896 resultados para Spinal loads
Disseminated Cerebral and Intradural Extramedullary Spinal Nocardiosis in an Immunocompetent Patient
Resumo:
Disseminated nocardiosis of the central nervous system (CNS) has been rarely reported, especially in the immunocompetent patient. We report a case of cerebral and cervical intradural extramedullary nocardiosis likely to have been the result of disseminated spread from a pulmonary infective focus. Attempts at tissue biopsy and culture of the initial cerebral and pulmonary lesions both failed to yield the diagnosis. Interval development of a symptomatic intradural extramedullary cervical lesion resulted in open biopsy and an eventual diagnosis of nocardiosis was made. We highlight the diagnostic dilemma and rarity of spinal nocardial dissemination in an immunocompetent individual.
Resumo:
International audience
Resumo:
Spinal cord injury (SCI) is a devastating condition, which results from trauma to the cord, resulting in a primary injury response which leads to a secondary injury cascade, causing damage to both glial and neuronal cells. Following trauma, the central nervous system (CNS) fails to regenerate due to a plethora of both intrinsic and extrinsic factors. Unfortunately, these events lead to loss of both motor and sensory function and lifelong disability and care for sufferers of SCI. There have been tremendous advancements made in our understanding of the mechanisms behind axonal regeneration and remyelination of the damaged cord. These have provided many promising therapeutic targets. However, very few have made it to clinical application, which could potentially be due to inadequate understanding of compound mechanism of action and reliance on poor SCI models. This thesis describes the use of an established neural cell co-culture model of SCI as a medium throughput screen for compounds with potential therapeutic properties. A number of compounds were screened which resulted in a family of compounds, modified heparins, being taken forward for more intense investigation. Modified heparins (mHeps) are made up of the core heparin disaccharide unit with variable sulphation groups on the iduronic acid and glucosamine residues; 2-O-sulphate (C2), 6-O-sulphate (C6) and N-sulphate (N). 2-O-sulphated (mHep6) and N-sulphated (mHep7) heparin isomers were shown to promote both neurite outgrowth and myelination in the SCI model. It was found that both mHeps decreased oligodendrocyte precursor cell (OPC) proliferation and increased oligodendrocyte (OL) number adjacent to the lesion. However, there is a difference in the direct effects on the OL from each of the mHeps; mHep6 increased myelin internode length and mHep7 increased the overall cell size. It was further elucidated that these isoforms interact with and mediate both Wnt and FGF signalling. In OPC monoculture experiments FGF2 treated OPCs displayed increased proliferation but this effect was removed when co-treated with the mHeps. Therefore, suggesting that the mHeps interact with the ligand and inhibit FGF2 signalling. Additionally, it was shown that both mHeps could be partially mediating their effects through the Wnt pathway. mHep effects on both myelination and neurite outgrowth were removed when co-treated with a Wnt signalling inhibitor, suggesting cell signalling mediation by ligand immobilisation and signalling activation as a mechanistic action for the mHeps. However, the initial methods employed in this thesis were not sufficient to provide a more detailed study into the effects the mHeps have on neurite outgrowth. This led to the design and development of a novel microfluidic device (MFD), which provides a platform to study of axonal injury. This novel device is a three chamber device with two chambers converging onto a central open access chamber. This design allows axons from two points of origin to enter a chamber which can be subjected to injury, thus providing a platform in which targeted axonal injury and the regenerative capacity of a compound study can be performed. In conclusion, this thesis contributes to and advances the study of SCI in two ways; 1) identification and investigation of a novel set of compounds with potential therapeutic potential i.e. desulphated modified heparins. These compounds have multiple therapeutic properties and could revolutionise both the understanding of the basic pathological mechanisms underlying SCI but also be a powered therapeutic option. 2) Development of a novel microfluidic device to study in greater detail axonal biology, specifically, targeted axonal injury and treatment, providing a more representative model of SCI than standard in vitro models. Therefore, the MFD could lead to advancements and the identification of factors and compounds relating to axonal regeneration.
