884 resultados para Peripheral fatigue
Resumo:
The authors report two female patients with chronic sensitive and motor findings in lower limbs caused by compression of distal branches of sciatic nerve by lipoma. Similar eases were not described on literature. Nerve conduction studies allowed to localize the exact site of compression. At surgery, lipomas compressing the deep peroneal nerve (case 1) and the posterior tibial nerve (case 2) were observed. Histologic studies of tumors confirmed the diagnoses.
Resumo:
Objective - To investigate the effects of inhalation and total IV anesthesia on pituitary-adrenal activity in ponies. Animals - 9 healthy ponies: 5 geldings and 4 mares. Procedure - Catheters were placed in the cavernous sinus below the pituitary gland and in the subarachnoid space via the lumbosacral space. After 72 hours, administration of acepromazine was followed by induction of anesthesia with thiopentone and maintenance with halothane (halothane protocol), or for the IV protocol, anesthesia induction with detomidine and ketamine was followed by maintenance with IV infusion of a detomidine-ketamine-guaifenesin combination. Arterial blood pressure and gas tensions were measured throughout anesthesia. Peptide and catecholamine concentrations were measured in pituitary effluent, peripheral plasma, and CSF. Peripheral plasma cortisol, glucose, and lactate concentrations also were measured. Results - Intravenous anesthesia caused less cardiorespiratory depression than did halothane. ACTH, metenkephalin, arginine vasopressin, and norepinephrine pituitary effluent and peripheral plasma concentrations were higher during halothane anesthesia, with little change during intravenous anesthesia. Pituitary effluent plasma β-endorphin and peripheral plasma cortisol concentrations increased during halothane anesthesia only. Dynorphin concentrations did not change in either group. Hyperglycemia developed during intravenous anesthesia only Minimal changes occurred in CSF hormonal concentrations during anesthesia. Conclusion - The pituitary gland has a major role in maintaining circulating peptides during anesthesia. Compared with halothane, IV anesthesia appeared to suppress pituitary secretion.
Resumo:
We estimate the cross sections for the production of resonances, pion pairs, and a central cluster of hadrons in peripheral heavy-ion collisions through two-photon and double-pomeron exchange, at energies that will be available at the Relativistic Heavy Ion Collider (RHIC) and the Large Hadron Collider (LHC). The effect of the impact parameter in the diffractive reactions is introduced, and by imposing the condition for realistic peripheral collisions we verify that in the case of very heavy ions the pomeron-pomeron contribution is indeed smaller than the electromagnetic one. However, they give a non-negligible background in the collision of light ions. This diffractive background will be more important at RHIC than at LHC.
Resumo:
Fatigue crack initiation occurs at the surface, although sub surface nucleation has also been reported. Localized imperfections like inclusions close to surface and surface small pits can result in crack sources. Coatings are not always beneficial by fatigue point of view too. Mechanical properties of the covering material can change considerably the fatigue behavior of base metal due to residual surface stresses, to micro cracks or to hydrogen embrittlement. This paper is concerned with analysis of electrolytic etch on the fatigue resistance of a 35NCD16 high strength steel in a mechanical condition of (1760 - 1960) MPa, and analysis of electroplated hard chromium effects on the fatigue resistance in a strength condition of 989 MPa. Hardness impression was used as a reference parameter in case of electrolytic etch. In both cases, experimental data showed that fatigue strength of 35NCD16 steel was considerably reduced. Copyright © 2001 Society of Automotive Engineers, Inc.
Resumo:
We discuss processes leading to two photon final states in peripheral heavy ion collisions at RHIC. Due to the large photon luminosity we show that the continuum subprocess γγ→ γγ can be observed with a large number of events. We study this reaction when it is intermediated by a resonance made of quarks or gluons and discuss its interplay with the continuum process, verifying that in several cases the resonant process overwhelms the continuum one. It also investigated the possibility of observing a scalar resonance (the σ meson) in this process. Assuming for the σ the mass and total decay width values recently reported by the E791 Collaboration we show that RHIC may detect this particle in its two photon decay mode if its partial photonic decay width is of the order of the ones discussed in the literature.
