905 resultados para Relaxation-times
Magnetic relaxation and quantum tunneling of vortices in polycristalline Hg0.8Tl0.2Ba2Ca2Cu3O8+sigma
Resumo:
We critically discuss relaxation experiments in magnetic systems that can be characterized in terms of an energy barrier distribution, showing that proper normalization of the relaxation data is needed whenever curves corresponding to different temperatures are to be compared. We show how these normalization factors can be obtained from experimental data by using the Tln (t/t0) scaling method without making any assumptions about the nature of the energy barrier distribution. The validity of the procedure is tested using a ferrofluid of Fe3O4 particles.
Resumo:
Unit Commitment Problem (UCP) in power system refers to the problem of determining the on/ off status of generating units that minimize the operating cost during a given time horizon. Since various system and generation constraints are to be satisfied while finding the optimum schedule, UCP turns to be a constrained optimization problem in power system scheduling. Numerical solutions developed are limited for small systems and heuristic methodologies find difficulty in handling stochastic cost functions associated with practical systems. This paper models Unit Commitment as a multi stage decision making task and an efficient Reinforcement Learning solution is formulated considering minimum up time /down time constraints. The correctness and efficiency of the developed solutions are verified for standard test systems
Resumo:
Spinnenseide gehört zu den stabilsten bekannten Polymerverbindungen. Spinnfäden können bis auf das Dreifache ihrer ursprünglichen Länge gedehnt werden, bevor sie reißen, und dabei mit rund 160 MJ/m³ mehr als dreimal soviel Energie absorbieren wie die stärkste synthetisch hergestellte Faser Kevlar (50 MJ/m³). Dabei weisen Spinnfäden mit 2 bis 5 Mikrometer nur ein Zehntel des Durchmessers eines menschlichen Haares auf. Das präzise, berührungslose Bearbeiten von Spinnenseide ist für verschiedene technische Anwendungen interessant, insbesondere wenn dabei ihre außergewöhnlichen Eigenschaften erhalten bleiben. Könnten die von Natur aus dünnen Seidenfäden gezielt in ihrem Durchmesser verringert werden, so wären sie unter anderem in der Mikroelektronik einzusetzen. Hier könnten sie als Trägermaterial für eine dünne, elektrisch leitfähige Schicht fungieren. Man erhielte Nanodrähte, die auch in mechanisch besonders belasteten Mikroelektronikbauteilen (MEMS) Verwendung finden könnten. In dieser Arbeit wird die Verwendung der laserinduzierten Ablation zur gezielten Bearbeitung von Haltefäden der Schwarzen Witwe (Latrodectus hesperus) beschrieben. Eingesetzt wurde ein VUV-Excimerlaser vom Typ LPF 205 (Lambda-Physik, Göttingen) mit einer Wellenlänge von 157 nm und einer Pulsdauer von 18 ns. Eine berührungslose Laserbearbeitung bei 157 nm erlaubt einen effizienten und präzisen Abtrag von Material durch Ablation aufgrund der geringen optischen Eindringtiefe von unter 100 nm oberhalb einer Schwellenfluenz (Energie/Fläche) von Φth=29 mJ/cm², ohne dabei das umgebende Material thermisch zu beeinträchtigen. Parallel zur Ablation setzt allerdings eine wellenförmige Oberflächenstrukturierung auf der Faseroberfläche ein, wodurch die mechanische Belastbarkeit der Faser entscheidend geschwächt wird. Die Ursache hierfür liegt im Abbau materialbedingter Spannungsfelder („stress release“) innerhalb einer durch das Laserlicht induzierten dünnen Schmelzschicht. Im Rahmen dieser Arbeit ist es nun gelungen, diese Strukturen durch einen anschließenden Glättungsprozeß zu entfernen. Dabei wird auf der bestrahlten Oberfläche mittels Laserlichts eine glatte Ablation erzielt. Mit feinerer Abstufung dieser Prozeßschritte konnte der Durchmesser des verwendeten Spinnenseidefadens zum Teil um 70 Prozent bis auf ca. 750 nm verringert werden. Durch Zugfestigkeitsexperimente wurde belegt, daß die mechanischen Eigenschaften der so bearbeiteten Spinnenseide weitgehend erhalten bleiben. Die im Rahmen dieser Arbeit angewandte Methode erlaubt somit eine präzise Laserablation von Spinnenseide und ähnlichen hochabsorbierenden Materialien, ohne deren Kernsubstanz in ihrer Beschaffenheit zu verändern.
