898 resultados para Primary health care. Non-transmissible chronic diseases. Assessment of health programs


Relevância:

100.00% 100.00%

Publicador:

Resumo:

CMS has established the medicaid Quality Improvement which serves to fulfill the objectives of they Medicaid Quality goal established through the Federal Government Performance and Results At. One of the objectives of the goal calls for the Centers foe Medicare and Medicaid Services to work in partnership with State Medicaid Directors to develop a Nation Medicaid Quality Framework that will articulate broad principles and a common vision of quality for the program.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: In the absence of a gold standard, the assessment of physical activity in children remains difficult. To record physical activity with a pedometer and to examine to what extent it is correlated with VO2max. METHODS: Survey on physical activity and fitness; 233 Swiss adolescents aged 11 to 15 carried a pedometer (Pedoboy) during seven consecutive days. VO2max was estimated through an endurance shuttle run test. RESULTS: The physical activity recorded by the pedometer did not vary from one day to the other (p > 0.05). The physical activity was higher among boys than among girls (p < 0.001) and higher among younger adolescents (6th versus 8th grade; p < 0.001). The correlation between physical activity and estimated VO2max was 0.30 (p < 0.01). CONCLUSIONS: The use of a pedometer to assess physical activity over one entire week is feasible among adolescents. The record provided by the pedometer gives an objective measure of the usual physical activity and, as such, is relatively well correlated with aerobic capacity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To determine the prevalence and clinical significance of hepatitis G virus (HGV) infection in a large cohort of patients with primary Sjögren¿s syndrome (SS). PATIENTS AND METHODS The study included 100 consecutive patients (92 female and eight male), with a mean age of 62 years (range 31¿80) that were prospectively visited in our unit. All patients fulfilled the European Community criteria for SS and underwent a complete history, physical examination, as well as biochemical and immunological evaluation for liver disease. Two hundred volunteer blood donors were also studied. The presence of HGV-RNA was investigated in the serum of all patients and donors. Aditionally, HBsAg and antibodies to hepatitis C virus were determined. RESULTS Four patients (4%) and six volunteer blood donors (3%) presented HGV-RNA sequences in serum. HGV infection was associated with biochemical signs of liver involvement in two (50%) patients. When compared with primary SS patients without HGV infection, no significant differences were found in terms of clinical or immunological features. HCV coinfection occurs in one (25%) of the four patients with HGV infection. CONCLUSION The prevalence of HGV infection in patients with primary SS is low in the geographical area of the study and HCV coinfection is very uncommon. HGV infection alone does not seen to be an important cause of chronic liver injury in the patients with primary SS in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess the accuracy of high-resolution (HR) magnetic resonance imaging (MRI) in diagnosing early-stage optic nerve (ON) invasion in a retinoblastoma cohort. METHODS: This IRB-approved, prospective multicenter study included 95 patients (55 boys, 40 girls; mean age, 29 months). 1.5-T MRI was performed using surface coils before enucleation, including spin-echo unenhanced and contrast-enhanced (CE) T1-weighted sequences (slice thickness, 2 mm; pixel size <0.3 × 0.3 mm(2)). Images were read by five neuroradiologists blinded to histopathologic findings. ROC curves were constructed with AUC assessment using a bootstrap method. RESULTS: Histopathology identified 41 eyes without ON invasion and 25 with prelaminar, 18 with intralaminar and 12 with postlaminar invasion. All but one were postoperatively classified as stage I by the International Retinoblastoma Staging System. The accuracy of CE-T1 sequences in identifying ON invasion was limited (AUC = 0.64; 95 % CI, 0.55 - 0.72) and not confirmed for postlaminar invasion diagnosis (AUC = 0.64; 95 % CI, 0.47 - 0.82); high specificities (range, 0.64 - 1) and negative predictive values (range, 0.81 - 0.97) were confirmed. CONCLUSION: HR-MRI with surface coils is recommended to appropriately select retinoblastoma patients eligible for primary enucleation without the risk of IRSS stage II but cannot substitute for pathology in differentiating the first degrees of ON invasion. KEY POINTS: • HR-MRI excludes advanced optic nerve invasion with high negative predictive value. • HR-MRI accurately selects patients eligible for primary enucleation. • Diagnosis of early stages of optic nerve invasion still relies on pathology. • Several physiological MR patterns may mimic optic nerve invasion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: A survey was undertaken among Swiss occupational hygienists and other professionals to identify the different exposure assessment methods used, the contextual parameters observed and the uses, difficulties and possible developments of exposure models for field application. METHODS: A questionnaire was