975 resultados para NEUTRON LEAKAGE
Resumo:
Head space gas chromatography with flame-ionization detection (HS-GC-FID), ancl purge and trap gas chromatography-mass spectrometry (P&T-GC-MS) have been used to determine methyl-tert-butyl ether (MTBE) and benzene, toluene, and the ylenes (BTEX) in groundwater. In the work discussed in this paper measures of quality, e.g. recovery (94-111%), precision (4.6 - 12.2%), limits of detection (0.3 - 5.7 I~g L 1 for HS and 0.001 I~g L 1 for PT), and robust-ness, for both methods were compared. In addition, for purposes of comparison, groundwater samples from areas suffering from odor problems because of fuel spillage and tank leakage were analyzed by use of both techniques. For high concentration levels there was good correlation between results from both methods.
Resumo:
We have explored the threshold of tolerance of three unrelated cell types to treatments with potential cytoprotective peptides bound to Tat(48-57) and Antp(43-58) cell-permeable peptide carriers. Both Tat(48-57) and Antp(43-58) are well known for their good efficacy at crossing membranes of different cell types, their overall low toxicity, and their absence of leakage once internalised. Here, we show that concentrations of up to 100 microM of Tat(48-57) were essentially harmless in all cells tested, whereas Antp(43-58) was significantly more toxic. Moreover, all peptides bound to Tat(48-57) and Antp(43-58) triggered significant and length-dependent cytotoxicity when used at concentrations above 10 microM in all but one cell types (208F rat fibroblasts), irrespective of the sequence of the cargo. Absence of cytotoxicity in 208F fibroblasts correlated with poor intracellular peptide uptake, as monitored by confocal laser scanning fluorescence microscopy. Our data further suggest that the onset of cytotoxicity correlates with the activation of two intracellular stress signalling pathways, namely those involving JNK, and to a lesser extent p38 mitogen-activated protein kinases. These responses are of particular concern for cells that are especially sensitive to the activation of stress kinases. Collectively, these results indicate that in order to avoid unwanted and unspecific cytotoxicity, effector molecules bound to Tat(48-57) should be designed with the shortest possible sequence and the highest possible affinity for their binding partners or targets, so that concentrations below 10 microM can be successfully applied to cells without harm. Considering that cytotoxicity associated to Tat(48-57)- and Antp(43-58) bound peptide conjugates was not restricted to a particular type of cells, our data provide a general framework for the design of cell-penetrating peptides that may apply to broader uses of intracellular peptide and drug delivery.
Resumo:
The Iowa Department of Transportation used a high molecular weight methacrylate (HMWM) resin to seal a 3,340 ft. x 64 ft. bridge deck in October 1986. The sealing was necessary to prevent deicing salt brine from entering a substantial number of transverse cracks that coincided with the epoxy coated top steel and unprotected bottom steel. HMWM resin is a three component product composed of a monomer, a curnene hydroperoxide initiator and a cobalt naphthenate promoter. The HMWM was applied with a dual spray bar system and flat-fan nozzles. Initiated monomer delivered through one spray bar was mixed in the air with promoted monomer from the other spray bar. The application rate averaged 0.956 gallons per 100 square feet for the tined textured driving lanes. Dry sand was broadcast on the surface at an average coverage of 0.58 lbs. per square yard to maintain friction. Coring showed that the H.MWM resin penetrated the cracks more than two inches deep. Testing of the treated deck yielded Friction Numbers averaging 33 with a treaded tire compared to 36 prior to treatment. An inspection soon after treatment found five leaky cracks in one of the 15 spans. One inspection during a steady rain showed no leakage, but leakage from numerous cracks occurred during a subsequent rain. A second HMWM application was made on two spans to determine if a double application would prevent leakage. This evaluation has not been completed.
