799 resultados para NESTING SUCCESS
Resumo:
Simulating surface wind over complex terrain is a challenge in regional climate modelling. Therefore, this study aims at identifying a set-up of the Weather Research and Forecasting Model (WRF) model that minimises system- atic errors of surface winds in hindcast simulations. Major factors of the model configuration are tested to find a suitable set-up: the horizontal resolution, the planetary boundary layer (PBL) parameterisation scheme and the way the WRF is nested to the driving data set. Hence, a number of sensitivity simulations at a spatial resolution of 2 km are carried out and compared to observations. Given the importance of wind storms, the analysis is based on case studies of 24 historical wind storms that caused great economic damage in Switzerland. Each of these events is downscaled using eight different model set-ups, but sharing the same driving data set. The results show that the lack of representation of the unresolved topography leads to a general overestimation of wind speed in WRF. However, this bias can be substantially reduced by using a PBL scheme that explicitly considers the effects of non-resolved topography, which also improves the spatial structure of wind speed over Switzerland. The wind direction, although generally well reproduced, is not very sensitive to the PBL scheme. Further sensitivity tests include four types of nesting methods: nesting only at the boundaries of the outermost domain, analysis nudging, spectral nudging, and the so-called re-forecast method, where the simulation is frequently restarted. These simulations show that restricting the freedom of the model to develop large-scale disturbances slightly increases the temporal agreement with the observations, at the same time that it further reduces the overestimation of wind speed, especially for maximum wind peaks. The model performance is also evaluated in the outermost domains, where the resolution is coarser. The results demonstrate the important role of horizontal resolution, where the step from 6 to 2 km significantly improves model performance. In summary, the combination of a grid size of 2 km, the non-local PBL scheme modified to explicitly account for non-resolved orography, as well as analysis or spectral nudging, is a superior combination when dynamical downscaling is aimed at reproducing real wind fields.
Resumo:
music by Peretz Sandler. Words by Isidor Lilien
Resumo:
BACKGROUND In the meantime, catheter ablation is widely used for the treatment of persistent atrial fibrillation (AF). There is a paucity of data about long-term outcomes. This study evaluates (1) 5-year single and multiple procedure success and (2) prognostic factors for arrhythmia recurrences after catheter ablation of persistent AF using the stepwise approach aiming at AF termination. METHODS AND RESULTS A total of 549 patients with persistent AF underwent de novo catheter ablation using the stepwise approach (2007-2009). A total of 493 patients were included (Holter ECGs ≥ every 6 months). Mean follow-up was 59 ± 16 months with 2.1 ± 1.1 procedures per patient. Single and multiple procedure success rates were 20.1% and 55.9%, respectively (80% off antiarrhythmic drug). Antiarrhythmic drug-free multiple procedure success was 46%. Long-term recurrences (n=171) were paroxysmal AF in 48 patients (28%) and persistent AF/atrial tachycardia in 123 patients (72%). Multivariable recurrent event analysis revealed the following factors favoring arrhythmia recurrence: failure to terminate AF during index procedure (hazard ratio [HR], 1.279; 95% confidence interval [CI], 1.093-1.497; P = 0.002), number of procedures (HR, 1.154; 95% CI, 1.051-1.267; P = 0.003), female sex (HR, 1.263; 95% CI, 1.027-1.553; P = 0.027), and the presence of structural heart disease (HR, 1.236; 95% CI, 1.003-1.524; P = 0.047). AF termination was correlated with a higher rate of consecutive procedures because of atrial tachycardia recurrences (P = 0.003; HR, 1.71; 95% CI, 1.20-2.43). CONCLUSIONS Catheter ablation of persistent AF using the stepwise approach provides limited long-term freedom of arrhythmias often requiring multiple procedures. AF termination, the number of procedures, sex, and the presence of structural heart disease correlate with outcome success. AF termination is associated with consecutive atrial tachycardia procedures.