Resumo:
Purpose: To identify the electromyographic fatigue threshold in the erector spinae muscle. Methods: Eight 19 to 24-year-old male volunteers participated in this study, in which surface electrodes were used, as well as a biological signals acquisition module (Lynx) with a sampling frequency of 1000Hz, a 1000 times gain, a 20Hz high pass filter and a 500Hz low pass filter. The test consisted of repeated isometric contractions of the erector spinae muscle in a 45° hip flexion posture, with 30%, 40%, 50% and 60% of the maximum voluntary isometric contraction. Results: A positive correlation of the RMS (root mean square) value as a function of time was found for most of the subjects with 40% (N = 6), 50% (N = 7) and 60% (N = 8) loads of the maximum voluntary isometric contraction. Conclusions: It was concluded, from this study, that the proposed protocol provides evidence, through the electromyographic signal, of the development of fatigue in the erector spinae muscle with loads of 40%, 50% and 60% of the maximum voluntary isometric contraction. The protocol also allows the electromyographic fatigue threshold and its probable applicability in the diagnosis of this phenomenon during repetitive activities to be determined.
Resumo:
The purpose of this study was to identify the Electromyographic Fatigue Threshold (EMG FT) of the biceps brachii muscle bilaterally during the elbow flexion in tests performed in different times: 30 second test, 1 minute test and fatiguing test, in concentric (CC) and eccentric (EC) phases. Nine healthy young men performed the elbow flexion with loads corresponding at 25%, 35% and 45% of the one repetition maximum (1-RM) in separate days. The results indicated that the test applied for the biceps brachii muscle during elbow flexion induced a progressive increment of EMG activity with time indicating muscle fatigue and allowed the identification of the EMG FT. The three tests presented no difference of EMG FT between CC and EC phases bilaterally.
Resumo:
It is well known that fatigue behaviour is an important parameter to be considered in mechanical components subjected to constant and variable amplitude loadings. In combination with corrosion phenomenon, fatigue effects were responsible for proximally 64% of fails that occur in metallic parts of aeronautical accidents in the last 30 years. Recovered substrates have been extensively used in the aerospace field. Cadmium electroplating has been widely applied to promote protective coatings in aeronautical components, resulting in excellent corrosion protection combined with a good performance in cyclic loading. Ecological considerations allied to the increasing demands for corrosion resistance, resulted in the search for possible alternatives. Zinc-nickel alloys received considerable interest recently, since these coatings showed some advantages such as a good resistance to white and red rust, high plating rates and acceptation in the market. In this study the effects of zinc-nickel coatings electroplated on AISI 4340 high strength steel were analysed on rotating bending and axial fatigue strength, corrosion and adhesion resistance. Compressive residual stress field was measured by a X-ray tensometry prior to fatigue tests. Optical microscopy images showed coating thicknesses, adhesion and the existence of an uniform coverage of nearly all substrates. The fractured fatigue specimens were investigated using a scanning electron microscope. Three different zinc-nickel coating thicknesses were tested and comparison with rotating bending fatigue data from specimens cadmium electroplated and heat treated at 190°C for 3, 8 and 24 hours to avoid the diffusion of hydrogen in the substrate, was performed. Experimental results showed effect of coatings on the AISI 4340 steel behaviour when submitted to fatigue testing and the existence of coating thickness influence on the fatigue strength.