Resumo:
Recombinant adeno-associated virus (rAAV) are effective gene delivery vehicles that can mediate long-lasting transgene expression. However, tight regulation and tissue-specific transgene expression is required for certain therapeutic applications. For regulatable expression from the liver we designed a hepatospecific bidirectional and autoregulatory tetracycline (Tet)-On system (Tet(bidir)Alb) flanked by AAV inverted terminal repeats (ITRs). We characterized the inducible hepatospecific system in comparison with an inducible ubiquitous expression system (Tet(bidir)CMV) using luciferase (luc). Although the ubiquitous system led to luc expression throughout the mouse, luc expression derived from the hepatospecific system was restricted to the liver. Interestingly, the induction rate of the Tet(bidir)Alb was significantly higher than that of Tet(bidir)CMV, whereas leakage of Tet(bidir)Alb was significantly lower. To evaluate the therapeutic potential of this vector, an AAV-Tet(bidir)-Alb-expressing interleukin-12 (IL-12) was tested in a murine model for hepatic colorectal metastasis. The vector induced dose-dependent levels of IL-12 and interferon-γ (IFN-γ), showing no significant toxicity. AAV-Tet(bidir)-Alb-IL-12 was highly efficient in preventing establishment of metastasis in the liver and induced an efficient T-cell memory response to tumor cells. Thus, we have demonstrated persistent, and inducible in vivo expression of a gene from a liver-specific Tet-On inducible construct delivered via an AAV vector and proved to be an efficient tool for treating liver cancer.
Resumo:
This study investigates, designs, and implements an inexpensive application that allows local and remote monitoring of a home. The application consists of an array of sensors for monitoring different conditions in a home environment and also for accessing the devices that might be connected to the system. Only a few sensors are initially involved in this study and information about the temperature level, forced entry detection, smoke and water leakage detection can be obtained at any time from any location with an Internet connection. The application software (coded in C language) runs on an embedded system which is basically a wireless Linksys router running on a GNU/Linux based firmware for embedded systems. Interaction between the sensors and the application software is achieved through an implemented sensor interfacing circuit. The communication with the sensor interfacing unit is done through the serial port, and accessibility of the connected sensors is achieved through a telnet client. The sensors can be accessed from local and remote locations with the sensors giving reliable information. The resulting application shows that it is possible to use the router for other applications other than what it is intended for.
Resumo:
Nanotiltration is a membrane separation method known for its special characteristic of rejecting multivalent ions and passing monovalent ions. Thus, it is commonly applied with dilute aqueous solutions in partial salt removal, like in drinking water production. The possibilities of nanofiltration have been studied and the technique applied in a wide branch of industries, e.g. the pulp and paper, the textile and the chemical processing industry. However, most present applications and most of the potential applications studied involve dilute solutions, the permeating stream being generally water containing monovalent salts. In this study nanotiltration is investigated more as a fractionation method. A well-known application in the dairy industry is concentration and partial salt removal from whey. Concentration and partial demineralization is beneficial for futher processing of whey as whey concentrates are used e.g. in baby foods. In the experiments of this study nanotiltration effectively reduced the monovalent salts in the whey concentrate. The main concern in this application is lactose leakage into the permeate. With the nanofiltration membranes used the lactose retentions were practically ? 99%. Another dairy application studied was the purification and reuse of cleaning solutions. This is an environmentally driven application. An 80% COD reduction by nanofiltration was observed for alkaline cleaning-in-place solution. Nanofiltration is not as commonly applied in the sugar and sweeteners industry as in the dairy industry. In this study one potential application was investigated, namely xylose purification from hemicellulose hydrolyzate. Xylose is raw material for xylitol production. Xylose separation from glucose was initially studied with xylose-glucose model solutions. The ability of nanofiltration to partially separate xylose into the permeate from rather concentrated xylose-glucose solutions (10 w-% and 30 w-%) became evident. The difference in size between xylose and glucose molecules according to any size measure is small, e.g. the Stokes diameter of glucose is 0.73 nm compared to 0.65 nm for xylose. In further experiments, xylose was purified into nanoliltration permeate from a hemicellulose hydrolyzate solution. The xylose content in the total solids was increased by 1.4—1.7 fold depending on temperature, pressure and feed composition.