Resumo:
Background: Intrathecal adjuvants are added to local anaesthetics to improve the quality of neuraxial blockade and prolong the duration of analgesia during spinal anaesthesia. Used intrathecally, fentanyl improves the quality of spinal blockade as compared to plain bupivacaine and confers a short duration of post-operative analgesia. Intrathecal midazolam as an adjuvant has been used and shown to improve the quality of spinal anaesthesia and prolong the duration of post-operative analgesia. No studies have been done comparing intrathecal fentanyl with bupivacaine and intrathecal 2 mg midazolam with bupivacaine. Objective: To compare the effect of intrathecal 2 mg midazolam to intrathecal 20 micrograms fentanyl when added to 2.6 ml of 0.5% hyperbaric bupivacaine, on post-operative pain, in patients undergoing lower limb orthopaedic surgery under spinal anaesthesia. Methods: A total of 40 patients undergoing lower limb orthopaedic surgery under spinal anaesthesia were randomized to two groups. Group 1: 2.6mls 0.5% hyperbaric bupivacaine with 0.4mls (20micrograms) fentanyl Group 2: 2.6mls of 0.5% hyperbaric bupivacaine with 0.4mls (2mg) midazolam Results: The duration of effective analgesia was longer in the midazolam group (384.05 minutes) as compared to the fentanyl group (342.6 minutes). There was no significant difference (P 0.4047). The time to onset was significantly longer in midazolam group 17.1 minutes as compared to the fentanyl group 13.2 minutes (P 0.023). The visual analogue score at rescue was significantly lower in the midazolam group (5.55) as compared to the fentanyl group 6.35 (P - 0.043). Conclusion: On the basis of the results of this study, there was no significant difference in the duration of effective analgesia between adjuvant intrathecal 2 mg midazolam as compared to intrathecal 20 micrograms fentanyl for patients undergoing lower limb orthopaedic surgery.
Resumo:
Electrical neuromodulation of lumbar segments improves motor control after spinal cord injury in animal models and humans. However, the physiological principles underlying the effect of this intervention remain poorly understood, which has limited the therapeutic approach to continuous stimulation applied to restricted spinal cord locations. Here we developed stimulation protocols that reproduce the natural dynamics of motoneuron activation during locomotion. For this, we computed the spatiotemporal activation pattern of muscle synergies during locomotion in healthy rats. Computer simulations identified optimal electrode locations to target each synergy through the recruitment of proprioceptive feedback circuits. This framework steered the design of spatially selective spinal implants and real-time control software that modulate extensor and flexor synergies with precise temporal resolution. Spatiotemporal neuromodulation therapies improved gait quality, weight-bearing capacity, endurance and skilled locomotion in several rodent models of spinal cord injury. These new concepts are directly translatable to strategies to improve motor control in humans.
Resumo:
Background: Spinal anaesthesia is the standard of care for elective caesarean delivery. It has advantages over general anaesthesia. However the sympathetic blockade induced by spinal anaesthesia results in an 80 percent incidence of hypotension without prophylactic management. Current evidence supports co-loading with intravenous fluids in conjunction with the use of vasopressors as the most effective way to prevent and treat the hypotension. Phenylephrine is the accepted vasopressor of choice in the parturient. A prophylactic phenylephrine infusion combined with a fluid co-load is proven to be an effective and safe method of maintaining maternal hemodynamic stability. While most published studies have assessed the effectiveness of a prophylactic phenylephrine fixed dose infusion, few studies have assessed the effect of a prophylactic phenylephrine weight adjusted dose infusion on maintaining maternal hemodynamic stability following spinal anesthesia for a cesarean delivery. Objective: To compare the incidence of hypotension between women undergoing elective caesarean section under spinal anaesthesia, receiving prophylactic phenylephrine infusion at a fixed dose of 37.5 micrograms per minute versus a weight adjusted dose of 0.5 micrograms per kilogram per minute. Methods: