996 resultados para Microwave measurements
Resumo:
This work describes a simulation tool being developed at UPC to predict the microwave nonlinear behavior of planar superconducting structures with very few restrictions on the geometry of the planar layout. The software is intended to be applicable to most structures used in planar HTS circuits, including line, patch, and quasi-lumped microstrip resonators. The tool combines Method of Moments (MoM) algorithms for general electromagnetic simulation with Harmonic Balance algorithms to take into account the nonlinearities in the HTS material. The Method of Moments code is based on discretization of the Electric Field Integral Equation in Rao, Wilton and Glisson Basis Functions. The multilayer dyadic Green's function is used with Sommerfeld integral formulation. The Harmonic Balance algorithm has been adapted to this application where the nonlinearity is distributed and where compatibility with the MoM algorithm is required. Tests of the algorithm in TM010 disk resonators agree with closed-form equations for both the fundamental and third-order intermodulation currents. Simulations of hairpin resonators show good qualitative agreement with previously published results, but it is found that a finer meshing would be necessary to get correct quantitative results. Possible improvements are suggested.
Resumo:
OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.
Resumo:
OBJECTIVE: Most studies assess the prevalence of hypertension in pediatric populations based on blood pressure (BP) readings taken on a single visit. We determined the prevalence of hypertension measured on up to three visits in a Swiss pediatric population and examined the association between hypertension and overweight and selected other factors. METHODS: Anthropometric data and BP were measured in all children of the sixth school grade of the Vaud canton (Switzerland) in 2005-2006. 'Elevated BP' was defined according to sex-specific, age-specific and height-specific US reference data. BP was measured on up to two additional visits in children with elevated BP. 'Hypertension' was defined as 'elevated BP' on all three visits. RESULTS: Out of 6873 children, 5207 (76%) participated [2621 boys, 2586 girls; mean (SD) age, 12.3 (0.5) years]. The prevalence of elevated BP was 11.4, 3.8 and 2.2% on first, second and thirds visits, respectively; hence 2.2% had hypertension. Among hypertensive children, 81% had isolated systolic hypertension. Hypertension was associated with excess body weight, elevated heart rate and parents' history of hypertension. Of the children, 16.1% of boys and 12.4% of girls were overweight or obese (CDC criteria, body mass index >or= 85th percentile). Thirty-seven percent of cases of hypertension could be attributed to overweight or obesity. CONCLUSIONS: The proportion of children with elevated BP based on one visit was five times higher than based on three measurements taken at few-week intervals. Our data re-emphasize the need for prevention and control of overweight in children to curb the global hypertension burden.
Resumo:
This paper proposes the use of an autonomous assistant mobile robot in order to monitor the environmental conditions of a large indoor area and develop an ambient intelligence application. The mobile robot uses single high performance embedded sensors in order to collect and geo-reference environmental information such as ambient temperature, air velocity and orientation and gas concentration. The data collected with the assistant mobile robot is analyzed in order to detect unusual measurements or discrepancies and develop focused corrective ambient actions. This paper shows an example of the measurements performed in a research facility which have enabled the detection and location of an uncomfortable temperature profile inside an office of the research facility. The ambient intelligent application has been developed by performing some localized ambient measurements that have been analyzed in order to propose some ambient actuations to correct the uncomfortable temperature profile.