mailed to 121 occupational hygienists, all members of the Swiss Occupational Hygiene Society. A shorter questionnaire was also sent to registered occupational physicians and selected safety specialists. Descriptive statistics and multivariate analyses were performed. RESULTS: The response rate for occupational hygienists was 60%. The so-called expert judgement appeared to be the most widely used method, but its efficiency and reliability were both judged with very low scores. Long-term sampling was perceived as the most efficient and reliable method. Various determinants of exposure, such as emission rate and work activity, were often considered important, even though they were not included in the exposure assessment processes. Near field local phenomena determinants were also judged important for operator exposure estimation. CONCLUSION: Exposure models should be improved to integrate factors which are more easily accessible to practitioners. Descriptors of emission and local phenomena should also be included.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the past years, cardiovascular magnetic resonance (CMR) has proven its efficacy in large clinical trials, and consequently, the assessment of function, viability, and ischaemia by CMR is now an integrated part of the diagnostic armamentarium in cardiology. By combining these CMR applications, coronary artery disease (CAD) can be detected in its early stages and this allows for interventions with the goal to reduce complications of CAD such as infarcts and subsequently chronic heart failure (CHF). As the CMR examinations are robust and reproducible and do not expose patients to radiation, they are ideally suited for repetitive studies without harm to the patients. Since CAD is a chronic disease, the option to monitor CAD regularly by CMR over many decades is highly valuable. Cardiovascular magnetic resonance also progressed recently in the setting of acute coronary syndromes. In this situation, CMR allows for important differential diagnoses. Cardiovascular magnetic resonance also delineates precisely the different tissue components in acute myocardial infarction such as necrosis, microvascular obstruction (MVO), haemorrhage, and oedema, i.e. area at risk. With these features, CMR might also become the preferred tool to investigate novel treatment strategies in clinical research. Finally, in CHF patients, the versatility of CMR to assess function, flow, perfusion, and viability and to characterize tissue is helpful to narrow the differential diagnosis and to monitor treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single amino acid substitution is the type of protein alteration most related to human diseases. Current studies seek primarily to distinguish neutral mutations from harmful ones. Very few methods offer an explanation of the final prediction result in terms of the probable structural or functional effect on the protein. In this study, we describe the use of three novel parameters to identify experimentally-verified critical residues of the TP53 protein (p53). The first two parameters make use of a surface clustering method to calculate the protein surface area of highly conserved regions or regions with high nonlocal atomic interaction energy (ANOLEA) score. These parameters help identify important functional regions on the surface of a protein. The last parameter involves the use of a new method for pseudobinding free-energy estimation to specifically probe the importance of residue side-chains to the stability of protein fold. A decision tree was designed to optimally combine these three parameters. The result was compared to the functional data stored in the International Agency for Research on Cancer (IARC) TP53 mutation database. The final prediction achieved a prediction accuracy of 70% and a Matthews correlation coefficient of 0.45. It also showed a high specificity of 91.8%. Mutations in the 85 correctly identified important residues represented 81.7% of the total mutations recorded in the database. In addition, the method was able to correctly assign a probable functional or structural role to the residues. Such information could be critical for the interpretation and prediction of the effect of missense mutations, as it not only provided the fundamental explanation of the observed effect, but also helped design the most appropriate laboratory experiment to verify the prediction results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Practicing physicians are faced with many medical decisions daily. These are mainly influenced by personal experience but should also consider patient preferences and the scientific evidence reflected by a constantly increasing number of medical publications and guidelines. With the objective of optimal medical treatment, the concept of evidence-based medicine is founded on these three aspects. It should be considered that there is a high risk of misinterpreting evidence, leading to medical errors and adverse effects without knowledge of the methodological background. OBJECTIVES: This article explains the concept of systematic error (bias) and its importance. Causes and effects as well as methods to minimize bias are discussed. This information should impart a deeper understanding, leading to a better assessment of studies and