924 resultados para Ray E. Sanders


Relevância:

20.00% 20.00%

Publicador:

Resumo:

At the research reactor Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) a new Prompt Gamma-ray Activation Analysis (PGAA) facility was installed. The instrument was originally built and operating at the spallation source at the Paul Scherrer Institute in Switzerland. After a careful re-design in 2004–2006, the new PGAA instrument was ready for operation at FRM II. In this paper the main characteristics and the current operation conditions of the facility are described. The neutron flux at the sample position can reach up 6.07×1010 [cm−2 s−1], thus the optimisation of some parameters, e.g. the beam background, was necessary in order to achieve a satisfactory analytical sensitivity for routine measurements. Once the optimal conditions were reached, detection limits and sensitivities for some elements, like for example H, B, C, Si, or Pb, were calculated and compared with other PGAA facilities. A standard reference material was also measured in order to show the reliability of the analysis under different conditions at this instrument.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The malaria parasite Plasmodium depends on the tight control of cysteine-protease activity throughout its life cycle. Recently, the characterization of a new class of potent inhibitors of cysteine proteases (ICPs) secreted by Plasmodium has been reported. Here, the recombinant production, purification and crystallization of the inhibitory C-terminal domain of ICP from P. berghei in complex with the P. falciparum haemoglobinase falcipain-2 is described. The 1:1 complex was crystallized in space group P4(3), with unit-cell parameters a = b = 71.15, c = 120.09 A. A complete diffraction data set was collected to a resolution of 2.6 A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computational study of line-focus generation was done using a self-written ray-tracing code and compared to experimental data. Two line-focusing geometries were compared, i.e., either exploiting the sagittal astigmatism of a tilted spherical mirror or using the spherical aberration of an off-axis- illuminated spherical mirror. Line focusing by means of astigmatism or spherical aberration showed identical results as expected for the equivalence of the two frames of reference. The variation of the incidence angle on the target affects the line-focus length, which affects the amplification length such that as long as the irradiance is above the amplification threshold, it is advantageous to have a longer line focus. The amplification threshold is physically dependent on operating parameters and plasma-column conditions and in the present study addresses four possible cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radiation dose rates at flight altitudes may be hazardously increased during solar cosmic ray events. Within the scope of this paper we investigate the total accumulated radiation doses, i.e. the contribution of galactic and solar cosmic rays, during the two extreme solar cosmic ray events on 29 September 1989 and on 20 January 2005 along selected flight profiles. In addition, the paper discusses the consequences of possible solar cosmic ray flux approximations on the results of the radiation dose computations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: To quantify the late dose-related responses of the rat cervical spinal cord to X-ray irradiations by an array of microbeams or by a single millimeter beam. MATERIALS AND METHODS: Necks of anesthetized rats were irradiated transversely by an 11mm wide array of 52 parallel, 35μm wide, vertical X-ray microbeams, separated by 210μm intervals between centers. Comparison was made with rats irradiated with a 1.35mm wide single beam of similar X-rays. Rats were killed when paresis developed, or up to 383days post irradiation (dpi). RESULTS: Microbeam peak/valley doses of ≈357/12.7Gy to 715/25.4Gy to an 11mm long segment of the spinal cord, or single beam doses of ≈146-454Gy to a 1.35mm long segment caused foreleg paresis and histopathologically verified spinal cord damage; rats exposed to peak/valley doses up to 253/9Gy were paresis-free at 383dpi. CONCLUSIONS: Whereas microbeam radiation therapy [MRT] for malignant gliomas implanted in rat brains can be safe, palliative or curative, the high tolerance of normal rat spinal cords to similar microbeam exposures justifies testing MRT for autochthonous malignancies in the central nervous system of larger animals with a view to subsequent clinical applications.