966 resultados para Precision


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Personality differences based on fine motor precision performance were studied in early stage Parkinson's patients and an age-matched control group under two different test conditions: proprioceptive + visual information and proprioceptive information alone. A comparative data analysis for deviations of three measured movement types (transversal, frontal and sagittal) was done for both hands (dominant and non-dominant) with relation to personality dimensions. There were found significant differences between the two groups in decision making dimension and emotionality. After splitting the data for gender subgroups, some significant differences were found for men but not for women. The differences in fine motor task performance varied, being better in some directions for the Parkinson"s patients and worse in others. The findings may suggest that medication has both positive and negative effects on motor performance and provoke personality changes, being more pronounced in men.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study describes some of the applications of ultrasound in bone surgery, based on the presentation of two clinical cases. The Piezosurgery® ultrasound device was used (Tecnología Mectron Medical, Carasco, Italy). In one case the instrument was used to harvest a chin bone graft for placement in a bone defect at level 1.2, while in the other case a bony window osteotomy was made in the external wall of the maxillary sinus, in the context of a sinus membrane lift procedure. The Piezosurgery® device produces specific ultrasound frequency modulation (25-29 kHz), and has been designed to secure increased precision in application to bone surgery. This instrument produces selective sectioning of the mineralized bone structures, and causes less intra- and postoperative bleeding. One of the advantages of the Piezosurgery® device is that it can be used for maxillary sinus lift procedures in dental implant placement. In this context it considerably lessens the risk of sinus mucosa laceration by preparing the bony window in the external wall of the upper maxilla, and can be used to complete the lifting maneuver. The use of ultrasound in application to hard tissues can be regarded as a slow technique compared with the conventional rotary instruments, since it requires special surgical skill and involves a certain learning curve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Hepatitis E virus (HEV) emerged as an autochthonous food-borne disease in developed countries, transmitted mainly through pork meat. Cases of transmission through blood transfusion have been reported. Recent studies revealed sero-prevalence rates of 13.5%, 16.6% and 20.6% among blood donors in England, France and Denmark, respectively. The aim of this study was to determine the sero-prevalence of HEV among Swiss blood donors. Method: We screened 550 consecutive blood donations from the Service Régional Vaudois de Transfusion Sanguine of Epalinges, for the presence of anti-HEV IgG (MP Diagnostics HEV ELISA). The sample size was based on the Lorentz formula considering an expected prevalence of 3% with a precision of 1.5%. For each donor, we studied the following variables: age, sex and alanine aminotransferase (ALT) value. Results: All blood donors were Caucasian, and included 332 men (60.4%) and 218 women (39.6%). The median age was 55 years (IQR 46-63 years). Overall, anti-HEV IgG were found in 27 of 550 samples (4.9%). The sero-prevalence was 5.4% (18/314) in men and 4.1% (9/209) in women. The presence of anti-HEV IgG was not correlated to age, gender or ALT values. Conclusion: Compared to other European countries, the HEV sero-prevalence among blood donors in Switzerland is surprisingly low. Possible explanations include the strict regulation of animals and meat import. However, to confirm this hypothesis, further studies assessing the prevalence of HEV in Swiss swine will be necessary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The potential of digital holography for complex manipulation of micron-sized particles with optical tweezers has been clearly demonstrated. By contrast, its use in quantitative experiments has been rather limited, partly due to fluctuations introduced by the spatial light modulator (SLM) that displays the kinoforms. This is an important issue when high temporal or spatial stability is a concern. We have investigated the performance of both an analog-addressed and a digitally-addressed SLM, measuring the phase fluctuations of the modulated beam and evaluating the resulting positional stability of a holographic trap. We show that, despite imparting a more unstable modulation to the wavefront, our digitally-addressed SLM generates optical traps in the sample plane stable enough for most applications. We further show that traps produced by the analog-addressed SLM exhibit a superior pointing stability, better than 1 nm, which is comparable to that of non-holographic tweezers. These results suggest a means to implement precision force measurement experiments with holographic optical tweezers (HOTs).