971 resultados para ROTATION CURVES
Resumo:
Let f be a C(r)-diffeomorphism of the closed annulus A that preserves the orientation, the boundary components and the Lebesgue measure. Suppose that f has a lift (f) over tilde to the infinite strip (A) over tilde which has zero Lebesgue measure rotation number. If the rotation number of f restricted to both boundary components of (f) over tilde is positive, then for such a generic f (r >= 16), zero is an interior point of its rotation set. This is a partial solution to a conjecture of P. Boyland.
Resumo:
Several microorganisms were isolated from soil/sediment samples of Antarctic Peninsula. The enrichment technique using (RS)-.1-(phenyl) ethanol as a carbon source allowed us to isolate 232 psychrophile/psychrotroph microorganisms. We also evaluated the enzyme activity (oxidoreductases) for enantioselective oxidation reactions, by using derivatives of (RS)-.1-(phenyl) ethanol as substrates. Among the studied microorganisms, 15 psychrophile/psychrotroph strains contain oxidoreductases that catalyze the (S)-.enantiomer oxidation from racemic alcohols to their corresponding ketones. Among the identified microorganisms, Flavobacterium sp. and Arthrobacter sp. showed excellent enzymatic activity. These new bacteria strains were selected for optimization study, in which the (RS)-.1-(4-.methyl-.phenyl) ethanol oxidation was evaluated in several reaction conditions. From these studies, it was observed that Flavobacterium sp. has an excellent enzymatic activity at 10 degrees C and Arthrobacter sp. at 15 and 25 degrees C. We have also determined the growth curves of these bacteria, and both strains showed optimum growth at 25 degrees C, indicating that these bacteria are psychrotroph.
Resumo:
The electrocatalytic reduction of hydrogen peroxide on a glassy carbon (GC) electrode modified with a ruthenium oxide hexacyanoferrate (RuOHCF) was investigated using rotating disc electrode (RDE) voltammetry aiming to improve the performance of the sensor for hydrogen peroxide detection. The influence of parameters such as rotation speed, film thickness and hydrogen peroxide concentration indicated that the rate of the cross-chemical reaction between Ru(II) centres immobilized into the film and hydrogen peroxide controls the overall process. The kinetic regime could be classified as LSk mechanism, according to the diagnostic table proposed by Albery and Hillman, and the kinetic constant of the mediated process was found to be 706 mol(-1) cm(3) s(-1). In the LSk case the reaction layer is located at a finite layer close to the modifier layer/solution interface
Resumo:
The low-lying doublet and quartet electronic states of the species SeF correlating with the first dissociation channel are investigated theoretically at a high-level of electronic correlation treatment, namely, the complete active space self-consistent field/multireference single and double excitations configuration interaction (CASSCF/MRSDCI) using a quintuple-zeta quality basis set including a relativistic effective core potential for the selenium atom. Potential energy curves for (Lambda+S) states and the corresponding spectroscopic properties are derived that allows for an unambiguous assignment of the only spectrum known experimentally as due to a spin-forbidden X (2)Pi-a (4)Sigma(-) transition, and not a A (2)Pi-X (2)Pi transition as assumed so far. For the bound excited doublets, yet unknown experimentally, this study is the first theoretical characterization of their spectroscopic properties. Also the spin-orbit coupling constant function for the X (2)Pi state is derived as well as the spin-orbit coupling matrix element between the X (2)Pi and a (4)Sigma(-) states. Dipole moment functions and vibrationally averaged dipole moments show SeF to be a very polar species. An overview of the lowest-lying spin-orbit (Omega) states completes this description. (C) 2010 American Institute of Physics. [doi: 10.1063/1.3426315]
Resumo:
The extracellular hemoglobin of Glossoscolex paulistus (HbGp) is constituted of subunits containing heme groups, monomers and trimers, and nonheme structures, called linkers, and the whole protein has a minimum molecular mass near 3.1 x 10(6) Da. This and other proteins of the same family are useful model systems for developing blood substitutes due to their extracellular nature, large size, and resistance to oxidation. HbGp samples were studied by dynamic light scattering (DLS). In the pH range 6.0-8.0, HbGp is stable and has a monodisperse size distribution with a z-average hydrodynamic diameter (D-h) of 27 +/- 1 nm. A more alkaline pH induced an irreversible dissociation process, resulting in a smaller D-h of 10 +/- 1 nm. The decrease in D-h suggests a complete hemoglobin dissociation. Gel filtration chromatography was used to show unequivocally the oligomeric dissociation observed at alkaline pH. At pH 9.0, the dissociation kinetics is slow, taking a minimum of 24 h to be completed. Dissociation rate constants progressively increase at higher pH, becoming, at pH 10.5, not detectable by DILS. Protein temperature stability was also pH-dependent. Melting curves for HbGp showed oligomeric dissociation and protein denaturation as a function of pH. Dissociation temperatures were lower at higher pH. Kinetic studies were also performed using ultraviolet-visible absorption at the Soret band. Optical absorption monitors the hemoglobin autoxidation while DLS gives information regarding particle size changes in the process of protein dissociation. Absorption was analyzed at different pH values in the range 9.0-9.8 and at two temperatures, 25 degrees C and 38 degrees C. At 25 degrees C, for pH 9.0 and 9.3, the kinetics monitored by ultraviolet-visible absorption presents