925 resultados para Nerve-conduction-velocity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative wear and corrosion properties of Cr3C2-NiCr (CC-TS) (a high-velocity oxyfuel [HVOF]) and hard chromium (HC) coating's obtained on a steel substrate have been studied. The structural characterization was done before and after measurements by optical microscopy, scanning electron microscopy, and scanning white light interferometry. Wear and corrosion properties were evaluated by ball on disk (ASTM G99-90), rubber wheel (ASTM G65-91), and electrochemical measurements of open circuit and polarization curves. The best corrosion and wear resistance was for the CC-TS obtained by HVOF. The open-circuit potential values measured for both samples after 18 h of immersion we're: -0.240 and -0.550 V, respectively, for CC-TS and HC, versus Ag/AgCl,KClsat. Three orders of magnitude lower volume loss were found for CC-TS (HVOF) after friction tests compared with HC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVO: Cirurgias artroscópicas do ombro cursam com intensa dor pós-operatória. Diversas técnicas analgésicas têm sido preconizadas. O objetivo deste estudo foi comparar o bloqueio dos nervos supraescapular e axilar nas cirurgias artroscópicas de ombro com a abordagem interescalênica do plexo braquial. MÉTODO: Sessenta e oito pacientes foram alocados em dois grupos de 34, de acordo com a técnica utilizada: grupo interescalênico (GI) e grupo seletivo (GS), sendo ambas as abordagens realizadas com neuroestimulador. No GI, após resposta motora adequada foram injetados 30 mL de levopubivacaína em excesso enantiomérico de 50% a 0,33% com adrenalina 1:200.000. No GS, após resposta motora do nervo supraescapular e axilar, foram injetados 15 mL da mesma substância em cada nervo. em seguida, realizada anestesia geral. Variáveis avaliadas: tempo para realização dos bloqueios, analgesia, consumo de opioide, bloqueio motor, estabilidade cardiocirculatória, satisfação e aceitabilidade pelo paciente. RESULTADOS: Tempo para execução do bloqueio interescalênico foi significativamente menor que para realização do bloqueio seletivo. Analgesia foi significativamente maior no pós-operatório imediato no GI e no pós-operatório tardio no GS. Consumo de morfina foi significativamente maior na primeira hora no GS. Bloqueio motor foi significativamente menor no GS. Estabilidade cardiocirculatória, satisfação e aceitabilidade da técnica pelo paciente não diferiram entre os grupos. Ocorreu uma falha no GI e duas no GS. CONCLUSÕES: Ambas as técnicas são seguras, eficazes com mesmo grau de satisfação e aceitabilidade. O bloqueio seletivo de ambos os nervos apresentou analgesia satisfatória, com a vantagem de proporcionar bloqueio motor restrito ao ombro.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Air flow through packed beds was analyzed experimentally under conditions ranging from those that reinforce the effect of the wall on the void fraction to those that minimize it. The packing was spherical particles, with a tube-to-particle diameter ratio (D/dp) between 3 and 60. Air flow rates were maintained between 1.3 and 4.44 m3/min, and gas velocity was measured with a Pitot tube positioned above the bed exit. Measurements were made at various radial and angular coordinate values, allowing the distribution of air flow across the bed to be described in detail. Comparison of the experimentally observed radial profiles with those derived from published equations revealed that at high D/dp ratios the measured and calculated velocity profiles behaved similarly. At low ratios, oscillations in the velocity profiles agreed with those in the voidage profiles, signifying that treating the porous medium as a continuum medium is questionable in these cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram utilizados dez ovinos da raça Corriedale - cinco machos e cinco fêmeas com pesos entre 52,2 e 87,6 kg - com o objetivo de avaliar o efeito da combinação da movimentação do ar (0 e 5,0 m/s) com a temperatura do ar (25, 30 e 40ºC) sobre a temperatura retal (T R, ºC), da epiderme (T E, ºC), da superfície do velo (T V, ºC) e do interior do velo (T I, ºC) e a espessura do velo (E V, cm) e suas relações com o isolamento térmico do velo. A presença de vento não teve efeito sobre as variáveis estudadas, o que sugere que fluxo de ar (<5,0 m/s) paralelo ao eixo corporal do animal tem pouco efeito sobre o