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Se presenta un breve estado de la cuestión sobre la realidad arqueológica de los principales núcleos urbanos del este de la provincia Tarraconensis y a finales del Regnum Gothorum. Existe un nivel de conocimiento desigual para estas ciudades, fruto del contexto actual de la investigación, y también de una evolución histórica diferenciada, como consecuencia de unas características geopolíticas propias que, posiblemente, indujeron a una modificación de las jerarquías entre las ciudades. Planteamos la ciudad visigoda como el centro de gestión civil y religioso de una unidad territorial donde la arqueología identifica los vestigios de la arquitectura del poder, pero todavía no consigue definir con precisión los procesos domésticos inherentes a toda comunidad urbana. Conocemos globalmente los diferentes procesos de la desestructuración urbana de la Antigüedad tardía pero no los parámetros de la ocupación agrourbana de los recintos amurallados. Para este período histórico se supone que la redimensión demográfica del hecho urbano más una reducción de las relaciones económicas entre la ciudad y el territorio son factores determinantes de las nuevas ciudades visigodas, pero se reconoce una incertidumbre fruto de la dificultad arqueológica de estudiar las nuevas pautas constructivas y una cultura material más restringida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: PCR has the potential to detect and precisely quantify specific DNA sequences, but it is not yet often used as a fully quantitative method. A number of data collection and processing strategies have been described for the implementation of quantitative PCR. However, they can be experimentally cumbersome, their relative performances have not been evaluated systematically, and they often remain poorly validated statistically and/or experimentally. In this study, we evaluated the performance of known methods, and compared them with newly developed data processing strategies in terms of resolution, precision and robustness. RESULTS: Our results indicate that simple methods that do not rely on the estimation of the efficiency of the PCR amplification may provide reproducible and sensitive data, but that they do not quantify DNA with precision. Other evaluated methods based on sigmoidal or exponential curve fitting were generally of both poor resolution and precision. A statistical analysis of the parameters that influence efficiency indicated that it depends mostly on the selected amplicon and to a lesser extent on the particular biological sample analyzed. Thus, we devised various strategies based on individual or averaged efficiency values, which were used to assess the regulated expression of several genes in response to a growth factor. CONCLUSION: Overall, qPCR data analysis methods differ significantly in their performance, and this analysis identifies methods that provide DNA quantification estimates of high precision, robustness and reliability. These methods allow reliable estimations of relative expression ratio of two-fold or higher, and our analysis provides an estimation of the number of biological samples that have to be analyzed to achieve a given precision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Changes in the informal caregiver life styles, relations and alterations of mental health. Justification.The increase of the population aged 65 years and older in developed countries is generating a proportional increasing of the dependency caused by chronic pathologies. The care of these persons is being carried out by relatives, informal carers, leading to some alterations in diverse areas, among them mental alterations, as a consequence of taking care. Objectives. To develop a profile of the informal carers and to correlate the caregiver burden with the carers disorders. To detect risk factors to allow carrying out premature nursing interventions to diminish the disorders in the informal carers. Design. An observational and cross-sectional study is made in primary care health services area of the city of Girona. Methodology. Random sample of carer of dependent people at their home , assigned to the program of domiciliary attention (ATDOM) of the educational basic areas of health (ABS). A sample size of 269 persons, with a level of precision of 9% was needed. Questionnaire ICUB 97, the test of Barthel, the Philadelphia Geriatric Center scale, and a questionnaire are used as instruments that includes demographic and social variables, and mental and physical carers disorders.Results. A total of 80 participants were interviewed. The most common problems as consequence of taking care were the backache, to feel more tired, to feel impotent and to have less free time. Correlation between the level of dependence of the patient with the number of problems perceived by the caretaker does not exist. Since they are informal carers they eat frequently outside the habitual schedule, took place an increase or loss of weight, experienced more disorders in sexual life and an increasing lack of interest in surroundings. A 33% of the informal carers are being treated for problems related to the mental health.Conclusion. The fact of being informal carer carries important consequences in their health, the lifestyles and the social relations. These can be attenuated if the nursing interventions are able to consider to the well-taken care of subject, and its surroundings in an holistic way. The professionals of infirmary of mental health must contribute to their knowledge and abilities contributing to make an assessment, a diagnosis and an intervention paying special attention to psycho-social aspects mentioned