Resumo:
The objective of this study was to analyze the electromyographic (EMG) signal behavior of rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL) and biceps femoris (caput longum) (BFCL) from nine women during fatiguing dynamic and isometric knee extensions tests and to determine their EMGFT (Electromyographic Fatigue Threshold). Surface electrodes, biological signal acquisition module, analogical-digital converter board and specific software were used. The RMS (Root Mean Square) values obtained from concentric phase (80 to 30 degrees) of the dynamic knee extension andfrom isometric contraction were correlated with time on each load by linear regression analysis. The respective slopes were correlated with the correspondent load to determine the EMGFT. Force (Kgf) and median frequency - MF (Hz) obtained during MIVC (Maximal Isometric Voluntary Contraction) performed before and after the fatiguing tests were calculated in Matlab environment. The results demonstrated that the endurance time decreases with higher loads the EMG amplitude increase with time and was greater at higher loads, between muscles in dynamic exercise the RF and VL showed higher slopes, and in isometric exercise the VL showed the same behavior The EMGFT values were similar in both exercises; the force values predominantly decreased after fatiguing tests; however the MF only decreased after some loads. The protocols proposed allowed standardizing protocols at least to induce the fatigue process and to determine the EMGFT as an endurance indicative, which may be used to evaluate the effectiveness of rehabilitative or training interventions indicated to reduce muscle weakness and fatigue.
Resumo:
Purpose: To evaluate the fatigue resistance of the bond between dentin and glass-infiltrated alumina ceramic, using different luting protocols. Materials and Methods: The null hypothesis is that the fatigue resistance varies with the luting strategy. Forty blocks of In-Ceram Alumina were prepared, and one surface of each block was abraded with 110-μm aluminum oxide particles. Then, the blocks were luted to flat dentin surfaces of 40 human third molars, using 4 different luting strategies (luting system [LS]/ceramic surface conditioning [CSC]) (n=10): (G1) [LS] RelyX-Unicem/[CSC] airborne abrasion with 110-μm Al2O3 particles; (G2) [LS] One-Step + Duo-Link (bis-GMA-based resin)/[CSC] etching with 4% hydrofluoric acid + silane agent; (G3) [LS] ED-Primer + Panavia F (MDP-based resin)/[CSC] Al2O 3; (G4) [LS] Scotchbond1+RelyX-ARC (bis-GMA-based resin)/[CSC] chairside tribochemical silica coating (air abrasion with 30-μm SiO x particles + silane). After 24 h of water storage at 37°C, the specimens were subjected to 106 fatigue cycles in shear with a sinusoidal load (0 to 21 N, 8 Hz frequency, 37°C water). A fatigue survivor score was given, considering the number of the fatigue cycles until fracture. The failure modes of failed specimens were observed in a SEM. Results: G3 (score = 5.9, 1 failure) and G4 (score = 6, no failures) were statistically similar (p = 0.33) and had significantly higher fatigue resistance than G1 (score = 3.9, 5 failures) and G2 (score = 3.7, 6 failures) (p < 0.03). SEM analysis of fractured specimens of G1 and G2 showed that almost all the failures were between ceramic and cement. Conclusion: The MDP-based resin cement + sandblasting with Al2O3 particles (G3) and bis-GMA-based resin cement + tribochemical silica coating (G4), both using the respective dentin bonding systems, were the best luting protocols for the alumina ceramic. The null hypothesis was confirmed.
Resumo:
Objectives: The objectives of this study were to assess the fluoride concentration in the public water supply and the prevalence of dental fluorosis in schoolchildren between 7 and 15 years old, living in a peripheral district of the municipality of Bauru. Material and Methods: For this, fifty two water samples were collected on three different days of one week. These samples were analyzed for fluoride by means of the ion-sensitive electrode method (Orion 9609) coupled to a potentiometer (Procyon, model 720). In this method, 1.0 mL of TISAB II (Orion) was added to 1.0 mL of the sample. For the epidemiological survey of fluorosis, 52 schoolchildren of both genders, aged between 7 and 15 were assessed, with prior authorization from their caretakers. Only one person examined the children, after supervised toothbrushing and drying with cotton wool rolls. The TF index was used. Results: The fluoride concentrations in the water samples ranged from 0.62 to 1.20 mg/L, with a mean of 0.9 mg/L. The prevalence of dental fluorosis was 33%, with severity ranging from TF1 to TF4 (Kappa of 0.73 and concordance of 83.33%). Conclusions: The results from the analysis of water samples indicated a fluoride concentration greater than recommended for Bauru. The fluorosis levels found were higher than expected for a peripheral district, in which water is one of the few sources of fluoride.