Resumo:
Diplomityössä tutkittiin Loviisan voimalaitoksen primääri- ja sekundääripiirin aktiivisuusmittausten kykyä tunnistaa pienet primääri-sekundäärivuodot. Tarkasteltavat primääri-sekundäärivuotojen suuruudet valittiin laitoksen hätätilanne- ja häiriönselvitysohjeiden mukaisesti. Vuodon vaikutuksia arvioitiin erilaisilla primäärijäähdytteen ominaisaktiivisuuksilla. Ominaisaktiivisuudet primääripiirissä määritettiin nuklidikohtaisesti erilaisille polttoainevuototapauksille. Työssä huomioitiin myös transienteissa mahdollisesti esiintyvä primääripiirin aktiivisuustasoa nostava spiking-ilmiö. Vuodon tarkempaa tunnistamista varten työssä laskettiin tarkasteltaville mittareille kalibrointikertoimet. Primääri-sekundäärivuoto mallinnettiin APROS-simulointiohjelmalla laitoksen eri käyttötiloissa ja kahdella eri vuotokoolla. Varsinainen aktiivisuuslaskenta suoritettiin SEKUN-ohjelmalla. Työssä tätä aktiivisuus- ja päästölaskentaohjelmaa muokattiin ohjelmoimalla siihen tarkasteltavat aktiivisuusmittaukset sekä primääripiirin puhdistus ja ulospuhallus. Laskelmien tuloksena saatiin arviot kunkin tarkasteltavana olleen aktiivisuusmittauksen soveltuvuudesta primääri-sekundäärivuodon tunnistamiseen erilaisissa polttoainevuototapauksissa ja reaktorin eri tehotasoilla. Häiriönselvitysohje I3:n käyttöönottoa edellyttävät vuotokoot määritettiin aktiivisuusmittausten havaitseman perusteella. Erityisesti kuumavalmiustilassa tapauksissa, joissa reaktorisydämessä oletetaan olevan tiiveytensä menettäneitä polttoainesauvoja, spikingin vaikutus jäähdytteiden aktiivisuuspitoisuuksiin ja mittaustuloksiin oli merkittävä. Niiltä osin, kuin tulokset käsittelevät ohjeissa vuodon tunnistamiseen käytettyjä aktiivisuusrajoja, tulokset osoittivat aktiivisuusrajat oikeiksi. Kuumavalmiudessa aktiivisuusmittausten mittausalueet saattavat joissakin tapauksissa rajoittaa primääri-sekundäärivuodon tunnistamista.