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Genotypic frequencies at codominant marker loci in population samples convey information on mating systems. A classical way to extract this information is to measure heterozygote deficiencies (FIS) and obtain the selfing rate s from FIS = s/(2 - s), assuming inbreeding equilibrium. A major drawback is that heterozygote deficiencies are often present without selfing, owing largely to technical artefacts such as null alleles or partial dominance. We show here that, in the absence of gametic disequilibrium, the multilocus structure can be used to derive estimates of s independent of FIS and free of technical biases. Their statistical power and precision are comparable to those of FIS, although they are sensitive to certain types of gametic disequilibria, a bias shared with progeny-array methods but not FIS. We analyse four real data sets spanning a range of mating systems. In two examples, we obtain s = 0 despite positive FIS, strongly suggesting that the latter are artefactual. In the remaining examples, all estimates are consistent. All the computations have been implemented in a open-access and user-friendly software called rmes (robust multilocus estimate of selfing) available at http://ftp.cefe.cnrs.fr, and can be used on any multilocus data. Being able to extract the reliable information from imperfect data, our method opens the way to make use of the ever-growing number of published population genetic studies, in addition to the more demanding progeny-array approaches, to investigate selfing rates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Head space gas chromatography with flame-ionization detection (HS-GC-FID), ancl purge and trap gas chromatography-mass spectrometry (P&T-GC-MS) have been used to determine methyl-tert-butyl ether (MTBE) and benzene, toluene, and the ylenes (BTEX) in groundwater. In the work discussed in this paper measures of quality, e.g. recovery (94-111%), precision (4.6 - 12.2%), limits of detection (0.3 - 5.7 I~g L 1 for HS and 0.001 I~g L 1 for PT), and robust-ness, for both methods were compared. In addition, for purposes of comparison, groundwater samples from areas suffering from odor problems because of fuel spillage and tank leakage were analyzed by use of both techniques. For high concentration levels there was good correlation between results from both methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Changes in the informal caregiver life styles, relations and alterations of mental health. Justification.The increase of the population aged 65 years and older in developed countries is generating a proportional increasing of the dependency caused by chronic pathologies. The care of these persons is being carried out by relatives, informal carers, leading to some alterations in diverse areas, among them mental alterations, as a consequence of taking care. Objectives. To develop a profile of the informal carers and to correlate the caregiver burden with the carers disorders. To detect risk factors to allow carrying out premature nursing interventions to diminish the disorders in the informal carers. Design. An observational and cross-sectional study is made in primary care health services area of the city of Girona. Methodology. Random sample of carer of dependent people at their home , assigned to the program of domiciliary attention (ATDOM) of the educational basic areas of health (ABS). A sample size of 269 persons, with a level of precision of 9% was needed. Questionnaire ICUB 97, the test of Barthel, the Philadelphia Geriatric Center scale, and a questionnaire are used as instruments that includes demographic and social variables, and mental and physical carers disorders.Results. A total of 80 participants were interviewed. The most common problems as consequence of taking care were the backache, to feel more tired, to feel impotent and to have less free time. Correlation between the level of dependence of the patient with the number of problems perceived by the caretaker does not exist. Since they are informal carers they eat frequently outside the habitual schedule, took place an increase or loss of weight, experienced more disorders in sexual life and an increasing lack of interest in surroundings. A 33% of the informal carers are being treated for problems related to the mental health.Conclusion. The fact of being informal carer carries important consequences in their health, the lifestyles and the social relations. These can be attenuated if the nursing interventions are able to consider to the well-taken care of subject, and its surroundings in an holistic way. The professionals of infirmary of mental health must contribute to their knowledge and abilities contributing to make an assessment, a diagnosis and an intervention paying special attention to psycho-social aspects mentioned

