978 resultados para Operational Adaptive Diagnostic Scale - EDAO


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciência e Engenharia de Polímeros e Compósitos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Bioengenharia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To access the incidence of diagnostic errors in the initial evaluation of children with cardiac murmurs. METHODS: We evaluated our 7-years of experience in a public pediatric cardiology outpatient clinic. Of 3692 patients who were sent to the hospital, 2603 presented with a heart murmur and were investigated. Patients for whom a disagreement existed between the initial and final diagnoses were divided into the following 2 groups: G1 (n=17) with an initial diagnosis of an innocent murmur and a final diagnosis of cardiopathy, and G2 (n=161) with an initial diagnosis of cardiopathy and a final diagnosis of a normal heart. RESULTS: In G1, the great majority of patients had cardiac defects with mild hemodynamic repercussions, such as small ventricular septal defect and mild pulmonary stenosis. In G2, the great majority of structural defects were interventricular communication, atrial septal defect and pulmonary valve stenosis. CONCLUSION: A global analysis demonstrated that diagnostic error in the initial evaluation of children with cardiac murmurs is real, reaching approximately 6% of cases. The majority of these misdiagnoses were in patients with an initial diagnosis of cardiopathy, which was not confirmed through later complementary examinations. Clinical cardiovascular examination is an excellent resource in the evaluation of children suspected of having cardiopathy. Immediate outpatient discharge of children with an initial diagnosis of an innocent heart murmur seems to be a suitable approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo tem como objectivo perceber como o clima afectivo (positivo ou negativo) induzido pelo treinador influencia o comportamento táctico e o estado afectivo percepcionado pelos jogadores de futebol Sub-15 do Campeonato Distrital da Associação de Futebol de Lisboa. Seleccionaram-se três equipas que constituíram os três grupos do estudo: grupo de afectividade positiva (GAP), grupo de afectividade negativa (GAN) e o grupo controlo (GC). Após um pré-teste, à excepção do GC, com manifestação de afectividade neutra pelo treinador, os grupos experimentais foram submetidos a situações de afectividade positiva e negativa, durante três sessões de treino. Após este período de intervenção, realizou-se um pós-teste. Avaliou-se afectos percepcionados pelos jogadores, através da escala PANAS e o comportamento táctico, através da largura de jogo da equipa, com base na recolha de dados posicionais, verificando-se a regularidade da largura de jogo através da entropia amostral (SampEn). Foram encontradas diferenças significativas na regularidade do comportamento no GAN ̅ e ̅ mas não se encontraram diferenças nos afectos percepcionados pelos jogadores em nenhum dos grupos. Encontrou-se igualmente uma tendência positiva na largura da equipa no GAP. Os resultados sugerem que o clima afectivo do treinador apresenta-se como um constrangimento ambiental que influência o comportamento táctico dos jogadores. O clima afectivo positivo estabeleceu um aumento da largura da equipa, mostrando-se viável à procura de comportamentos adaptativos para a consecução de objectivos estabelecidos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been well documented that the optimum feedstock for anaerobic digesters consists of readily biodegradable compounds, as found in primary sludge or even a mixed substrate of primary and excess activated sludge. Due to the requirements of the Urban Wastewater Treatment Plant Directive of 1991, the quantities of secondary sludge generated is set to increase substantially. A pilot scale study was undertaken to evaluate the performance of both Mesophilic Anaerobic Digestion and Thermophilic Aerobic digestion in the treatment of secondary sludge. The results indicated that the anaerobic pilot scale digester achieved a greater solids destruction than the aerobic pilot plant averaging at 28% T.S. removal verses 20% for the aerobic digester, despite the fact that secondary sludge is the optimum feedstock for aerobic digestion. This can, however, be attributed to the greater biomass yield experienced with aerobic systems, and to the absence of Autothermal conditions. At present, the traditional technique of Mesophilic Anaerobic Digestion is in widespread application throughout Ireland, for the stabilisation of sewage sludge. There is only one Autothermal Thermophilic Aerobic Digester at present situated in Killarney, Co. Kerry. A further objectives of the study was to compare full-scale applications of Mesophilic Anaerobic Digestion to ATAD. Two Sludge Treatment plants, situated in Co. Kerry, were used for this purpose, and were assessed mainly under the following headings; process stability, solids reduction on average, the ATAD plant in Killarney has the advantage of producing a “Class A” Biosolid in terms of pathogen reduction, and can effectively treat double the quantity of sludge. In addition, economically the ATAD plant is cheaper to run, costing €190 / t.d.s verses €211 / t.d.s. for the anaerobic digester in Tralee. An overview of additional operational Anaerobic Digestion Plants throughout Ireland is also presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zugl.: Magdeburg, Univ., Fak. für Informatik, Diss., 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reaction-diffusion problems, finite elements, unstructured grid, grid adaption, W-method, stiffness, local partitioning, excitable medium, spiral wave drift