implementation of its recommendations in daily medical practice. CONCLUSION: Developed by the Cochrane Collaboration, the risk of bias (RoB) tool is an assessment instrument for the potential of bias in controlled trials. Good handling, short processing time, high transparency of judgements and a graphical presentation of findings that is easily comprehensible are among its strengths. Attached to this article the German translation of the RoB tool is published. This should facilitate the applicability for non-experts and moreover, support evidence-based medical decision-making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have compared a multiplexed bead-based assay (BBA) with an enzyme immunoassay (EIA) and immunofluorescence assay (IFA) for the assessment of the Epstein-Barr virus (EBV) serostatus. Three hundred and ninety-three sera, classified according to IFA results as seronegative (n=100), acute infection (n=100), past infection (n=100) and indeterminate (n=93), were tested by BBA and EIA. Overall, the three methods gave similar results with a relatively high (75.2%) concordance with the consensus interpretation of the serostatus. The most significant discordances were: (i) 58 samples had uninterpretable results for BBA, in majority due to the detection of non-antigen specific antibody binding by control beads. (ii) almost half the samples positive for anti-Epstein-Barr nuclear antigen (EBNA) IgG by BBA or EIA were negative by IFA. Among the latter, only a minority had a history of immunocompromise or treatment, or detectable anti-early antigen antibody. This discrepancy probably reflects a poor sensitivity of IFA for anti-EBNA IgG detection. EIA and BBA had a similar performance and had substantial practical advantages over IFA with respect to testing for EBV serostatus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Abdominal infections are frequent causes of sepsis and septic shock in the intensive care unit (ICU) and are associated with adverse outcomes. We analyzed the characteristics, treatments and outcome of ICU patients with abdominal infections using data extracted from a one-day point prevalence study, the Extended Prevalence of Infection in the ICU (EPIC) II. METHODS: EPIC II included 13,796 adult patients from 1,265 ICUs in 75 countries. Infection was defined using the International Sepsis Forum criteria. Microbiological analyses were performed locally. Participating ICUs provided patient follow-up until hospital discharge or for 60 days. RESULTS: Of the 7,087 infected patients, 1,392 (19.6%) had an abdominal infection on the study day (60% male, mean age 62 ± 16 years, SAPS II score 39 ± 16, SOFA score 7.6 ± 4.6). Microbiological cultures were positive in 931 (67%) patients, most commonly Gram-negative bacteria (48.0%). Antibiotics were administered to 1366 (98.1%) patients. Patients who had been in the ICU for ≤ 2 days prior to the study day had more Escherichia coli, methicillin-sensitive Staphylococcus aureus and anaerobic isolates, and fewer enterococci than patients who had been in the ICU longer. ICU and hospital mortality rates were 29.4% and 36.3%, respectively. ICU mortality was higher in patients with abdominal infections than in those with other infections (29.4% vs. 24.4%, p < 0.001). In multivariable analysis, hematological malignancy, mechanical ventilation, cirrhosis, need for renal replacement therapy and SAPS II score were independently associated with increased mortality. CONCLUSIONS: The characteristics, microbiology and antibiotic treatment of abdominal infections in critically ill patients are diverse. Mortality in patients with isolated abdominal infections was higher than in those who had other infections.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Growth is a central process in paediatrics. Weight and height evaluation are therefore routine exams for every child but in some situation, particularly inflammatory bowel disease (IBD), a wider evaluation of nutritional status needs to be performed. The assessment of body composition is essential in order to maintain acceptable growth using the following techniques: Dual-energy X-ray absorptiometry (DEXA), bio-impedance-analysis (BIA) and anthropometric measurements (skinfold thickness skin), the latter being most easily available and most cost effective. Objectives: To assess the accuracy of skinfold equations in estimating percentage body fat (%BF) in children with inflammatory bowel disease (IBD), compared with assessment of body fat dual energy X-ray absorptiometry (DEXA). Methods: Twenty-one patients (11 females, 10 males; mean age: 14.3 years, range 12 - 16 years) with IBD (Crohn's disease n = 15, ulcerative colitis n = 6)). Estimated%BF was computed using 6 established equations based on the triceps, biceps, subscapular and suprailiac skinfolds (Deurenberg, Weststrate, Slaughter, Durnin & Rahaman, Johnston, Brook) and compared to DEXA. Concordance analysis was performed using Lin's concordance correlation and the Bland-Altman limits of agreement method. Results: Durnin & Rahaman's equation shows a higher Lin's concordance coefficient with a small difference amongst raw values for skinfolds and DEXA compared to the other equations. Correlation coefficient between mean and difference is close to zero with a non-significant Bradley-Blackwood