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To test the validity of a simple, rapid, field-adapted, portable hand-held impedancemeter (HHI) for the estimation of lean body mass (LBM) and percentage body fat (%BF) in African women, and to develop specific predictive equations. DESIGN: Cross-sectional observational study. SETTINGS: Dakar, the capital city of Senegal, West Africa. SUBJECTS: A total sample of 146 women volunteered. Their mean age was of 31.0 y (s.d. 9.1), weight 60.9 kg (s.d. 13.1) and BMI 22.6 kg/m(2) (s.d. 4.5). METHODS: Body composition values estimated by HHI were compared to those measured by whole body densitometry performed by air displacement plethysmography (ADP). The specific density of LBM in black subjects was taken into account for the calculation of %BF from body density. RESULTS: : Estimations from HHI showed a large bias (mean difference) of 5.6 kg LBM (P<10(-4)) and -8.8 %BF (P<10(-4)) and errors (s.d. of the bias) of 2.6 kg LBM and 3.7 %BF. In order to correct for the bias, specific predictive equations were developed. With the HHI result as a single predictor, error values were of 1.9 kg LBM and 3.7 %BF in the prediction group (n=100), and of 2.2 kg LBM and 3.6 %BF in the cross-validation group (n=46). Addition of anthropometrical predictors was not necessary. CONCLUSIONS: The HHI analyser significantly overestimated LBM and underestimated %BF in African women. After correction for the bias, the body compartments could easily be estimated in African women by using the HHI result in an appropriate prediction equation with a good precision. It remains to be seen whether a combination of arm and leg impedancemetry in order to take into account lower limbs would further improve the prediction of body composition in Africans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Focal therapy may reduce the toxicity of current radical treatments while maintaining the oncological benefit. Irreversible electroporation (IRE) has been proposed to be tissue selective and so might have favourable characteristics compared to the currently used prostate ablative technologies. The aim of this trial is to determine the adverse events, genito-urinary side effects and early histological outcomes of focal IRE in men with localised prostate cancer. METHODS: This is a single centre prospective development (stage 2a) study following the IDEAL recommendations for evaluating new surgical procedures. Twenty men who have MRI-visible disease localised in the anterior part of the prostate will be recruited. The sample size permits a precision estimate around key functional outcomes. Inclusion criteria include PSA ≤ 15 ng/ml, Gleason score ≤ 4 + 3, stage T2N0M0 and absence of clinically significant disease outside the treatment area. Treatment delivery will be changed in an adaptive iterative manner so as to allow optimisation of the IRE protocol. After focal IRE, men will be followed during 12 months using validated patient reported outcome measures (IPSS, IIEF-15, UCLA-EPIC, EQ-5D, FACT-P, MAX-PC). Early disease control will be evaluated by mpMRI and targeted transperineal biopsy of the treated area at 6 months. DISCUSSION: The NEAT trial will assess the early functional and disease control outcome of focal IRE using an adaptive design. Our protocol can provide guidance for designing an adaptive trial to assess new surgical technologies in the challenging landscape of health technology assessment in prostate cancer treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. PARTICIPANTS AND METHODS: The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. RESULTS: In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. CONCLUSIONS: The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A transportable, whole body indirect calorimeter, designed for use in the tropics, is described. The calorimeter was built to study energy expenditure of people having chronically or acutely low levels of food intake, and it will help to determine energy adaptations made by individuals with restricted food intake. The calorimeter comprises two units: a 27 m3 ventilated chamber connected to an office housing control and monitoring equipment. The system also allows the experimenter to assess the rate of energy expenditure by means of a ventilated hood or a baby respiration chamber. The incoming air flow rate is variable and is typically set at approximately 30 l/min. Carbon dioxide production (VCO2) and oxygen consumption (VO2) are continuously monitored by means of differential gas analysers via a computerized data acquisition unit. Gas production/consumption rates are measured with a delay of 80 s, the complete response to step changes in VCO2 or VO2 consumption being calculated over 15 min using the rate of change terms in the gas exchange equations. The total electrical power required for the whole system is 12 kW. The calorimeter has been functioning for nearly 4 years in a rural village of The Gambia during which ambient temperatures have ranged from 16 to 44 degrees C and dewpoints from -8 to 24 degrees C. The performance and accuracy of the calorimeter were tested using 20 per cent CO2 in N2 infusion and butane burning. Agreement between the theoretical and the measured values was found to be 99 per cent for VO2 and 100 per cent for VCO2 with a precision for both gases of +/- 10 ml/min over a 1-h period.