Resumo:
Tässä työssä on esitetty väsyttävän kuormituksen mittaamiseen ja mittausdatan jälkikäsittelyyn sekä väsymismitoitukseen liittyviä menetelmiä. Menetelmien sovelluskohteena oli metsäkoneen kuormain, joka on väsyttävästi kuormitettu hitsattu rakenne. Teoriaosassa on kuvattu väsymisilmiötä ja väsymismitoitusmenetelmiä sekä kuormitusten tunnistamiseen ja mittausten jälkikäsittelyyn liittyviä menetelmiä. Yleisimmin käytettyjen väsymismitoitusmenetelmien rinnalle on esitetty luotettavuuteen perustuvaa väsymismitoitusmenetelmää. Kuormainten suunnittelussa on keveys- j a kestoikävaatimusten takia erityisen suuri merkitys väsymisen huomioimisella. Rakenteille on ominaista tietyt toiminnan kannalta välttämättömät hitsatut yksityiskohdat, jotka usein määräävät koko rakenteen kestoiän. Koska nämä ongelmakohdat pystytään useimmiten tunnistamaan jo suunnitteluvaiheessa, voidaan yksityiskohtien muotoilulla usein parantaa huomattavasti koko rakenteen kestoikää. Näiden yksityiskohtien optimointi on osittain mahdollista toteuttaa ilman kuormituskertymätietoa, mutta useimmiten kuormitusten tunnistaminen on edellytys parhaan ratkaisun löytymiselle. Tällöin toistaiseksi paras keino todellisen väsyttävän kuormituksen tunnistamiseksi on pitkäaikaiset kenttämittaukset. Kenttämittauksilla selvitetään rakenteeseen kohdistuvat kuormitukset venymäliuskojen avulla. Kuormitusten tunnistamisella on erityisen suuri merkitys kun halutaan määrittää rakenteen kestoikä. Väsyminen ja väsyttävä kuormitus ovat kuitenkin tilastollisia muuttujia j a yksittäiselle rakenteelle ei ole mahdollista määrittää tarkkaa k estoikää. Tilastollisia menetelmiä käyttäen on kuitenkin mahdollista määrittää rakenteen vaurioitumisriski. Laskettaessa vaurioitumisriskiä suurelle määrälle yksittäisiä rakenteita voidaan muodostaa tarkkojakin ennusteita mahdollisten vaurioiden lukumäärästä. Tällöin kuormituskertymätiedosta voi olla tavanomaisen suunnittelun lisäksi laajempaa hyötyä esimerkiksi takuukäsittelyssä. Tässä työssä on sovellettu esitettyjä teorioita käytännössä metsäkoneen harvesterin puomiston väsymistarkasteluun. Kyseisen rakenteen kuormituksia mitattiin kahden viikon aikana yhteensä 35 tuntia, jonka perusteella laskettiin väsyttävän kuormituksen tilastollinen jakauma esimerkkitapaukselle. Mittauksen perusteella ei voitu tehdä kuitenkaan johtopäätöksiä tuotteen koko elinkaaren kuormituksista eikä muiden samanlaisten tuotteiden kuormituksista, koska mitattu otos oli suhteellisen lyhyt ja rajoittui vain yhteen käyttäjään ja muutamaan käyttökohteeseen. Menetelmien testaamiseksi kyseinen otos oli kuitenkin riittävä. Kuormituskertymätietoa käytettiin hyväksi myös laatumääritysten muodostamisessaesimerkkitapaukselle. Murtumismekaniikkaan perustuvalla menetelmällä arvioitiinharvesteripilarin valun mahdollisten valuvirheiden suurin sallittu koko. Luotettavuuteen pohjautuvan mitoitusmenettelyn tarve näyttää olevanlisääntymässä, joten pitkäaikaisten kenttämittausten tehokas hyödyntäminen tulee olemaan keskeinen osa väsymismitoitusta lähitulevaisuudessa. Menetelmiä olisi mahdollista tehostaa yhdistämällä kuormituskertymään erilaisia kuormitusten suhteen riippuvia tunnettuja suureita kuten käsiteltävän puun halkaisija. Todellisettuotekohtaiset tilastolliset jakaumat kuormituksista voitaisiin muodostaa mahdollisesti tehokkaammin, jos esimerkiksi kuormitusten riippuvuus metsätyypistä pystyttäisiin ensin määrittämään.
Resumo:
Nicotine in a smoky indoor air environment can be determined using graphitized carbon black as a solid sorbent in quartz tubes. The temperature stability, high purity, and heat absorption characteristics of the sorbent, as well as the permeability of the quartz tubes to microwaves, enable the thermal desorption by means of microwaves after active sampling. Permeation and dynamic dilution procedures for the generation of nicotine in the vapor phase at low and high concentrations are used to evaluate the performances of the sampler. Tube preparation is described and the microwave desorption temperature is measured. Breakthrough volume is determined to allow sampling at 0.1-1 L/min for definite periods of time. The procedure is tested for the determination of gas and paticulate phase nicotine in sidestream smoke produced in an experimental chamber.