a monoexponential behavior, whereas for pH 9.6 and 9.8, a biexponential behavior was observed, consistent with heme heterogeneity at more alkaline pH. The kinetics at 38 degrees C is faster than that at 25 degrees C and is biexponential in the whole pH range. DLS dissociation rates are faster than the autoxidation dissociation rates at 25 degrees C. Autoxiclation and dissociation processes are intimately related, so that oligomeric protein dissociation promotes the increase of autoxidation rate and vice versa. The effect of dissociation is to change the kinetic character of the autoxidation of hemes from monoexponential to biexponential, whereas the reverse change is not as effective. This work shows that DLS can be used to follow, quantitatively and in real time, the kinetics of changes in the oligomerization of biologic complex supramolecular systems. Such information is relevant for the development of mimetic systems to be used as blood substitutes.
Resumo:
The Cerrado and Amazon regions of Brazil are probably the largest agricultural frontier of the world, and Could be a sink or source for C depending on the net effect of land use change and subsequent management on soil organic C pools. We evaluated the effects of agricultural management systems on soil organic C (SOC) stocks in the Brazilian states of Rondonia and Mato Grosso, and derived regional specific factors for soil C stock change associated with different management systems. We used 50 observations (data points) in this study, including 42 dealing with annual cropping practices and 8 dealing with perennial cropping, and analyzed the data in linear mixed-effect models. No tillage (NT) systems in Cerrado areas increased SOC Storage by 1.08 +/- 0.06 relative to SOC stocks under native conditions, while SOC storage increased by a modest factor of 1.01 +/- 0.17 in Cerradao and Amazon Forest conditions. Full tillage (FT) had negative effect on SOC storage relative to NT, decreasing SOC stocks by a factor of 0.94 +/- 0.04. but did not significantly reduce SOC stocks relative to native levels when adopted in the Cerrado region. Perennial cropping had a minimal impact on SOC stocks, estimated at a factor Value of 0.98 +/- 0.14, suggesting these systems maintain about 98% of the SOC stock found under native vegetation. The results Suggest that NT adoption may be increasing SOC with land use change from native vegetation to cropland management in the Cerrado region of Brazil. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
The aim of this paper was to study a method based on gas production technique to measure the biological effects of tannins on rumen fermentation. Six feeds were used as fermentation substrates in a semi-automated gas method: feed A - aroeira (Astronium urundeuva); feed B - jurema preta (Mimosa hostilis), feed C - sorghum grains (Sorghum bicolor); feed D - Tifton-85 (Cynodon sp.); and two others prepared mixing 450 g sorghum leaves, 450 g concentrate (maize and soybean meal) and 100 g either of acacia (Acacia mearnsii) tannin extract (feed E) or quebracho (Schinopsis lorentzii) tannin extract (feed F) per kg (w:w). Three assays were carried out to standardize the bioassay for tannins. The first assay compared two binding agents (polyethylene glycol - PEG - and polyvinyl polypirrolidone - PVPP) to attenuate the tannin effects. The complex formed by PEG and tannins showed to be more stable than PVPP and tannins. Then, in the second assay, PEG was used as binding agent, and this assay was done to evaluate levels of PEG (0, 500, 750, 1000 and 1250 mg/g DM) to minimize the tannin effect. All the tested levels of PEG produced a response to evaluate tannin effects but the best response was for dose of 1000 mg/g DM. Using this dose of PEG, the final assay was carried out to test three compounds (tannic acid, quebracho extract and acacia extract) to establish a curve of biological equivalent effect of tannins. For this, five levels of each compound were added to I g of a standard feed (Lucerne hay). The equivalent effect showed not to be directly related to the chemical analysis for tannins. It was shown that different sources of tannins had different activities or reactivities. The curves of biological equivalence can provide information about tannin reactivity and its use seems to be important as an additional factor for chemical analysis. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
The aim of this work is to demonstrate the feasibility of laser induced breakdown spectrometry (LIBS) for the determination of macro and micronutrients in multielement tablets. The experimental setup was designed by using a laser Q-switch (Nd:YAG, 10 Hz, lambda = 1064 nm) and the emission signals were collected by lenses into an optical fiber coupled to an echelle spectrometer equipped with a high-resolution intensified charge coupled device (ICCD). Tablets were cryogenically ground and thereafter pelletized before LIBS analysis. Calibration curves were made by employing samples and mixtures of commercial multielement tablets with binders at different ratios. Best results were achieved by using the following experimental conditions: 29 J cm(-2) laser fluence, 165 mm lens to sample distance (f = 200 mm), 2.0 mu s delay time, 5.0 mu s integration time and 5 accumulated laser pulses. In general, the results obtained by the proposed LIBS procedure were in agreement with those obtained by ICP OES from the corresponding acid digests and coefficients variation of LIBS measurements varied from 2 to 16%. The metrological figures of merit indicate that LIBS fits for the intended purposes, and can be recommended for the analysis of multielement tablets and similar matrices aiming the determination of Ca, Cu, Fe, Mg, Mn, P and Zn.