Resumo:
Tämän diplomityön oleellisempana tavoitteena oli tutkia ioninvaihtohartsien pitkäaikaista toiminnallista lämpötilakestävyyttä kirjallisuustutkimuksin ja kuormituskokein. Lisaksi työssä optimoitiin taloudellisesti ja teknisesti paras kytkentävaihtoehto soodakattilan lauhteenpuhdistuslaitokselle. Tässä diplomityössä selvitettiin myös soodakattilan ulospuhallusveden sisältämien veden jälkiannostelukemikaalien ja epäpuhtauksien vaikutusta ioninvaihtohartsien vanhenemiseen.; Ioninvaihtohartsien lämpötilakestävyyteen liittyvät koeajot suoritettiin Stora Enso Laminating Papers Oy Kotkan tehtaalla. Koeajoja varten oli erikseen suunniteltu koeajolaitteisto, jossa lauhdenäytettä puhdistettiin patruunasuotimella ja sekavaihtimella. Sekavaihtimessa käytettiin vahvoja anioni- ja kationihartseja. Koeajoja oli yhteensä neljäkappaletta ja niissä tutkittiin hartsien lämpötilakestävyyttä ja anionihartsin silikaatti-vuodon riippuvuutta lämpötilasta. Lämpötilakestävyyskoeajoissa käytetyt hartsit lähetettiin Rohm and Haasille analysoitavaksi. Lopulta koeajojen tuloksia verrattiin kirjallisuudessa esitettyihin aikaisempiin tutkimuksiin. Lauhteenpuhdistuslaitoksen kytkentävaihtoehtojen optimoinnissa käytettiin apuna Kotkan ja UPM-Kymmene Oyj Pietarsaaren tehtaiden kokemuksia. Kytkentävaihtoehtojen energiataseet laskettiin kuudelle eri laitokselle, joiden syöttöveden virtaukset olivat 37 -180 kg/s. Lisaksi selvitettiin kytkentävaihtoehtojen investointikustannukset ja kertakäyttöhartsien vuotuiset kustannukset laitokselle, jossa syöttöveden virtaus oli 67 kg/s. Ulospuhalluksen talteenottojärjestelmän energiataseet laskettiin kuudelle eri laitokselle, joiden syöttöveden virtaukset olivat 37 - 180 kg/s. Laskelmien lähtökohtana käytettiin kunkin soodakattilan ulospuhallusveden määriä, jotka selvitettiin tehdasvierailujen yhteydessä. Ulospuhallusveden epäpuhtauksien ja jälkiannostelukemikaalien pitoisuudet arvioitiin kattilaveden perusteella. Aikaisempien kokemusten perusteella arvioitiin, että ulospuhallusvesi johdettaisiin lisäveden valmistukseen ennen suolanpoistosarjoja. loninvaihtohartsien kuormituskokeiden ja kirjallisuustutkimusten perusteella oli selkeästi nähtävissä, että etenkin anionihartsin kapasiteetti heikkeni nopeasti lämpötilan ollessa yli 60 °C. Kationihartsin suolanpoistolle kriittinen lämpötilaraja on 100 °C.Lisäksi yli 60 °C:ssa anionihartsi ei pysty poistamaan silikaattia lauhteesta. Seuraavaksi on esitelty lauhteenpuhdistuslaitoksen optimikytkentävaihtoehdot sekä vanhoille että uusille laitoksille. Vanhalle laitokselle, jossa lauhteet on puhdistettu aikaisemmin mekaanisella suotimella ja lisäveden puhdistuksessa on käytetty sekavaihdinta, paras kytkentävaihto on erilliset sekavaihtimet lauhteelle ja lisävedelle. Uudelle ja vanhalle laitokselle, jossa lauhteet on puhdistettu aikaisemmin mekaanisella suotimella ja lisäveden puhdistuksessa ei ole käytetty sekavaihdinta, paras kytkentävaihto on yhteiset sekavaihtimet lauhteelle ja lisävedelle. Lauhteen puhdistuksessa käytetyt sekavaihtimen toimintalämpötila on 45 °C molemmissa kytkentävaihtoehdoissa. Kertakäyttöhartsien käyttö osoittautui suuressa mittakaavassa kannattamattomaksi. Tämä asia tarvinnee kuitenkin jatkotutkimuksia. Ulospuhallusveden talteenotolla saadaan energiasäästöä 6-53 k¤/a riippuenlaitoksesta. Etenkin soodakattilalaitoksissa, joissa soodakattila ja vedenkäsittelylaitos sijaitsevat lähellä toisiaan, kannattaa ulospuhallusvesi johtaa lisäveden valmistukseen. Jos edellä mainittujen laitosten etäisyydet kasvavat, saattavat ulospuhallusjärjestelmän investointi-kustannukset nousta kohtuuttoman suureksi. Tämä työ osoitti myös, että ulospuhallusveden epäpuhtauksilla ei ole merkittävää vaikutusta kemiallisesti puhdistetun veden laatuun ennen suolanpoistolaitosta ja ioninvaihtohartsien vanhenemiseen.