Resumo:
Objective: Taking into consideration that DNA damage plays an important role in carcinogenesis, the purpose of this study was to evaluate whether regular and white mineral trioxide aggregate (MTA) are able to induce genetic damage in primary human cells. Study design: Human peripheral lymphocytes obtained from 10 healthy volunteers were exposed to 2 presentation forms of MTA at final concentrations ranging from 1 to 1000 μg/mL for 1 hour at 37°C. The negative control group was treated with vehicle control (phosphate buffer solution, PBS) for 1 hour at 37°C and the positive control group was treated with hydrogen peroxide (at 100 μM) for 5 minutes on ice. Results were analyzed by the Friedman nonparametric test. Results: The results pointed out that either regular or white MTA in all concentrations tested did not induce DNA breakage in human peripheral lymphocytes as depicted by the mean tail moment. Conclusion: In summary, our results indicate that exposure to MTA may not be a factor that increases the level of DNA lesions in human peripheral lymphocytes as detected by single cell gel (comet) assay. © 2006 Mosby, Inc. All rights reserved.
Resumo:
Muscle fatigue can be a limiting factor to determine index as the electromyographic fatigue threshold (EMGFT) due the alterations in motivation and disconfots. This way, the purpose of this study was to identify the right biceps brachii and left biceps brachii obtained from repetitive elbow flexions at each 10% of total time. Nine healthy subjects performed the exercise named biceps curl until exhaustion with 25%, 35%, and 45% of one repetition maximum, in three different days. EMG amplitude (root mean square - RMS) was obtained for concentric contractions during these load levels and correlated with time to determine the slope values for each load and them detemine the EMGFT. The EMGFT was obtained within of each 10% of total time and they were compared by analysis of variance. The results showed a progressive increase in RMS with time, for both muscles in all loads, characterizing the muscle fatigue process, and for the EMGFT values ware not found predominantly significant differences between the execution time, as well as between muscles (right biceps × left biceps). This protocol allowed to identify the EMGFT to both muscles during the biceps curl, which was similar at different percentage of total time, indicating the possibility to reduce the length of the contraction test without the need to maintain the contraction until exhaustion. Further studies are needed to evaluate the applicability of this method to determining the effects on performance.
Resumo:
Purpose: This study compared the shear bond strength (SBS) to enamel of rest seats made with a glass-ionomer cement (Fuji IX GP Fast), a resin-modified glass-ionomer cement (Fuji II LC), and a composite resin (Z100 MP) under monotonic and cyclic loading. Materials and Methods: Rest seats were built up onto the lingual surfaces of 80 intact human mandibular incisors. Specimens (n=10) were stored in distilled water at 37°C for 30 days and subjected to shear forces in a universal testing machine (0.5 mm/min) until fracture. The SBS values were calculated (MPa) using the bonding area (9.62 mm2) delimited by adhesive tags. A staircase approach was used to determine the SBS fatigue limit of each material. Specimens were submitted to either 10,000 cycles (5 Hz) or until specimen fracture. A minimum of 15 specimens was tested for each material. Scanning electron microscopy was used to examine the mode of failure. Data were statistically analyzed with one-way ANOVA and Tukey HSD tests (α = 0.05). Results: Z100 MP yielded higher (p < 0.05) SBS (12.25 MPa) than Fuji IX GP Fast (7.21 MPa). No differences were found between Fuji II LC (10.29 MPa) and the other two materials (p > 0.05). Fuji II LC (6.54 MPa) and Z100 MP (6.26 MPa) had a similar SBS limit. Fuji IX GP Fast promoted the lowest (p < 0.05) SBS fatigue limit (2.33 MPa). All samples showed cohesive failure patterns. Conclusion: Fatigue testing can provide a better means of estimating the performance of rest seats made with dental restoratives.