Resumo:
This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.
Resumo:
PAH (N-(4-aminobenzoyl)glycin) clearance measurements have been used for 50 years in clinical research for the determination of renal plasma flow. The quantitation of PAH in plasma or urine is generally performed by colorimetric method after diazotation reaction but the measurements must be corrected for the unspecific residual response observed in blank plasma. We have developed a HPLC method to specifically determine PAH and its metabolite NAc-PAH using a gradient elution ion-pair reversed-phase chromatography with UV detection at 273 and 265 nm, respectively. The separations were performed at room temperature on a ChromCart (125 mmx4 mm I.D.) Nucleosil 100-5 microm C18AB cartridge column, using a gradient elution of MeOH-buffer pH 3.9 1:99-->15:85 over 15 min. The pH 3.9 buffered aqueous solution consisted in a mixture of 375 ml sodium citrate-citric acid solution (21.01 g citric acid and 8.0 g NaOH per liter), added up with 2.7 ml H3PO4 85%, 1.0 g of sodium heptanesulfonate and completed ad 1000 ml with ultrapure water. The N-acetyltransferase activity does not seem to notably affect PAH clearances, although NAc-PAH represents 10.2+/-2.7% of PAH excreted unchanged in 12 healthy subjects. The performance of the HPLC and the colorimetric method have been compared using urine and plasma samples collected from healthy volunteers. Good correlations (r=0.94 and 0.97, for plasma and urine, respectively) are found between the results obtained with both techniques. However, the colorimetric method gives higher concentrations of PAH in urine and lower concentrations in plasma than those determined by HPLC. Hence, both renal (ClR) and systemic (Cls) clearances are systematically higher (35.1 and 17.8%, respectively) with the colorimetric method. The fraction of PAH excreted by the kidney ClR/ClS calculated from HPLC data (n=143) is, as expected, always <1 (mean=0.73+/-0.11), whereas the colorimetric method gives a mean extraction ratio of 0.87+/-0.13 implying some unphysiological values (>1). In conclusion, HPLC not only enables the simultaneous quantitation of PAH and NAc-PAH, but may also provide more accurate and precise PAH clearance measurements.
Resumo:
This research has been focused at the development of a tuned systematic design methodology, which gives the best performance in a computer aided environment and utilises a cross-technological approach, specially tested with and for laser processed microwave mechanics. A tuned design process scheme is also presented. Because of the currently large production volumes of microwave and radio frequency mechanics even slight improvements of design methodologies or manufacturing technologies would give reasonable possibilities for cost reduction. The typical number of required iteration cycles could be reduced to one fifth of normal. The research area dealing with the methodologies is divided firstly into a function-oriented, a performance-oriented or a manufacturability-oriented product design. Alternatively various approaches can be developed for a customer-oriented, a quality-oriented, a cost-oriented or an organisation-oriented design. However, the real need for improvements is between these two extremes. This means that the effective methodology for the designers should not be too limited (like in the performance-oriented design) or too general (like in the organisation-oriented design), but it should, include the context of the design environment. This is the area where the current research is focused. To test the developed tuned design methodology for laser processing (TDMLP) and the tuned optimising algorithm for laser processing (TOLP), seven different industrial product applications for microwave mechanics have been designed, CAD-modelled and manufactured by using laser in small production series. To verify that the performance of these products meets the required level and to ensure the objectiveness ofthe results extensive laboratory tests were used for all designed prototypes. As an example a Ku-band horn antenna can be laser processed from steel in 2 minutes at the same time obtaining a comparable electrical performance of classical aluminium units or the residual resistance of a laser joint in steel could be limited to 72 milliohmia.