Resumo:
The solid-rotor induction motor provides a mechanically and thermally reliable solution for demanding environments where other rotor solutions are prohibited or questionable. Solid rotors, which are manufactured of single pieces of ferromagnetic material, are commonly used in motors in which the rotationspeeds exceed substantially the conventional speeds of laminated rotors with squirrel-cage. During the operation of a solid-rotor electrical machine, the rotor core forms a conductor for both the magnetic flux and the electrical current. This causes an increase in the rotor resistance and rotor leakage inductance, which essentially decreases the power factor and the efficiency of the machine. The electromagnetic problems related to the solid-rotor induction motor are mostly associated with the low performance of the rotor. Therefore, the main emphasis in this thesis is put on the solid steel rotor designs. The rotor designs studied in thisthesis are based on the fact that the rotor construction should be extremely robust and reliable to withstand the high mechanical stresses caused by the rotational velocity of the rotor. In addition, the demanding operation environment sets requirements for the applied materials because of the high temperatures and oxidizing acids, which may be present in the cooling fluid. Therefore, the solid rotors analyzed in this thesis are made of a single piece of ferromagnetic material without any additional parts, such as copper end-rings or a squirrel-cage. A pure solid rotor construction is rigid and able to keep its balance over a large speed range. It also may tolerate other environmental stresses such as corroding substances or abrasive particles. In this thesis, the main target is to improve the performance of an induction motor equipped with a solid steel rotor by traditional methods: by axial slitting of the rotor, by selecting a proper rotor core material and by coating the rotor with a high-resistive stainless ferromagnetic material. In the solid steel rotor calculation, the rotor end-effects have a significant effect on the rotor characteristics. Thus, the emphasis is also put on the comparison of different rotor endfactors. In addition, a corrective slip-dependent end-factor is proposed. The rotor designs covered in this thesis are the smooth solid rotor, the axially slitted solid rotor and the slitted rotor having a uniform ferromagnetic coating cylinder. The thesis aims at design rules for multi-megawatt machines. Typically, mega-watt-size solidrotor machines find their applications mainly in the field of electric-motor-gas-compression systems, in steam-turbine applications, and in various types of largepower pump applications, where high operational speeds are required. In this thesis, a 120 kW, 10 000 rpm solid-rotor induction motor is usedas a small-scale model for such megawatt-range solid-rotor machines. The performance of the 120 kW solid-rotor induction motors is determined by experimental measurements and finite element calculations.
Resumo:
In order that the radius and thus ununiform structure of the teeth and otherelectrical and magnetic parts of the machine may be taken into consideration the calculation of an axial flux permanent magnet machine is, conventionally, doneby means of 3D FEM-methods. This calculation procedure, however, requires a lotof time and computer recourses. This study proves that also analytical methods can be applied to perform the calculation successfully. The procedure of the analytical calculation can be summarized into following steps: first the magnet is divided into slices, which makes the calculation for each section individually, and then the parts are submitted to calculation of the final results. It is obvious that using this method can save a lot of designing and calculating time. Thecalculation program is designed to model the magnetic and electrical circuits of surface mounted axial flux permanent magnet synchronous machines in such a way, that it takes into account possible magnetic saturation of the iron parts. Theresult of the calculation is the torque of the motor including the vibrations. The motor geometry and the materials and either the torque or pole angle are defined and the motor can be fed with an arbitrary shape and amplitude of three-phase currents. There are no limits for the size and number of the pole pairs nor for many other factors. The calculation steps and the number of different sections of the magnet are selectable, but the calculation time is strongly depending on this. The results are compared to the measurements of real prototypes. The permanent magnet creates part of the flux in the magnetic circuit. The form and amplitude of the flux density in the air-gap depends on the geometry and material of the magnetic circuit, on the length of the air-gap and remanence flux density of the magnet. Slotting is taken into account by using the Carter factor in the slot opening area. The calculation is simple and fast if the shape of the magnetis a square and has no skew in relation to the stator slots. With a more complicated