995 resultados para Steven J. Dempsey


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Motorcycle crash related injuries and deaths are increasing rapidly in many African nations. Utilizing conspicuity measures, such as wearing reflective, fluorescent safety vests, are effective as crash prevention strategies. Furthermore, use of some conspicuity measures is mandated by law among motorcycle-taxi drivers in Tanzania. Nonetheless, uptake remains low. Locally appropriate strategies to improve crash preventative behaviors are needed.

To explore whether use of conspicuity measures could be improved through eliminating cost-barriers, we tested a distribution strategy involving the provision of free motorcycle safety vests among a population of motorcycle-taxi drivers in Moshi, Tanzania. We conducted a cluster randomized controlled trial among 180 motorcycle-taxi drivers in which half of the participants (90) were randomized to the intervention arm and received a free reflective vest. The other half of the participants (90) were randomized to the control arm and did not receive free vests. Whether motorcycle taxi drivers used the reflective vest was then unobtrusively observed on city streets over a period of three months.

Mixed-effects logistic regression was used to estimate differential uptake of the vests between trial arms. At baseline, 3.3% of individuals in both arms used a reflective vest. In three months of follow-up, 79 drivers in the intervention arm and 82 drivers in the control arm were able to be observed. In the intervention arm the average proportion of observations during which drivers were observed to be using a reflective vest was 9.5%, compared to 2.0% in the control arm (odds ratio: 5.5, 95% confidence interval: 1.1-26.9, p-value: 0.04). Distribution of free reflective vests did lead to an increase in vest usage, however, the increase was minimal. Removing economic barriers alone appears insufficient to adequately improve adherence to conspicuity measures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gemstone Team ANTIDOTE

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a novel system to be used in the rehabilitation of patients with forearm injuries. The system uses surface electromyography (sEMG) recordings from a wireless sleeve to control video games designed to provide engaging biofeedback to the user. An integrated hardware/software system uses a neural net to classify the signals from a user’s muscles as they perform one of a number of common forearm physical therapy exercises. These classifications are used as input for a suite of video games that have been custom-designed to hold the patient’s attention and decrease the risk of noncompliance with the physical therapy regimen necessary to regain full function in the injured limb. The data is transmitted wirelessly from the on-sleeve board to a laptop computer using a custom-designed signal-processing algorithm that filters and compresses the data prior to transmission. We believe that this system has the potential to significantly improve the patient experience and efficacy of physical therapy using biofeedback that leverages the compelling nature of video games.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biogas is a mixture of methane and other gases. In its crude state, it contains carbon dioxide (CO2) that reduces its energy efficiency and hydrogen sulfide (H2S) that is toxic and highly corrosive. Because chemical methods of removal are expensive and environmentally hazardous, this project investigated an algal-based system to remove CO2 from biogas. An anaerobic digester was used to mimic landfill biogas. Iron oxide and an alkaline spray were used to remove H2S and CO2 respectively. The CO2-laden alkali solution was added to a helical photobioreactor where the algae metabolized the dissolved CO2 to generate algal biomass. Although technical issues prevented testing of the complete system for functionality, cost analysis was completed and showed that the system, in its current state, is not economically feasible. However, modifications may reduce operation costs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A solar cell relies on its ability to turn photons into current. Because short wavelength photons are typically absorbed near the top surface of a cell, the generated charge carriers recombine before being collected. But when a layer of quantum dots (nanoscale semiconductor particles) is placed on top of the cell, it absorbs short wavelength photons and emits them into the cell at longer wavelengths, which enables more efficient carrier collection. However, the resulting power conversion efficiency of the system depends critically on the quantum dot luminescence efficiency – the nature of this relationship was previously unknown. Our calculations suggest that a quantum dot layer must have high luminescence efficiency (at least 80%) to improve the current output of existing photovoltaic (PV) cells; otherwise, it may worsen the cell’s efficiency. Our quantum dot layer (using quantum dots with over 85% quantum yield) slightly reduced the efficiency of our PV cells. We observed a decrease in short circuit current of a commercial-grade cell from 0.1977 A to 0.1826 A, a 7.6% drop, suggesting that improved optical coupling from the quantum dot emission into the solar cell is needed. With better optical coupling, we predict current enhancements between ~6% and ~8% for a solar cell that already has an antireflection coating. Such improvements could have important commercial impacts if the coating could be deployed in a scalable fashion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Intracellular cytokine staining combined with flow cytometry is one of a number of assays designed to assess T-cell immune responses. It has the specific advantage of enabling the simultaneous assessment of multiple phenotypic, differentiation and functional parameters pertaining to responding T-cells, most notably, the expression of multiple effector cytokines. These attributes make the technique particularly suitable for the assessment of T-cell immune responses induced by novel tuberculosis vaccines in clinical trials. However, depending upon the particular nature of a given vaccine and trial setting, there are approaches that may be taken at different stages of the assay that are more suitable than other alternatives. In this paper, the Tuberculosis Vaccine Initiative (TBVI) TB Biomarker Working group reports on efforts to assess the conditions that will determine when particular assay approaches should be employed. We have found that choices relating to the use of fresh whole blood or peripheral blood mononuclear cells (PBMC) and frozen PBMC; use of serum-containing or serum-free medium; length of stimulation period and use of co-stimulatory antibodies can all affect the sensitivity of intracellular cytokine assays. In the case of sample material, frozen PBMC, despite some loss of sensitivity, may be more advantageous for batch analysis. We also recommend that for multi-site studies, common antibody panels, gating strategies and analysis approaches should be employed for better comparability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the status of the 2008 edition of the HITRAN molecular spectroscopic database. The new edition is the first official public release since the 2004 edition, although a number of crucial updates had been made available online since 2004. The HITRAN compilation consists of several components that serve as input for radiative-transfer calculation codes: individual line parameters for the microwave through visible spectra of molecules in the gas phase; absorption cross-sections for molecules having dense spectral features, i.e. spectra in which the individual lines are not resolved; individual line parameters and absorption cross-sections for bands in the ultraviolet; refractive indices of aerosols, tables and files of general properties associated with the database; and database management software. The line-by-line portion of the database contains spectroscopic parameters for 42 molecules including many of their isotopologues. © 2009 Elsevier Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the status circa 2001, of the HITRAN compilation that comprises the public edition available through 2001. The HITRAN compilation consists of several components useful for radiative transfer calculation codes: high-resolution spectroscopic parameters of molecules in the gas phase, absorption cross-sections for molecules with very dense spectral features, aerosol refractive indices, ultraviolet line-by-line parameters and absorption cross-sections, and associated database management software. The line-by-line portion of the database contains spectroscopic parameters for 38 molecules and their isotopologues and isotopomers suitable for calculating atmospheric transmission and radiance properties. Many more molecular species are presented in the infrared cross-section data than in the previous edition, especially the chlorofluorocarbons and their replacement gases. There is now sufficient representation so that quasi-quantitative simulations can be obtained with the standard radiance codes. In addition to the description and justification of new or modified data that have been incorporated since the last edition of HITRAN (1996), future modifications are indicated for cases considered to have a significant impact on remote-sensing experiments. © 2003 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