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Handschrifterkennung, Wortsegmentierung, strukturelle Ziffernerkennung, strukturelle Worterkennung, Anpassung, Anpassbarkeit, historische Dokumente, Kirchenbücher, robuste Worterkennung

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Informatik, Diss., 2007

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gastrointestinal cancers, HCC, ectopeptidases, differential display, gasdermin-like

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The diagnostic accuracy of 64-slice MDCT in comparison with IVUS has been poorly described and is mainly restricted to reports analyzing segments with documented atherosclerotic plaques. Objectives: We compared 64-slice multidetector computed tomography (MDCT) with gray scale intravascular ultrasound (IVUS) for the evaluation of coronary lumen dimensions in the context of a comprehensive analysis, including segments with absent or mild disease. Methods: The 64-slice MDCT was performed within 72 h before the IVUS imaging, which was obtained for at least one coronary, regardless of the presence of luminal stenosis at angiography. A total of 21 patients were included, with 70 imaged vessels (total length 114.6 ± 38.3 mm per patient). A coronary plaque was diagnosed in segments with plaque burden > 40%. Results: At patient, vessel, and segment levels, average lumen area, minimal lumen area, and minimal lumen diameter were highly correlated between IVUS and 64-slice MDCT (p < 0.01). However, 64-slice MDCT tended to underestimate the lumen size with a relatively wide dispersion of the differences. The comparison between 64-slice MDCT and IVUS lumen measurements was not substantially affected by the presence or absence of an underlying plaque. In addition, 64-slice MDCT showed good global accuracy for the detection of IVUS parameters associated with flow-limiting lesions. Conclusions: In a comprehensive, multi-territory, and whole-artery analysis, the assessment of coronary lumen by 64-slice MDCT compared with coronary IVUS showed a good overall diagnostic ability, regardless of the presence or absence of underlying atherosclerotic plaques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluidized beds, granulation, heat and mass transfer, calcium dynamics, stochastic process, finite element methods, Rosenbrock methods, multigrid methods, parallelization

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractBackground:Myocardial perfusion scintigraphy (MPS) in patients not reaching 85% of the maximum predicted heart rate (MPHR) has reduced sensitivity.Objectives:In an attempt to maintain diagnostic sensitivity without losing functional exercise data, a new exercise and dipyridamole combined protocol (EDCP) was developed. Our aim was to evaluate the feasibility and safety of this protocol and to compare its diagnostic sensitivity against standard exercise and dipyridamole protocols.Methods:In patients not reaching a sufficient exercise (SE) test and with no contraindications, 0.56 mg/kg of dipyridamole were IV administered over 1 minute simultaneously with exercise, followed by 99mTc-MIBI injection.Results:Of 155 patients, 41 had MPS with EDCP, 47 had a SE test (≥ 85% MPHR) and 67 underwent the dipyridamole alone test (DIP). They all underwent coronary angiography within 3 months. The three stress methods for diagnosis of coronary lesions had their sensitivity compared. For stenosis ≥ 70%, EDCP yielded 97% sensitivity, SE 90% and DIP 95% (p = 0.43). For lesions ≥ 50%, the sensitivities were 94%, 88% and 95%, respectively (p = 0.35). Side effects of EDCP were present in only 12% of the patients, significantly less than with DIP (p < 0.001).Conclusions:The proposed combined protocol is a valid and safe method that yields adequate diagnostic sensitivity, keeping exercise prognostic information in patients unable to reach target heart rate, with fewer side effects than the DIP.