magnet shape the calculation has to be done in several sections. It is clear that according to the increasing number of sections also the result will become more accurate. In a radial flux motor all sections of the magnets create force with a same radius. In the case of an axial flux motor, each radial section creates force with a different radius and the torque is the sum of these. The magnetic circuit of the motor, consisting of the stator iron, rotor iron, air-gap, magnet and the slot, is modelled with a reluctance net, which considers the saturation of the iron. This means, that several iterations, in which the permeability is updated, has to be done in order to get final results. The motor torque is calculated using the instantaneous linkage flux and stator currents. Flux linkage is called the part of the flux that is created by the permanent magnets and the stator currents passing through the coils in stator teeth. The angle between this flux and the phase currents define the torque created by the magnetic circuit. Due to the winding structure of the stator and in order to limit the leakage flux the slot openings of the stator are normally not made of ferromagnetic material even though, in some cases, semimagnetic slot wedges are used. In the slot opening faces the flux enters the iron almost normally (tangentially with respect to the rotor flux) creating tangential forces in the rotor. This phenomenon iscalled cogging. The flux in the slot opening area on the different sides of theopening and in the different slot openings is not equal and so these forces do not compensate each other. In the calculation it is assumed that the flux entering the left side of the opening is the component left from the geometrical centre of the slot. This torque component together with the torque component calculated using the Lorenz force make the total torque of the motor. It is easy to assume that when all the magnet edges, where the derivative component of the magnet flux density is at its highest, enter the slot openings at the same time, this will have as a result a considerable cogging torque. To reduce the cogging torquethe magnet edges can be shaped so that they are not parallel to the stator slots, which is the common way to solve the problem. In doing so, the edge may be spread along the whole slot pitch and thus also the high derivative component willbe spread to occur equally along the rotation. Besides forming the magnets theymay also be placed somewhat asymmetric on the rotor surface. The asymmetric distribution can be made in many different ways. All the magnets may have a different deflection of the symmetrical centre point or they can be for example shiftedin pairs. There are some factors that limit the deflection. The first is that the magnets cannot overlap. The magnet shape and the relative width compared to the pole define the deflection in this case. The other factor is that a shifting of the poles limits the maximum torque of the motor. If the edges of adjacent magnets are very close to each other the leakage flux from one pole to the other increases reducing thus the air-gap magnetization. The asymmetric model needs some assumptions and simplifications in order to limit the size of the model and calculation time. The reluctance net is made for symmetric distribution. If the magnets are distributed asymmetrically the flux in the different pole pairs will not be exactly the same. Therefore, the assumption that the flux flows from the edges of the model to the next pole pairs, in the calculation model from one edgeto the other, is not correct. If it were wished for that this fact should be considered in multi-pole pair machines, this would mean that all the poles, in other words the whole machine, should be modelled in reluctance net. The error resulting from this wrong assumption is, nevertheless, irrelevant.
Resumo:
Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.
Resumo:
Background:Microcystic macular edema can occur after optic neuropathies of various etiologies, and is easily demonstrated by OCT. We report a cohort of patients with microcystic macular edema. Patients and Methods: All patients with optic neuropathy and microcystic macular edema were enrolled. Demographics, visual function, retinal angiographies and OCT parameters were studied. Results: Nineteen patients (23 eyes) exhibited microcystic macular edema: 10 men/9 women, aged 17-91 years. Etiologies of optic nerve atrophy were compressive (5), inflammatory (4), glaucoma (3), ischemic (3), trauma (2), degenerative (1), and hereditary (1). Median visual acuity was 4/10 (NLP-12/10). Fluorescein angiography showed no leakage. Topography of the microcystic macular edema correlated with near infrared images but with visual field defects in only 26 %. OCT parameters were all abnormal. Conclusions: Microcystic macular edema is a non-specific manifestation from an optic neuropathy of any etiology. The precise mechanism leading to microcystic macular edema remains unknown but trans-synaptic retrograde degeneration with Müller cells dysfunction is likely.