info:eu-repo/semantics/published

Relevância:

10.00% 10.00%

Publicador:

Resumo:

info:eu-repo/semantics/published

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In recent years, evacuation models have been increasingly applied in an attempt to understand the outcome of emergency egress scenarios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Traditionally, when designing a ship the driving issues are seen to be powering, stability, strength and seakeeping. Issues related to ship operations and evolutions are investigated later in the design process, within the constraint of a fixed layout. This can result in operational inefficiencies and limitations, excessive crew numbers and potentially hazardous situations. University College London and the University of Greenwich are in the final year of a three year EPSRC funded research project to integrate the simulation of personnel movement into early stage ship design. This allows the assessment of onboard operations while the design is still amenable to change. The project brings together the University of Greenwich developed maritimeEXODUS personnel movement simulation software and the SURFCON implementation of the Design Building Block approach to early stage ship design, which originated with the UCL Ship Design Research team. Central to the success of this project is the definition of a suitable series of Naval Combatant Human Performance Metrics which can be used to assess the performance of the design in different operational scenarios. The paper outlines the progress made on deriving the human performance metric from human factors criteria measured in simulations and their incorporation into a Behavioural Matrix for analysis. It describes the production of a series of SURFCON ship designs based on the RN Type 22 Batch 3 frigate, and their analysis using the PARAMARINE and maritimeEXODUS software. Conclusions to date will be presented on the integration of personnel movement simulation into the preliminary ship design process.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The passenger response time distributions adopted by the International Maritime Organisation (IMO)in their assessment of the assembly time for passanger ships involves two key assumptions. The first is that the response time distribution assumes the form of a uniform random distribution and the second concerns the actual response times. These two assumptions are core to the validity of the IMO analysis but are not based on real data, being the recommendations of an IMO committee. In this paper, response time data collected from assembly trials conducted at sea on a real passanger vessel using actual passangers are presented and discussed. Unlike the IMO specified response time distributions, the data collected from these trials displays a log-normal distribution, similar to that found in land based environments. Based on this data, response time distributions for use in the IMO assesmbly for the day and night scenarios are suggested