One hundred and eight patients scheduled for non-urgent caesarean section under spinal anaesthesia were randomized into 2 groups; control group and intervention group using a computer generated table of numbers. Control group; Received prophylactic phenylephrine fixed dose infusion at 37.5 micrograms per minute. Intervention group; Received prophylactic phenylephrine weight adjusted dose infusion at 0.5 micrograms per kilogram per minute Results: The two groups had similar baseline characteristics in terms of ; Age, sex, weight and height. There was a 35.2% incidence of hypotension in the fixed dose group and an 18.6% incidence of hypotension in the weight adjusted dose group. This difference was found to be of borderline statistical significance p-value 0.05, and the difference in the incidence rates between the two groups was found to be statistically significant p= 0.03. The difference in the incidence of reactive hypertension and bradycardia between the two groups was not statistically significant: p-value of 0.19 for reactive hypertension and p-value of 0.42 for the incidence of bradycardia. There was also no statistically significant difference in the use of phenylephrine boluses, use of atropine, intravenous fluid used and the number of times the infusion was stopped. Conclusion: Among this population, the incidence of hypotension was significantly less in the weight adjusted dose group than in the fixed dose group. There was no difference in the number of physician interventions required to keep the blood pressure within 20% of baseline, and no difference in the proportion of reactive hypertension or bradycardia between the two groups. Administering prophylactic phenylephrine infusion at a weight adjusted dose of 0.5 micrograms per kilogram per minute results in a lower incidence of hypotension compared to its administration at a fixed dose of 37.5 micrograms per minute.
Resumo:
Purpose: To investigate the effect of Dipsacus asperoides (Xue Duan), a traditional Chinese medicine, on rats with spinal cord injury (SCI). Methods: In this study a total of 40 adult rats were used after inducing SCI where Xue Duan was applied on experimental group and phosphate-buffered saline (PBS) was administered in corresponding control groups. Intraperitoneal administration of both compounds for a period of four weeks (28 days) was carried out at a dose of 10 mg/kg/day. Bright field microscopy was performed on the tissues. Results: Bright Field microscopy of tissue sections showed significant reduction in cavity area that resulted from injury, that is from 0.19 ± 0.05 mm2 to 0.09 ± 0.03 mm2 (p < 0.01) in untreated and treated groups respectively. Similarly western blotting results showed a decrease in the expression of NF-kB p65 and I-kBα (p < 0.01). These two compounds are important in increasing secondary pathophysiology in SCI. The results for MPO activity also revealed significantly reduced infiltration of leukocytes to the injury site (p < 0.01). Conclusion: This study reveals the positive effect of the plant material in reducing inflammation in rats with traumatic SCI.
Resumo:
Purpose: To examine the protective effects of resveratrol (RESV) against spinal cord ischemic reperfusion (SCIR) injury. Methods: Forty-eight male rats were divided into six groups: sham-operated (control-I), SCIR-treated (SCIR-II), rats receiving 20 mg/kg of RESV with SCIR (RESV 20+SCIR-III), rats receiving 40 mg/kg of RESV with SCIR (RESV 40+SCIR-IV), rats receiving 60 mg/kg of RESV with SCIR (RESV 60+SCIR-V), and rats receiving 50 mg/kg of methylprednisolone (MP) with SCIR (MP + SCIR-VI), for 7 days prior to IR (pre-treatment) and 7 days after IR (post-treatment). Results: The levels of oxidative markers (TBARS, MPO) and inflammatory markers (IL-1β, IL-6, TNF-α, and NF-p65) were concomitantly suppressed in RESV-treated rats, which showed improved locomotor function. A pronounced increase in the activities of antioxidant enzymes (SOD, CAT and GSH) was noted in the RESV group compared with the MP and SCIR groups. RESV and MP supplementation increased neuronal count with decreased nuclear degeneration. RESV (40 mg) exhibited greater protective effect than 20 mg and 60 mg of RESV and 50 mg of MP. Conclusion: The results show the neurotherapeutic potential of RESV (40 mg) to attenuate oxidative stress and the inflammatory response to SCIR injury.