Resumo:
Background: The purpose of this contribution is to report our functional results on the efficacy of intravitreal ranibizumab for submacular choroidal neovessels (CNV) in high myopia, and to compare the roles of optical coherence tomography (OCT), fluorescein angiography and visual acuity changes in the treatment decision prior to each injection. Patients and Methods: This is a retrospective study performed in Jules Gonin Eye Hospital. It included all patients with myopic CNV treated with intravitreal ranibizumab injections with a minimum follow-up of 24 months. After an induction dosing from 1 to 3 injections, the follow-up was based on a pro re nata regimen. Ophthalmic evaluation, best corrected visual acuity, and OCT were done at each visit, and fluorescein angiography at baseline and if neovascular activity was suspected. Retreatment criteria included metamorphopsia, visual loss of ≥ 5 ETDRS letters, any fluid on OCT and/or leakage on fluorescein angiography. Results: 24 eyes were included in the study. Mean follow-up was 49 months. Mean visual acuity improved significantly from 62.8 ± 13.8 letters at baseline to 72.8 ± 12.9 letters at last follow-up visit (p = 0.001). The mean number of injections was 2.2 in the first year and below 1 for the following years. The sensitivities of fluorescein angiography, SD OCT, and visual acuity loss ≥ 5 letters were 62.6 %, 51.4 %, and 40 %, respectively. The fluorescein angiography showed a significantly higher sensitivity in treatment decision than OCT (p = 0.007). Conclusion: Our study has shown that ranibizumab injections provide a significant long-term visual benefit in myopic CNV with a small number of injections. Fluorescein angiography has a preponderant role in the treatment decision of active myopic CNV.
Resumo:
Stellar-mass black holes have all been discovered through X-ray emission, which arises from the accretion of gas from their binary companions (this gas is either stripped from low-mass stars or supplied as winds from massive ones). Binary evolution models also predict the existence of black holes accreting from the equatorial envelope of rapidly spinning Be-type stars (stars of the Be type are hot blue irregular variables showing characteristic spectral emission lines of hydrogen). Of the ~80 Be X-ray binaries known in the Galaxy, however, only pulsating neutron stars have been found as companions. A black hole was formally allowed as a solution for the companion to the Be star MWC 656 (also known as HD 215227), although that was based on a single radial velocity curve of the Be star, a mistaken spectral classification and rough estimates of the inclination angle. Here we report observations of an accretion disk line mirroring the orbit of the Be star. This, together with an improved radial velocity curve of the Be star through fitting sharp Fe II profiles from the equatorial disk, and a refined Be classification (to that of a B1.5-B2 III star), reveals a black hole of 3.8 to 6.9 solar masses orbiting MWC 656, the candidate counterpart of the gamma-ray source AGL J2241+4454. The black hole is X-ray quiescent and fed by a radiatively inefficient accretion flow giving a luminosity less than 1.6 x 10-7 times the Eddington luminosity. This implies that Be binaries with black-hole companions are difficult to detect by conventional X-ray surveys.
Resumo:
Gelled aspect in papaya fruit is typically confused with premature ripening. This research reports the characterization of this physiological disorder in the pulp of papaya fruit by measuring electrolyte leakage, Pi content, lipid peroxidation, pulp firmness, mineral contents (Ca, Mg and K - in pulp and seed tissues), and histological analysis of pulp tissue. The results showed that the gelled aspect of the papaya fruit pulp is not associated with tissue premature ripening. Data indicate a reduction of the vacuole water intake as the principal cause of the loss of cellular turgor; while the waterlogged aspect of the tissue may be due to water accumulation in the apoplast.