869 resultados para Power system stability


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The transmission expansion planning problem in modern power systems is a large-scale, mixed-integer, nonlinear and non-convex problem. this paper presents a new mathematical model and a constructive heuristic algorithm (CHA) for solving transmission expansion planning problem under new environment of electricity restructuring. CHA finds an acceptable solution in an iterative process, where in each step a circuit is chosen using a sensitivity index and added to the system. The proposed model consider multiple generation scenarios therefore the methodology finds high quality solution in which it allows the power system operate adequacy in an environment with multiple generators scenarios. Case studies and simulation results using test systems show possibility of using Constructive heuristic algorithm in an open access system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Faced with an imminent restructuring of the electric power system, over the past few years many countries have invested in a new paradigm known as Smart Grid. This paradigm targets optimization and automation of electric power network, using advanced information and communication technologies. Among the main communication protocols for Smart Grids we have the DNP3 protocol, which provides secure data transmission with moderate rates. The IEEE 802.15.4 is another communication protocol also widely used in Smart Grid, especially in the so-called Home Area Network (HAN). Thus, many applications of Smart Grid depends on the interaction of these two protocols. This paper proposes modeling, in the traditional network simulator NS-2, the integration of DNP3 protocol and the IEEE 802.15.4 wireless standard for low cost simulations of Smart Grid applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With the imposition of the suspension of production and subsequent banning of incandescent light bulbs will be necessary to replace it by other more energy-efficient. Although the main alternative is the compact fluorescent lamp, the environmental impact caused by it due to incorrect disposal and the amount of harmonics included in the network resulting in losses related to the quality of electric power system makes them sought new alternatives for lighting systems that are efficient and have low environmental impact. In this context, the LED (Lighting Emitting Diode), based on solid-state components, is presented as an option for new projects and replacement of existing lighting. In this work we studied aspects of energy, environmental and economic impacts of a possible replacement of conventional lighting systems for new technology. From laboratory tests and surveys of the costs of different types of lamps used for residential lighting, we performed a comparative analysis considering energy and economic aspects which showed that the LED technology, but has a high initial investment, it is best when power quality and environmental preservation are relevant factors in decision making for the choice of technology to be used in the lighting system

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use and inadequate exploitation of natural resources is restricting the occurrence of aroeira (Myracrodruon urundeuva F.F. & M.F. Allemão), which now is on the FAO list of endangered species. This exploitation causes a decrease in the genetic base of M. urundeuva populations, which makes it difficult to find genotypes with stability and adaptability to different growing conditions. This study aimed at estimating the genetic variation and productivity, stability and adaptability of progenies of a M. urundeuva natural population, from the Ecological Station of Paulo de Faria-SP, under different planting systems. DBH (diameter at breast height) was evaluated in four progeny tests of M. urundeuva: i) planted with Anandenanthera falcata and Guazuma ulmifolia (TP-AMA); ii) single (TP-ASO); iii) planted with annual crops (TP-SAF) and iv) planted with Corymbia citriodora (TP-EUCA), installed in Selvíria-MS. The experimental design consisted of complete randomized blocks with three replications and a variable number of plants per plot in each of the four planting systems. From the joint analysis of the planting systems studied, it was found that: i) there were variations among planting systems particularly in TP-SAF; ii) only in TP-EUCA it was possible to detect variations among the progenies; iii) the effects of the genotype x environment interaction were not significant. Thereby, the harmonic mean of genotypic values (MHVG), the relative performance of genotypic values from the mean of each site (PRVG) and the harmonic mean of the relative performance of genotypic values (MHPRVG) for DBH showed, respectively: progenies with greater stability, adaptability, and stability and simultaneous adaptability within different planting systems. The use of these selection criteria provided a more refined selection of the best progenies of M. urundeuva under the different planting systems studied.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a mixed-integer convex-optimization-based approach for optimum investment reactive power sources in transmission systems. Unlike some convex-optimization techniques for the reactive power planning solution, in the proposed approach the taps settings of under-load tap-changing of transformers are modeled as a mixed-integer linear set equations. Are also considered the continuous and discrete variables for the existing and new capacitive and reactive power sources. The problem is solved for three significant demand scenarios (low demand, average demand and peak demand). Numerical results are presented for the CIGRE-32 electric power system.