Resumo:
Purpose: To prepare hydrogels loaded with epicatechin, a strong antioxidant, anti-inflammatory, and neuroprotective tea flavonoid, and characterise them in situ as a vehicle for prolonged and safer drug delivery in patients with post-traumatic spinal cord injury. Methods: Five in situ gel formulations were prepared using chitosan and evaluated in terms of their visual appearance, clarity, pH, viscosity, and in vitro drug release. In vivo anti-inflammatory activity was determined and compared with 2 % piroxicam gel as standard. Motor function activity in a rat model of spinal injury was examined comparatively with i.v. methylprednisolone as standard. Results: The N-methyl pyrrolidone solution (containing 1 % w/w epicatechin with 2 to 10 % w/w chitosan) of the in situ gel formulation had a uniform pH in the range of 4.01 ± 0.12 to 4.27 ± 0.02. High and uniform drug loading, ranging from 94.48 ± 1.28 to 98.08 ± 1.24 %, and good in vitro drug release (79.48 ± 2.84 to 96.48 ± 1.02 % after 7 days) were achieved. The in situ gel prepared from 1 % epicatechin and 2 % chitosan (E5) showed the greatest in vivo anti-inflammatory activity (60.58 % inhibition of paw oedema in standard carrageenan-induced hind rat paw oedema model, compared with 48.08 % for the standard). The gels showed significant therapeutic effectiveness against post-traumainduced spinal injury in rats. E5 elicited maximum motor activity (horizontal bar test) in the spinal injury rat model; the rats that received E5 treatment produced an activity score of 3.62 ± 0.02 at the end of 7 days, compared with 5.0 ± 0.20 following treatment with the standard. Conclusion: In situ epicatechin-loaded gel exhibits significant neuroprotective and anti-inflammatory effects, and therefore can potentially be used for prolonged and safe drug delivery in patients with traumatic spinal cord injury.
Resumo:
Purpose: To improve the effectiveness and reduce the systemic side effects of methylprednisolone in traumatic spinal injuries, its polymeric implants were prepared using chitosan and sodium alginate as the biocompatible polymers. Methods: Implants of methylprednisolone sodium succinate (MPSS) were prepared by molding the drug-loaded polymeric mass obtained after ionotropic gelation method. The prepared implants were evaluated for drug loading, in vitro drug release and in vivo performance in traumatic spinal-injury rat model with paraplegia. Results: All the implant formulations were light pale solid matrix with smooth texture. Implants showed 86.56 ± 2.07 % drug loading. Drug release was 89.29 ± 1.25 % at the end of 7 days. Motor function was evaluated in traumatic spinal injury-induced rats in terms of its movement on the horizontal bar. At the end of 7 days, the test group showed the activity score (4.75 ± 0.02) slightly higher than that of standard (4.62 ± 0.25), but the difference was not statistically different (p > 0.05). Conclusion: MPSS-loaded implants produces good recovery in traumatic spinal-injury rats.
Resumo:
Buildings and other infrastructures located in the coastal regions of the US have a higher level of wind vulnerability. Reducing the increasing property losses and causalities associated with severe windstorms has been the central research focus of the wind engineering community. The present wind engineering toolbox consists of building codes and standards, laboratory experiments, and field measurements. The American Society of Civil Engineers (ASCE) 7 standard provides wind loads only for buildings with common shapes. For complex cases it refers to physical modeling. Although this option can be economically viable for large projects, it is not cost-effective for low-rise residential houses. To circumvent these limitations, a numerical approach based on the techniques of Computational Fluid Dynamics (CFD) has been developed. The recent advance in computing technology and significant developments in turbulence modeling is making numerical evaluation of wind effects a more affordable approach. The present study targeted those cases that are not addressed by the standards. These include wind loads on complex roofs for low-rise buildings, aerodynamics of tall buildings, and effects of complex surrounding buildings. Among all the turbulence models investigated, the large eddy simulation (LES) model performed the best in predicting wind loads. The application of a spatially evolving time-dependent wind velocity field with the relevant turbulence structures at the inlet boundaries was found to be essential. All the results were compared and validated with experimental data. The study also revealed CFD’s unique flow visualization and aerodynamic data generation capabilities along with a better understanding of the complex three-dimensional aerodynamics of wind-structure interactions. With the proper modeling that realistically represents the actual turbulent atmospheric boundary layer flow, CFD can offer an economical alternative to the existing wind engineering tools. CFD’s easy accessibility is expected to transform the practice of structural design for wind, resulting in more wind-resilient and sustainable systems by encouraging optimal aerodynamic and sustainable structural/building design. Thus, this method will help ensure public safety and reduce economic losses due to wind perils.
