998 resultados para Soft X-ray
Resumo:
Through the use of time-integrated space-resolved keV spectroscopy, we investigate line plasmas showing gain in Ne-like nickel, copper, and zinc for irradiation using the prepulse technique. The experiments were conducted at 1.06 mu m with the prepulse to main pulse intensity contrast ranging from 10(-6) to 10(-2). The effect of the prepulses on the plasma conditions is inferred through spectroscopic line ratio diagnostics for the electron temperature, the Ne-like ground-state density, and the lateral size of the Ne-like region. It is observed that neither the value of the electronic temperature nor its spatially resolved profile along the linear focus axis varies significantly with the prepulse level, contrary to the lateral width and the density of the Ne-like region in the plasma, which are seen to increase. These results explain, at least in part, why prepulsed x-ray lasers show such high gain and brightness.
Resumo:
Evidence of high gain pumped by recombination has been observed in the 5g-4f transition at 11.1 nn in sodiumlike copper ions with use of a 20-J 2-ps Nd:glass laser system. The time- and space-integrated gain coefficient was 8.8 +/- 1.4 cm(-1), indicating a single-transit amplification of similar to 60 times. This experiment has shown that 2 ps is the optimum pulse duration to drive the sodiumlike copper recombination x-ray lasing at 11.1 nm. (C) 1996 Optical Society of America
Resumo:
Recombining plasmas produced by picosecond laser pulses are characterized by measuring ratio of intensities of resonance lines of H- and He-like ions in the plasmas. It is found that the rapidly recombining plasmas produced by picosecond laser pulses are suitable for high-gain operation.
Resumo:
Through the use of time-integrated space-resolved keV spectroscopy, we characterize line plasmas showing gain in Ne-like Zn with prepulsed irradiation to explain the enhanced performances of x-ray lasers using the prepulse technique. It is observed that the value of the electron temperature does not vary significantly with prepulse level, nor does its spatially resolved profile along the line. The lateral width and density of the Ne-like region in the plasma are seen to increase with the prepulse level. (C) 1995 Optical Society of America
NEAR-FIELD IMAGING OF THE C-VI HIGH-GAIN RECOMBINATION X-RAY LASER-DRIVEN BY A 20-J, 2 PS LASER-BEAM
Resumo:
The photo-pump strengths of both the ((3 (d) over bar(4))(0)(3d(6))(0))(0)-(((3 (d) over bar(3))(3/2)(3d(6))(0))(3/2)(5 (f) over bar)(5/2))(1) and the ((3 (d) over bar(4))(0)(3d(6))0)0-(((3 (d) over bar(4))(0)(3d(5))(5/2))(5/2)(5f)(7/2))(1) transitions in Ni-like Sm34+ have been measured to be 2.0 x 10(-4) and 2.4 x 10(-4) photons/mode respectively. The implications of the measurement are briefly discussed in a comparison of the merits of automatically line matched photo-pump scheme to those of the collisional excitation Ni-like Sm+34 scheme.
Resumo:
An imaging microscope, comprising a Schwarzchild condenser and zone plate optical arrangement, has been established on the Vulcan Nd-glass laser system at the Rutherford Appleton Laboratory (RAL). Images of simple test structures have been taken in X-ray transmission using doublet X-ray laser radiation at 23.2 nm and 23.6 nm from collisionally pumped Ne-like germanium. Image resolution of about 0.15 mum has been measured.
Resumo:
An imaging microscope, comprising a Schwarzchild condenser and a zone-plate optical arrangement, has been established on the Vulcan Nd:glass laser system at the Rutherford Appleton Laboratory. Magnified images of simple test structures have been taken in x-ray transmission in a single subnanosecond laser shot by using doublet x-ray laser radiation at 23.2 and 23.6 nm from collisionally pumped Ne-like germanium. Image resolutions of approximately 0.15 mum have been measured. The results are a proof of principle and demonstrate that images of potentially suboptical resolution and of specimen regions that are destroyed on passage of the x-ray beam can be taken successfully using the Vulcan x-ray laser.
Resumo:
The XUV lasing output from one germanium slab target has been efficiently coupled into, and further amplified in, a second plasma produced by irradiation of a similar target from the opposite direction. The operation of such a double target was shown to be strongly dependent on the distance by which the two target surfaces were displaced. The line brightness peaked for a surface displacement of approximately 200-mu-m and it was observed that the pointing direction of one output beam could be controlled by the surface separation in an asymmetric geometry. Gain length products of approximately 16 with estimated output powers close to the megawatt level were achieved on both the 23.2 and 23.6 nm J=2-1 transitions for an optimised target configuration. Maximum effective coupling efficiencies of the individual outputs from double targets, comprising 2.2 and 1.4 cm length components, approached 100% for beams propagating from the shorter to the longer target.
Resumo:
Characteristics of the 3p-3s amplified spontaneous emission from Ne-like Ge plasma columns, generated by ablation from massive targets, have been studied in detail. In particular, the gain coefficients of the J = 2-1 lines at 23.2 and 23.6 nm have been measured as a function of incident intensity for a 1.05-mu-m wavelength pump laser beam. For 100-mu-m wide stripe targets and a fixed energy pump laser the maximum gain length product is achieved at an irradiance of