactive glass appearing on the surface. No toxic reactions to possible agents leaching from the material could be detected in the cell culture study when compared to a nontoxic control material. The mechanical interlocking was enhanced - as expected - with the porosity, whereas the reinforcing fibers protruding from the surface of the implant gave additional strength when tested in a bone-bonding model. Animal experiments verified that the material is capable of withstanding load-bearing conditions in prolonged use without breaking of the material or creating stress shielding effects to the host bone. A Histological examination verified the enhanced incorporation to host bone with an abundance of bone growth onto and over the material. This was achieved with minimal tissue reactions to a foreign body. An FRC implant with surface porosity displays potential in the field of reconstructive surgery, especially regarding large bone defects with high demands on strength and shape retention in load-bearing areas or flat bones such as facial / cranial bones. The benefits of modifying the strength of the material and adjusting the surface properties with fiber reinforcement and bone-bonding additives to meet the requirements of different bone qualities are still to be fully discovered.
Resumo:
kuv., 8 x 15 cm
Resumo:
kuv., 10 x 15 cm
Resumo:
kuv., 10 x 15 cm