test. Conclusion: Body composition in paediatric IBD patients using the Durnin & Rahaman skinfold-equation adequately reflects values obtained by DEXA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Assessing the total energy expenditure (TEE) and the levels of physical activity in free-living conditions with non-invasive techniques remains a challenge. The purpose of the present study was to investigate the accuracy of a new uniaxial accelerometer for assessing TEE and physical-activity-related energy expenditure (PAEE) over a 24 h period in a respiratory chamber, and to establish activity levels based on the accelerometry ranges corresponding to the operationally defined metabolic equivalent (MET) categories. In study 1, measurement of the 24 h energy expenditure of seventy-nine Japanese subjects (40 (SD 12) years old) was performed in a large respiratory chamber. During the measurements, the subjects wore a uniaxial accelerometer (Lifecorder; Suzuken Co. Ltd, Nagoya, Japan) on their belt. Two moderate walking exercises of 30 min each were performed on a horizontal treadmill. In study 2, ten male subjects walked at six different speeds and ran at three different speeds on a treadmill for 4 min, with the same accelerometer. O2 consumption was measured during the last minute of each stage and was expressed in MET. The measured TEE was 8447 (SD 1337) kJ/d. The accelerometer significantly underestimated TEE and PAEE (91.9 (SD 5.4) and 92.7 (SD 17.8) % chamber value respectively); however, there was a significant correlation between the two values (r 0.928 and 0.564 respectively; P<0.001). There was a strong correlation between the activity levels and the measured MET while walking (r(2) 0.93; P<0.001). Although TEE and PAEE were systematically underestimated during the 24 h period, the accelerometer assessed energy expenditure well during both the exercise period and the non-structured activities. Individual calibration factors may help to improve the accuracy of TEE estimation, but the average calibration factor for the group is probably sufficient for epidemiological research. This method is also important for assessing the diurnal profile of physical activity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO(TM) is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. OBJECTIVE: To evaluate the potential of VEO(TM) on diagnostic image quality and dose reduction in pediatric chest CT examinations. MATERIALS AND METHODS: Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDIvol 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. RESULTS: At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. CONCLUSIONS: At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to use the plantar pressure insole for estimating the three-dimensional ground reaction force (GRF) as well as the frictional torque (T(F)) during walking. Eleven subjects, six healthy and five patients with ankle disease participated in the study while wearing pressure insoles during several walking trials on a force-plate. The plantar pressure distribution was analyzed and 10 principal components of 24 regional pressure values with the stance time percentage (STP) were considered for GRF and T(F) estimation. Both linear and non-linear approximators were used for estimating the GRF and T(F) based on two learning strategies using intra-subject and inter-subjects data. The RMS error and the correlation coefficient between the approximators and the actual patterns obtained from force-plate were calculated. Our results showed better performance for non-linear approximation especially when the STP was considered as input. The least errors were observed for vertical force (4%) and anterior-posterior force (7.3%), while the medial-lateral force (11.3%) and frictional torque (14.7%) had higher errors. The result obtained for the patients showed higher error; nevertheless, when the data of the same patient were used for learning, the results were improved and in general slight differences with healthy subjects were observed. In conclusion, this study showed that ambulatory pressure insole with data normalization, an optimal choice of inputs and a well-trained nonlinear mapping function can estimate efficiently the three-dimensional ground reaction force and frictional torque in consecutive gait cycle without requiring a force-plate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The addition of starter culture and high pressure processing after ripening improved the microbial quality of low-acid fermented sausages (fuet and chorizo). The use of Lactobacillus sakei CTC6626 and Staphylococcus xylosus CTC6013 as starter culture significantly reduced Enterobacteriaceae and Enterococcus levels in the finished sausages. Moreover, the addition of starter culture produced sausages of similar quality to traditional low-acid fermented sausages. Slightly lower pH values and higher cohesiveness were obtained for both fuet and chorizo with starter culture. Sensory analysis showed no differences between lots of chorizo whereas starter fuet was more acid and gummy. High pressure induced an additional reduction of Enterobacteriaceae in non-starter sausages. An increase of textural properties was observed after pressurization. No other differences were observed between non-treated and pressurized sausages.