Resumo:
Regression equations predicting dissectable muscle weight in rabbits from external measurements were presented. Bone weight and weight of muscle groups were also carcass predicted. Predictive capacity of external measurements, retail cuts and muscle groups on total muscle, percent muscle, total bone and muscle to bone ratio were studied separately. Measurements on dissected retail cuts should be included in ordcr to obtain good equations for prediction of percent muscle in the carcass. Equations for predicting the muscle to bone ratio using external mcasurcments and data from the dissection of one hind leg were suggested. The equations had generally high coefficients of determination. The coefficient of determination for prediction of dissectable muscle was 0.91, and for percent muscle in the carcass 0.79.
Resumo:
Tässä diplomityössä tavoitteena on selvittää käytännöt ja menetelmät, joilla UPM-Kymmenen sellu-, paperi- ja vaneritehtaat ympäri maailman mittaavat ja laskevat ilmapäästönsä. Tämä tehdään kyselylomakkeella, joka lähetetään tehtaiden ympäristöpäälliköille. Kaikki tärkeimmät seikat ilmapäästöihin liittyen, kuten vaaditut jatkuvatoimiset mittaukset, jaksottaiset mittaukset, raportointikäytäntö, kalibrointi jne. kysytään lomakkeessa. Kyselylomakkeessa painotetaan mittauskäytäntöä sellutehtaissa sekä energiantuotannossa. Saatujen tulosten perusteella annetaan ehdotuksia sekä ohjeita tulevaisuutta varten, jotta mittaustulosten kokoaminen helpottuisi ja vertailukelpoisuus paranisi. Työn kirjallisuusosuudessa selvitetään yleisimmät päästölähteet sekä päästökomponentit paperi –ja selluteollisuudessa. Näiden ei toivottujen yhdisteiden syntymekanismit sekä menetelmät niiden poistamiseksi savukaasuista on myös lyhyesti kuvailtu. Myös erilaiset analysointi- ja näytteenottomenetelmät on kerrottu. Erot tehtaiden ympäristöluvissa käydään läpi, jakaen tehtaat kolmeen maantieteelliseen ryhmään. Lupakäytäntöjen osalta Suomen osuutta on painotettu, sillä UPM-Kymmene on varsin Suomikeskeinen yhtiö tehtaiden lukumääriin ja sijainteihin katsottuna. Viranomaismääräykset sekä päästörajat muutamista tehtaista on esitetty havainnollistaakseen alueellisia eroja.
Resumo:
Water soluble perchlorinated trityl (PTM) radicals were found to be effective 95 GHz DNP (dynamic nuclear polarization) polarizers in ex situ (dissolution) 13C DNP (Gabellieri et al., Angew Chem., Int. Ed. 2010, 49, 3360). The degree of the nuclear polarization obtained was reported to be dependent on the position of the chlorine substituents on the trityl skeleton. In addition, on the basis of the DNP frequency sweeps it was suggested that the 13C NMR signal enhancement is mediated by the Cl nuclei. To understand the DNP mechanism of the PTM radicals we have explored the 95 GHz EPR characteristics of these radicals that are relevant to their performance as DNP polarizers. The EPR spectra of the radicals revealed axially symmetric g-tensors. A comparison of the spectra with the 13C DNP frequency sweeps showed that although the solid effect mechanism is operational the DNP frequency sweeps reveal some extra width suggesting that contributions from EPR forbidden transitions involving 35,37Cl nuclear flips are likely. This was substantiated experimentally by ELDOR (electron-electron double resonance) detected NMR measurements, which map the EPR forbidden transitions, and ELDOR experiments that follow the depolarization of the electron spin upon irradiation of the forbidden EPR transitions. DFT (density functional theory) calculations helped to assign the observed transitions and provided the relevant spin Hamiltonian parameters. These results show that the 35,37Cl hyperfine and nuclear quadrupolar interactions cause a considerable nuclear state mixing at 95 GHz thus facilitating the polarization of the Cl nuclei upon microwave irradiation. Overlap of Cl nuclear frequencies and the 13C Larmor frequency further facilitates the polarization of the 13C nuclei by spin diffusion. Calculation of the 13C DNP frequency sweep based on the Cl nuclear polarization showed that it does lead to an increase in the width of the spectra, improving the agreement with the experimental sweeps, thus supporting the existence of a new heteronuclear assisted DNP mechanism.