Resumo:
Calculations of the level width \gamma( L_1) and the f_12 and f_13 Coster-Kronig yields for atomic zinc have been performed with Dirac-Fock wave functions. For \gamma(L_1), a large deviation between theory and evaluated data exists. We include the incomplete orthogonality of the electron orbitals as well as the interchannel interaction of the decaying states. Orbital relaxation reduces the total rates in all groups of the electron-emission spectrum by about 10-20 %. Different, however, is the effect of the continuum interaction. The L_1-L_23X Coster-Kronig part of the spectrum is definitely reduced in its intensity, whereas the MM and MN spectra are slightly enhanced. This results in a reduction of Coster-Kronig yields, where for medium and heavy elements considerable discrepancies have been found in comparison to relativistic theory. Briefly, we discuss the consequences of our calculations for heavier elements.
Resumo:
Relativistic Auger rates for the 2p spectra of Mg-like ions have been calculated in the atomic range 13 < Z < 36. We used the multiconfiguration Dirac-Fock method but beyond a simple frozen-orbital approach we include also relaxation for the bound electrons and the interchannel interaction between the continuum states. Both effects may alter the individual transition rates remarkably. This is analysed for a few selected states within the isoelectronic sequence. Weak transitions within the 2p spectra can be changed by an order of magnitude because of the continuum coupling. The influence of both effects for higher-Z ions is reduced but still remain visible.
Resumo:
Resumen tomado de la publicaci??n
Resumo:
Objetivo: Comparar la variabilidad en el tiempo de acción clínicamente efectivo (definido como el tiempo de aparición del T125% al estímulo por tren de cuatro) y la recuperación de la función neuromuscular luego de la administración de un bolo de 3 ED95 de cisatracurio o 2 ED95 de rocuronio en pacientes mayores de 65 años sometidos a cirugía. Materiales y Métodos: se incluyeron para este estudio pacientes mayores de 65 años de ambos sexos programados para cirugía electiva que requirieran de anestesia general, quienes durante la valoración preanestésica se incluyeran dentro de la clasificación de ASA 1, 2 o 3. Los pacientes requieren de haber firmado el consentimiento anestésicos, y no presentar alteración de la función renal, antecedente de disfunción hepática, enfermedad cardiovascular no compensada, enfermedad neurológica o neuromuscular, desequilibrio acido-base o estar bajo tratamiento con medicamentos que interactúen con los relajantes. Los pacientes fueron aleatorizados mediante un método de bloques permutados en dos grupos: GRUPO 1: Relajación muscular con cisatracurio 0.15 mg/kg IV y GRUPO 2: Relajación muscular con rocuronio 0.6 mg/kg IV. Se incluyeron 68 pacientes a los cuales se le cuantificaron mediante la utilización del dispositivo TOF-Watch SX los siguientes tiempos: T0, T125%, T4/T1=80% y T4/T1=90%. Con base en estas mediciones se obtuvieron las medidas de tendencia central y de dispersión, posteriormente se realizó un análisis de varianza y /o pruebas no paramétricas dependiendo de la distribución para determinar la variabilidad entre los tiempos obtenidos en cada grupo. Resultados: los grupos eran comparables desde el punto de vista de edad, sexo, número de pacientes (p>0.05). Se obtuvo como resultado final que el cisatracurio es menos variable que el rocuronio para cada una de las variables T0, T125%, T4/T1=80% y T4/T1=90% (p<0.01) en pacientes ancianos llevados a cirugía mayor de 90 minutos que requiera relajación neuromuscular. Conclusión: el cisatracurio es menos variable que el rocuronio cuando se utiliza en pacientes ancianos sometidos a cirugía mayor de 90 minutos que requiera relajación neuromuscular, pudiendo ser el cisatracurio un medicamento mas predecible en su tiempo de acción, con lo cual la probabilidad de asociarse a efectos por relajación neuromuscular residual es menor.