Resumo:
Cadmium is known to be a toxic agent that accumulates in the living organisms and present high toxicity potential over lifetime. Efforts towards the development of methods for microanalysis of environmental samples, including the determination of this element by graphite furnace atomic absorption spectrometry (GFAAS). inductively coupled plasma optical emission spectrometry (ICP OES), and inductively coupled plasma-mass spectrometry (ICP-MS) techniques, have been increasing. Laser induced breakdown spectroscopy (UBS) is an emerging technique dedicated to microanalysis and there is a lack of information dealing with the determination of cadmium. The aim of this work is to demonstrate the feasibility of LIBS for cadmium detection in soils. The experimental setup was designed using a laser Q-switched (Nd:YAG, 10 Hz, lambda = 1064 nm) and the emission signals were collimated by lenses into an optical fiber Coupled to a high-resolution intensified charge-coupled device (ICCD)-echelle spectrometer. Samples were cryogenically ground and thereafter pelletized before LIBS analysis. Best results were achieved by exploring a test portion (i.e. sampling spots) with larger surface area, which contributes to diminish the uncertainty due to element specific microheterogeneity. Calibration curves for cadmium determination were achieved using certified reference materials. The metrological figures of merit indicate that LIBS can be recommended for screening of cadmium contamination in soils. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
In this work, quaternary conformational studies of peanut agglutinin (PNA) have been carried out using small-angle X-ray scattering (SAXS). PNA was submitted to three different conditions: pH variation (2.5, 4.0, 7.4 and 9.0), guanidine hydrochloride presence (0.5-2 M) at each pH value, and temperature ranging from 25 to 60 degrees C. All experiments were performed in the absence and presence of T-antigen to evaluate its influence on the lectin stability. At room temperature and pH 4.0,7.4 and 9.0, the SAXS curves are consistent with the PNA scattering in its crystallographic native homotetrameric structure, with monomers in a jelly roll fold, associated by non-covalent bonds resulting in an open structure. At pH 2.5, the results indicate that PNA tends to dissociate into smaller sub-units, as dimers and monomers, followed by a self-assembling into larger aggregates. Furthermore, the conformational stability under thermal denaturation follows the pH sequence 7.4 > 9.0 > 4.0 > 2.5. Such results are consistent with the conformational behavior found upon GndHCl influence. The presence of T-antigen does not affect the protein quaternary structure in all studied systems within the SAXS resolution. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
AIM: We sought to evaluate the predictive validity of the Waterlow Scale in hospitalized patients. SUBJECTS AND SETTING: The study was conducted at a general private hospital with 220 beds and a mean time of hospitalization of 7.4 days and a mean occupation rate of approximately 80%. Adult patients with a Braden Scale score of 18 or less and a Waterlow Scale score of 16 or more were studied. The sample consisted of 98 patients with a mean age of 71.1 +/- 15.5 years. METHODS: Skin assessment and scoring by using the Waterlow and Braden scales were completed on alternate days. Patients were examined at least 3 times to be considered for analysis. The data were submitted to sensitivity and specificity analysis by using receiver operating characteristic (ROC) curves and positive (+LR) and negative (-LR) likelihood ratios. RESULTS: The cutoff scores were 17, 20, and 20 in the first, second, and third assessment, respectively. Sensitivity was 71.4%, 85.7%, and 85.7% and specificity was 67.0%, 40.7%, and 32.9%, respectively. Analysis of the area under the ROC curve revealed good accuracy (0.64, 95% confidence interval [CI]: 0.35-0.93) only for the cutoff score 17 in the first assessment. The results also showed probabilities of 14%, 10%, and 9% for the development of pressure ulcer when the test results were positive (+LR) and of 3% (-LR) when the test results were negative for the cutoff scores in the first, second, and third assessment, respectively. CONCLUSION: The Waterlow Scale achieved good predictive validity in predicting pressure ulcer in hospitalized patients when a cutoff score of 17 was used in the first assessment.