Resumo:
Efficient and reliable techniques for power delivery and utilization are needed to account for the increased penetration of renewable energy sources in electric power systems. Such methods are also required for current and future demands of plug-in electric vehicles and high-power electronic loads. Distributed control and optimal power network architectures will lead to viable solutions to the energy management issue with high level of reliability and security. This dissertation is aimed at developing and verifying new techniques for distributed control by deploying DC microgrids, involving distributed renewable generation and energy storage, through the operating AC power system. To achieve the findings of this dissertation, an energy system architecture was developed involving AC and DC networks, both with distributed generations and demands. The various components of the DC microgrid were designed and built including DC-DC converters, voltage source inverters (VSI) and AC-DC rectifiers featuring novel designs developed by the candidate. New control techniques were developed and implemented to maximize the operating range of the power conditioning units used for integrating renewable energy into the DC bus. The control and operation of the DC microgrids in the hybrid AC/DC system involve intelligent energy management. Real-time energy management algorithms were developed and experimentally verified. These algorithms are based on intelligent decision-making elements along with an optimization process. This was aimed at enhancing the overall performance of the power system and mitigating the effect of heavy non-linear loads with variable intensity and duration. The developed algorithms were also used for managing the charging/discharging process of plug-in electric vehicle emulators. The protection of the proposed hybrid AC/DC power system was studied. Fault analysis and protection scheme and coordination, in addition to ideas on how to retrofit currently available protection concepts and devices for AC systems in a DC network, were presented. A study was also conducted on the effect of changing the distribution architecture and distributing the storage assets on the various zones of the network on the system’s dynamic security and stability. A practical shipboard power system was studied as an example of a hybrid AC/DC power system involving pulsed loads. Generally, the proposed hybrid AC/DC power system, besides most of the ideas, controls and algorithms presented in this dissertation, were experimentally verified at the Smart Grid Testbed, Energy Systems Research Laboratory. All the developments in this dissertation were experimentally verified at the Smart Grid Testbed.
Resumo:
The performance of building envelopes and roofing systems significantly depends on accurate knowledge of wind loads and the response of envelope components under realistic wind conditions. Wind tunnel testing is a well-established practice to determine wind loads on structures. For small structures much larger model scales are needed than for large structures, to maintain modeling accuracy and minimize Reynolds number effects. In these circumstances the ability to obtain a large enough turbulence integral scale is usually compromised by the limited dimensions of the wind tunnel meaning that it is not possible to simulate the low frequency end of the turbulence spectrum. Such flows are called flows with Partial Turbulence Simulation.^ In this dissertation, the test procedure and scaling requirements for tests in partial turbulence simulation are discussed. A theoretical method is proposed for including the effects of low-frequency turbulences in the post-test analysis. In this theory the turbulence spectrum is divided into two distinct statistical processes, one at high frequencies which can be simulated in the wind tunnel, and one at low frequencies which can be treated in a quasi-steady manner. The joint probability of load resulting from the two processes is derived from which full-scale equivalent peak pressure coefficients can be obtained. The efficacy of the method is proved by comparing predicted data derived from tests on large-scale models of the Silsoe Cube and Texas-Tech University buildings in Wall of Wind facility at Florida International University with the available full-scale data.^ For multi-layer building envelopes such as rain-screen walls, roof pavers, and vented energy efficient walls not only peak wind loads but also their spatial gradients are important. Wind permeable roof claddings like roof pavers are not well dealt with in many existing building codes and standards. Large-scale experiments were carried out to investigate the wind loading on concrete pavers including wind blow-off tests and pressure measurements. Simplified guidelines were developed for design of loose-laid roof pavers against wind uplift. The guidelines are formatted so that use can be made of the existing information in codes and standards such as ASCE 7-10 on pressure coefficients on components and cladding.^