isolamento térmico do velo, independentemente da temperatura do ar, que se mostrou altamente correlacionada, de forma positiva, com as temperaturas retal, do velo, do interior do velo e da epiderme. Sob temperaturas inferiores a 30ºC, a transferência de calor através do velo ocorreu via condução e convecção livre, enquanto sob altas temperaturas (>40ºC) o fluxo de calor sensível não foi significativa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied a new type of end-to-side nerve repair in rats. The healthy (donor) nerve was not divided but an epineural window was created. In our experiment, a nerve graft bridged the tibial nerve to the distal end of the divided peroneal nerve. Electrophysiological studies showed electrical impulses conducted through both end-to-side nerve junctions. Histological studies demonstrated axons leaving the lateral surface of the healthy (donor) nerve. Based on these observations, we suggest that end-to-side neurorrhaphy from a healthy nerve may bridge a neural deficit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sharp transitions are perhaps absent in QCD, so that one looks for physical quantities which may reflect the phase change. One such quantity is the sound velocity which was shown in lattice theory to become zero at the transition point for pure glue. We show that even in a simple bag model the sound velocity goes to zero at temperature T = T(v) not-equal 0 and that the numerical value of this T(v) depends on the nature of the meson. The average thermal energy of mesons goes linearly with T near T(v), with much smaller slope for the pion. The T(v) - s can be connected with the Boltzmann temperatures obtained from transverse momentum spectrum of these mesons in heavy-ion collision at mid-rapidity. It would be interesting to check the presence of different T(v) - s in present day finite T lattice theory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electric properties of the sodium niobate perovskite ceramic were investigated by impedance spectroscopy in the frequency range from 5 Hz to 13 MHz and from room temperature up to 1073 K, in a thermal cycle. Both capacitance and conductivity exhibit an anomaly at around 600 K as a function of the temperature and frequency. The electric conductivity as a function of angular frequency sigma(omega) follows the relation sigma(omega)=Aomega(s). The values of the exponent s lie in the range 0.15less than or equal tosless than or equal to0.44. These results were discussed considering the conduction mechanism as being a type of polaron hopping. (C) 2003 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The running velocities associated to lactate minimum (V-lm), heart rate deflection (V-HRd), critical velocity (CV), 3000 M (V-3000) and 10000 m performance (V-10km) were compared. Additionally the ability of V-lm and VHRd on identifying sustainable velocities was investigated.Methods. Twenty runners (28.5 +/- 5.9 y) performed 1) 3000 m running test for V3000; 2) an all-out 500 in sprint followed by 6x800 m incremental bouts with blood lactate ([lac]) measurements for V-lm; 3) a continuous velocity-incremented test with heart rate measurements at each 200 m for V-HRd; 4) participants attempted to 30 min of endurance test both at V-lm(ETVlm) and V-HRd(ETVHRd). Additionally, the distance-time and velocity-1/time relationships produced CV by 2 (500 m and 3000 m) or 3 predictive trials (500 m, 3000 m and distance reached before exhaustion during ETVHRd), and a 10 km race was recorded for V-10km.Results. The CV identified by different methods did not differ to each other. The results (m(.)min(-1)) revealed that V-.(lm) (281 +/- 14.8)< CV (292.1 +/- 17.5)=V-10km (291.7 +/- 19.3)< V-HRd (300.8 +/- 18.7)=V-3000 (304 +/- 17.5) with high correlation among parameters (P < 0.001). During ETVlm participants completed 30 min of running while on the ETVHRd they lasted only 12.5 +/- 8.2 min with increasing [lac].Conclusion. We evidenced that CV and Vim track-protocols are valid for running evaluation and performance prediction and the parameters studied have different significance. The V-lm reflects the moderate-high intensity domain (below CV), can be sustained without [lac] accumulation and may be used for long-term exercise while the V-HRd overestimates a running intensity that can be sustained for long-time. Additionally, V-3000 and V-HRd reflect the severe intensity domain (above CV).