Resumo:
In this study, we evaluated alternative technical markers for the motion analysis of the pelvic segment. Thirteen subjects walked eight times while tri-dimensional kinematics were recorded for one stride of each trial. Five marker sets were evaluated, and we compared the tilt, obliquity, and rotation angles of the pelvis segment: (1) standard: markers at the anterior and posterior superior iliac spines (ASIS and PSIS); (2) markers at the PSIS and at the hip joint centers, HJCs (estimated by a functional method and described with clusters of markers at the thighs); (3) markers at the PSIS and HJCs (estimated by a predictive method and described with clusters of markers at the thighs); (4) markers at the PSIS and HJCs (estimated by a predictive method and described with skin-mounted markers at the thighs based on the Helen-Hayes marker set); (5) markers at the PSIS and at the iliac spines. Concerning the pelvic angles, evaluation of the alternative technical marker sets evinced that all marker sets demonstrated similar precision across trials (about 1 degrees) but different accuracies (ranging from 1 degrees to 3 degrees) in comparison to the standard marker set. We suggest that all the investigated marker sets are reliable alternatives to the standard pelvic marker set. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The objective of this study was to compare the three-dimensional lower extremity running kinematics of young adult runners and elderly runners. Seventeen elderly adults (age 67-73 years) and 17 young adults (age 26-36 years) ran at 3.1ms-1 on a treadmill while the movements of the lower extremity during the stance phase were recorded at 120Hz using three-dimensional video. The three-dimensional kinematics of the lower limb segments and of the ankle and knee joints were determined, and selected variables were calculated to describe the movement. Our results suggest that elderly runners have a different movement pattern of the lower extremity from that of young adults during the stance phase of running. Compared with the young adults, the elderly runners had a substantial decrease in stride length (1.97 vs. 2.23m; P=0.01), an increase in stride frequency (1.58 vs. 1.37Hz; P=0.002), less knee flexion/extension range of motion (26 vs. 33; P=0.002), less tibial internal/external rotation range of motion (9 vs. 12; P0.001), larger external rotation angle of the foot segment (toe-out angle) at the heel strike (-5.8 vs. -1.0; P=0.009), and greater asynchronies between the ankle and knee movements during running. These results may help to explain why elderly individuals could be more susceptible to running-related injuries.
Resumo:
This study aimed to analyse the effects of a single stretching exercise session on a number of gait parameters ill elderly participants in all attempt to determine whether these exercises can influence the risk of fall. Fifteen healthy women living in the community Volunteered to participate in the study. A kinematic gait analysis was performed immediately before and after a session of static stretching exercises applied oil hip flexor/extensor muscles. Results showed a significant influence of stretching exercises on a number of gait parameters, which have previously been proposed as fall predictors. Participants showed increased gait velocity, greater step length and reduced double Support time during stance after performing stretching exercises, suggesting improved stability and mobility. Changes around the pelvis (increased anterior-posterior tilt and rotation range of motion) resulting from the stretching exercises were suggested to influence the gait parameters (velocity, step length and double support time). Therefore, stretching exercises were shown to be a promising strategy to facilitate changes in gait parameters related to the risk of fall. Some other gait variables related to the risk of fall remained Unaltered (e.g., toe clearance). The stable pattern of segmental angular velocities was proposed to explain the stability of these unchanged gait variables. The results indicate that stretching exercises, performed oil a regular (daily) basis, result in gait adaptations which can be considered as indicative of reduced fall risk. Other Studies to determine whether regular stretching routines are an effective strategy to reduce the risk of fall are required. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Tin electrocoated steel strip, also referred to as Flandres foil, is largely used for manufacturing food containers. Tinplates must have good corrosion resistance, workability, weldability, as well as a bright appearance. The woodgrain defect, a not yet fully understood defect that occurs on tinplates and accounts for their high scrap rate, consists of alternate bands of bright/dull reflectivity and resembles longitudinally cut wood. Observations of the woodgrain defect by scanning electron microscopy showed that the molten tin spreads irregularly during both the melting and solidification stages. X-ray diffraction analyses showed that the metallic tin tended to crystallize in the (200) direction for coupons with and without the woodgrain defect. Nevertheless, the preferential orientation degree decreased for coupons with the woodgrain defect. The rocking curves, also known as omega-scan, showed that the tin grains were uniformly aligned parallel to the strip surface for coupons with no defects, whereas for tinplates with woodgrain, the tin grains were not uniformly oriented, probably due to the misalignment of the grains in relation to the surface. (C) 2011 Elsevier Inc. All rights reserved.